www.Amprobe.com
ACD-14 PLUS DETAILED SPECIFICATIONS
Specifications Range
Display 3-3/4 digits 4000 counts, dual LCD displays
UpdateRate 3 per second nominal
Polarity Automatic
LowBatteryIndication Below approx. 2.4V
OperatingTemperature 0°C to 40°C (32°F to 104°F)
RelativeHumidity Maximum relative humidity 80% for temperatures up to 31°C (88°F)
decreasing linearly to 50% relative humidity at 40°C (104°F)
Altitude Indoor operation below 2000m (6,562 ft)
StorageTemperature -20°C to 60°C (-4°F to 140°F), < 80% R.H. (with battery removed)
TemperatureCoefcient Nominal 0.15 x (specified accuracy)/°F @ 0°C - 18°C or 28°C - 40°C
(32°F -64°F or 82°F - 104°F), or otherwise specified
Sensing Average sensing for ACD-14 PLUS
PowerSupply Two 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2032).
BatteryLife 95 hours approx. (in DCV mode)
PowerConsumption 2.5 mA typical for ACD-14 PLUS
LowBatteryIndication Below approx. 2.4V (battery symbol appears in upper right)
AutoPowerOff After being idle for 30 minutes
APOConsumption ACD-14 PLUS: 0.8μA typical except 25μA typical for temperature function
Safety CE EN61010-1, EN61010-2-032 - Pollution Degree 2
TransientProtection 6.5kV (1.2/50μs surge) for all models
E.M.C. Meets EN61326
OverloadProtectionsRMS ACA Clamp-on jaws: AC 600A RMS continuous “+” & “COM” terminals (all functions): 600VDC/VAC
Dimension L190mm X W 63mm X H 32mm (L 7.48” X W 2.48” X H 1.25”)
Weight 204 g (0.450 lb approx.)
Jawopening&
Conductordiameter 25 (1.0”) max
IncludedAccessories Test Leads, Carrying Case, Bead Type, Thermocouple with banana plug, Users Manual
OptionalAccessories
ELS2A Line splitter
ACF-3000AK 3000A AC Flexible Clamp-On Attachment
TA-1A Temperature Adapter
TL36A Heavy Duty Test Leads with Threaded Alligator Clips
ELECTRICAL SPECIFICATIONS 23°C ± 5°C (73°F ± 9°F) & < 75% R.H.
Specifications Range
DCVoltage
400.0 mV ± (0.3% rdg + 4 digits)
4.000V, 40.00V, 400.0V ± (0.5% rdg + 3 digits)
600V ± (1.0% rdg + 4 digits)
NMRR: >50dB @ 50/60Hz
CMRR: >120dB @ DC, 50/60Hz, Rs=1kΩ
Input Impedance: 10MΩ, 30pF nominal (1000MΩ for 400.0mV range)
ACVoltage[50Hz--500Hz]
Averagesensing
4.000V, 40.00V, 400.0V ± (1.5% rdg + 5 digits)
600V ± (2.0% rdg + 5 digits)
CMRR: >60dB @ DC to 60Hz, Rs=1kΩ
Input Impedance: 10MΩ, 30pF nominal
ACCurrent(Clamp-on)
[50Hz/60Hz]
40.00A ± (1.5% rdg + 8 digits)
400.0A ± (1.5% rdg + 8 digits)
600A ± (1.5% rdg + 8 digits)*
*Accuracy specified to 600A continuous.
For detailed specifications and ordering info go to www.Amprobe.com 3128489B
©2014 Amprobe. All rights reserved.