MAT10xxx Series Attenuator DIE DC - 20 GHz Rev. V4 Features Medium Power Handling 2 W CW Flat Response from DC to 20 GHz Return Loss: >18 dB DC to 12 GHz >16 dB 13 to 20 GHz Space Saving Footprint: 0.030" x 0.030" (0.762 x 0.762 mm) Very Good Stability Over Temperature (TRC <100 PPM) Ground Wrap to Top (No ground bonding required) RoHS* Compliant Front to back metallization in 4 places Description These fixed attenuator chips are fabricated using our state of the art thin film metallization and advanced photolithography technology. All devices are available in chip form with a metalized ground connection on the back. This ground is wrapped around on the four corners of the chip so additional ground bonding ribbon is not required. Bonding pad sizes and resistor outline may differ from value to value. The chips may be attached using conductive epoxy or solder preform. Gold contacts on the input and output pads make assembly, using standard bonding equipment, fast and reliable. Custom values and configuration available on request. Electrical Specifications: TA = +25C Part Number Attenuation (dB) Insertion Loss (dB) Return Loss (dB) MAT10010 1 +/-0.30 >18 MAT10020 2 +/-0.30 >18 MAT10030 3 +/-0.30 >18 MAT10040 4 +/-0.30 >18 MAT10050 5 +/-0.30 >18 MAT10060 6 +/-0.35 >18 MAT10070 7 +/-0.35 >18 MAT10080 8 +/-0.35 >18 CONTINUED 1 * Restrictions on Hazardous Substances, European Union Directive 2011/65/EU. MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support DC-0011352 MAT10xxx Series Attenuator DIE DC - 20 GHz Rev. V4 Electrical Specifications: TA = +25C Part Number Attenuation (dB) Insertion Loss (dB) Return Loss (dB) MAT10090 9 +/-0.35 >18 MAT10100 10 +/-0.35 >18 MAT10110 11 +/-0.40 >18 MAT10120 12 +/-0.40 >18 MAT10130 13 +/-0.40 >18 MAT10140 14 +/-0.40 >18 MAT10150 15 +/-0.40 >18 MAT10160 16 +/-0.50 >18 MAT10170 17 +/-0.50 >18 MAT10180 18 +/-0.50 >18 MAT10190 19 +/-0.50 >18 MAT10200 20 +/-0.50 >18 MAT10210 21 +/-0.60 >18 MAT10220 22 +/-0.60 >18 MAT10230 23 +/-0.60 >18 MAT10240 24 +/-0.60 >18 MAT10250 25 +/-0.60 >18 MAT10260 26 +/-1.00 >18 MAT10270 27 +/-1.00 >18 MAT10280 28 +/-1.00 >18 MAT10290 29 +/-1.00 >18 MAT10300 30 +/-1.00 >18 Absolute Maximum Ratings1,2 2 Parameter Absolute Maximum RF Incident Power 33 dBm Operating Temperature -55C to +150C Storage Temperature -65C to +150C Assembly Temperature +280C for 10 seconds 1. Exceeding any one or combination of these limits may cause permanent damage to this device. 2. MACOM does not recommend sustained operation near these survivability limits. MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support DC-0011352 MAT10xxx Series Attenuator DIE DC - 20 GHz Rev. V4 MACOM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with MACOM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale. 3 MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support DC-0011352