SPECIFICATION
TS-700-112TS-700-124TS-700-148TS-700-212TS-700-224TS-700-248
38A
21 ~ 30VDC
88%
19A
42 ~ 60VDC
89%
38A
21 ~ 30VDC
90%
19A
42 ~ 60VDC
91%
MODEL
MAXIMUM OUTPUT POWER (Typ.)
WAVEFORM Note.6
OUTPUT FREQUENCY
AC REGULATION (Typ.)
VOLTAGE RANGE (Typ.)Note.3,5
EFFICIENCY (Typ.) Note.1
DC CURRENT (Typ.)
INPUT
INPUT
BATTERY
OUTPUT
ENVIRONMENT
FUSE
SAFETY &
EMC
BAT. LOW ALARM
BAT. LOW SHUTDOWN
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARITY
GFCI PROCTECTION
PROTECTION
PROTECTION
True sine wave (THD<3%)
75A
10.5 ~ 15VDC
89%
40A*3 30A*2 20A*2
20A*230A*2
±3.0%
10.5 ~ 15VDC
86%
75A
40A*3
80 5℃±
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power diode
Protection type : Shut down o/p voltage, re-power on to recover
75 5℃±
By internal fuse open
Optional (Only type F) None
Compliance to FCC class A
None
WORKING TEMP. Note.4
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
SAFETY STANDARDS
0 ~ +40 @ 100% load ; +60 @ 50% load℃℃
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RHo
Design refer to
U 458L
Compliance to EN61000-4-2,3,8
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
True sine wave output (THD<3%)
High surge power up to 1400W
High efficiency up to 91%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Built-in fan ON-OFF control function
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
RATED POWER (Typ.) 700W
OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
AC O/P-FG , Bat I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Features :
OTHERS
PACKING 3.8Kg; 2pcs/8.6Kg/1.27CUFT
DIMENSION 295*184*70mm (L*W*H)
NOTE 1.Efficiency is tested by 530W, linear load at 13V, 26V, 52V input voltage.
2.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
3.Input derating capacity referenced by curve 2.
4.Output derating capacity referenced by curve 1.
5.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V→± →± →±
6.THD is tested by 700W, linear load at 13,26,52V input voltage.
800W for 180 sec. / 1050W for 10 sec. / surge power 1400W for 30 cycles
11.3 4%±22.5 4%±45 4%±45 4%±22.5 4%±
10.5 4%±21 4%±42 4%±42 4%±
None
21 4%±
11.3 4%±
10.5 4%±
TS-700 series
File Name:TS-700-SPEC 2015-05-27
50 0.1Hz 50/60Hz selectable by setting button S.W±
60 0.1Hz 50/60Hz selectable by setting button S.W±
FRONT PANEL INDICATOR
SAVING MODE (Typ.) Default disabled. Load 5W will be changed to standby mode
Battery voltage level, output load level, saving mode, fault and operation status
24V 48V 24V 48V
BAT. VOLTAGE 12V12V
NO LOAD DISSIPATION 6W @ standby saving mode
OFF MODE CURRENT DRAW 1mA
BATTERY TYPES Open & sealed Lead Acid
700W True Sine Wave DC-AC Power Inverter
AC VOLTAGE 200 / 220 / 230 / 240VAC selectable by setting button S.W
100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 110VAC Factory setting set at 230VAC
LVD None EN60950-1
E
13
MTBF 74.4K hrs min. MIL-HDBK-217F (25 )
EMC IMMUNITY
EMC EMISSION
Mechanical Specification
Remote port
Off
On
Load
Battery
Status
AC Output
Setting
Remote port
Load
Battery
Status
AC Output
Setting
Off
On
Type-A
Type-B
CURVE 1
CURVE 2
AMBIENT TEMPERATURE ( )
010203040506070
20
40
60
80
100
BATTERY INPUT VOLTAGE (V)
10.5VDC
21VDC
42VDC
11.5VDC
23VDC
46VDC
15VDC
30VDC
60VDC
20
40
60
80
100
(HORIZONTAL)
LOAD (%)
LOAD (%)
File Name:TS-700-SPEC 2015-05-27
TS-700 series
True sine wave inverter 12:12VDC
24:24VDCBat. Voltage:
48:48VDC
1:110VAC
2:230VAC
Output:
O/P Wattage:700W
TS 700 112 A
700W True Sine Wave DC-AC Power Inverter
28.55
27.2
50.05
19.22
10.7
70
BATTERY
Reverse Polarity Will
Damage The Unit.
NEG POS
Chassis
Ground
WARNING:
Cat.No.(1GG1HS-212)
Wire Range(10-4AWG Str
Cu Soldered Wires)
Torque (17.7-26.5 in lb)
Inverter
Inverter
Inverter
Inverter
10
7
171
184
direction
12
48
180 57.5
295
Air flow
A :TYPE
B :TYPE
C :TYPE
D :TYPE
E :TYPE
F :TYPE
A
B
C
D
E
F
OUTLET
OUTLET
OUTLET
OUTLET
OUTLET
OUTLET
TYPE-A
Receptacle type
Country
Certificate
TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F
USA EUROPE AUSTRALIA U.K JAPAN GFCI
AC Output Receptacles (optional)
E
13
EE
13 13
Derating Curve
Unit:mm
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Mean Well:
TS-700-112F TS-700-124F TS-700-148F TS-700-112A TS-700-124A TS-700-148A