Hawk 3 Digital Panel Meter / Controller All parameters set from easy to understand front panel access 2QHWZRRUIRXUDPSUHOD\VRSWLRQDO )LYHXVHUVHOHFWDEOHEULJKWQHVVOHYHOV ',1VKDOORZGHSWKFDVH 56GLJLWDOFRPPXQLFDWLRQVRSWLRQDO+ RU'&9([FLWDWLRQRXWSXWRSWLRQDOPD[LPXPPA#9DQGPA#9 PARU'&9DQDORJUHWUDQVPLVVLRQRSWLRQDO 1(0A;UDWHGIURQWSDQHO 1 Rev. 01-19 Hawk 3 Digital Panel Meter / Controller Type Height Brightness Decimal Point Overrange Indication DISPLAY 7- segment, red LED, 4 or 5 digits 0.56" (14.2mm) 5 settings, user programmable 4 or 5 position, user programmable ENVIRONMENTAL Operating Temperature 0 to 50C Storage Temperature -10 to +60C Relative Humidity < 80% for the temp. up to 31C and decreasing linearly to 50% relative humidity at 50C Ambient Temp 25C Temperature Drift 100 ppm /C Warmup time 10 minutes Value Exceeded (Example: H335) Underrange Indication Alarm Indicators Linearization Value Exceeded (Example: H335) 4 LED indicators for up to four independent setpoints H335 2 points H345 16 points NOISE REJECTION NMRR 60 dB @ 50-60 Hz CMRR 70 db @ 50-60 Hz For indoor use to an altitude up to 200m POWER REQUIREMENTS AC 85 to 250 VAC or 120VAC @ 10VA DC 9 to 36 DCV @ 10VA Isolation 250V RMS MAX Note: Each supply is shown at the maximum and minimum values except the 120 VAC unit, which is allowed 10% Technique Sample Rate Display Rate RS-485 Specications (only available on H345) 2 wire / Half duplex, Baud rate: 9600 baud, 1ms delay per character, 32 Nodes Maximum on Bus. Optically and magnetically isolated for ground loop elimination ACCURACY @ 25C as % of rdg 4-1/2 digit 3-1/2 digit DC Current High (5A, 2A) 0.2% of reading 1 count 0.3% of reading 1 count All others 0.05% of reading 1 count 0.1% of reading 1 count Bezel DC Volts High (600V) 0.1% of reading 1 count 0.2% of reading 1 count All others 0.05% of reading 1 count 0.1% of reading 1 count 0.1% of reading 2 counts 0.1% of reading 2 counts High (2A, 5A) 0.2% of reading 2 counts 0.3% of reading 2 counts All others 0.1% of reading 2 counts 0.2% of reading 2 counts High (600V) 0.1% of reading 1 count 0.2% of reading 1 count All others 0.05% of reading 1 count 0.1% of reading 1 count Depth Panel cutout Weight Cover Resistance All ranges A TO D CONVERSION Successive approximation with oversampling 10 conversions per second User Programmable from 1 - 420 updates / minute (240 default) * AC Current Accuracy * AC Volts Transient Overvoltage Analog Output MECHANICAL 3.92" x 2.0" x 0.52" (99.8mm x 51.9mm x 132mm) 3.24" (82.3mm) behind panel 3.62" x 1.77" (92mm x 45mm) 1/8 DIN 10 oz. (283.5 g) NEMA 4X Rated front panel ELECTRICAL Listed as % of reading at 25C. Add 100ppm/C to compensate for drift. Tested at 50Hz, include +/-1 count for every 100Hz above 50 Hz Installation Category III, Pollution Degree 2 Sampling Rate = 100 mSec. Reaction TLPHWR)XOO6FDOH 6HF * AC functions measured at 50 hz, include 1 count for each additional 100 Hz above 50 Hz 2 Rev. 01-19 Hawk 3 Digital Panel Meter / Controller Ordering Information - _ _ _ _ _ I I I I I I Basic Unit Power Supply Function/ Range Output Signal 5A Relay Excitation Select From Each One Below Basic Unit Function/Range Output Signal H335 3-1/2 digit, Red LED 41 200 ACA 0 H345 4-1/2 digit, Red LED 42 2 ACmA 1 4-20 DCmA 43 20 ACmA 2 0-10 DCV 6 RS-485 (4-1/2 only) 0 None Power Supply 44 200 ACmA 1 120 ACV (3-1/2 only) 45 2 ACA 2 85-250 ACV (4-1/2 only) 46 5 ACA 3 9-36 DCV 4 85-250 ACV (3-1/2 only) Function/Range None 5A Relays 51 200 ACmV TRMS 1 One 52 2 ACV TRMS 2 Two 53 20 ACV TRMS 4 Four 0 None 11 200 DCmv 54 200 ACV TRMS 12 2 DCV 55 600 ACV* TRMS 13 20 DCV 14 200 DCV 61 200 ACA TRMS 1 12 DCV 15 600 DCV * 62 2 ACmA TRMS 2 24 DCV 63 20 ACmA TRMS 21 200 DCA 64 200 ACmA TRMS 22 2 DCmA 65 2 ACA TRMS 23 20 DCmA 66 5 ACA TRMS 24 200 DCmA 25 2 DCA 71 4-20 DCmA Process 26 5 DCA 72 0-10 DCV Process 31 200 ACmV 81 200 Ohm 32 2 ACV 82 2K Ohm 33 20 ACV 83 20K Ohm 34 200 ACV 84 200K Ohm 35 600 ACV 3 Excitation Rev. 01-19 Hawk 3 Digital Panel Meter / Controller Installation and Panel Cutout - H335, H340, H345 Mounting Requirements The Hawk 3 Advanced Digital Controller 1/8 DIN meters require a panel cutout of 1.77" (45mm) high by 3.62" (92mm) wide. To install the Hawk 3 meter into a panel cutout, remove the clips from the side of the meter. Slide the meter through the panel cutout, then slide the mounting clips back on the meter. Press evenly to Engineering Label Placement To replace the engineering unit label, place the tip of a ballpoint pen into the small hole at the base of the engineering label in the bezel. Slide the label up until it pops out. Grasp and remove. Slide the new label half the distance in, then use the ballpoint pen to slide it down into place. Engineering Label 4 Rev. 01-19 Hawk 3 Digital Panel Meter / Controller Inputs DC Voltage Range AC Voltage (same for TRMS @ 60 Hz) Resolution Resolution Input 4-1/2 3-1/2 Impedance Overload Range Resolution Resolution Input 4-1/2 3-1/2 Impedance Overload 200 mV 10 V .1 mV 1M 5 DCV 200 mV 10 V .1 mV 200K 5 DCV 2V .1 mV 1 mV 1M 5 DCV 2V .1 mV 1 mV 200K 5 DCV 20 V 1 mV 10 mV 1M 300 DCV 20 V 1 mV 10 mV 1M 300 DCV 200 V 10 mV .1 V 1M 300 DCV 200 V 10 mV .1 V 1M 300 DCV 600 V .1 V 1V 1M 1K DCV 600 V .1 V 1V 1M 1K DCV DC Current Range AC Current (same for TRMS @ 60 Hz) Resolution Resolution Input 4-1/2 3-1/2 Impedance Overload Range Resolution 4-1/2 Resolution 3-1/2 Input Impedance .1 A 1K 4.5 mA DC 100 45 mA DC Overload 200 A 10 nA .1 A 1K 4.5 mA DC 200 A 10 nA 2 mA .1 A 1 A 100 45 mA DC 2 mA .1 A 1 A 20 mA 1 A 10 A 10 200 mA DC 20 mA 1 A 10 A 10 200 mA DC 200 mA 10 A .1 mA 1 600 mA DC 200 mA 10 A .1 mA 1 600 mA DC 2A .1 mA 1 mA .013 5.5 A DC 2A .1 mA 1 mA .013 5.5 A DC 5A 1 mA 10 mA .013 5.5 A DC 5A 1 mA 10 mA .013 5.5 A DC Resistance Range Resolution Resolution Input 4-1/2 3-1/2 Impedance Overload 200 10 m .1 1.2K 5 DCV . .1 1 12K 5 DCV 20K 1 10 . 5 DCV 200K 10 100 1.2M 5 DCV 5 Rev. 01-19