Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 82248 Coax - 75 Ohm Coax For more Information please call 1-800-Belden1 General Description: 18 AWG solid .040" bare copper conductor, plenum, foam FEP insulation, Duofoil(R) + tinned copper braid shield (65% coverage), Flamarrest(R) jacket. Physical Characteristics (Overall) Conductor AWG: # Coax AWG Stranding Conductor Material Dia. (in.) 1 18 Solid BC - Bare Copper .040 Total Number of Conductors: 1 Insulation Insulation Material: Insulation Material Dia. (in.) FFEP - Foam Fluorinated Ethylene Propylene .170 Outer Shield Outer Shield Material: Layer # Outer Shield Trade Name Type Outer Shield Material 1 Duofoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100 2 Braid TC - Tinned Copper 65 Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest(R) LS PVC - Low Smoke Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 0.222 in. Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C UL Temperature Rating: 75C Non-UL Temperature Rating: 75C Bulk Cable Weight: 28 lbs/1000 ft. Max. Recommended Pulling Tension: 45 lbs. Min. Bend Radius/Minor Axis: 2.250 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: No EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes RG Type: 6/U Page 1 of 3 04-18-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 82248 Coax - 75 Ohm Coax Flame Test UL Flame Test: NFPA 262 Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 9248 Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 75 Nom. Inductance: Inductance (H/ft) .09 Nom. Capacitance Conductor to Shield: Capacitance (pF/ft) 16.5 Nominal Velocity of Propagation: VP (%) 82 Nominal Delay: Delay (ns/ft) 1.24 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/1000 ft) 6.4 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/1000 ft) 5.1 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100 ft.) 1 .3 10 .7 50 1.6 100 2.2 200 3.0 400 4.6 700 6.6 900 7.7 1000 8.2 1500 10.7 1600 11.0 2000 12.9 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Operating Voltage - Non-UL: Voltage 300 V RMS Minimum Return Loss: Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Min. RL (dB) 5 450 23 Sweep Test Sweep Testing: 100% sweep tested. 5 MHz to 450 MHz. Put Ups and Colors: Item # Putup Ship Weight Color 82248 877U1000 1,000 FT 29.000 LB NATURAL 82248 8771000 1,000 FT 31.000 LB NATURAL Notes Item Desc #18 FFEP RG6/U FLMRST C #18 FFEP RG6/U FLMRST Notes: Page 2 of 3 04-18-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 82248 Coax - 75 Ohm Coax C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 08-27-2012 (c) 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Page 3 of 3 04-18-2017