To Be Discontinued Last time buy: September 30, 2018 49.2 17.5 24.1 AM1 (NZ) SWITCHES High Operating Precision Basic Switches with High Capacity and Long Life FEATURES TYPICAL APPLICATIONS * 10 A Current switching capacity * High precision and long life * Versatile variety of actuators * Screw terminal types can be used with M4 crimp terminals * Transfer machine * Packing machine * Textile equipment * Cutting machine * Foot operated switch, etc. (Unit: mm) RoHS compliant ORDERING INFORMATION AM1 Upper body cover shape & terminal 1: Flat, solder terminal 3: Flat, screw terminal 5: Grooved, solder terminal 7: Grooved, screw terminal Basic specifications 0: Standard type 1: Oil tight type 3: Reversed action type 4: One way type F Actuators 0: Pin plunger F: Cadmium free 1: Hinge lever (Flexible leaf lever) 3: Hinge roller lever (Flexible roller leaf lever) 4: Hinge short roller lever Upper body cover shape Flat Grooved 5: Overtravel plunger 6: Compact overtravel plunger 7: Panel mount plunger 811: Panel mount roller plunger 812: Panel mount cross roller plunger Note: Not every combination is available. Please refer to the following table, "PRODUCT TYPES". Standard part number indicates UL/C-UL (CSA standard) mark. -1- AECTB8E 201709-T To Be Discontinued Last time buy: September 30, 2018 AM1 (NZ) Basic Switches PRODUCT TYPES Standard type Terminal style Actuator Solder terminal AM1100F AM1105F AM1106F AM1107F AM110811F AM110812F AM1101F AM1103F AM1501F AM1504F AM1503F AM1544F AM1543F AM1531F AM1534F AM1533F Pin plunger Over travel plunger Compact over travel plunger Panel mount plunger Panel mount roller plunger Panel mount cross roller plunger Flexible leaf lever Flexible roller leaf lever Hinge lever Hinge short roller lever Hinge roller lever One way type hinge short roller lever One way type hinge roller lever Reversed action type hinge lever Reversed action type hinge short roller lever Reversed action type hinge roller lever Screw terminal AM1300F AM1305F AM1306F AM1307F AM130811F AM130812F AM1301F AM1303F AM1701F AM1704F AM1703F AM1744F AM1743F AM1731F AM1734F AM1733F Standard packing for inner carton: 20cps. Note: Standard part number indicates UL/C-UL (CSA standard) mark. Oil tight types Terminal style Actuator Solder terminal AM1511F AM1514F AM1513F Hinge lever Hinge short roller lever Hinge roller lever Screw terminal AM1711F AM1714F AM1713F Standard packing for inner carton: 20cps. Note: Standard part number indicates UL/C-UL (CSA standard) mark. SPECIFICATIONS Contact Rating Type Standard type Oil tight type Voltage Resistive load (cos = 1) Inductive load (cos = 0.4) 125 V AC 250 V AC 480 V AC 125 V DC 250 V DC 125 V AC 250 V AC 125 V DC 10 A 10 A 1A 0.5 A 0.25 A 10 A 10 A 0.5 A 6A 6A 0.5 A 0.05 A 0.03 A 6A 6A 0.05 A Motor or lamp load NC 3A 2A -- -- -- 3A 2A -- NO 1.5 A 1A -- -- -- 1.5 A 1.0 A -- Characteristics Item Pin plunger types Mechanical Expected life Other actuator types Electrical (OT: Max.) Insulation resistance Between non-continuous terminals Dielectric strength Between each terminal and other exposed metal parts Between each terminal and ground Contact resistance (initial) Vibration resistance (Pin plunger type) Pin plunger types Shock resistance Other actuator types Allowable operating speed (at no load) Max. operating cycle rate (at no load) Ambient temperature Unit weight Contact specifications Contact material Protection grade Specifications Min. 2 x107 (60 cpm) (OT: specified value) (Oil tight: Min. 1.5 x106) Min. 5 x106 (60 cpm) (OT: specified value) (Oil tight: Min. 1.5 x106) Min. 5 x105 (20 cpm) (at rated load) (Oil tight: Min. 1.5 x105) Min. 100 M (at 500 V DC) 1,000 Vrms for 1 min. 2,000 Vrms for 1 min. 2,000 Vrms for 1 min. Max. 50 m (by voltage drop, 1 A, 6 to 8 V DC) Single amplitude: 0.75 mm, 10 to 55 Hz (contact opening: max. 1 msec.) Min. 300 m/s2 (contact opening: max. 1 msec.) Min. 50 m/s2 (contact opening: max. 1 msec.) 0.1 to 1,000 mm/sec. (at pin plunger position) 240 cpm -25C to +80C (no freezing and condensing) Approx. 20 to 55 g Ag alloy IP40 -2- AECTB8E 201709-T To Be Discontinued Last time buy: September 30, 2018 AM1 (NZ) Basic Switches Operating Characteristics 1) Standard type Actuator Pin plunger Overtravel plunger Compact overtravel plunger Panel mount plunger Panel mount roller plunger Panel mount cross roller plunger Flexible leaf lever Flexible roller leaf lever Hinge lever Hinge short roller lever Hinge roller lever One way type hinge short roller lever One way type hinge roller lever Reversed action type hinge lever Reversed action type hinge short roller lever Reversed action type hinge roller lever Operating Force OF, max. Release Force RF, min. Pretravel PT, max. 3.63 N 3.63 N 3.63 N 3.63 N 3.63 N 3.63 N 1.47 N 1.47 N 0.69 N 1.57 N 0.98 N 2.23 N 1.67 N 1.67 N 5.30 N 2.35 N 0.12 N 0.12 N 0.12 N 0.12 N 0.12 N 0.12 N 0.14 N 0.14 N 0.14 N 0.42 N 0.2 N 0.42 N 0.42 N 0.27 N 1.67 N 0.56 N 0.4 mm 0.4 mm 0.4 mm 0.4 mm 0.4 mm 0.4 mm 4 mm 4 mm 10 mm 4.5 mm 7.5 mm 3.5 mm 4.5 mm 5.0 mm 2.5 mm 3.6 mm Movement Differential MD, max. 0.05 mm 0.05 mm 0.05 mm 0.05 mm 0.05 mm 0.05 mm 1.3 mm 1.3 mm 1.3 mm 0.7 mm 1.3 mm 0.4 mm 0.5 mm 0.9 mm 0.4 mm 0.7 mm Overtravel OT, min. Free Position FP, max. Operating Position OP 0.13 mm 1.5 mm 1.5 mm 5.6 mm 3.6 mm 3.6 mm 1.6 mm 1.6 mm 5.6 mm 2.4 mm 3.6 mm 1.5 mm 2.4 mm 5.6 mm 2.0 mm 4.0 mm -- -- -- -- -- -- -- -- -- -- -- 31.8 mm 43.3 mm -- -- -- 15.90.4 mm 28.20.5 mm 21.20.5 mm 21.80.8 mm 33.31.2 mm 33.31.2 mm 17.50.8 mm 28.60.8 mm 19.10.7 mm 30.20.4 mm 30.20.7 mm 30.20.4 mm 41.30.4 mm 19.10.8 mm 30.20.5 mm 30.20.8 mm 2) Oil tight types Actuator Hinge lever Hinge short roller lever Hinge roller lever Operating Force OF, max. Release Force RF, min. Pretravel PT, max. 0.69 N 1.67 N 0.98 N 0.14 N 0.42 N 0.20 N 10 mm 4.5 mm 7.5 mm Movement Differential MD, max. 1.5 mm 0.7 mm 1.3 mm Overtravel OT, min. Operating Position OP 5.6 mm 2.4 mm 3.6 mm 19.10.7 mm 30.20.4 mm 30.20.7 mm CONTACT FORM SPDT Reversed action type COM NO NC COM NC NO Contact return when actuator operates. Even in the free position (FP), excellent vibration resistance and shock resistance owing to immobilization by external force. TERMINAL STYLE Solder terminal Screw terminal 9.1 6.3 49.2 49.2 C NO NC 17.5 N.O. CIRCUT 17.5 N.C. CIRCUT 19.8 M4 screw P0.7 Terminal plate 20.2 Note: The position of reversed action type of NO and NC is reverse. -3- AECTB8E 201709-T To Be Discontinued Last time buy: September 30, 2018 AM1 (NZ) Basic Switches DIMENSIONS The CAD data of the products with a (Unit: mm) General tolerance: 0.4 CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ Standard types Pin plunger The photograph is a case of a screw terminal. The dimension is an intersection except a terminal section. Please refer to "TERMINAL STYLE" for the shape and size of terminal section. CAD Data 23.30.3 PT 2.40.15 dia. OP AM1100F (Solder terminal) AM1300F (Screw terminal) 4.2 +0.1 -0.05 4.50.1 25.40.1 49.2 Operating Force OF, max. 3.63 N Release Force RF, min. 1.12 N 14.6 15 Pretravel PT, max. 0.4 mm 5.4 9.1 Movement Differential MD, max. 0.05 mm Overtravel OT, min. 0.13 mm 4.2 +0.1 -0.05 dia. hole 17.5 11.9 Operating Position OP 15.90.4 mm Overtravel plunger CAD Data Operating Force OF, max. 3.63 N Release Force RF, min. 1.12 N 8.4 Pretravel PT, max. 0.4 mm 15 Movement Differential MD, max. 0.05 mm Overtravel OT, min. 1.5 mm 4 dia. 6.35 dia. 23.30.3 Plunger: Hardening steel PT OP AM1105F (Solder terminal) AM1305F (Screw terminal) Operating Position OP 28.20.5 mm Compact overtravel plunger CAD Data Plunger: Plastic PT 0.4 max. 23.30.3 7.1 dia. 4.2 21.20.5 4.2 +0.10 -0.05 14.3 14.5 OP 4. 2- +0. AM1106F (Solder terminal) AM1306F (Screw terminal) 0. 10 05 3.63 N Release Force RF, min. 1.12 N Pretravel PT, max. 0.4 mm Movement Differential MD, max. 0.05 mm Overtravel OT, min. 1.5 mm Operating Position OP Panel mount plunger 21.20.5 mm Plunger: Plastic 8.25 dia. 23.30.3 M12 x P1 13.1 Lock nut (2 thick) Nut (2 thick) 4.2 +0.10 -0.05 14.3 160.5 OP 21.80.8 PT 0.4 max. R8 The photograph is a case of a screw terminal. The dimension is an intersection except a terminal section. Please refer to "TERMINAL STYLE" for the shape and size of terminal section. CAD Data AM1107F (Solder terminal) AM1307F (Screw terminal) Operating Force OF, max. 4. 2 + -0 0.1 .0 5 Operating Force OF, max. 3.63 N Release Force RF, min. 1.12 N Pretravel PT, max. 0.4 mm Movement Differential MD, max. 0.05 mm Overtravel OT, min. 5.6 mm Operating Position OP di 21.80.8 mm a. -4- AECTB8E 201709-T To Be Discontinued Last time buy: September 30, 2018 AM1 (NZ) Basic Switches Panel mount roller plunger CAD Data 90 PT 0.4 max. M12 x P1 OP 33.31.2 15.5 Nut (2 thick) 4.2 +0.10 -0.05 14.3 160.5 AM110811F (Solder terminal) AM130811F (Screw terminal) Roller 12.7 dia. x 4.6 : Plastic 23.30.3 4.2 + -00.1 .05 Operating Force OF, max. 3.63 N Release Force RF, min. 1.12 N Pretravel PT, max. 0.4 mm Movement Differential MD, max. 0.05 mm Overtravel OT, min. 3.6 mm Operating Position OP 33.31.2 mm dia . Panel mount cross roller plunger Dimensions and Operating characteristics are the same as those of Panel mount roller plunger type. However, the roller joins the switch body at an angle of 90. CAD Data 90 PT 0.4 max. Roller 12.7 dia. x 4.6 : Plastic 23.30.3 15.5 Nut (2 thick) 4.2 +0.10 -0.05 14.3 AM110812F (Solder terminal) AM130812F (Screw terminal) 160.5 OP 33.31.2 M12 x P1 4.2 + -00.1 .05 Operating Force OF, max. 3.63 N Release Force RF, min. 1.12 N Pretravel PT, max. 0.4 mm Movement Differential MD, max. 0.05 mm Overtravel OT, min. 3.6 mm Operating Position OP 33.31.2 mm dia . Flexible leaf lever CAD Data 49.60.8 Leaf: Stainless steel FP OP 4.8 14.6 AM1101F (Solder terminal) AM1301F (Screw terminal) Operating Force OF, max. 1.47 N Release Force RF, min. 0.14 N Pretravel PT, max. 4 mm Movement Differential MD, max. 1.3 mm Overtravel OT, min. 1.6 mm Operating Position OP 17.50.8 mm Flexible roller leaf lever CAD Data Roller 9.5 dia.x4: Plastic 460.8 Leaf: Stainless steel FP OP 14.6 AM1103F (Solder terminal) AM1303F (Screw terminal) Operating Force OF, max. 1.47 N Release Force RF, min. 0.14 N Pretravel PT, max. 4 mm Movement Differential MD, max. 1.3 mm Overtravel OT, min. 1.6 mm Operating Position OP -5- 28.60.8 mm AECTB8E 201709-T To Be Discontinued Last time buy: September 30, 2018 AM1 (NZ) Basic Switches Hinge lever The photograph is a case of a screw terminal. The dimension is an intersection except a terminal section. Please refer to "TERMINAL STYLE" for the shape and size of terminal section. CAD Data 26.1 Lever: Stainless steel R63.5 4.8 FP OP 20.10.5 AM1501F (Solder terminal) AM1701F (Screw terminal) Operating Force OF, max. 0.69 N Release Force RF, min. 0.14 N Pretravel PT, max. 10 mm Movement Differential MD, max. 1.3 mm Overtravel OT, min. 5.6 mm Operating Position OP 19.10.7 mm Hinge short roller lever CAD Data Roller 9.5 dia.x4: Plastic 26.1 R26.7 OP 20.10.5 FP AM1504F (Solder terminal) AM1704F (Screw terminal) Operating Force OF, max. 1.57 N Release Force RF, min. 0.42 N Pretravel PT, max. 4.5 mm Movement Differential MD, max. 0.7 mm Overtravel OT, min. 2.4 mm Operating Position OP 30.20.4 mm Hinge roller lever CAD Data Roller 9.5 dia.x4: Plastic 26.1 R48.3 OP 20.10.5 FP Operating Force OF, max. 0.98 N Release Force RF, min. 0.2 N Pretravel PT, max. 7.5 mm Movement Differential MD, max. 1.3 mm Overtravel OT, min. 3.6 mm Operating Position OP AM1503F (Solder terminal) AM1703F (Screw terminal) One way types Hinge short roller lever 30.20.7 mm This type is operated only to one direction, not to the reversed direction by the construction of the roller lever, pivoting away from the cam on the return stroke. CAD Data Roller 4.75 dia.x4.75: Plastic 26.1 Non-operating Operating R21.1 27.8 max. OP 20.10.5 AM1544F (Solder terminal) AM1744F (Screw terminal) FP Operating Force OF, max. 2.23 N Release Force RF, min. 0.42 N Pretravel PT, max. 3.5 mm Movement Differential MD, max. 0.4 mm Overtravel OT, min. 1.5 mm Operating Position OP -6- 30.20.4 mm AECTB8E 201709-T To Be Discontinued Last time buy: September 30, 2018 AM1 (NZ) Basic Switches Hinge roller lever This type is operated only to one direction, not to the reversed direction by the construction of the roller lever, pivoting away from the cam on the return stroke. CAD Data Roller 9.5 dia.x4: Plastic 26.1 Operating Non-operating R31 OP 34.1 max. FP 20.10.5 1.67 N Release Force RF, min. 0.42 N Pretravel PT, max. 4.5 mm Movement Differential MD, max. 0.5 mm Overtravel OT, min. 2.4 mm Operating Position OP AM1543F (Solder terminal) AM1743F (Screw terminal) Reversed action types Hinge lever 41.30.4 mm Contact return when actuator operates. (Please refer to "CONTACT FORM".) The photograph is a case of a screw terminal. The dimension is an intersection except a terminal section. Please refer to "TERMINAL STYLE" for the shape and size of terminal section. CAD Data Lever: Stainless steel 18.7 R56 9.1 4.8 FP 20.10.5 16.90.8 AM1531F (Solder terminal) AM1731F (Screw terminal) Operating Force OF, max. OP 5.4 Operating Force OF, max. 1.67 N Release Force RF, min. 0.27 N Pretravel PT, max. 5.0 mm Movement Differential MD, max. 0.9 mm Overtravel OT, min. 5.6 mm 4.2 +0.1 -0.05 dia. hole 4.2 +0.1 -0.05 Operating Position OP 4.50.1 11.9 25.40.1 19.10.8 mm 17.5 11.9 49.2 Hinge short roller lever CAD Data Roller 9.5 dia.x4: Plastic 18.7 R19 OP FP 20.10.5 Operating Force OF, max. 5.30 N Release Force RF, min. 1.67 N Pretravel PT, max. 2.5 mm Movement Differential MD, max. 0.4 mm Overtravel OT, min. 2.0 mm Operating Position OP AM1534F (Solder terminal) AM1734F (Screw terminal) 30.20.5 mm Hinge roller lever CAD Data Roller 9.5 dia.x4: Plastic 18.7 R41 OP 20.10.5 FP Operating Force OF, max. 2.35 N Release Force RF, min. 0.56 N Pretravel PT, max. 3.6 mm Movement Differential MD, max. 0.7 mm Overtravel OT, min. 4.0 mm Operating Position OP 30.20.8 mm AM1533F (Solder terminal) AM1733F (Screw terminal) -7- AECTB8E 201709-T To Be Discontinued Last time buy: September 30, 2018 AM1 (NZ) Basic Switches Oil tight types Hinge lever CAD Data Plunger seal 26.1 Lever: Stainless steel R63.5 4.8 FP 20.10.5 OP Operating Force OF, max. 0.69 N Release Force RF, min. 0.14 N Pretravel PT, max. 10 mm Movement Differential MD, max. 1.5 mm Overtravel OT, min. 5.6 mm Operating Position OP AM1511F (Solder terminal) AM1711F (Screw terminal) 19.10.7 mm Hinge short roller lever CAD Data Plunger seal Roller 9.5 dia.x4: Plastic 26.1 R26.7 20.10.5 OP FP 16.90.8 Operating Force OF, max. 1.67 N Release Force RF, min. 0.42 N Pretravel PT, max. 4.5 mm Movement Differential MD, max. 0.7 mm Overtravel OT, min. 2.4 mm Operating Position OP AM1514F (Solder terminal) AM1714F (Screw terminal) Hinge roller lever 30.20.4 mm The photograph is a case of a screw terminal. The dimension is an intersection except a terminal section. Please refer to "TERMINAL STYLE" for the shape and size of terminal section. CAD Data Plunger seal Roller 9.5 dia.x4: Plastic 26.1 R48.3 OP 20.10.5 16.90.8 FP AM1513F (Solder terminal) AM1713F (Screw terminal) Operating Force OF, max. 0.98 N Release Force RF, min. 0.20 N Pretravel PT, max. 7.5 mm Movement Differential MD, max. 1.3 mm Overtravel OT, min. 3.6 mm Operating Position OP 30.20.7 mm CAUTIONS FOR USE Regarding fastening of switch body In fastening the switch body, use M4 mounting screws to attach switches with the torque 1.5 N*m or less. Panel mount type 1) When mounting the panel, tighten the hex nut for actuator to less than 4.0 N*m. 2) Mounting hole dimensions are as shown below. Soldering operations Perform soldering in less than 3 seconds with maximum 350C iron. Care should be taken not to apply force to the terminals during soldering. We recommend a soldering iron with temperature adjustment in order to prevent poor quality soldering. Please consult us if you intend to use a soldering iron of 60 W or higher. Mounting hole dimensions Panel mount plunger Panel mount roller plunger 12.5 dia. 12.5 dia. 5 13 Environment Avoid using and storing these switches in a location where they will be exposed to corrosive gases, silicon, or high dust levels, all of which can have an adverse effect on the contacts. -8- AECTB8E 201709-T Technical Terminology & Cautions for Use (Detection Switches) TECHNICAL TERMINOLOGY Detection Switches A compact switch equipped with an enclosed micro-gap snapaction contact mechanism that makes a specified motion with a specified force to open/close a circuit, and an actuator outside the enclosure (hereinafter referred to as the switch) Actuator A part of the switch that transmits the received external force to an internal spring mechanism to move the movable contact so that the switch can be opened and closed Actuator stopper A part of the switch to limit the actuator movement in the switch operation direction Rated values Values indicating the characteristics and performance guarantee standards of the snap-action switches. The rated current and rated voltage, for instance, assume specific conditions (type of load, current, voltage, frequency, etc.). Mechanical life The service life when operated at a preset operating frequency without passing electricity through the contacts. (The life test is performed at a switching frequency of 60 times/minute and operating speed of 100 mm/second at the regular cam.) Electrical life The service life when the rated load is connected to the contact and switching operations are performed. (The life test is performed at a switching frequency of 20 times/minute and operating speed of 100 mm/second at the regular cam.) Contact form This refers to the components determining the type of application which make up the electrical input/output circuits in the contact. NC SPDT COM SPST-NC SPST-NO NO NC COM COM NO Terminal symbols COM: Common terminal NC: Normally closed terminal NO: Normally open terminal Insulation resistance Resistance between non-continuous terminals, each terminal and other exposed metal parts and between each terminal and ground. Dielectric Threshold limit value that a high voltage can be applied to a predetermined measuring location for one minute without causing damage to the insulation. Contact resistance This indicates the electrical resistance at the contact part. Generally, this resistance includes the conductor resistance of the spring and terminal portions. Vibration resistance Malfunction vibration ... Vibration range where a closed contact does not open for longer than a specified time due to vibrations during use of the snap-action switches. Shock resistance Shock durability ... Shock range where the mechanical shocks received during snap-action switches transport and installation do not damage the parts or harm the operating characteristics. Malfunction shock ... Shock range where a closed contact does not open for longer than a specified time due to shocks during use of the snap-action switches. -1- AECTB36E 201701-T Technical Terminology & Cautions for Use OPERATING CHARACTERISTIC Definition of operating characteristic The main terminological illustrations and meanings which are used with snapaction switches are as follows. Classification RF OF PT TF Force TT FP OT MD OP RP TTP Symbol Unit Varying display method Operating Force OF N Max. Release Force RF N Min. Totaltravel Force TF N Pretravel PT mm, degree Max. Overtravel OT mm, degree Min. Movement Differential MD mm, degree Max. Totaltravel TT Free Position FP Operating Position OP mm, degree Release Position RP mm, degree The position of the actuator when the traveling contact snaps back from operating position to its original position. Total travel Position TTP mm, degree The stopping position of the actuator after total travel. Terminology Movement Center of mounting holes Position mm, degree mm, degree Starting current The force required to cause contact snap-action. It is expressed terms of force applied to the the actuator. The force to be applied to the the actuator at the moment contact snaps back from operated position to total travel position. Force applied to an actuator required to move from an operating position to a total travel position Distance or agree of the actuator movement from free position to operating position. The distance or degree which the actuator is permitted to travel after actuation without any damage to the switching mechanism. The distance or degree from operating position to release position of the actuator. The migration length or the move angle from the free position to total travel position of actuator Position of the actuator when no force is applied to. The position of the actuator when the traveling contacts snaps with the fixed contact. TECHNICAL NOTES ON MECHANICAL CHARACTERISTICS OF RF FP Contact force The figure at right shows a typical example of activation and contact forces varying with stroke. In the vicinity of the OP and RP, the contact force is diminished, causing chatter and contact bounce immediately before or after reversal. For this reason, use the switch while giving due consideration to this. This also causes the snap action switch to be sensitive to vibration or shock. Operating force Actuation Force and Stroke Adequate stroke setting is the key to high reliability. It is also important that adequate contact force be 'maintained to ensure high reliability. For a normally closed (NC) circuit, the driving mechanism should be set so that the actuator is normally in the free position. For a normally open (NO) circuit, the actuator should be pressed to 70% to 100% of the specified stroke to absorb possible errors. If the stroke is set too close to the operating point (OP), this may cause unstable contact, and in the worst case may cause actuator damage due to inertia of the drive mechanism. It is advisable that the stroke be adjusted with the mounting plate or driving mechanism. RP PT TTP OP MD Changes in Operating Characteristics Exercise design care so that malfunctions will not occur if the operating characteristics vary by as much as 20% from, rated values. In the OF max. 0.98N specification for FS snap-action switches, the allowable max. is 0.98 N x (100%+20%) = 1.18 N In the RF min. 0.15 N min. specification the allowable min. 0.15 N x (100%-20%) = 0.12 N Mechanical Conditions for Type Selection Actuator type should be selected according to activation method, activation speed, activation rate, and activation frequency. 1) An extremely slow activation speed may cause unstable contact transfer, possibly resulting in contact failures or contact fusion. 2) An extremely high activation speed may cause damage to contacts or contact response failure. Stroke Driving Mechanism Use of a driving mechanism which will cause physical impact to the actuator should be avoided. OT NC On FP On reversal On reversal On OTP NO Stroke Bad -2- Good AECTB36E 201701-T Technical Terminology & Cautions for Use TECHNICAL NOTES ON ELECTRICAL CHARACTERISTICS 1) The snap-action switch is designed for AC operations. While it has small contact gaps and no arc absorber, it may be used for low-capacity DC operations. Please refer to the rating of each products 2) For applications with very small switching voltage or current, choose the low-level load type (Au contact). Small current and voltage application range (Au contact) Current (mA) 500 100 50 10 5 2 1 4 8 12 16 20 24 DC voltage (VDC) 3) When selecting a contact type of a snap-action switch to be used for low-level load switching, the following should be noted. Silver contacts' surfaces are prone to be oxidized and form a sulfide film. The switch operates with no problems at the beginning of use. However, as the contact surfaces develop films with time, the film may not be broken by the switching operation, causing a conduction failure. Therefore, please choose the Au contact type for switching a load of 0.1 A or below. 4) Application to Electronic Circuits * The snap-action switch contacts can sustain bounce or chatter when closed. Bounce or chatter can cause noise or pulse count errors when the snap action switch is used in electronic circuits. * If contact bounce or chatter poses problems in the vicinity of the OP and RP, use a suitable absorption network, such as a C/ R network. 5) Check the surge current, normal current and surge duration. 6) Contact resistance given in performance specifications is measured with a voltage drop method using 6 to 8 V DC, 1 A (except for low-level load type). Contact resistance across COM and NC terminals is measured in the free position, while contact resistance across COM and NO terminals is measured in the total travel position. 7) To prevent contact welding failure, be sure to use a serial resistance for each capacitive load. 8) If snap-action switch operation is synchronized with the AC supply phase, this may cause: shortened electrical life, contact fusion failure, contact transfer, or other reliability problems. CAUTIONS IN A CIRCUIT 1) Contact protection is recommended when snap-action switches are used in an inductive load circuit. Circuit diagram Contact for snap-action switch r c R Contact for snap-action switch r c R Contact for snap-action switch diode Can be used for both AC and DC. Impedance of r is nearly equal to impedance of R. C: 0.1 F Wrong Lamp load PL Solenoid load Right Lamp load PL Solenoid load Load connected to same pole Example of wrong power supply connection (connection to different poles of power supply) This may lead to mixed DC and AC. (1) For DC circuits only. R Can be used for both AC and DC. Wrong Load L AC DC Load Induction load Contact for snap-action switch ZNR Varistor Cautions for use (1) r = more than 10 (2) In an AC circuit Impedance of R is to be slightly smaller than impedance of r and c. 2) Do not connect the contacts on individual switches to different type or different poles of the power supply. Examples of power supply connections (connection to different poles) L 3) Avoid circuits which apply voltage between contacts. (This may lead to mixed deposition.) Wrong L 200V 100V -3- AECTB36E 201701-T Technical Terminology & Cautions for Use MOUNTING STATE AND ENVIRONMENT Checking the insulation distance After mounting and wiring, check the insulation distance between terminals and the ground. If the insulation distance is inadequate, mount insulating material between as required. Fastening the snap-action switch body See the Section "CAUTIONS FOR USE" for the individual switch. Position adjustment with effector 1) The effector should be positioned so that direct force is not applied to the plunger or actuator in its free position. The operating force to the plunger should only be applied in a perpendicular direction. 2) Note that the use of the switch as a stopper may cause an operational problem. Switch installation position * Basically, the switch should be installed so that the object to press the switch's plunger or lever can press it down to 70 to 100% of OT of the switch. When determining the position, the tolerance of OP (Operating Position) and other factors should be taken into account. The following describes the case where the strictest tolerance conditions are adopted. * Example: Hinge lever type FS switch Reference values: OP = 8.80.8mm PT = max. 2.8mm OT = min. 1.2mm FP OP TTP PT OT (1) When the switch is not pressed The object to press the lever should not be in contact with the lever. For this purpose, the object should be at a distance from the switch father than the maximum FP (Free Position) value. FP max = OP max + PT max = 9.6 + 2.8 = 12.4 mm max The object should be at a distance of 12.4 mm or more from the mounting hole. (2) Depressed position The plunger/lever should be pressed down to 70% or more of OT (Over Travel). Therefore, the depressed position should be calculated based on the minimum value of OP (Operating Position) and the 70 and 100% of the OT value. OP min - 70% of OT = 8.0 - 0.84 = 7.16 mm OP min - 100% of OT = 8.0 - 1.2 = 6.80 mm The plunger/lever should be pressed down to the position of 6.80 to 7.16 mm from the mounting hole. Soldering precautions For manual soldering, lay the terminals flat (horizontal with the ground) and quickly perform the soldering operation using a soldering iron with the appropriate heat capacity and the proper amount of solder. Take care that the flux does not flow into the switch interior by using a ventilation fan to discharge flux gas and to prevent contact of the switch body with the soldering iron tip. Be careful not to apply force to the lead wires or the terminal portions immediately after soldering. The temperature setting and time conditions vary depending on the product. See the section "CAUTIONS FOR USE" for each product. Wrong Soldering iron tip Correct Avoid using in a silicon atmosphere Avoid using organic silicon rubber, adhesives, sealing compounds, oil, grease, and wires in a silicon atmosphere. Please consult us when using under the following conditions*: 1) Environments where hydrogen sulfide or other corrosive gases are present. 2) Environments where gasoline, thinner or other flammable, explosive gases are present. 3) Dusty environments (for non-seal type snap action switches). 4) The perpendicular operating speed exceeds the allowable operating speed. 5) Switching between different poles. 6) Use in environments not in the prescribed temperature or humidity range. Storage precautions To prevent discoloration due to sulfurization of the terminals (silver- plated), store the switches in a polyethylene bag or other suitable airtight container. -4- AECTB36E 201701-T Technical Terminology & Cautions for Use Usage, storage, and transport conditions (except turquoise switches) During usage, storage, or transportation, avoid locations subject to direct sunlight and maintain normal temperature, humidity, and pressure conditions. The allowable specifications for environments suitable for usage, storage, and transportation are given below. 1) Temperature: The allowable temperature range differs for each switch, so refer to the switch's individual specifications. In addition, when transporting or storing switches while they are tube packaged, there are cases when the temperature may differ from the allowable range. In this situation, be sure to consult the individual specifications. 2) Humidity: The allowable temperature range differs for each switch, so refer to the switch's individual specifications. 3) Pressure: 86 to 106 kPa The humidity range varies with the temperature. Use within the range indicated in the graph below. Humidity, %R.H. 85 Tolerance range (Avoid freezing when (Avoid used at temperatures condensation when lower than 0C 32F) used at temperatures higher than 0C 32F) 5 -40 -40 0 +32 Temperature, C F We reserve the right to modify without notice the materials, internal components, and other parts to improve product quality. Handling precautions When handling the switches, be careful not to drop them on the floor since this may damage them. * Select contact sulfurization (clipping) prevention products (FS and Au-clad double layer contacts) for use with extremely small loads or an environment-resistant Turquoise switch. Others 1) Failure modes of switches include short-circuiting, opencircuiting and temperature rises. If this switch is to be used in equipment where safety is a prime consideration, examine the possible effects of these failures on the equipment concerned, and ensure safety by providing protection circuits or protection devices. In terms of the systems involved, make provision for redundancy in the design and take steps to achieve safety design. 2) The ambient operating temperature (and humidity) range quoted is the range in which the switch can be operated on a continuous basis: it does not mean that using the switch within the rating guarantees the durability performance and environment withstanding performance of the switch. For details on the performance guarantee, check the specifications of each product concerned. +85 +185 (The allowable temperature depends on the switch.) * Condensation will occur inside the switch if there is a sudden change in ambient temperature when used in an atmosphere of high temperature and high humidity. This is particularly likely to happen when being transported by ship, so please be careful of the atmosphere when shipping. Condensation is the phenomenon whereby steam condenses to cause water droplets that adhere to the switch when an atmosphere of high temperature and humidity rapidly changes from a high to low temperature or when the switch is quickly moved from a low humidity location to one of high temperature and humidity. Please be careful because condensation can cause adverse conditions such as deterioration of insulation, coil cutoff, and rust. * Condensation or other moisture may freeze on the switch when the temperatures is lower than 0C 32F. This causes problems such as sticking of movable parts or operational time lags. * The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time. * Storage for extended periods of time (including transportation periods) at high temperatures or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported. * In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. -5- AECTB36E 201701-T Technical Terminology & Cautions for Use Types of actuators Shape Pretravel (PT) Overtravel (OT) Operating Force (OF) Vibration Shock Pin plunger Small Small Large Outstanding Appropriate for linear short-stroke action. Pin plunger acts directly on snap action mechanism, enabling high-precision positioning. Amount of movement after operation is smallest among all of the actuators, however, so reliable stopper is required. Spring small plunger Small Medium Large Excellent Used in much the same way as the pin plunger, but is easier to use because the amount of movement after operation is larger. Spring short plunger Small Medium Large Good Pin plunger is short, with large plunger diameter that makes centering easier. Like small spring plunger, amount of movement after operation is large. Panel attachment plunger Small Large Large Good Secured to panel with hex or lock nut; used as manual or mechanical plunger. Amount of movement after operation is extremely large and operation point can be adjusted by changing attachment position. Can be used in combination with low-speed cam. Panel attachment roller plunger Small Large Large Possible This is the panel attachment type with a roller, and can be used with fastmoving cams and dogs.. Hinge lever Large Medium Small Possible Little force required for operation. Appropriate for use with low-speed cams and dogs; has large stroke. Lever available in various shapes to fit operating unit. Simulated roller lever Large Medium Small Possible Tip of hinge lever is bent into a semi-circle, enabling use as a simple roller type. Leaf lever Large Large Small Excellent Play in lever is used to assure maximum stroke. Construction provides for space where lever is attached, for outstanding resistance to freezing. Hinge roller lever Large Medium Small Possible This is a hinge lever with a roller, and can be used with high-speed cams and dogs. The force required for pin plunger action is lighter than that of the lever, and the stroke is longer. One way action hinge roller lever Medium Medium Medium Possible This is hinge roller lever type, and can operate in relation to an operating unit from a one way direction, but the roller is bent from the opposite direction and cannot move. This can be used to prevent reverse-direction action. Leaf spring Medium Medium Medium Good This has a leaf spring with offset yield force and has a large stroke. Ideal for driving low-speed cams and cylinders. Fulcrum is fixed for high precision. To prevent leaf damage, movement after operation must be within specified value. Roller leaf spring Medium Medium Medium Good This is a leaf spring with a roller, and can be used with high-speed cams. (OC reversed action groove type) Reverse-action hinge lever Large Small Medium Excellent This is used for low-speed, low-torque cams. The lever comes in various shapes to fit the operating body. (OC reversed action groove type) Reverse-action hinge roller lever Medium Medium Medium Excellent This is a reverse-action hinge lever with a roller and is appropriate for cam operation. Excellent resistance to vibration and impact when not engaged. Excellent This is a shorter version of the reverse-action hinge lever with a roller and has a larger action force, but is appropriate for cam operation with a short stroke. Excellent resistance to vibration and impact when not engaged. Classification (OC reversed action groove type) Reverse-action hinge roller short lever Small Medium Large Features -6- The plunger is constantly pressed down by a coiled spring, and operating the lever induces reverse action. Because the plunger is depressed when not engaged, vibration and shock resistance are excellent. Pressing the plunger too far does not cause abnormal force to be applied to the switch mechanism, so a stable service life is assured. AECTB36E 201701-T