GNT200 Front End Series 200W AC/DC Universal Input Power Supply 2 Year Warranty *Wide Range Input 100-240 VAC with PFC *Inhibit, Enable, Power Signals and Remote Sense Standard *Power Density 10-13W/in *Compact (3.0" x 5.0" x 1.25") *High Efficiency: 90% Typical *Main Output and Two Auxiliary Outputs *Conducted EMI meets Class B nd *Approved to CSA/EN/IEC/UL 60950-1, 2 Edition for ITE *Approved to EN/IEC/UL60601-1 and CSA 22.2 No. 601 for Medical *Also Available in Class II (G2T200) *CB Report Available (for IEC60601-1 standard) Specifications AC Input Input Current Inrush Current Input Fuses All Specifications are typical at nominal input, full load at 25C unless otherwise stated. 100-240VAC, 50/60 Hz, single phase 80-270VAC, 45-65 Hz max 120VAC: 3A. 230VAC: 1.5A Limited by internal thermistor. The inrush at 240Vac, averaged over the first AC half-cycle under cold start conditions will not exceed 38A. F1 and F2, 4A/250V Power Factor Leakage Current Output Power Peak Output Power Output Voltage Voltage Adjustability Minimum Load Total Regulation 0.98 typical, 0.96 minimum 100A at 120VAC NC, 400A at 264VAC, SFC 200W continuous with 200lfm airflow See chart for convection ratings 240W for 1 minute, 10% duty cycle See chart Adjustable potentiometer, capable of 5% change from the nominal setting Not required See chart Transient Response 500s to 1%, 50% load step, i/t < 0.2A/s Maximum voltage deviation is 3.5% Temperature Coefficient 0.03% per C typical on all units Operating Altitude -500 to 10,000 ft Non-operating Altitude Vibration -500 to 40,000 ft 5 Hz - 500 Hz, 5 grms Turn On Time 500 ms max Hold-up Time See chart Thermal Considerations Over/Undershoot Overload Protection Cycling type, 250W nominal limit Overvoltage Protection Ripple and Noise See chart 1% pk-pk max., 20MHz BW, 0.1F and 10 F caps on probe CSA/EN/IEC/UL 60950-1, 2nd Edition ITE Safety Standards Medical Safety Standards Switching Frequency EN/IEC/UL 60601-1, CSA22.2 No. 601-1 Output: 195kHz 12kHz, PFC: 130kHz MTBF 300K hours per Telcordia Overtemperature Protection Efficiency Keeping the following components below these temps indicates sufficient cooling: Q1: 90C max., T4: 110C max 3.5% max Automatic 90% typical at 230VAC, 87% typical at 120VAC Operating Temperature 0 to 70C (see chart) Storage Temperature Relative Humidity -40 to +85C 5% to 95%, non-condensing Shock MIL-STD-810E, 516.4 part IV Model Number Key GNT 2 XX X G RoHS Com pliant Enclosure Options: Blank - no enclosure; F = Fan Cover w ith "U" channel; L = L bracket, no cover; T = Slotted cover w ith U channel; U = U channel, no cover. Output Voltage: (See m odels chart below ) Output Pow er (Watts): "2" = 200W Product Fam ily (GNT = Class I input, G2T = Class II input) ______________________________________________________________________________________________________________________________ 1 of 3 SL Power Electronics Corp * 6050 King Drive Ventura, CA 93003 * Phone 805.486.4565 * Fax 858.712.2040 * Email: info@slpower.com * www.slpower.com GNT200 Front End Series 200W AC/DC Universal Input Power Supply Model Number GNT212G GNT215G GNT218G GNT224G GNT228G GNT236G GNT248G Notes: 1. 2. 3. Volts (V) 2 Year Warranty Output Current 100Vac Convection 240Vac Convection 90-270VAC Fan Cooled 12V 15V 18V 24V 28V 36V 48V 8.3A 6.7A 5.6A 4.2A 3.6A 2.5A 1.9A 12.5A 10.0A 8.3A 6.3A 5.4A 3.9A 2.9A 16.7A 13.3A 11.1A 8.3A 7.1A 5.6A 4.2A Ripple & Noise 120mV 150mV 180mV 240mV 280mV 360mV 480mV Total Regulation 2% 2% 2% 2% 2% 2% 2% OVP Threshold 14.0 1V 17.6 1V 20.8 1V 27.5 1V 32.0 1V 42.0 1V 55.0 1V When the input voltage is <90Vac, derate output power by approximately 20%. Convection ratings shown are for 40C ambient. Derate load 2.5%/C to 70C. Fan cooled rating of 200W @ 50C requires 200lfm of airflow over the unit. General Specifications (continued from p. 1) Signals PS Off: Inhibit: Pwr OK: Pwr OK: DC OK: Aux. Output: Aux. Output: Conducted Emissions: Line Freq. Harmonics: Voltage Fluctuations: Static Discharge: RF Field Susceptability: Fast Transients/Bursts EFT: Surge Susceptability: Conducted Immunity: Power Freq. Mag. Field: Voltage Dips Immunity: EMC/EMI Compliance High to Inhibit Low to Inhibit Goes high 100ms to 200 ms after DC OK signal Power fail low - 4ms warning High when output is >92% of nominal 12Vdc @ 250mA 5Vdc @ 100mA, always on EN55011/22, Class B; FCC Class B EN61000-3-2 Class A EN61000-3-3 EN61000-4-2 EN61000-4-3 3 V/meter EN61000-4-4, 2 kV, 5 kHz - criteria B EN61000-4-5, criteria B EN61000-4-6, 3 Vrms EN61000-4-8, 3 A/m EN61000-4-11 Contact factory GNT200 Series Typical Holdup & Warning Time vs Output Power 200 180 160 Time (milliSeconds) 140 120 100 Tholdup (mS) Twarning (mS) 80 60 40 20 0 200 150 100 Output Power 50 25 ______________________________________________________________________________________________________________________________ 2 of 3 SL Power Electronics Corp * 6050 King Drive Ventura, CA 93003 * Phone 805.486.4565 * Fax 858.712.2040 * Email: info@slpower.com * www.slpower.com GNT200 Front End Series 200W AC/DC Universal Input Power Supply 2 Year Warranty Mounting Options GNT200 WEIGHT: 0.68 Lbs. (350g) CONNE CTOR INFORM ATION J1: AC INPUT - A MP# 640445-3 PIN 1: AC LINE PIN 2: AC NEUT RAL J2: DC OUTP UT PIN 1: PIN 2: PIN 3: PIN 4: PIN 5: PIN 6: - AM P# 64044 5-6 +V out +V out +V out COMMON COMMON COMMON Q1 T4 J3: FAN OUT PUT - AM P# 6404 56-2 PIN 1: +12Vdc @ 0.25A PIN 2: FAN RTN (COMMO N) J4: SIGN ALS - MOLE X 22-05-7085 PIN 1: PS OFF PIN 2: INHI BIT PIN 3: PW R O K PIN 4: DC OK PIN 5: SIGN AL RTN (COMMON) PIN 6: +5Vdc @ 0.1A PIN 7: -SE NSE PIN 8: +SE NSE J1: MOLE X 09-50-3031, PI NS: 08-52-0112 J2: MOLE X 09-50-3061, PI NS: 08-52-0112 J3: AMP 1375 820-2, PINS : 1375813 -3 J4: MOLE X 50-37-5083, PI NS: 08-70-1040 MATING CO NNECTORS: GNT200 Output Power vs. Line Voltage & Temperature 200 5 0 C w / 2 0 0 lfm a irfl o w 180 2 5 C c o n v e c tio n Power Rating (Watts) 160 140 120 5 0 C c o n v e c ti o n 4 0 C c o n v e c ti o n 100 80 60 40 20 0 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 In p u t V o lts AC Data Sheet (c) 2011 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. Rev. 2-17-2011 ______________________________________________________________________________________________________________________________ 3 of 3 SL Power Electronics Corp * 6050 King Drive Ventura, CA 93003 * Phone 805.486.4565 * Fax 858.712.2040 * Email: info@slpower.com * www.slpower.com