Document Number 7881
Issue 1
BSW67A
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Parameter Test Conditions Min. Typ. Max. Unit
Parameter Test Conditions Min. Typ. Max. Unit
ELECTRICAL CHARACTERISTICS (Tcase = 25°C unless otherwise stated)
IC= 10mA IB= 0
IC= 100μAI
E= 0
IE= 100μAI
C= 0
VCB = 60V IE= 0
VCB = 60V IE= 0
Tamb = 150°C
IC= 0.1A IB= 0.01A
IC= 0.5A IB= 0.05A
IC= 1.0A IB= 0.15A
IC= 0.1A IB= 0.01A
IC= 0.5A IB= 0.05A
IC= 1.0A IB= 0.15A
IC= 0.1A VCE = 5V
IC= 0.5A VCE = 5V
IC= 1.0A VCE = 5V
V(BR)CEO* Collector – Emitter Breakdown Voltage
V(BR)CBO* Collector – Base Breakdown Voltage
V(BR)EBO* Emitter – Base Breakdown Voltage
ICBO Collector Cut-off Current
VCE(sat)* Collector – Emitter Saturation Voltage
VBE(sat)* Base – Emitter Saturation Voltage
hFE* DC Current Gain
120
120
6
0.1
50
0.15
0.5
1.0
0.9
1.1
1.2
40
30
15
V
V
V
μA
V
V
—
fTTransition Frequency
Cobo Output Capacitance
Cibo Input Capacitance
ton Turn–On Time
toff Turn–Off Time
IC= 100mA VCE = 20V f = 35MHz
VCB = 10V IE= 0 f = 1.0MHz
VEB = 0 IE= 0 f = 1.0MHz
IC = 0.5A VCC = 20V
IB1 =- IB2 = 0.05A
50
20
300
0.3
1.0
MHz
pF
pF
μs
t* Pulse test tp = 300μs , δ ≤ 1.5%
DYNAMIC CHARACTERISTICS (Tcase = 25°C unless otherwise stated)