Power Relay K (Sealed)
Automotive Relays
PCB Single Relays
n Limiting continuous current 45A
n Wide voltage range
n 24VDC coil versions available
Typical applications
ABS control, blower fans, car alarm, cooling fan, engine control, fuel pump,
hazard warning signal, heated front screen, heated rear screen, ignition,
lamps front/rear/fog light, interior lights, main switch/supply relay, seat
control, seatbelt pretensioner, sun roof, turn signal, valves, window lifter,
wiper control.
Contact Data
Typical applications Resistive/inductive Resistive/inductive Indicator lamps Headlights, Headlights
loads loads capacitive loads capacitive loads
Contact arrangement 1 form A, 1 NO 1 form C, 1 CO 1 form A, 1 NO 1 form A, 1 NO 1 form C, 1 CO
Rated voltage 12VDC 12VDC 12VDC 12VDC 12VDC
A/B (NO/NC) A/B (NO/NC)
Rated current 45A 45/30A 30A 40A 40/25A
Limiting continuous current
23°C 45A 45/30A 30A 40A 40/25A
85°C 30A 30/25A 25A 25A 25/20A
Limiting making current1) 100A 100/30A 120A3) 180A 180/60A
Limiting breaking current2) 60A 60/30A 60A 60A 60/30A
Contact material AgNi0.15 AgNi0.15 AgSnO2 AgSnO2 AgSnO2
Min. recommended contact load 1A at 5VDC4)
Initial voltage drop, at 10A, typ./max. 20/300mV
Operate/release time typ. 5/3ms5)
Electrical endurance >2x105 ops. >2x105 ops. >2.2x106 ops. >105 ops. >105 ops.
at 13.5VDC, 40A at 13.5VDC, 40A up to 8x21W up to 4x60W up to 4x60W
Mechanical endurance, DC coil >107 ops.
1) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5VDC for 12VDC or 27VDC for 24VDC load voltages.
2) For a load current duration of maximum 3s for a make/break ratio of 1:10.
3) Corresponds to a peak inrush current on initial actuation (cold filament).
4) See chapter Diagnostics of Relays in our Application Notes or consult the internet at http://relays.te.com/appnotes/
5) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher
risk of contact tack welding.
Max. DC load breaking capacity
Load limit curve 1: arc extinguishes, during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
F076_fcw2b
Does not take into account
the temperature rise due to
the contact current
E = pre-energization
TE0555-6
Does not take into account the temperature rise due to the contact current
E = pre-energization
Coil operating range