First Edition March 27, 1997 LCD Module Specification Approved by Production Div. Checked by Quality Assurance Div. Checked by Design Engineering Div. Prepared by Production Div. Final Revision ******* Type No. Table of Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. General Specifications .............................................................................2 Electrical Specifications...........................................................................3 Optical Specifications ..............................................................................7 I/O Terminal.............................................................................................9 Test..........................................................................................................11 Appearance Standards............................................................................12 Code System of Production Lot ..........................................................15 Type Number .........................................................................................15 Applying Precautions .............................................................................15 Handling Precautions .............................................................................16 Revision History Rev. Date DMF-50202N Page (AA) No.97-0074 Comment OPTREX OPTREX CORPORATION Page 1/16 1.General Specif ications Operating Temp. min. 0 max. 50 Storage Temp. min. -20 max. 60 Dot Pixels 128 (W) x 64 (H) dots Dot Size 0.40 (W) x 0.56 (H) mm Dot Pitch 0.44 (W) x 0.60 (H) mm Viewing Area 62.0 (W) x 44.0 (H) mm Outline Dimensions 95.0 (W) x 58.0 (H) x 8.7 max. (D) mm LCD Type NRD-7496 ( STN / Neutral-mode / Reflective ) Viewing Angle 6:00 Data Transfer Serial data transfer Backlight None Drawings Dimensional Outline DMF-50202N (AA) No.97-0074 OPTREX UE-33929A OPTREX CORPORATION Page 2/16 2.Electrical Specif ications 2.1.Absolute Maximum Ratings VSS=0V Parameter Supply Voltage Symbol Conditions Min. Max. Units VDD-VSS -0.3 7.0 V VDD-VEE 0 30.0 V VI -0.3 VDD+0.3 V (Logic) Supply Voltage (LCD Drive) Input Voltage 2.2.DC Characteristics Ta=25, VSS=0V Parameter Supply Voltage Symbol Conditions Min. Typ. Max. Units VDD-VSS 4.5 5.5 V (Logic) Supply Voltage VDD-VEE Shown in 3.1 V (LCD Drive) High Level VIH VDD=5.0V10% VDD-0.8 VDD V VIL VDD=5.0V10% 0 0.8 V VOH IOH=-0.5mA VDD-0.3 VDD V VOL IOL=0.5mA 0 0.3 V IDD VDD-VSS=5.0V 1.0 1.5 mA IEE VDD-VEE=13.2V 0.8 1.2 mA Input Voltage Low Level Input Voltage High Level Output Voltage Low Level Output Voltage Supply Current DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 3/16 2.3.AC Characteristics VDD=5.0V10% Parameter Clock Pulse High Level Width Clock Pulse Low Level Width Clock Pulse Rise/Fall Time Latch Pulse High Level Width Latch Pulse Rise Time Latch Pulse Fall Time Data Setup Time Data Hold Time Frame Data Setup Time Frame Data Hold Time Symbol Min. Max. Units tCWH tCWL tr, tf tLW tLRP tLFP tDSU tDHD tFDS tFDH 95 ns 95 ns 30 ns 40 ns 20 ns 40 ns 20 ns 40 ns 30 ns 50 ns tLW CP1 tLRP tLFP tCWL CP2 tCWH tr tf tDSU tDHD D1 tFDS tFDH FLM DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 4/16 2.4.Timing Chart T=0.223ms typ. CP1 CP2 D1 SEG SEG SEG SEG 127 128 1 2 #1 DATA SEG SEG SEG SEG 127 128 1 2 FLM CP1 (Reduction) 64xT FLM (Reduction) M 2.5.Comparison of Display and Data SEG1 #1 D1 SEG128 D1 D1 D1 D1 D1 TOP VIEW #64 DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 5/16 2.6.Power Supply ON/OFF Sequence 2.6.1.ON Sequence SIGNAL LEVEL VDD VSS VDD 0t SIGNAL VDD VSS 0t VDD VSS VEE VEE 2.6.2.OFF Sequence LEVEL SIGNAL VDD VSS VDD 0t VDD VSS 0t SIGNAL VDD VSS VEE VEE Please maintain the above sequence when turning on and off the power supply of the module. If VEE is supplied to the module while alternate signal for LCD driving (M) is unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module. DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 6/16 3.Optical Specif ications 3.1.LCD Driving Voltage Parameter Symbol Recommended LCD Driving Voltage VDD-VEE Conditions Min. Typ. Max. Units Ta= 0 15.4 V Ta=25 12.3 13.2 14.1 V Note 1 Ta=50 10.9 V Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range. Note 1 : 3.2.Optical Characteristics Ta=25, 1/64 Duty, 1/9 Bias, VD=13.2V (Note 4), = 0, = Parameter Contrast Ratio Note 1 Symbol Conditions Min. Typ. Max. CR = 0, = 4 Viewing Angle Response Time Units Shown in 3.3 Note 2 r 160 240 ms Decay Note 3 d 160 240 ms Rise Note 1 : Contrast ratio is definded as follows. CR = LOFF / LON LON : Luminance of the ON segments LOFF : Luminance of the OFF segments Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 : Definition of Driving Voltage VD Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is definded as follows. VD = (Vth1+Vth2) / 2 Vth1 : The voltage VO-P that should provide 50% of the satulation level in the luminance at the segment which the ON signal is applied to. Vth2 : The voltage VO-P that should provide 50% of the satulation level in the luminance at the segment which the OFF signal is applied to. VO-P ( B-2 )x VO-P / B 1 / ( fFx A ) 1 / fF ON SIGNAL DMF-50202N (AA) No.97-0074 OFF SIGNAL OPTREX OPTREX CORPORATION Page 7/16 3.3.Definition of Viewing Angle and Optimum Viewing Area Point shows the point where contrast ratio is measured. : = 0, = Driving condition : 1/64 Duty, 1/9 Bias, VD=13.2V, fF=70Hz 90 45 135 180 10 20 30 40 50 90 (= 0 180 225 0 315 270 270 Area shows typ. CR2 3.4.System Block Diagram Temperature Chamber Rotation Table (,) Photometer #1980A WB LCD Optical Fiber Control Unit & Computer Waveform Generator Halogen bulb DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 8/16 4.I/O Terminal 4.1.Pin Assignment CN1 No. Symbol Level Function 1 FLM H/L First Line Marker 2 CP1 HL Data Latch Signal 3 CP2 HL Clock Signal for Shifting Data 4 M H/L Alternate Signal for LCD Drive 5 D1 H/L Display Data 6 VDD Power Supply for Logic 7 VSS Power Supply (0V, GND) 8 VEE Power Supply for LCD Drive 4.2.Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. VDD VEE VDD (+Voltage) Tr R1 VR MODULE R2 VEE (-Voltage) VSS VSS (0V) R1+R2+VR=1020K Tr=2SA1202 or equivalent DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 9/16 4.3.Block Diagram 64 Row Driver T6A40 x 1 or equivalent FLM LCDP 128 x 64 dots 2 128 2 Column Driver T6A39 x 2 or equivalent CP1, M CP2 D1 VDD FG VSS Bias Circuit To LSI VEE DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 10/16 5.Test No change on display and in operation under the following test condition. No. Parameter Conditions Notes 1 High Temperature Operating 502, 96hrs (operation state) 2 Low Temperature Operating 02, 96hrs (operation state) 3 3 High Temperature Storage 602, 96hrs 4 4 Low Temperature Storage -202, 96hrs 3, 4 5 Damp Proof Test 402, 9095%RH, 96hrs 3, 4 6 Vibration Test Total fixed amplitude : 1.5mm 5 Vibration Frequency : 1055Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state. F E G B D C A 60cm Concrete Surface Dropping method corner dropping A corner : once Edge dropping B,C,D edge : once Face dropping E,F,G face : once Note 1 : Unless otherwise specified, tests will be conducted under the following condition. Temperature : 205 Humidity : 655% Note 2 : Unless otherwise specified, tests will be not conducted under functioning state. Note 3 : No dew condensation to be observed. Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. Note 5 : Vibration test will be conducted to the product itself without putting it in a container. DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 11/16 6.Appearance Standards 6.1.Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45against perpendicular line. 45 6.2.Definition of applicable Zones A Zone Bezel Flame B Zone C Zone A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 12/16 6.3.Standards No. 1 Parameter Criteria Black and (1) Round Shape White Spots, Foreign Substances Zone Acceptable Number Dimension (mm) A B C D 0.1 * * * 0.1 D 0.2 5 5 * 0.2 D 0.3 0 1 * 0.3 D 0 0 * D = ( Long + Short ) / 2 * : Disregard (2) Line Shape Zone X(mm) Acceptable Number Y(mm) A B C 0.02W * * * 2.0L 0.03W 3 3 * 1.0L 0.04W 1 2 * 1.0L 0.05W 0 2 * 0.05W X : Length Y : Width In the same way (1) * : Disregard Total defects shall not exceed 5. 2 Air Bubbles (between glass & polarizer) Zone Dimension (mm) Acceptable Number A B C * * * 0.15 D 0.3 2 3 * 0.3 D 0.5 1 2 * 0.5 D 1.0 0 1 * D 0.15 * : Disregard Total defects shall not exceed 3. DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 13/16 No. 3 Parameter Criteria The Shape of Dot (1) Dot Shape (with Dent) 0.15 As per the sketch of left hand. (2) Dot Shape (with Projection) Should not be connected to next dot. (3) Pin Hole X (X+Y) / 20.2mm Y (Less than 0.1mm is no counted.) Total defects shall not exceed 5. 4 Polarizer Scratches Not to be conspicuous defects. 5 Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not defective. 6 Color Variation DMF-50202N (AA) Not to be conspicuous defects. No.97-0074 OPTREX OPTREX CORPORATION Page 14/16 7.Code System of Production Lot The production lot of module is specified as follows : Factory Number Factory Code (Alphabet) Production Week (15) Production Month (19, X, Y, Z) Production Year (Lower 2 digits) 8.Type Number The type number of module is specified on the back of module as follows : Etching or Printing 9.Applying Precautions Please contact us when questions and/or new problems not specified in this specifications arise. DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 15/16 10.Handling Precautions Operex Products are designed for use in ordinary electronic devices such as business machines, telecommunications equipment, measurement devices and etc.. Optrex Products are not designed, intended, or authorized for use in any application in which the failure of the product could result in a situation where personal injury or death may occur. These applications include, but are not limited to, life-sustaining equipment, nuclear control devices, aerospace equipment, devices related to hazardous or flammable materials, etc. (If Buyer intends to purchase or use the Optrex Products for such unintended or unauthorized applications, Buyer must secure prior written consent to such use by a responsible officer of Optrex Corporation.) Should Buyer purchase or use Optrex Products for any such unintended or unauthorized application (without such consent), Buyer shall indemnify and hold Optrex and its officers, employees, subsidiaries, affiliates and distributors harmless against all claims, costs, damages and expenses, and reasonable attorney's fees, arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Optrex was negligent regarding the design or manufacture of the part. 1) LCD may be broken because it is made of glass. 2) Polarizer is a soft material and can easily be scratched. 3) Please avoid static electricity. Please be sure to ground human body and electric appliances during work. It is preferable to use conductive mat on table and wear cotton clothes or conduction processed fiber. Synthetic fiber is not recommended. Please slowly peel off protective film, because static electricity may be charged. 4) If it is necessary to store LCD modules for a long time, please comply with the following procedures. If storage condition is not satisfactory, display (especially polarizer) may be deteriorated or soldering I/O terminals may become difficult (some oxide is generated at I/O terminals plating). Store as delivered by Optrex If you store as unpacked, put in anti-static bag, seal its opening and store where it is not subjected to direct sunshine nor fluorescent lamp. Store at temperature 0 to +35 and at low humidity. Please refer to our specification sheets for storage temperature range and humidity condition. 5) The module does not contain excess current limiter. Please design the limiter to cut excess current in your power supply circuit. 6) Liquid crystal may be leaked when display is broken. Never taste it. If your hands or clothes touch it, please immediately wash using soap. Optrex shall not be responsible for any infringement of industrial property rights of third parties in any country arising out of the application or use of Optrex Products, except which directly concern the structure or production of such products. DMF-50202N (AA) No.97-0074 OPTREX OPTREX CORPORATION Page 16/16