(R) 114, 115, and 117 True-rms Multimeters Users Manual PN 2572573 July 2006, Rev. 1, 2/07 (c) 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke's behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. 11/99 Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands True-rms Multimeters Introduction The Fluke Model 114, Model 115, and Model 117 are battery-powered, true-rms multimeters (hereafter "the Meter") with a 6000-count display and a bar graph. This manual applies to all three models. All figures show the Model 117. These meters meet CAT III IEC 61010-1 2nd Edition standards. The IEC 61010-1 2nd Edition safety standard defines four measurement categories (CAT I to IV) based on the magnitude of danger from transient impulses. CAT III meters are designed to protect against transients in fixed-equipment installations at the distribution level. Contacting Fluke To contact Fluke, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore +65-738-5655 Anywhere in the world: +1-425-446-5500 Visit Fluke's web site at www.fluke.com. Register your Meter at register.fluke.com. Unsafe Voltage To alert you to the presence of a potentially hazardous voltage, the Y symbol is displayed when the Meter measures a voltage 30 V or a voltage overload (OL) condition. When making frequency measurements >1 kHz, the Y symbol is unspecified. Test Lead Alert XWWarning Personal injury or damage to the Meter can occur if you attempt to make a measurement with a lead in an incorrect terminal. To remind you to check that the test leads are in the correct terminals, LEAd is briefly displayed and an audible beep sounds when you move the rotary switch to or from any A (Amps) position. 1 114, 115, and 117 Users Manual Safety Information A "XWWarning" statement identifies hazardous conditions and actions that could cause bodily harm or death. A "WCaution" statement identifies conditions and actions that could damage the Meter or the equipment under test. To avoid possible electric shock or personal injury, follow these guidelines: * Use the Meter only as specified in this manual or the protection provided by the Meter might be impaired. * Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. * Always use proper terminals, switch position, and range for measurements. * Verify the Meter's operation by measuring a known voltage. If in doubt, have the Meter serviced. * Do not apply more than the rated voltage, as marked on Meter, between terminals or between any terminal and earth ground. * Use caution with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. These voltages pose a shock hazard. * Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance. * Do not use the Meter around explosive gas or vapor. * When using test leads or probes, keep your fingers behind the finger guards. * Only use test leads that have the same voltage, category, and amperage ratings as the meter and that have been approved by a safety agency. * Remove test leads from Meter before opening the battery door or Meter case. 2 True-rms Multimeters Safety Information * * * * * * Comply with local and national safety requirements when working in hazardous locations. Use proper protective equipment, as required by local or national authorities when working in hazardous areas. Avoid working alone. Use only the replacement fuse specified or the protection may be impaired. Check the test leads for continuity before use. Do not use if the readings are high or noisy. Do not use the Auto Volts function to measure voltages in circuits that could be damaged by this function's low input impedance (3 k)(114 and 117 only). Symbols B AC (Alternating Current) F DC (Direct Current) T Double Insulated X Hazardous voltage W Important Information; Refer to manual N Battery (Low battery when shown on the display.) J Earth ground Do not dispose of this product as unsorted municipal waste. Contact Fluke or a qualified recycler for disposal. D AC and DC ~ I Fuse 3 114, 115, and 117 Users Manual Display 8 VoltAlert 6 7 5 9 4 10 11 3 2 12 1 16 14 15 17 13 18 edy02f.eps No. A Symbol w B 4 Meaning The Meter is in the VoltAlertTM non-contact voltage detect mode. Model 117 s The Meter function is set to Continuity. 114, 115, & 117 C R The Meter function is set to Diode Test 115 & 117 D O Input is a negative value. 114, 115, & 117 E Y X Unsafe voltage. Measured input voltage 30 V, or voltage overload condition (OL). 114, 115, & 117 True-rms Multimeters Display F K G M VWX (Red LED) H I J K LoZ nF mVA Mk kHz DC AC Display hold enabled. Display freezes present reading. MIN MAX AVG mode enabled. Maximum, minimum, average or present reading displayed Voltage presence through the non-contact VoltAlert sensor 114, 115, & 117 114, 115, & 117 117 The Meter is measuring voltage or capacitance with a low input impedance. 114, 115 & 117 Measurement units. 114, 115, & 117 Direct current or alternating current 114, 115 & 117 Battery low warning. 114, 115, & 117 M N 610000 mV Indicates the Meter's range selection. 114, 115, & 117 N (Bar graph) Analog display. 114, 115, & 117 O The Meter is in the Auto Volts function. Autoranging. The Meter selects the range for best resolution. Manual ranging. User sets the Meter's range. Bar graph polarity 114 & 117 114, 115, & 117 114, 115, & 117 P Auto Volts Auto Manual + Q 0L W The input is too large for the selected range. 114, 115, & 117 R LEAd W Test lead alert. Briefly displayed whenever the Meter's function switch is rotated to or from any A position. 115 & 117 L 114, 115, & 117 5 114, 115, and 117 Users Manual Terminals 1 A COM V 3 10 A FUSED 2 edy01f.eps No. Description A B Input terminal for measuring ac and dc current to 10 A. Common (return) terminal for all measurements. 115 & 117 114, 115, & 117 C Input terminal for measuring voltage, continuity, resistance, capacitance, frequency and testing diodes. 114, 115, & 117 bAtt CAL Err EEPr Err F11 Err 6 Model Error Messages Battery must be replaced before the Meter will operate. Calibration required. Meter calibration is required before the Meter will operate. Internal error. The Meter must be repaired before it will operate. Internal error. The Meter must be repaired before it will operate. True-rms Multimeters Rotary Switch Positions Rotary Switch Positions Switch Measurement Function Position Automatically selects ac or dc volts based on the sensed input with a low x impedance input. AC voltage from 0.06 to 600 V. e Hz (button) Frequency from 5 Hz to 50 kHz. D l s R S j Hz (button) I w DC voltage from .001 V to 600 V. AC voltage from 6.0 to 600 mV, dc-coupled. DC voltage from 0.1 to 600 mV. Model 114 & 117 114, 115 & 117 115 & 117 114, 115 & 117 114, 115 & 117 Ohms from 0.1 to 40 M. 114, 115 & 117 Continuity beeper turns on at < 20 and turns off at >250 . 114, 115 & 117 Diode Test. Displays OL above 2.0 V. 115 & 117 Farads from 1 nF to 9999 F. 115 & 117 AC current from 0.1 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off). >10.00 A display flashes. >20 A, OL is displayed. DC-coupled. Frequency from 45 Hz to 5 kHz. DC current from 0.001 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off). >10.00 A display flashes. >20 A, OL is displayed. 115 & 117 Non-contact sensing of ac voltage. 115 & 117 117 Note: All ac functions and Auto-V LoZ are true-rms. AC voltage is ac-coupled. Auto-V LoZ, AC mV and AC amps are dc-coupled. 7 114, 115, and 117 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range change, or button press for 20 minutes. Pressing any button or turning the rotary switch awakens the Meter. To disable the Sleep mode, hold down the g button while turning the Meter on. The Sleep mode is always disabled in the MIN MAX AVG mode. Display HOLD MIN MAX AVG Recording Mode The MIN MAX AVG recording mode captures the minimum and maximum input values (ignoring overloads), and calculates a running average of all readings. When a new high or low is detected, the Meter beeps. * Put the Meter in the desired measurement function and range. * Press p to enter MIN MAX AVG mode. * Mand MAX are displayed and the highest reading detected since entering MIN MAX AVG is displayed. * Press p to step through the low (MIN), average (AVG), and present readings. * To pause MIN MAX AVG recording without erasing stored values, press f. K is displayed. * To resume MIN MAX AVG recording, press fagain. * To exit and erase stored readings, press p for at least one second or turn the rotary switch. 1. Press fto activate Display HOLD. (K is displayed.) 8 XWWarning To avoid electric shock, when Display HOLD is activated, be aware that the display will not change when you apply a different voltage. In the Display HOLD mode, the Meter freezes the display. 2. To exit and return to normal operation, press f or turn the rotary switch. Backlight Press Q to toggle the backlight on and off. The backlight automatically turns off after 40 seconds. To disable backlight auto-off, hold down Q while turning the Meter on. Manual and Autoranging The Meter has both Manual and Autorange modes. * In the Autorange mode, the Meter selects the range with the best resolution. * In the Manual Range mode, you override Autorange and select the range yourself. True-rms Multimeters Power-Up Options When you turn the Meter on, it defaults to Autorange and Auto is displayed. 1. To enter the Manual Range mode, press q. Manual is displayed. 2. In the Manual Range mode, press qto increment the range. After the highest range, the Meter wraps to the lowest range. Note You cannot manually change the range in the MIN MAX AVG or Display HOLD modes. If you press qwhile in MIN MAX AVG or Display Hold, the Meter beeps twice, indicating an invalid operation and the range does not change. 3. To exit Manual Range, press q for at least 1 second or turn the rotary switch. The Meter returns to Autorange and Auto is displayed. Power-Up Options To select a Power-Up Option, hold down the button indicated in the following table while turning the Meter on. Power-Up Options are canceled when you turn the Meter off and when sleep mode is activated. Button Power-Up Options f Turns on all display segments. p Disables beeper. bEEP is displayed when enabled. q Enables low impedance capacitance measurements. LCAP is displayed when enabled. See page 14. g Disables automatic power-down ("Sleep mode"). PoFF is displayed when enabled. Q Disables auto backlight off. LoFF is displayed when enabled. Making Basic Measurements The figures on the following pages show how to make basic measurements. When connecting the test leads to the circuit or device, connect the common (COM) test lead before connecting the live lead; when removing the test leads, remove the live lead before removing the common test lead. 9 114, 115, and 117 Users Manual Testing for Continuity Measuring Resistance edy06f.eps edy04f.eps XWWarning To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 Note The continuity function works best as a fast, convenient method to check for opens and shorts. For maximum accuracy in making resistance measurements, use the Meter's resistance (e) function. True-rms Multimeters Making Basic Measurements Measuring AC and DC Voltage Volts AC Volts DC This function also sets the Meter's input impedance to approximately 3 k to reduce the possibility of false readings due to ghost voltages. Measuring AC and DC Millivolts Millivolts AC Millivolts DC V DC edy03f.eps Using Auto Volts Selection (114 & 117 only) With the function switch in the x position, the Meter automatically selects a dc or ac voltage measurement based on the input applied between the V or + and COM jacks. edy18f.eps With the function switch in the l position, the Meter measures ac plus dc millivolts. Press g to switch the Meter to dc millivolts. 11 114, 115, and 117 Users Manual Measuring AC or DC Current (115 & 117) XWWarning To avoid personal injury or damage to the Meter: * * * * Never attempt to make an in-circuit current measurement when the opencircuit potential to earth is >600 V. Check the Meter's fuse before testing. (See "Testing the Fuse") Use the proper terminals, switch position, and range for your measurement. Never place the probes in parallel with a circuit or component when the leads are plugged into the A (Amps) terminals. 1 A 2 3 edy08f.eps Turn circuit power off, break the circuit, insert the Meter in series with the circuit, and then turn circuit power on. 12 True-rms Multimeters Making Basic Measurements Measuring Current above 10 Amps The millivolt and voltage function of the Meter can be used with an optional mV/A output Current Probe to measure currents that exceed the rating of the Meter. Make sure the Meter has the correct function selected, AC or DC, for your current probe. Refer to a Fluke catalog or contact your local Fluke representative for compatible current clamps. Measuring Capacitance (115 & 117 only) edy05f.eps edy14f.eps 13 114, 115, and 117 Users Manual Measuring Frequency (115 & 117 only) XWWarning To avoid electrical shock, disregard the bar graph for frequencies >1 kHz. If the frequency of the measured signal is >1 kHz, the bar graph and Z are unspecified. AC Voltage Frequency AC Current Frequency Press g to turn the frequency measurement function on and off. Frequency works with ac functions only. In frequency, the bar graph and range annunciator indicate the ac voltage or current present. Select progressively lower ranges using manual ranging for a stable reading. Detecting AC Voltage Presence (117 only) VoltAlert Hz Neutral Hot VoltAlert VoltAlert RANGE Lo VoltAlert edy09f.eps The Meter measures the frequency of a signal by counting the number of times the signal crosses a trigger level each second. The trigger level is 0 V, 0 A for all ranges. 14 edy13f.eps True-rms Multimeters Making Basic Measurements To detect the presence of ac voltage, place the top of the Meter close to a conductor. The Meter gives an audible as well as visual indication when voltage is detected. There are two sensitivity settings. The "Lo" setting can be used on flush mounted wall sockets, power strips, flush mounted industrial outlets and various power cords. The "Hi" setting allows for ac voltage detection on other styles of recessed power connectors or sockets where the actual ac voltage is recessed within the connector itself. The VoltAlert detector works in bare wire applications with voltages as low as 24 V in the "Hi" setting. XW Warning If there is no indication, voltage could still be present. Do not rely on the VoltAlert detector with shielded wire. Operation may be effected by differences in socket design, insulation thickness and type. Making Low Impedance Capacitance Measurements (115 & 117 only) For making capacitance measurements on cables with ghost voltage, hold qwhile turning on the Meter to switch the Meter into LoZ, (low input impedance) Capacitance mode. In this mode, capacitance measurements will have a lower accuracy and lower dynamic range. This setting is not saved when the Meter is turned off or goes into sleep mode. Testing Diodes (115 & 117) Good Diode Good Diode Single Beep Forward Bias Bad Diode Open Reverse Bias Bad Diode and Shorted edy07f.eps 15 114, 115, and 117 Users Manual Using the Bargraph The bar graph is like the needle on an analog meter. It has an overload indicator (>) to the right and a polarity indicator (+)to the left. Because the bar graph is much faster than the digital display, the bar graph is useful for making peak and null adjustments. The bar graph is disabled when measuring capacitance. In frequency, the bar graph and range annunciator indicates the underlying voltage or current up to 1 kHz. The number of segments indicates the measured value and is relative to the full-scale value of the selected range. In the 60 V range, for example (see below), the major divisions on the scale represent 0, 15, 30, 45, and 60 V. An input of -30 V turns on the negative sign and the segments up to the middle of the scale. aej11f.eps 16 Testing the Fuse (115 & 117 only) Test fuse as shown below. <.5 OK OK edy10f.eps True-rms Multimeters Maintenance Maintenance Maintenance of the Meter consists of battery and fuse replacement, as well as case cleaning. Replacing the Battery and Fuse XWWarning To avoid shock, injury, or damage to the Meter: * Remove test leads from the Meter before opening the case or battery door. * Use ONLY a fuse with the amperage, interrupt voltage, and speed ratings specified. To remove the battery door for battery replacement: 1. Remove the test leads from the Meter 2. Remove the battery door screw. 3. Use the finger recess to lift the door slightly. 4. Lift the door straight up to separate it from the case. The battery fits inside the battery door, which is then inserted into the case, bottom edge first, until it is fully seated. Do not attempt to install the battery directly into the case. 5. Install and tighten battery door screw. Fuse edy11f.eps 17 114, 115, and 117 Users Manual To open the case for fuse replacement: 1. Remove the test leads from the Meter 2. Remove the Meter from its holster. 3. Remove two screws from the case bottom. 4. Separate the case bottom from the case top. 5. Remove the fuse from its holder and replace it with an 11 A, 1000 V, FAST fuse having a minimum interrupt rating of 17,000 A. Use only Fluke PN 803293. 6. To re-assemble the Meter, first attach the case bottom to the case top, then install the two screws. Finally, insert the Meter into its holster. 18 Cleaning Wipe the case with a damp cloth and mild detergent. Do not use abrasives, isopropyl alcohol, or solvents to clean the case or lens/window. Dirt or moisture in the terminals can affect readings. True-rms Multimeters General Specifications General Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with relative humidity at 0 % to 90 %. Extended specifications are available at www.Fluke.com. Maximum voltage between any terminal and earth ground ...................................... 600 V Surge Protection ..................................................... 6 kV peak per IEC 61010-1 600V CAT III, Pollution Degree 2 W Fuse for A input (115 & 117 only): .................... 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293) Display ..................................................................... Digital: 6,000 counts, updates 4/sec Bar Graph: 33 segments, updates 32/sec Temperature............................................................. Operating: -10 C to + 50 C Storage: -40 C to + 60 C Temperature Coefficient ......................................... 0.1 x (specified accuracy)/C (<18 C or >28 C) Operating Altitude ................................................... 2,000 meters Battery ....................................................................... 9 Volt Alkaline, NEDA 1604A / IEC 6LR61 Battery Life............................................................... Alkaline: 400 hours typical, without backlight Safety Compliances ................................................ Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) nd and IEC/EN 61010-1 2 Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 19 114, 115, and 117 Users Manual Certifications ............................................................UL, P, CSA, TUV, ; (N10140), VDE IP Rating (dust and water protection) ......................... IP42 Table 1. Accuracy Specifications Function Range Resolution Accuracy ([% of Reading] + [Counts]) Model DC millivolts 600.0 mV 0.1 mV 0.5 % + 2 114, 115, 117 DC Volts 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 0.5 % + 2 114, 115, 117 [1] Auto-V LoZ True-rms 600.0 V 0.1 V DC, 45 to 500 Hz 500 Hz to 1 kHz 2.0 % + 3 4.0 % + 3 45 to 500 Hz 500 Hz to 1 kHz [1] AC millivolts True- rms [1] AC Volts True-rms 20 114, 117 600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3 114, 115, 117 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 1.0 % + 3 2.0 % + 3 114, 115, 117 True-rms Multimeters General Specifications Table 1 Accuracy Specifications (cont.) Function Range Resolution Accuracy ([% of Reading] + [Counts]) Beeper on < 20 , off > 250 ; detects opens or shorts of 500 s or longer. Model 114, 115, 117 Continuity 600 1 Ohms 600.0 6.000 k 60.00 k 600.0 k 6.000 M 40.00 M 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M 0.9 % + 2 0.9 % + 1 0.9 % + 1 0.9 % + 1 0.9 % + 1 5%+2 114, 115, 117 Diode test 2.000 V 0.001 V 0.9 % + 2 115, 117 Capacitance 1000 nF 10.00 F 100.0 F 9999 F 1 nF 0.01 F 0.1 F 1 F 1.9 % + 2 1.9 % + 2 1.9 % + 2 100 F - 1000 F: 1.9 % + 2 > 1000 F: 5 % + 20 115, 117 Lo-Z Capacitance (Power-up option) 1 nF to 500 F 10% + 2 typical 115, 117 21 114, 115, and 117 Users Manual Table 1 Accuracy Specifications (cont.) Function Range Resolution 6.000 A AC Amps True10.00 A[3] rms[1] 20 A for 30 seconds max., (45 Hz to 500 Hz) 10 minutes rest min. 0.001 A 0.01 A DC Amps 6.000 A 10.00 A[3] 20 A for 30 seconds max., 10 minutes rest min. 0.001 A 0.01 A Hz (V or A input)[2] 99.99 Hz 999.9 Hz 9.999 kHz 50.00 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz Accuracy ([% of Reading] + [Counts]) Model 1.5 % + 3 115, 117 1.0 % + 3 115, 117 0.1 % + 2 115, 117 Notes: [1] All ac ranges except Auto-V LoZ are specified from 1 % to 100 % of range. Auto-V LoZ is specified from 0.0 V. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display nonzero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. For amps, crest factor of 3. AC volts is ac-coupled. AutoV LoZ, AC mV, and AC amps are dc-coupled. [2] AC Volts Hz is ac-coupled and specified from 5 Hz to 50 kHz. AC Amps Hz is dc-coupled and specified from 45 Hz to 5 kHz. [3] >10 A unspecified. 22 True-rms Multimeters General Specifications Table 2. Input Characteristics Function Volts AC Volts DC Auto-V LoZ Ohms Diode Test Input Impedance (Nominal) Common Mode Rejection Ratio (1 k Unbalanced) >5 M <100 pF >60 dB at dc, 50 or 60 Hz >10 M <100 pF >100 dB at dc, 50 or 60 Hz ~3 k <500 pF >60 dB at dc, 50 or 60 Hz Open Circuit Test Voltage Full Scale Voltage <2.7 V dc <2.7 V dc To 6.0 M 40 M <0.7 V dc <0.9 V dc 2.000 V dc Normal Mode Rejection >60 dB at 50 or 60 Hz Short Circuit Current <350 A <1.2 mA 23 114, 115, and 117 Users Manual 24