Signal Transformer Standard and Custom Power Transformers The Signal Way of Doing Business... (Often imitated, but NEVER equalled) At Signal Transformer, we are committed to providing the highest grade magnetics for customers who demand total reliability, on-time delivery and competitive pricing. Year after year, independent brand preference studies conducted by leading electronic trade journals, have shown that engineers and buyers consistently vote Signal as the No. 1 preferred source for magnetics. For almost 40 years, we've led the magnetics industry with innovation, creativity, and reliability by: Design and Construction Without Equal Because we pride ourselves in listening to what our customers say, we at Signal have always been able to develop innovative, quality products that meet changing requirements. Our success is built on continuously Independent and isolated primary & secondary addressing all windings current major concerns i.e. flammability, high temperature materials, and design High criteria such as: performance Full insulating lamination * Smaller size shroud and weight Typical example cross section: Model A41 (For example, see our MPI, HPI & M4L Series) * Pioneering and perfecting direct sales of off-the-shelf transformers and chokes to the user. * Maintaining the largest inventories--over 1,000 different chokes and transformers in ranges from 1 VA to 10 KVA, available off-the-shelf for PRONTO shipment. * Offering customized J.I.T. programs. * Providing annual contract programs with the most competitive volume pricing. * Better performance through improved volumetric efficiency (For example, see our M4L series) * Obtaining the latest safety agency certifications including UL, CSA, VDE, IEC, EN * Higher isolation while eliminating crossovers of primary and secondary leads (For example, see our 14A series) Delivery Speed Without Equal * Superior suppression of radiated magnetic field (For example, see our IF series) PRONTOSM (24-Hour Shipment) Our PRONTO shipment program is simple. We ship off-the-shelf products within 24 Hours, and, in most cases the same day! We are able to make this commitment because we match computerized inventory production schedules with SM industry requirements. Larger production orders are comfortably scheduled to meet J.I.T. or any delivery scheduling. In fact, each year over 20,000 orders are shipped to satisfied customers, on-time, every time. Technical Support Without Equal With one of the industries largest staff of application engineers, supported by the latest CAD/CAM equipment, our engineering team responds quickly to your specific application needs, custom requirements, and your quotation requests. Please don't hesitate to call, write, or fax us direct. (c) Copyright 1994 by Signal Transformer Co., Inc., Inwood, NY. All International Rights Reserved. All specifications subject to change without notice. Consult factory for latest specifications. Printed in U.S.A.--Catalog ST-5 2 Quality Assurance Without Equal Custom Design Without Equal Through years of extensive magnetics manufacturing experience, Signal has developed a unique, world-class Total Quality Program. This program embodies the latest state-of-the-art manufacturing processes and monitoring systems from first article inspection through 100% electrical testing for key performance and safety parameters. At Signal, we've designed thousands of custom products, and may have already solved your problem. If not, we will! To make it easy to identify your specific requirements, we've included a Custom Magnetics Design Data Sheet in our catalog. Our design engineering team welcomes the opportunity to be of service. Terms and Conditions: Freight Policy Orders are shipped FOB (point of origin). All UPS shipments are prepaid and freight charges will be added to your invoice. All other carriers are shipped freight collect unless we are otherwise instructed. How to Order Simply call 516-239-5777 and ask to speak to one of our customer service representatives waiting to answer your inquiry. If you wish you may fax your order to our 24-hour fax line (516-239-7208) or mail your purchase order to 500 Bayview Avenue, Inwood, New York, 11096. If faxing or mailing your order please be certain to include your phone number so you can be reached if there are any questions concerning your order. Damaged Shipment Transformers shipped are carefully packed in compliance with carrier requirements. Claims for loss or damage in transit must be made with the carrier by the customer within 15 days of delivery. All shipments should be unpacked and inspected immediately upon receipt. If damage does not become apparent until shipment is unpacked, make a request within 72 hours for inspection by the carrier's agent and file with the carrier. Any evidence of damage to packaging must be noted on the freight bill or carrier's receipt and signed by the carrier's agent. Failure to do this will result in the carrier refusing to honor the claim. Terms of Sale Net 30 days to firms with acceptable D&B rating. Unrated firms, please submit name of your bank and 3 major trade references. Other methods are: C.O.D. for any of our stock transformers, cash in advance for non-stock or custom transformers. We also accept MasterCard and Visa which saves the additional C.O.D. charges. Return Policy You will find that the quality products purchased from Signal Transformer have been manufactured to give you the high level of quality you expect. Our goal has always been to make sure you are completely satisfied every time you do business with us. If a qualified reason exists, a Return Material Authorization will be given to you promptly and a replacement order will be processed immediately at the time of your call. Prices Prices are published on our price sheet and are subject to change without notice. Extra Charges All non-stock and custom transformer orders are subject to a set-up charge. Warranty Signal products are warranted to be free of defects in materials and workmanship when operated within specified operating conditions. Contact Signal for specific warrantee, terms and conditions. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 3 Selector Chart This selector chart was created to assist you in finding the corresponding page for the transformer needed for your application. How to use: * Select type of unit required, i.e. printed circuit, chassis mount, etc. * Select power range (more than one family may be available). * Select voltage range (AC or DC voltage). * Select agency approvals necessary, i.e., UL, CSA, VDE, UL1585, Class 2. * Identify family and turn to corresponding page number. Printed Circuit Mount Power Range (VA) Secondary Voltage Range Agency Approvals Family Page # 2.5-10 5V-36 VCT UL, CSA, VDE 14A-R 12 20-56 5V-36VCT UL, CSA, VDE 14A 13 20-56 5VDC & 12VDC or 15VDC UL, CSA, VDE 14A Triple Output 14 2-30 5V-230VCT UL, CSA, VDE IF 10-11 2-48 5V-230VCT UL, CSA LP 15 6-12 5VDC & 12VDC or 15VDC UL, CSA MPL Triple Output 19 1.1-36 5V-120VCT UL, CSA ST/DST 16 1.0-24 5V-120VCT UL, CSA PC/DPC 17 10-24 5VDC & 12VDC or 15VDC UL, CSA MPC/DMPC Triple Output 18 2.5-50 12V-24V UL 1585, Class 2 CL2 20 Power Range (VA) Secondary Voltage Range Agency Approvals Family Page # 250-900 5V-230VCT UL, CSA MPI 7 2000-3500 115V-230V UL, CSA, VDE HPI 5 300-1000 115V UL, CSA, VDE M4L 6 25-175 5V-230VCT UL, CSA, VDE A41 8 25-80 5VDC & 12VDC or 15VDC UL, CSA, VDE A41 Triple Output 9 2.4-100 10Vct-120Vct UL, CSA 241/DP241 22 Chassis Mount 30-100 5VDC & 12VDC or 15VDC UL, CSA MT/DMT Triple Output 23 25-80 12V-24V UL 1585, Class 2 CL2 21 Family Page # Supplemental Magnetics Power Range (VA) Secondary Voltage Range 10-2000 5VCT-80VCT Rectifier Power 24-26 250-10,000 104V-240V Power Isolation 28-29 100-2000 115V-230V Auto Transformers 30 Inductance Current Family Page # .12-1000mH 1.0-200AMPS Chokes 27 Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 4 High Power International Transformers SM Greater Performance in Less Space and Weight RUGGED TERMINAL BLOCK RUGGED MOUNTING BRACKETS UNIQUE BOBBIN COIL CONSTRUCTION CV Part No. VA (Size) HPI-20 f Signal's HPI transformers feature unique coil construction that complies with international safety standards and results in a smaller and lighter transformer. General Specifications Power - 2000 VA to 3500 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual/tapped primaries (100V, 115V, 215V, 230V - 50/60 Hz) Secondaries - Series or parallel secondaries (115V or 230V) Electrostatic Shield - 5 mils thick copper foil Terminals - Screw type barrier strip Leakage - Leakage current meets medical applications Insulation - Class H insulation (180C) Flammability Rating - Bobbin material meets UL 94V0 Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) VDE certified to VDE 0550 (File #2994) TUV certified to IEC 950 (Lic #R9373110.2) Secondary RMS Rating Mechanical Dimensions Series Parallel 2000 230V @ 8.7A 115V @ 17.4A HPI-27 2750 230V @ 12.0A 115V @ 24.0A HPI-35 3500 230V @ 15.2A 115V @ 30.4A L 7.50 190.5mm 7.50 190.5mm 7.50 190.5mm W 5.60 142.2mm 6.23 158.2mm 7.33 186.2mm H 6.56 166.6mm 6.56 166.6mm 6.56 166.6mm A 6.25 158.8mm 6.25 158.8mm 6.25 158.8mm ML 5.75 146.1mm 5.75 146.1mm 5.75 146.1mm MW 4.35 110.5mm 4.98 126.5mm 6.08 154.4mm Wgt 41.3 lbs 18.71 kg 48.0 lbs 21.77 kg 62.4 lbs 28.30 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 5 More-4-LessTM International Transformers SM Greater Performance in Less Space Signal's M4L transformer series is designed using low loss steel, high temperature magnet wire plus high temperature bobbins and shroud. These unique design features result in a smaller and lighter transformer for comparable power sizes. Shrouded Terminal Block (Meets all standards) Insulating Shroud General Specifications Power - 300 VA to 1000 VA Dielectric Strength - 4000VRMS Hipot Primaries - Style M4L-1 (105V, 115V, 125V - 50/60 Hz) Style M4L-2 (210V, 230V, 250V - 50/60 Hz) Style M4L-3 (100V, 115V, 200V, 230V - 50/60 Hz) Secondary - Single secondary (115V) Terminals - Quick-connect / screw type terminals Leakage - Leakage current to meet UL 544 Insulation - Class F insulation (155C) Flammability Rating - Bobbin and shroud material meet UL 94V0 "Quickconnect" Terminal Screw Connection Agency Standards UL recognized to UL 506 (File #E63829) UL recognized to UL 544 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) VDE certified to VDE 0805 / EN 60950 (File #1447) VDE certified to IEC 950 Dual Bobbins CV Part Number f Mtg. Dim. VA (Size) Secondary RMS Rating L W H A B C M4L-3-3 300 115V @ 2.6A 3.50 88.9mm 3.87 98.4mm 3.75 95.3mm 1.12 28.6mm .62 15.9mm M4L-2-6 M4L-3-6 600 115V @ 5.2A 3.87 98.4mm 4.93 4.50 125.4mm 114.3mm 1.18 30.2mm M4L-2-10 M4L-3-10 1000 115V @ 8.7A 5.37 5.87 5.25 136.5mm 149.2mm 133.4mm 1.50 38.1mm 115V Nominal 230V Nominal 100-115/200-230V Nominal M4L-1-3 M4L-2-3 M4L-1-6 M4L-1-10 Mtg. Screw Wgt 3.12 79.4mm #10 7.0 lbs 3.18 kg 3.00 76.2mm 4.06 103.2mm #10 14.3 lbs 6.49 kg 4.37 3.50 111.1mm 88.9mm 4.06 119.1mm 1/4 22.0 lbs 10.0 kg ML MW 3.12 79.4mm 2.50 63.5mm .75 19.1mm 3.75 95.3mm .87 22.2mm If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 6 Multi-Purpose International Transformers SM High Performance with Greater Volumetric Efficiency Quick Connect Screw Type Terminal Unique Coil Construction CV Signal's MPI transformers feature higher volumetric efficiency for improved performance compared to conventional 50/60 Hz transformers. They also incorporate international safety features which make them ideal for worldwide applications. General Specifications Power - 200 VA to 900 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual/tapped primaries (100V, 115V, 200V, 215V, 230V - 50/60 Hz) Secondaries - Series or parallel secondaries Electrostatic Shield - 5 mils thick copper foil Terminals - Quick-connect/screw type terminals Leakage - Leakage current meets medical applications Insulation - Class F insulation (155C) Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) Designed to meet VDE 0805 and VDE 0550 Designed to meet IEC 950 SECONDARY SECONDARY Part No. Series Parallel Part No. Series Parallel MPI-200-10 MPI-250-10 MPI-300-10 MPI-400-10 MPI-650-10 MPI-900-10 MPI-200-12 MPI-250-12 MPI-300-12 MPI-400-12 MPI-650-12 MPI-900-12 MPI-200-16 MPI-250-16 MPI-300-16 MPI-400-16 MPI-650-16 MPI-900-16 MPI-200-20 MPI-250-20 MPI-300-20 MPI-400-20 MPI-650-20 MPI-900-20 MPI-200-24 MPI-250-24 MPI-300-24 MPI-400-24 MPI-650-24 MPI-900-24 10VCT @ 20.0A 10VCT @ 25.0A 10VCT @ 30.0A 10VCT @ 40.0A 10VCT @ 65.0A 10VCT @ 90.0A 12VCT @ 16.7A 12VCT @ 20.8A 12VCT @ 25.0A 12VCT @ 33.3A 12VCT @ 54.2A 12VCT @ 75.0A 16VCT @ 12.5A 16VCT @ 15.6A 16VCT @ 18.8A 16VCT @ 25.0A 16VCT @ 40.6A 16VCT @ 56.3A 20VCT @ 10.0A 20VCT @ 12.5A 20VCT @ 15.0A 20VCT @ 20.0A 20VCT @ 32.5A 20VCT @ 45.0A 24VCT @ 8.3A 24VCT @ 10.4A 24VCT @ 12.5A 24VCT @ 16.7A 24VCT @ 27.1A 24VCT @ 37.5A 5V @ 40.0A 5V @ 50.0A 5V @ 60.0A 5V @ 80.0A 5V @ 130.0A 5V @ 180.0A 6V @ 33.3A 6V @ 41.7A 6V @ 50.0A 6V @ 66.6A 6V @ 108.4A 6V @ 150.0A 8V @ 25.0A 8V @ 31.2A 8V @ 37.6A 8V @ 50.0A 8V @ 81.2A 8V @ 112.5A 10V @ 20.0A 10V @ 25.0A 10V @ 30.0A 10V @ 40.0A 10V @ 65.0A 10V @ 90.0A 12V @ 16.7A 12V @ 20.8A 12V @ 25.0A 12V @ 33.3A 12V @ 54.2A 12V @ 75.0A MPI-200-28 MPI-250-28 MPI-300-28 MPI-400-28 MPI-650-28 MPI-900-28 MPI-200-36 MPI-250-36 MPI-300-36 MPI-400-36 MPI-650-36 MPI-900-36 MPI-200-40 MPI-250-40 MPI-300-40 MPI-400-40 MPI-650-40 MPI-900-40 MPI-200-48 MPI-250-48 MPI-300-48 MPI-400-48 MPI-650-48 MPI-900-48 MPI-200-230 MPI-250-230 MPI-300-230 MPI-400-230 MPI-650-230 MPI-900-230 28VCT @ 7.1A 28VCT @ 8.9A 28VCT @ 10.7A 28VCT @ 14.3A 28VCT @ 23.2A 28VCT @ 32.1A 36VCT @ 5.6A 36VCT @ 6.9A 36VCT @ 8.3A 36VCT @ 11.1A 36VCT @ 18.1A 36VCT @ 25.0A 40VCT @ 5.0A 40VCT @ 6.3A 40VCT @ 7.5A 40VCT @ 10.0A 40VCT @ 16.3A 40VCT @ 22.5A 48VCT @ 4.2A 48VCT @ 5.2A 48VCT @ 6.3A 48VCT @ 8.3A 48VCT @ 13.5A 48VCT @ 18.8A 230VCT @ 0.87A 230VCT @ 1.1A 230VCT @ 1.3A 230VCT @ 1.7A 230VCT @ 2.8A 230VCT @ 3.9A 14V @ 14.2A 14V @ 17.9A 14V @ 21.4A 14V @ 28.6A 14V @ 46.4A 14V @ 64.2A 18V @ 11.2A 18V @ 13.8A 18V @ 16.7A 18V @ 22.2A 18V @ 36.2A 18V @ 50.0A 20V @ 10.0A 20V @ 12.6A 20V @ 15.0A 20V @ 20.0A 20V @ 32.6A 20V @ 45.0A 24V @ 8.3A 24V @ 10.4A 24V @ 12.6A 24V @ 16.7A 24V @ 27.1A 24V @ 37.5A 115V @ 1.7A 115V @ 2.2A 115V @ 2.6A 115V @ 3.4A 115V @ 5.6A 115V @ 7.8A VA (Size) L W H ML MW WGT 200 3.750 95.3mm 4.203 106.6mm 3.720 94.5mm 3.250 82.6mm 2.800 71.1mm 6.22 lbs 2.82 kg 250 4.125 104.8mm 3.898 99.0mm 4.000 101.6mm 3.625 92.1mm 2.601 66.1mm 6.76 lbs 3.07 kg 300 4.125 104.8mm 4.223 107.3mm 4.000 101.6mm 3.625 92.1mm 2.915 74.0mm 7.80 lbs 3.54 kg 400 4.125 104.8mm 4.805 122.0mm 4.000 101.6mm 3.625 92.1mm 3.505 89.0mm 9.82 lbs 4.46 kg 650 5.250 133.3mm 4.430 112.5mm 4.800 121.9mm 4.500 114.3mm 3.415 86.7mm 14.83 lbs 6.73 kg 900 5.250 133.3mm 5.197 132.0mm 4.800 121.9mm 4.500 114.3mm 4.205 106.8mm 19.84 lbs 9.01 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 7 All-4-OneTM International Transformers Chassis Mount SM International Standards at Lower Cost and Better Performance CV Signal's A41 transformers provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications Power - 25 VA to 175 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual primaries (115/230 V - 50/60 Hz) Secondaries - Series or parallel secondaries Electrostatic Shield - Not necessary, dual bobbin construction Terminals - Solder lug / quick-connect type terminals Leakage - Leakage current to meet UL 544 Insulation - Class F insulation (155C) Flammability Rating - Bobbin and shroud material meet UL 94V0 Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) VDE certified to VDE 0805 / EN 60950 (File #1448) VDE certified to IEC 950 f Part No. A41-25-10 A41-43-10 A41-80-10 A41-130-10 A41-175-10 A41-25-12 A41-43-12 A41-80-12 A41-130-12 A41-175-12 A41-25-16 A41-43-16 A41-80-16 A41-130-16 A41-175-16 A41-25-20 A41-43-20 A41-80-20 A41-130-20 A41-175-20 A41-25-24 A41-43-24 A41-80-24 A41-130-24 A41-175-24 A41-25-28 A41-43-28 A41-80-28 A41-130-28 A41-175-28 A41-25-36 A41-43-36 A41-80-36 A41-130-36 A41-175-36 A41-25-230 A41-43-230 A41-80-230 A41-130-230 A41-175-230 Dimensions VA (Size) 25 43 80 130 175 L 2.81 71.4mm 3.12 79.4mm 2.50 63.5mm 2.81 71.4mm 3.12 79.4mm W 1.87 47.6mm 2.06 52.3mm 2.37 60.3mm 2.87 73.0mm 2.87 73.0mm H 2.31 58.7mm 2.68 68.2mm 3.00 76.2mm 3.37 85.7mm 3.75 95.3mm A 2.00 50.8mm 2.25 57.2mm - - - - - - B 1.12 28.6mm 1.12 28.6mm 1.37 35.0mm 1.62 41.3mm 1.62 41.3mm C .31 7.9mm .31 7.9mm .31 7.9mm .37 9.5mm .37 9.5mm Terminals .187 4.75mm .187 4.75mm .187 4.75mm 0.25 6.35mm 0.25 6.35mm Mtg. Style C C B B B VA (Size) 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 Secondary RMS Rating Series Parallel 10VCT @ 2.5A 5V @ 5.0A 10VCT @ 4.3A 5V @ 8.6A 10VCT @ 8.0A 5V @ 16.0A 10VCT @ 13.0A 5V @ 26.0A 10VCT @ 17.5A 5V @ 35.0A 12.6VCT @ 2.0A 6.3V @ 4.0A 12.6VCT @ 3.4A 6.3V @ 6.8A 12.6VCT @ 6.3A 6.3V @ 12.6A 12.6VCT @ 10.3A 6.3V @ 20.6A 12.6VCT @ 14.0A 6.3V @ 28.0A 16VCT @ 1.6A 8V @ 3.2A 16VCT @ 2.7A 8V @ 5.4A 16VCT @ 5.0A 8V @ 10.0A 16VCT @ 8.1A 8V @ 16.2A 16VCT @ 11.0A 8V @ 22.0A 20VCT @ 1.25A 10V @ 2.5A 20VCT @ 2.2A 10V @ 4.4A 20VCT @ 4.0A 10V @ 8.0A 20VCT @ 6.5A 10V @ 13.0A 20VCT @ 8.8A 10V @ 17.6A 24VCT @ 1.0A 12V @ 2.0A 24VCT @ 1.8A 12V @ 3.6A 24VCT @ 3.3A 12V @ 6.6A 24VCT @ 5.4A 12V @ 10.8A 24VCT @ 7.3A 12V @ 14.6A 28VCT @ 0.9A 14V @ 1.86A 28VCT @ 1.5A 14V @ 3.0A 28VCT @ 2.8A 14V @ 5.6A 28VCT @ 4.6A 14V @ 9.2A 28VCT @ 6.25A 14V @ 12.5A 36VCT @ 0.7A 18V @ 1.4A 36VCT @ 1.2A 18V @ 2.4A 36VCT @ 2.2A 18V @ 4.4A 36VCT @ 3.6A 18V @ 7.2A 36VCT @ 4.8A 18V @ 9.6A 230VCT @ 0.11A 115V @ 0.22A 230VCT @ 0.19A 115V @ 0.38A 230VCT @ 0.35A 115V @ 0.7A 230VCT @ 0.57A 115V @ 1.14A 230VCT @ 0.76A 115V @ 1.52A Mtg. Dim. ML MW 2.37 - 60.3mm - 2.81 - 71.4mm - 2.00 2.18 50.8mm 55.5mm 2.25 2.50 57.2mm 63.5mm 2.50 2.50 63.5mm 63.5mm Mtg. Screw #6 #6 #6 #8 #8 Wgt 1.25 lbs 0.57 kg 1.6 lbs 0.73 kg 2.8 lbs 1.27 kg 4.1 lbs 1.86 kg 5.5 lbs 2.49 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 8 All-4-OneTM International Triple Output Transformers * Chassis Mount SM For 5 VDC and 12 VDC or 15 VDC Regulated Power Supplies Which Require International Safety Certification CV Part Number VA (Size) f Signal's A41 triple output transformers have chassis mount capability plus all of the performance features of our split bobbin A41 series. General Specifications Power -- 25 VA to 80 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual primaries (115/230 V - 50/60 Hz) Input range (100V to 130V or 200V to 260V - 50/60 Hz) Secondaries - Dual complimentary outputs (5 VDC with 12 VDC or 5 VDC with 15 VDC) Electrostatic Shield - Not necessary, split bobbin construction Terminals - Solder lug/quick-connect type terminals Insulation - Class F insulation (155C) Flammability Rating - Bobbin and shroud material meet UL 94V0 Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) VDE certified to VDE 0805 / EN 60950 (File #4362) VDE certified to IEC 950 DC Output C2 C4 See Note Suggested Components Regulator I Regulator II C1 C3 IC1 IC2 IC3 D1 D2 A41-25-512 25 5V @ 1.25A 12V @ 150mA 4.1 KMFD 600 MFD LM-323K-5 LM-340K-12 LM-320K-12 PE20 PF20 A41-25-515 25 5V @ 1.25A 15V @ 130mA 15 VDC 50 VDC LM-323K-5 LM-340K-15 LM-320K-15 PE20 PF20 A41-43-512 43 5V @ 2A 12V @ 300mA 8 KMFD 1.1 KMFD LM-323K-5 LM-340K-12 LM-320K-12 PE20 PF20 A41-43-515 43 5V @ 2A 15V @ 250mA 15 VDC 50 VDC LM-323K-5 LM-340K-15 LM-320K-15 PE20 PF20 @ @ @ @ A41-80-512 80 5V @ 3.5A 12V @ 600mA 10 KMFD 2.1 KMFD LM-338 LM-340K-12 LM-320K-12 PP20 PF20 A41-80-515 80 5V @ 3.5A 15V @ 500mA 15 VDC 50 VDC LM-338 LM-340K-15 LM-320K-15 PP20 PF20 Note : Note : Note : Note : 43 80 @ Output capacitors C2 and C4 are required to stabilize regulators. Values can be 1MFD min. tantalum or 10MFD min. electrolytic, 20V min. LM-338 is an adjustable regulator and MFR's specifications (National Semiconductor) should be consulted for values of external components. All IC's are National Semiconductor types. All bridges are EDI types VA (Size) 25 @ L 2.81 71.4mm 3.12 79.4mm 2.50 63.5mm Dimensions W H 1.87 2.31 47.6mm 58.7mm 2.06 2.68 52.3mm 68.2mm 2.37 3.00 60.3mm 76.2mm A 2.00 50.8mm 2.25 57.2mm - - B 1.12 28.6mm 1.12 28.6mm 1.37 34.9mm Terminal C 0.31 7.9mm 0.31 7.9mm 0.31 7.9mm 0.187 4.75mm 0.187 4.75mm 0.187 4.75mm Mtg. Style C C B Mtg. Dim. ML 2.37 60.3mm 2.81 71.4mm 2.00 50.8mm MW - - - - 2.18 55.5mm Mtg. Screw Wgt #6 1.25 lbs 0.57 kg 1.6 lbs 0.73 kg 2.8 lbs 1.27 kg #6 #6 If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 9 International FlatheadTM Low Profile Transformers * Printed Circuit Mount SM For Critical Height and International Safety Requirements CV f Signal's IF transformers utilize unique insulating techniques, including full encapsulation to meet international safety requirements. These transformers are ideal for low power applications where minimum height is required. General Specifications Power - 2 VA to 30 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual primaries (115/230 V - 50/60 Hz) Secondaries - Series of parallel secondaries Electrostatic Shield - Not necessary, split bobbin construction Magnetic Field - Reduced magnetic radiation Height - .69 to 1.39 inches (17.5 to 35.3mm) high Insulation - Class B insulation (130C) Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) VDE certified to VDE 0805 / EN 60950 (File #8325) VDE certified to IEC 950 VA (Size) 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 Part No. IF-2-10 IF-2-12 IF-2-16 IF-2-20 IF-2-24 IF-2-30 IF-2-34 IF-2-40 IF-2-56 IF-2-230 IF-4-10 IF-4-12 IF-4-16 IF-4-20 IF-4-24 IF-4-30 IF-4-34 IF-4-40 IF-4-56 IF-4-230 IF-6-10 IF-6-12 IF-6-16 IF-6-20 IF-6-24 IF-6-30 IF-6-34 IF-6-40 IF-6-56 IF-6-230 VA (Size) 2 4 6 L 2.09 53.0mm 2.09 53.0mm 2.09 53.0mm Secondary RMS Rating Series Parallel 10VCT @ 200mA 5V @ 400mA 12VCT @ 170mA 6V @ 340mA 16VCT @ 125mA 8V @ 250mA 20VCT @ 100mA 10V @ 200mA 24VCT @ 85mA 12V @ 170mA 30VCT @ 70mA 15V @ 140mA 34VCT @ 60mA 17V @ 120mA 40VCT @ 50mA 20V @ 100mA 56VCT @ 40mA 28V @ 80mA 230VCT @ 9 mA 115V @ 18mA 10VCT @ 400 mA 5V @ 800mA 12VCT @ 335mA 6V @ 670mA 16VCT @ 250mA 8V @ 500mA 20VCT @ 200mA 10V @ 400mA 24VCT @ 170mA 12V @ 340mA 30VCT @ 135mA 15V @ 270mA 34VCT @ 120mA 17V @ 240mA 40VCT @ 100mA 20V @ 200mA 56VCT @ 70mA 28V @ 140mA 230VCT @ 18mA 115V @ 36mA 10VCT @ 600mA 5V @ 1.20A 12VCT @ 500mA 6V @ 1.00A 16VCT @ 375mA 8V @ 750mA 20VCT @ 300mA 10V @ 600mA 24VCT @ 250mA 12V @ 500mA 30VCT @ 200mA 15V @ 400mA 34VCT @ 180mA 17V @ 360mA 40VCT @ 150mA 20V @ 300mA 56VCT @ 110mA 28V @ 220mA 230VCT @ 25mA 115V @ 50mA W 1.73 44.0mm 1.73 44.0mm 1.73 44.0mm H 0.69 17.6mm 0.77 19.6mm 0.89 22.6mm ML 1.87 47.5mm 1.87 47.5mm 1.87 47.5mm MW 1.48 37.5mm 1.48 37.5mm 1.48 37.5mm Wgt 4.6 oz 0.13 kg 5.4 oz 0.15 kg 6.9 oz. 0.20 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 10 International FlatheadTM Low Profile Transformers * Printed Circuit Mount SM For Critical Height and International Safety Requirements (continued) Part No. IF-10-10 IF-10-12 IF-10-16 IF-10-20 IF-10-24 IF-10-30 IF-10-34 IF-10-40 IF-10-56 IF-10-230 IF-14-10 IF-14-12 IF-14-16 IF-14-20 IF-14-24 IF-14-30 IF-14-34 IF-14-40 IF-14-56 IF-14-230 IF-18-10 IF-18-12 IF-18-16 IF-18-20 IF-18-24 IF-18-30 IF-18-34 IF-18-40 IF-18-56 IF-18-230 IF-24-10 IF-24-12 IF-24-16 IF-24-20 IF-24-24 IF-24-30 IF-24-34 IF-24-40 IF-24-56 IF-24-230 IF-30-10 IF-30-12 IF-30-16 IF-30-20 IF-30-24 IF-30-30 IF-30-34 IF-30-40 IF-30-56 IF-30-230 VA (Size) 10 14 18 24 30 L 2.66 67.6mm 2.66 67.6mm 2.66 67.6mm 2.68 68.0mm 2.68 68.0mm W 2.24 57.0mm 2.24 57.0mm 2.24 57.0mm 2.26 57.5mm 2.26 57.5mm H 0.89 22.6mm 0.96 24.3mm 1.09 27.6mm 1.23 31.3mm 1.39 35.3mm ML 2.46 62.5mm 2.46 62.5mm 2.46 62.5mm 2.46 62.5mm 2.46 62.5mm VA (Size) 10 10 10 10 10 10 10 10 10 10 14 14 14 14 14 14 14 14 14 14 18 18 18 18 18 18 18 18 18 18 24 24 24 24 24 24 24 24 24 24 30 30 30 30 30 30 30 30 30 30 MW 1.97 50.0mm 1.97 50.0mm 1.97 50.0mm 1.97 50.0mm 1.97 50.0mm Secondary RMS Rating Series Parallel 10VCT @ 1.00A 5V @ 2.00A 12VCT @ 835mA 6V @ 1.67A 16VCT @ 625mA 8V @ 1.25A 20VCT @ 500mA 10V @ 1.00A 24VCT @ 420mA 12V @ 840mA 30VCT @ 335mA 15V @ 670mA 34VCT @ 300mA 17V @ 600mA 40VCT @ 250mA 20V @ 500mA 56VCT @ 180mA 28V @ 360mA 230VCT @ 45mA 115V @ 90mA 10VCT @ 1.40A 5V @ 2.80A 12VCT @ 1.20A 6V @ 2.40A 16VCT @ 875mA 8V @ 1.75A 20VCT @ 700mA 10V @ 1.40A 24VCT @ 600mA 12V @ 1.20A 30VCT @ 470mA 15V @ 940mA 34VCT @ 415mA 17V @ 830mA 40VCT @ 350mA 20V @ 700mA 56VCT @ 250mA 28V @ 500mA 230VCT @ 60mA 115V @ 120mA 10VCT @ 1.80A 5V @ 3.60A 12VCT @ 1.50A 6V @ 3.00A 16VCT @ 1.15A 8V @ 2.30A 20VCT @ 900mA 10V @ 1.80A 24VCT @ 750mA 12V @ 1.50A 30VCT @ 600mA 15V @ 1.20A 34VCT @ 530mA 17V @ 1.06A 40VCT @ 450mA 20V @ 900mA 56VCT @ 320mA 28V @ 640mA 230VCT @ 80mA 115V @ 160mA 10VCT @ 2.40A 5V @ 4.80A 12VCT @ 2.00A 6V @ 4.00A 16VCT @ 1.50A 8V @ 3.00A 20VCT @ 1.20A 10V @ 2.40A 24VCT @ 1.00A 12V @ 2.00A 30VCT @ 800mA 15V @ 1.60A 34VCT @ 700mA 17V @ 1.40A 40VCT @ 600mA 20V @ 1.20A 56VCT @ 430mA 28V @ 860mA 230VCT @ 105mA 115V @ 210mA 10VCT @ 3.00A 5V @ 6.00A 12VCT @ 2.50A 6V @ 5.00A 16VCT @ 1.90A 8V @ 3.80A 20VCT @ 1.50A 10V @ 3.00A 24VCT @ 1.25A 12V @ 2.50A 30VCT @ 1.00A 15V @ 2.00A 34VCT @ 900mA 17V @ 1.80A 40VCT @ 750mA 20V @ 1.50A 56VCT @ 550mA 28V@ 1.10A 230VCT @ 130mA 115V @ 260mA A 0.42 10.6mm 0.42 10.6mm 0.42 10.6mm 0.43 10.9mm 0.43 10.9mm B 0.45 11.3mm 0.45 11.3mm 0.45 11.3mm 0.46 11.5mm 0.46 11.5mm Wgt 10.3 oz 0.29 kg 11.9 oz 0.34 kg 14.1 oz 0.40 kg 16.5 oz 0.47 kg 19.7 oz 0.58 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 11 One-4-AllTM International Transformers Printed Circuit Mount SM International Standards at Lower Cost and Better Performance CV Signal's 14A transformers are used in low power applications and provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications Power - 2.5 VA to 10 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual primaries (115/230V - 50/60 Hz) Secondaries - Series or parallel secondaries Electrostatic Shield - Not necessary, split or dual bobbin construction Insulation - Class F insulation (155C) Flammability - Bobbin and wrap around shroud material meet UL 94V0 Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) VDE certified to VDE 0805 / EN 60950 (File #1446) VDE certified to IEC 950 f Dimensions L W H A 1.62 1.43* 1.12 0.200 2.5 41.3mm 36.5mm 28.6mm 5.08mm 1.62 1.43 1.37 0.200 5.0 41.3mm 36.5mm 34.9mm 5.08mm 1.87 1.56 1.37 0.200 10.0 47.6mm 39.7mm 34.9mm 5.08mm *NOTE: Previously this dimension was 1.31; now it is 1.43. VA (Size) B 0.250 6.35mm 0.400 10.16mm 0.400 10.16mm Secondary RMS Rating Series Parallel VA Part No. (Size) 14A-2.5R-10 14A-5.0R-10 14A-10R-10 2.5 5.0 10.0 10VCT @ 0.25A 10VCT @ 0.50A 10VCT @ 1.00A 5V @ 0.50A 5V @ 1.00A 5V @ 2.00A 14A-2.5R-12 14A-5.0R-12 14A-10R-12 2.5 5.0 10.0 12.6VCT @ 0.20A 12.6VCT @ 0.40A 12.6VCT @ 0.80A 6.3V @ 0.40A 6.3V @ 0.80A 6.3V @ 1.60A 14A-2.5R-16 14A-5.0R-16 14A-10R-16 2.5 5.0 10.0 16VCT @ 0.15A 16VCT @ 0.31A 16VCT @ 0.62A 8V @ 0.30A 8V @ 0.62A 8V @ 1.25A 14A-2.5R-20 14A-5.0R-20 14A-10R-20 2.5 5.0 10.0 20VCT @ 0.12A 20VCT @ 0.25A 20VCT @ 0.50A 10V @ 0.24A 10V @ 0.50A 10V @ 1.00A 14A-2.5R-24 14A-5.0R-24 14A-10R-24 2.5 5.0 10.0 24VCT @ 0.10A 24VCT @ 0.21A 24VCT @ 0.42A 12V @ 0.20A 12V @ 0.42A 12V @ 0.84A 14A-2.5R-28 14A-5.0R-28 14A-10R-28 2.5 5.0 10.0 28VCT @ 0.09A 28VCT @ 0.18A 28VCT @ 0.36A 14V @ 0.18A 14V @ 0.36A 14V @ 0.72A 14A-2.5R-36 14A-5.0R-36 14A-10R-36 2.5 5.0 10.0 36VCT @ 0.07A 36VCT @ 0.14A 36VCT @ 0.28A 18V @ 0.14A 18V @ 0.28A 18V @ 0.56A C 1.000 25.4mm 1.000 25.4mm 1.140 29.0mm Sq. Pin Dimensions 0.025" 0.635mm 0.025" 0.635mm 0.038" 0.965mm Mtg. Dim. M 1.06 26.9mm 1.06 26.9mm 1.25 31.7mm Mtg. Screw Size Qty #4 2 #4 2 #4 2 Wgt 0.25 lbs 0.113 kg 0.37 lbs 0.168 kg 0.53 lbs 0.240 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 12 One-4-AllTM International Transformers Printed Circuit Mount SM International Standards at Lower Cost and Better Performance CV Signal's 14A transformers are used in low power applications and provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications Power - 20 VA to 56 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual primaries (115/230V - 50/60 Hz) Secondaries - Series or parallel secondaries Electrostatic Shield - Not necessary, split or dual bobbin construction Insulation - Class F insulation (155C) Flammability Rating - Bobbin and wrap around shroud material meet UL 94V0 Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) VDE certified to VDE 0805 / EN 60950 (File #1446) VDE certified to IEC 950 f VA Part No. VA (Size) Dimensions H A Secondary RMS Rating Series Parallel (Size) 14A-20-10 14A-30-10 14A-56-10 20 30 56 10VCT @ 2.0A 10VCT @ 3.0A 10VCT @ 5.6A 14A-20-12 14A-30-12 14A-56-12 20 30 56 12.6VCT @ 1.6A 12.6VCT @ 2.4A 12.6VCT @ 4.4A 14A-20-16 14A-30-16 14A-56-16 20 30 56 16VCT @ 1.25A 16VCT @ 1.9A 16VCT @ 3.5A 8V @ 2.5A 8V @ 3.8A 8V @ 7.0A 14A-20-20 14A-30-20 14A-56-20 20 30 56 20VCT @ 1.0A 20VCT @ 1.5A 20VCT @ 2.8A 10V @ 2.0A 10V @ 3.0A 10V @ 5.6A 14A-20-24 14A-30-24 14A-56-24 20 30 56 24VCT @ 0.83A 24VCT @ 1.25A 24VCT @ 2.33 A 12V @ 1.66A 12V @ 2.50A 12V @ 4.66A 14A-20-28 14A-30-28 14A-56-28 20 30 56 28VCT @ 0.72A 28VCT @ 1.06A 28VCT @ 2.0A 14V @ 1.44A 14V @ 2.12A 14V @ 4.0A 14A-20-36 14A-30-36 14A-56-36 20 30 56 36VCT @ 0.56A 36VCT @ 0.82A 36VCT @ 1.56A 18V @ 1.12A 18V @ 1.64A 18V @ 3.12A B C Sq.Pin Dimensions M Mtg. Dim. N 0.400 10.2mm 0.400 10.2mm 1.460 37.1mm 0.038" 0.97mm 1.50 38.1mm - - - 1.56 39.7mm 0.550 13.9mm 0.275 7.0mm 1.680 42.7mm 0.045" 1.14 mm - - 1.75 44.4mm 1.81 46.0mm 0.600 15.2mm 0.300 7.6mm 1.900 48.3mm 0.045" 1.14mm - - 2.00 50.8mm L W 20 2.25 57.2mm 1.87 47.6mm 1.62 41.3mm 30 2.62 66.7mm 1.18 55.5mm 56 3.00 76.2mm 2.50 63.5mm P 5V @ 4.0A 5V @ 6.0A 5V @ 11.2A 6.3V @ 3.2A 6.3V @ 4.8A 6.3V @ 8.8A Mtg. Screw Size Qty Wgt #4 2 0.90 lbs 0.41 kg 2.18 55.5mm #6 4 1.15 lbs 0.52 kg 2.50 6.35mm #6 4 1.70 lbs 0.77 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 13 One-4-AllTM International Triple Output Transformers * Printed Circuit Mount SM For 5 VDC and 12 VDC or 15 VDC Regulated Power Supplies Which Require International Safety Certification Signal's 14A triple output transformers have pc board mount capability plus all of the performance features of our split bobbin 14A series. General Specifications Power -- 20 VA to 56 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual primaries (115/230V - 50/60 Hz) Input range (100V to 130V or 200V to 260V - 50/60 Hz) Secondaries - Dual complimentary outputs (5 VDC with 12 VDC or 5 VDC with 15 VDC) Electrostatic Shield - Not necessary, split bobbin construction Insulation - Class F insulation (155C) Flammability Rating - Bobbin and shroud material meet UL 94V0 CV Part Number VA (Size) Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) VDE certified to VDE 0805 / EN 60950 (File #4361) VDE certified to IEC 950 f DC Output Regulator I C2 C4 See Note Suggested Components Regulator II C1 C3 IC1 IC2 IC3 D1 D2 14A-20-512 20 5V @ 750mA 12V @ 200mA 2.3 KMFD 600 MFD LM-323K-5 LM-340K-12 LM-320K-12 PE20 PF20 14A-20-515 20 5V @ 750mA 15V @ 175mA 50 VDC 50 VDC @ @ 14A-30-512 30 5V @ 1.25A 12V @ 250mA 4.1 KMFD 14A-30-515 30 5V @ 1.25A 15V @ 200mA 15 VDC @ 1.1 KMFD @ 50 VDC 600 MFD @ 50 VDC 14A-56-512 56 5V @ 3A 12V @ 300mA 10.0 KMFD 1.1 KMFD 14A-56-515 56 5V @ 3A 15V @ 250mA 15 VDC Note : Note : Note : Note : 30 56 @ 50 VDC LM-340K-15 LM-320K-15 PE20 PF20 LM-340K-12 LM-320K-12 PE20 PF20 LM-323K-5 LM-340K-15 LM-320K-15 PE20 PF20 LM-338 LM-340K-12 LM-320K-12 PP20 PF20 LM-338 LM-340K-15 LM-320K-15 PP20 PF20 Output capacitors C2 and C4 are required to stabilize regulators. Values can be 1MFD min. tantalum or 10MFD min. electrolytic, 20V min. LM-338 is an adjustable regulator and MFR's specifications (National Semiconductor) should be consulted for values of external components. All IC's are National Semiconductor types. All bridges are EDI types VA (Size) 20 @ LM-323K-5 LM-323K-5 L 2.25 57.2mm 2.62 66.7mm 3.00 76.2mm Dimensions W H 1.87 1.62 47.6mm 41.3mm 2.18 1.56 55.5mm 39.7mm 2.50 1.81 63.5mm 46.0mm A 0.400 10.2mm 0.550 13.9mm 0.600 15.2mm B 0.400 10.2mm 0.275 7.0mm 0.300 7.6mm C 1.460 37.1mm 1.680 42.7mm 1.900 48.3mm D 0.200 5.1mm 0.275 7.0mm 0.300 7.6mm Sq. Pin Dimensions 0.038" 0.97mm 0.045" 1.14mm 0.045" 1.14mm M 1.50 38.1mm - - - - Mtg. Dim. N - - 1.75 44.5mm 2.00 50.8mm P - 2.18 55.4mm 2.50 63.5mm Mtg. Screw Size Qty #4 2 #6 4 #6 4 Wgt 0.90 lbs 0.41 kg 1.15 lbs 0.52 kg 1.70 lbs 0.77 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 14 FlatheadTM Low Profile Transformers Printed Circuit Mount SM For Low Power and Critical Height Applications Part No. CV Signal's LP transformers use hum-bucking (semi toroidal) construction that minimizes radiated magnetic fields. These transformers are ideal for critical low height pc board applications. General Specifications Power - 2 VA to 48 VA Dielectric Strength - 1500VRMS Hipot Primaries - Dual primaries (115V / 230V - 50/60 Hz) Secondaries - Series or parallel secondaries Electrostatic Shield - Not necessary, split bobbin construction Magnetic Field - Reduced magnetic radiation Height - .65 to 1.375 inches high Insulation - Class B insulation (130C) Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) VA (Size) 2 6 12 24 48 A 1.600 40.6mm 1.600 40.6mm 2.000 50.8mm 1.900 48.3mm 2.180 55.4mm B 0.375 9.5mm 0.375 9.5mm 0.500 12.7mm 0.600 15.2mm 0.600 15.2mm C 0.375 9.5mm 0.375 9.5mm 0.500 12.7mm 0.530 13.5mm 0.660 16.8mm L 1.87 47.5mm 1.87 47.5mm 2.50 63.5mm 2.87 72.9mm 3.12 79.2mm W 1.56 39.6mm 1.56 39.6mm 2.00 50.8mm 2.25 57.2mm 2.50 63.5mm H 0.650 16.5mm 0.850 21.6mm 1.065 27.1mm 1.250 31.8mm 1.375 34.9mm LP-10-250 LP-10-600 LP-10-1200 LP-10-2400 LP-10-4800 LP-12-200 LP-12-450 LP-12-900 LP-12-1900 LP-12-3800 LP-16-150 LP-16-350 LP-16-700 LP-16-1500 LP-16-3000 LP-20-125 LP-20-300 LP-20-600 LP-20-1200 LP-20-2400 LP-24-100 LP-24-250 LP-24-500 LP-24-1000 LP-24-2000 LP-30-85 LP-30-200 LP-30-400 LP-30-800 LP-30-1600 LP-34-75 LP-34-170 LP-34-340 LP-34-700 LP-34-1400 LP-40-60 LP-40-150 LP-40-300 LP-40-600 LP-40-1200 LP-56-45 LP-56-100 LP-56-200 LP-56-425 LP-56-850 LP-88-28 LP-88-65 LP-88-130 LP-120-20 LP-120-50 LP-120-100 LP-230-10 LP-230-25 LP-230-50 N - - - - - - 2.41 61.2mm 2.62 66.5mm VA (Size) 2 6 12 24 48 2 6 12 24 48 2 6 12 24 48 2 6 12 24 48 2 6 12 24 48 2 6 12 24 48 2 6 12 24 48 2 6 12 24 48 2 6 12 24 48 2 6 12 2 6 12 2 6 12 D .041 x .020 1.04 x 0.51mm .041 x .020 1.04 x 0.51mm .041 x .020 1.04 x 0.51mm .041(SQ pin) 1.04SQmm .041(SQ pin) 1.04SQmm Secondary RMS Rating Series Parallel 10VCT @ 250mA 5V @ 500mA 10VCT @ 600mA 5V @ 1.2A 10VCT @ 1200mA 5V @ 2.4A 10VCT @ 2.40A 5V @ 4.80A 10VCT @ 4.80A 5V @ 9.60A 12.6VCT @ 200mA 6.3V @ 400mA 12.6VCT @ 450mA 6.3V @ 900mA 12.6VCT @ 900mA 6.3V @ 1.8A 12.6VCT @ 1.90A 6.3V @ 3.80A 12.6VCT @ 3.80A 6.3V @ 7.60A 16VCT @ 150mA 8V @ 300mA 16VCT @ 350mA 8V @ 700mA 16VCT @ 700mA 8V @ 1.4A 16VCT @ 1.50A 8V @ 3.00A 16VCT @ 3.00A 8V @ 6.00A 20VCT @ 125mA 10V @ 250mA 20VCT @ 300mA 10V @ 600mA 20VCT @ 600mA 10V @ 1.2A 20VCT @ 1.20A 10V @ 2.40A 20VCT @ 2.40A 10V @ 4.80A 24VCT @ 100mA 12V @ 200mA 24VCT @ 250mA 12V @ 500mA 24VCT @ 500mA 12V @ 1A 24VCT @ 1.00A 12V @ 2.00A 24VCT @ 2.00A 12V @ 4.00A 30VCT @ 85mA 15V @ 170mA 30VCT @ 200mA 15V @ 400mA 30VCT @ 400mA 15V @ 800mA 30VCT @ 800mA 15V @ 1.60A 30VCT @ 1.60A 15V @ 3.20A 34VCT @ 75mA 17V @ 150mA 34VCT @ 170mA 17V @ 340mA 34VCT @ 340mA 17V @ 680mA 34VCT @ 700mA 17V @ 1.40A 34VCT @ 1.40A 17V @ 2.80A 40VCT @ 60mA 20V @ 120mA 40VCT @ 150mA 20V @ 300mA 40VCT @ 300mA 20V @ 600mA 40VCT @ 600mA 20V @ 1.20A 40VCT @ 1.20A 20V @ 2.40A 56VCT @ 45mA 28V @ 90mA 56VCT @ 100mA 28V @ 200mA 56VCT @ 200mA 28V @ 400mA 56VCT @ 425mA 28V @ 850mA 56VCT @ 850mA 28V @ 1.70A 88VCT @ 28mA 44V @ 56mA 88VCT @ 65mA 44V @ 130mA 88VCT @ 130mA 44V @ 260mA 120VCT @ 20mA 60V @ 40mA 120VCT @ 50mA 60V @ 100mA 120VCT @ 100mA 60V @ 200mA 230VCT @ 10mA 115V @ 20mA 230VCT @ 25mA 115V @ 50mA 230VCT @ 50mA 115V @ 100mA P - - - Clearance Hole for #4 Screw Clearance Hole for #6 Screw Wgt 5 oz 0.14 kg 7 oz 0.20 kg 11 oz 0.31 kg 15 oz 0.43 kg 21 oz 0.60 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 15 Split/TranTM Low Power Transformers SM Printed Circuit Mount -- Split Bobbin with High Isolation Signal's ST and DST transformers use a split bobbin that provides superior isolation and low capacitive coupling. General Specifications Power - 1.1 VA to 36 VA Dieletric Strength - 2500VRMS Hipot Primaries - Single or dual primaries (115V or 115/230V -50/60 Hz) Secondaries - Series or parallel secondaries Electrostatic Shield - Not necessary, split bobbin construction Insulation - Class B insulation (130C) Mounting Hardware - See chart Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) CV Part Number Single 115V Dual 115/230V 6 Pin 8 Pin Size VA L W H ML A 2 1.37" 1.12" 1.31" 1.1 34.9mm 28.6mm 23.8mm -- -- .250" 6.4mm 3 2.4 1.37" 1.12" 1.18" 34.9mm 28.6mm 30.1mm -- -- .250" 6.4mm 4 6 5 12 6 7 Optional Mtg. Screw & Nut* Wgt .250" 1.200" 6.4mm 30.5mm None 0.17 lbs 0.08 kg .250" 1.200" 6.4mm 30.5mm None 0.25 lbs 0.11 kg 4-40 x 1.37 Nylon 4-40 x 34.9mm 4-40 x 1.37 Nylon 4-40 x 34.9mm 0.44 lbs 0.20 kg 0.70 lbs 0.32 kg B C 1.62" 1.31" 1.31" 1.06 .250" 41.3mm 33.3mm 33.3mm 26.9mm 6.4mm 1.87" 1.56" 1.43" 1.25 .300" 47.6mm 39.7mm 36.5mm 31.8mm 7.6mm .350" 8.9mm .400" 10.2mm 20 2.25" 1.87" 1.43" 1.30" .300" 57.2mm 47.6mm 36.5mm 38.1mm 7.6mm .400" 1.600" 4-40 x 1.37 Nylon 0.80 lbs 10.2mm 40.6mm 4-40 x 34.9mm 0.36 kg 36 2.62" 2.18" 1.56" 66.7mm 55.5mm 39.7mm 1.280" 32.5mm 1.410" 35.8mm .400" .400" 1.850" 10.2mm 10.2mm 47.0mm 1.1 lbs 0.50 kg *Available from Signal: Part No. ST-MS (Screw) & Part No. ST-MN (Nut). Size 7 has 4 mtg. holes on 2.18 x 1.75 centers for a #6 screw. Need not be nylon. ST-2-10 ST-3-10 ST-4-10 ST-5-10 ST-6-10 ST-7-10 ST-2-12 ST-3-12 ST-4-12 ST-5-12 ST-6-12 ST-7-12 ST-2-16 ST-3-16 ST-4-16 ST-5-16 ST-6-16 ST-7-16 ST-2-20 ST-3-20 ST-4-20 ST-5-20 ST-6-20 ST-7-20 ST-2-24 ST-3-24 ST-4-24 ST-5-24 ST-6-24 ST-7-24 ST-2-28 ST-3-28 ST-4-28 ST-5-28 ST-6-28 ST-7-28 ST-2-36 ST-3-36 ST-4-36 ST-5-36 ST-6-36 ST-7-36 ST-2-48 ST-3-48 ST-4-48 ST-5-48 ST-6-48 ST-7-48 ST-2-56 ST-3-56 ST-4-56 ST-5-56 ST-6-56 ST-7-56 ST-2-120 ST-3-120 ST-4-120 ST-5-120 ST-6-120 ST-7-120 DST-2-10 DST-3-10 DST-4-10 DST-5-10 DST-6-10 DST-7-10 DST-2-12 DST-3-12 DST-4-12 DST-5-12 DST-6-12 DST-7-12 DST-2-16 DST-3-16 DST-4-16 DST-5-16 DST-6-16 DST-7-16 DST-2-20 DST-3-20 DST-4-20 DST-5-20 DST-6-20 DST-7-20 DST-2-24 DST-3-24 DST-4-24 DST-5-24 DST-6-24 DST-7-24 DST-2-28 DST-3-28 DST-4-28 DST-5-28 DST-6-28 DST-7-28 DST-2-36 DST-3-36 DST-4-36 DST-5-36 DST-6-36 DST-7-36 DST-2-48 DST-3-48 DST-4-48 DST-5-48 DST-6-48 DST-7-48 DST-2-56 DST-3-56 DST-4-56 DST-5-56 DST-6-56 DST-7-56 DST-2-120 DST-3-120 DST-4-120 DST-5-120 DST-6-120 DST-7-120 Secondary RMS Rating Series 10VCT @ 0.11A 10VCT @ 0.25A 10VCT @ 0.6A 10VCT @ 1.2A 10VCT @ 2.0A 10VCT @ 3.6A 12.6VCT @ 0.09A 12.6VCT @ 0.2A 12.6VCT @ 0.5A 12.6VCT @ 1.0A 12.6VCT @ 1.6A 12.6VCT @ 2.85A 16VCT @ 0.07A 16VCT @ 0.15A 16VCT @ 0.4A 16VCT @ 0.8A 16VCT @ 1.25A 16VCT @ 2.25A 20VCT @ 0.055A 20VCT @ 0.12A 20VCT @ 0.3A 20VCT @ 0.6A 20VCT @ 1.0A 20VCT @ 1.8A 24VCT @ 0.045A 24VCT @ 0.1A 24VCT @ 0.25A 24VCT @ 0.5A 24VCT @ 0.8A 24VCT @ 1.5A 28VCT @ 0.04A 28VCT @ 0.085A 28VCT @ 0.2A 28VCT @ 0.42A 28VCT @ 0.7A 28VCT @ 1.3A 36VCT @ 0.03A 36VCT @ 0.065A 36VCT @ 0.17A 36VCT @ 0.35A 36VCT @ 0.55A 36VCT @ 1.0A 48VCT @ 0.023A 48VCT @ 0.05A 48VCT @ 0.125A 48VCT @ 0.25A 48VCT @ 0.4A 48VCT @ 0.75A 56VCT @ 0.02A 56VCT @ 0.045A 56VCT @ 0.11A 56VCT @ 0.22A 56VCT @ 0.35A 56VCT @ 0.65A 120VCT @ 0.01A 120VCT @ 0.02A 120VCT @ 0.05A 120VCT @ 0.1A 120VCT @ 0.16A 120VCT @ 0.3A Parallel 5V @ 0.22A 5V @ 0.5A 5A @ 1.2A 5V @ 2.4A 5V @ 4.0A 5V @ 7.2A 6.3V @ 0.18A 6.3V @ 0.4A 6.3V @ 1.0A 6.3V @ 2.0A 6.3V @ 3.2A 6.3V @ 5.7A 8V @ 0.14A 8V @ 0.3A 8V @ 0.8A 8V @ 1.6A 8V @ 2.5A 8V @ 4.5A 10V @ 0.11A 10V @ 0.24A 10V @ 0.6A 10V @ 1.2A 10V @ 2.0A 10V @ 3.6A 12V @ 0.09A 12V @ 0.2A 12V @ 0.5A 12V @ 1.0A 12V @ 1.6A 12V @ 3.0A 14V @ 0.08A 14V @ 0.17A 14V @ 0.4A 14V @ 0.84A 14V @ 1.4A 14V @ 2.6A 18V @ 0.06A 18V @ 0.13A 18V @ 0.34A 18V @ 0.7A 18V @ 1.1A 18V @ 2.0A 24V @ 0.046A 24V @ 0.1A 24V @ 0.25A 24V @ 0.5A 24V @ 0.8A 24V @ 1.5A 28V @ 0.04A 28V @ 0.09A 28V @ 0.22A 28V @ 0.44A 28V @ 0.7A 28V @ 1.3A 60V @ 0.02A 60V @ 0.04A 60V @ 0.1A 60V @ 0.2A 60V @ 0.32A 60V @ 0.6A If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 16 Printed Circuit Power Transformers Printed Circuit Mount SM Miniature Low Power Transformers CV Signal's PC low power transformers are designed to operate between 50 and 500 Hz without any degradation in output voltage. General Specifications Power - 1.0 VA to 24 VA Dielectric Strength - 1500VRMS Hipot Primaries - Single or dual primaries (115V or 115/230V - 50-500 Hz) Secondaries - Series or parallel secondaries Insulation - Class B insulation (130C) Mounting Brackets - See chart Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) Primary 50/500 Hz Single 115V Dual 115/230V (6 Pin) (8 Pin) VA (Size) PC-10-90 PC-10-120 PC-10-440 PC-10-1000 PC-10-2400 PC-12-70 PC-12-100 PC-12-350 PC-12-800 PC-12-2000 PC-16-55 PC-16-75 PC-16-260 PC-16-640 PC-16-1500 PC-20-45 PC-20-60 PC-20-220 PC-20-500 PC-20-1200 PC-24-35 PC-24-50 PC-24-180 PC-24-450 PC-24-1000 PC-28-30 PC-28-40 PC-28-160 PC-28-360 PC-28-800 PC-34-25 PC-34-35 PC-34-125 PC-34-300 PC-34-700 PC-40-20 PC-40-30 PC-40-110 PC-40-250 PC-40-600 PC-56-15 PC-56-20 PC-56-80 PC-56-180 PC-56-420 PC-120-8 PC-120-10 PC-120-35 PC-120-85 1.0 1.2 4.4 10.0 24.0 1.0 1.2 4.4 10.0 24.0 1.0 1.2 4.4 10.0 24.0 1.0 1.2 4.4 10.0 24.0 1.0 1.2 4.4 10.0 24.0 1.0 1.2 4.4 10.0 24.0 1.0 1.2 4.4 10.0 24.0 1.0 1.2 4.4 10.0 24.0 1.0 1.2 4.4 10.0 24.0 1.0 1.2 4.4 10.0 DPC-10-90 DPC-10-120 DPC-10-440 DPC-10-1000 DPC-10-2400 DPC-12-70 DPC-12-100 DPC-12-350 DPC-12-800 DPC-12-2000 DPC-16-55 DPC-16-75 DPC-16-260 DPC-16-640 DPC-16-1500 DPC-20-45 DPC-20-60 DPC-20-220 DPC-20-500 DPC-20-1200 DPC-24-35 DPC-24-50 DPC-24-180 DPC-24-450 DPC-24-1000 DPC-28-30 DPC-28-40 DPC-28-160 DPC-28-360 DPC-28-800 DPC-34-25 DPC-34-35 DPC-34-125 DPC-34-300 DPC-34-700 DPC-40-20 DPC-40-30 DPC-40-110 DPC-40-250 DPC-40-600 DPC-56-15 DPC-56-20 DPC-56-80 DPC-56-180 DPC-58-420 DPC-120-8 DPC-120-10 DPC-120-35 DPC-120-85 Secondary RMS Rating Series 10VCT @ 90mA 10VCT @ 120mA 10VCT @ 440mA 10VCT @ 1.0A 10VCT @ 2.4A 12.6VCT @ 70mA 12.6VCT @ 100mA 12.6VCT @ 350mA 12.6VCT @ 800mA 12.6VCT @ 2.0A 16VCT @ 55mA 16VCT @ 75mA 16VCT @ 260mA 16VCT @ 640mA 16VCT @ 1.50A 20VCT @ 45mA 20VCT @ 60mA 20VCT @ 220mA 20VCT @ 500mA 20VCT @ 1.20A 24VCT @ 35mA 24VCT @ 50mA 24VCT @ 180mA 24VCT @ 450mA 24VCT @ 1.0A 28VCT @ 30mA 28VCT @ 40mA 28VCT @ 160mA 28VCT @ 360mA 28VCT @ 800mA 34VCT @ 25mA 34VCT @ 35mA 34VCT @ 125mA 34VCT @ 300mA 34VCT @ 700mA 40VCT @ 20mA 40VCT @ 30mA 40VCT @ 110mA 40VCT @ 250mA 40VCT @ 600mA 56VCT @ 15mA 56VCT @ 20mA 56VCT @ 80mA 56VCT @ 180mA 56VCT @ 420mA 120VCT @ 8mA 120VCT @ 10mA 120VCT @ 35mA 120VCT @ 85mA Parallel 5V @ 180mA 5V @ 240mA 5V @ 880mA 5V @ 2.0A 5V @ 4.8A 6.3V @ 140mA 6.3V @ 200mA 6.3V @ 700mA 6.3V @ 1.6A 6.3V @ 4.0A 8V @110mA 8V @ 150mA 8V @ 520mA 8V @ 1.28A 8V @ 3.0A 10V @ 90mA 10V @ 120mA 10V @ 440mA 10V @ 1.0A 10V @ 2.40A 12V @ 70mA 12V @ 100mA 12V @ 360mA 12V @ 900mA 12V @ 2.0A 14V @ 60mA 14V @ 80mA 14V @ 320mA 14V @ 720mA 14V @ 1.60A 17V @ 50mA 17V @ 70mA 17V @ 250mA 17V @ 600mA 17V @ 1.40A 20V @ 40mA 20V @ 60mA 20V @ 220mA 20V @ 500mA 20V @ 1.20A 28V @ 30mA 28V @ 40mA 28V @ 160mA 28V @ 360mA 28V @ 840mA 60V @ 16mA 60V @ 20mA 60V @ 70mA 60V @ 170mA See Table on page 38 for method of determining RMS secondary current ratings. VA (Size) 1.0 1.2 4.4 10.0 24.0 L W H 1.00 25.4mm 1.37 34.9mm 1.62 41.3mm 1.87 47.6mm 1.62 41.3mm 1.37 34.92mm 1.12 28.6mm 1.25 31.8mm 1.43 36.5mm 2.25 57.2mm 0.83 21.08mm 1.18 30.15mm 1.37 34.92mm 1.62 41.27mm 1.37 34.93mm A-6 (6 Pin) 0.250 6.35mm 0.312 7.92mm 0.400 10.16mm 0.400 10.16mm 0.400 10.16mm A-8 (8 Pin) 0.200 5.08mm 0.200 5.08mm 0.250 6.35mm 0.250 6.35mm 0.250 6.35mm B Wgt 1.230 31.2mm 1.030 26.2mm 1.130 28.7mm 1.330 38.8mm 2.130 54.1mm 2.5 oz 0.07 kg 3 oz 0.08 kg 5 oz 0.14 kg 9 oz 0.23 kg 12 oz 0.34 kg No. - - - - - - 10-BR 24-BR OPTIONAL BRACKET* MW MD - - - - - - - - - - - - 1.64 1.12 41.7mm 28.6mm 1.37 2.00 34.9mm 50.8mm *An optional "Slide On" Mounting Bracket is available for sizes 10 & 24. The brackets do not use up any extra "Floor Space" but add 1/32 to the height of the transformer. If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 17 Printed Circuit Triple Output Transformers Printed Circuit Mount SM For 5 VDC and 12 VDC or 15 VDC Regulated Power Supplies CV Signal's MPC, DMPC and MPL transformer series have all of the performance features of our PC and LP series. MPC and DMPC Series General Specifications Power - 10 VA and 24 VA Dielectric Strength - 1500VRMS Hipot Primaries - Single or dual primaries (115V or 115/230V nominal - 50-500 Hz) Input range (100V to 130V or 200V to 260V - 50/60 Hz) Secondaries - Dual complimentary outputs (5 VDC with 12 VDC or 5 VDC with 15 VDC) Insulation - Class B insulation (130C) Brackets - Available for 10 & 24 VA sizes (PN 10-BR & 24-BR) Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) MPC & DMPC TYPES Part Number Primary 50/60 Hz 115V 115/230V (8 Pin) (10) Pin DC Output Suggested Components Regulator I Regulator II Size MPC-X-12 DMPC-X-12 5 VDC 360mA 12 VDC 60mA X MPC-X-15 DMPC-X-15 5 VDC 360mA 15 VDC 50mA X MPC-Y-12 DMPC-Y-12 5 VDC 835mA 12 VDC 150mA Y MPC-Y-15 DMPC-Y-15 5 VDC 835mA 15 VDC 130mA Y C1 C2 C3 C4 2100MFD 30V 2100MFD 30V 4000MFD 20V 4000MFD 20V 2.7MFD 20V 2.7MFD 20V 2.7MFD 20V 2.7MFD 20V 250MFD 50V 250MFD 50V 1000MFD 50V 1000MFD 50V 10MFD 20V 10MFD 20V 2.7MFD 20V 2.7MFD 20V D1(2) D2(4) IC1* 1C2* 1N4001 1N4002 LM341P-5.0 LM326N 1N4001 1N4002 LM341P-5.0 LM325N 1N4001 1N4002 LM340K-5.0 LM326N 1N4001 1N4002 LM340K-5.0 LM325N *National Semiconductor (Size) X Y L W H A-8 (8 Pin) A-10 (10 Pin) B Wgt 1.87 47.6mm 1.62 41.3mm 1.43 36.5mm 2.25 57.2mm 1.62 41.3mm 1.37 34.9mm .250 6.4mm .250 6.4mm .200 5.1mm .200 5.1mm 1.300 33.0mm 2.100 53.3mm .56 lbs .25 kg .75 lbs .34 kg Optional Bracket MW MD 1.64 1.12 10-BR 41.6mm 28.6mm 1.37 2.00 24-BR 34.9mm 50.8mm No. If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 18 Printed Circuit Triple Output Transformers Low Profile Printed Circuit Mount SM For 5 VDC and 12 VDC or 15 VDC Regulated Power Supplies MPL Series General Specifications Power - 6 VA and 12 VA Dielectric Strength - 1500VRMS Hipot Primaries - Dual primaries (115/230V nominal - 50/60 Hz) Input range (100V to 130V or 200V to 260V - 50/60 Hz) Secondaries - Dual complimentary outputs (5 VDC with 12 VDC or 5 VDC with 15 VDC) Electrostatic Shield - Not necessary, split bobbin construction Magnetic Field - Reduced magnetic riadiation Height - .85 and 1.065 inches high Insulation - Class B insulation (130C) Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) CV MPL TYPES (Dual 115/230V Primary is Standard) Part Number Primary 50/60 Hz DC Output Suggested Components Regulator I Regulator II VA (Size) MPL-6-12 5 VDC 135mA 12 VDC 40mA 6 MPL-6-15 5 VDC 135mA 15 VDC 35mA 6 MPL-12-12 5 VDC 270mA 12 VDC 85mA 12 MPL-12-15 5 VDC 270mA 15 VDC 70mA 12 C1 C2 C3 C4 1000MFD 20V 1000MFD 20V 2100MFD 30V 2100MFD 30V 2.7MFD 20V 2.7MFD 20V 2.7MFD 20V 2.7MFD 20V 150MFD 50V 150MFD 50V 250MFD 50V 250MFD 50V 10MFD 20V 10MFD 20V 10MFD 20V 10MFD 20V D1(2) D2(4) IC1* 1C2* 1N4001 1N4002 LM342P-5.0 LM326N 1N4001 1N4002 LM342P-5.0 LM325N 1N4001 1N4002 LM341P-5.0 LM326N 1N4001 1N4002 LM341P-5.0 LM325N *National Semiconductor VA (Size) 6 12 L W H A B C Wgt 1.87 47.6mm 2.50 63.5mm 1.56 39.7mm 2.00 50.8mm 0.850 21.6mm 1.065 27.1mm 1.600 40.6mm 2.000 50.8mm 0.375 9.5mm 0.500 12.7mm 0.187 4.7mm 0.250 6.4mm 0.43 lbs 0.20 kg 0.68 lbs 0.31kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 19 Class 2 Transformers Printed Circuit SM Inherently or Non-inherently Limited Signal's CL2 transformers are available in printed circuit and chassis mount versions. They are supplied as inherently or non-inherently limited units that are UL 1585 recognized. General Specifications Power - 2.5 VA to 50 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual primaries (115/230V - 50/60 Hz) Secondary - Single secondary Class 2 Rating - Inherently or non-inherently limited See secondary fuse requirements in tables below Electrostatic Shield - Not necessary, split or dual bobbin construction Insulation - Class F insulation (155C) Flammability Rating - Bobbin and shroud material meet UL 94V0 Agency Standards UL recognized to UL 1585 Class 2 (File #E116583) V CL2-2.5-12 Secondary RMS Rating 12V @ .20A Secondary Fuse Reqd. N/A* CL2-2.5-24 24V @ .10A N/A* CL2-5.0-12 12V @ .42A N/A* CL2-5.0-24 24V @ .20A N/A* CL2-10-12 12V @ .83A N/A* CL2-10-24 24V @ .42A N/A* CL2-20-12 12V @ 1.66A N/A* CL2-20-24 24V @ .833A N/A* CL2-30-12 12V @ 2.50A 3.0A** CL2-30-24 24V @ 1.25A N/A* CL2-50-12 12V @ 4.20A 5.0A** CL2-50-24 24V @ 2.10A 2.5A** Part No. * Inherently limited ** Non-inherently limited Maximum secondary fuse value specified All primaries are 115/230 volt 50/60 Hz Dimensions VA (Size) 2.5 5.0 10.0 20.0 30.0 50.0 Mtg. Dim. Mtg. Screw L W H A B C Sq. Pin Dimension M N P 1.62 41.3mm 1.62 41.3mm 1.87 47.6mm 2.25 57.2mm 2.62 66.7mm 3.00 76.2mm 1.31 33.3mm 1.31 33.3mm 1.56 39.7mm 1.87 47.6mm 2.18 55.5mm 2.50 63.5mm 1.12 28.6mm 1.37 34.9mm 1.37 34.9mm 1.62 41.3mm 1.56 39.7mm 1.81 46.0mm .200 5.1mm .200 5.1mm .200 5.1mm .400 10.2mm .550 14.0mm .600 15.2mm .250 6.4mm .400 10.2mm .400 10.2mm .400 10.2mm .275 7.0mm .300 7.6mm 1.000 25.4mm 1.000 25.4mm 1.140 29.0mm 1.460 37.1mm 1.680 42.7mm 1.900 48.3mm 0.025" 0.64mm 0.025" 0.64mm 0.038" 0.97mm 0.038" 0.97mm 0.405" 1.14mm 0.405" 1.14mm 1.06 26.9mm 1.06 26.9mm 1.25 31.8mm 1.50 38.1mm - - - - - - - - - - - - 1.75 44.5mm 2.00 50.8mm - - - - - - - - 2.18 55.5mm 2.50 63.5mm Size Qty #4 2 #4 2 #4 2 #4 2 #6 4 #6 4 Wgt 0.25 lbs 0.11 kg 0.37 lbs 0.17 kg 0.53 lbs 0.24 kg 0.90 lbs 0.41 kg 1.15 lbs 0.52 kg 1.70 lbs 0.77 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 20 Class 2 Transformers Chassis Mount SM Inherently or Non-inherently Limited Signal's CL2 transformers are available in printed circuit and chassis mount versions. They are supplied as inherently or non-inherently limited units that are UL 1585 recognized. General Specifications Power - 25 VA to 80 VA Dielectric Strength - 4000VRMS Hipot Primaries - Dual primaries (115/230V - 50/60 Hz) Secondary - Single secondary Class 2 Rating - Inherently or non-inherently limited See secondary fuse requirements in tables below Electrostatic Shield - Not necessary, split or dual bobbin construction Terminals - Solder lug / quick-connect type terminals Insulation - Class F insulation (155C) Flammability Rating - Bobbin and shroud material meet UL 94V0 Agency Standards UL recognized to UL 1585 Class 2 (File #E116583) V Part No. Secondary RMS Rating Secondary Fuse Reqd. CL2-25-12 12V @ 2.10A 2.5A** CL2-25-24 24V @ 1.05A N/A* CL2-40-12 12V @ 3.33A 4.0A** CL2-40-24 24V @ 1.66A 2.0A** CL2-80-24 24V @ 3.33A 4.0A** * Inherently limited ** Non-inherently limited Maximum secondary fuse value specified All primaries are 115/230 volt 50/60 Hz Dimensions VA (Size) 25 40 80 L W H A B C 2.81 71.4mm 3.12 79.4mm 2.50 63.5mm 1.87 47.6mm 2.06 57.3mm 2.37 60.3mm 2.31 58.7mm 2.68 68.2mm 3.00 76.2mm 2.00 50.8mm 2.25 5.72mm -- -- 1.12 28.6mm 1.12 28.6mm 1.37 34.9mm .31 7.92 .31 7.92mm .31 7.92mm Terminals .187" 4.75mm .187" 4.75mm .187" 4.75mm Mtg. Style C C B Mtg. Dim. ML 2.37 60.3mm 2.81 71.4mm 2.00 50.8mm MW Mtg. Screw -- -- #6 -- #6 2.18 55.5mm #6 Wgt 1.25 lbs 0.57kg 1.6 lbs 0.73 kg 2.8 lbs 1.27 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 21 Two-4-OneTM Power Transformers Chassis Mount SM Split Bobbin with High Isolation CV Signal's 241 transformers use a split bobbin that provides superior isolation and low capacitive coupling. General Specifications Power - 2.4 VA to 100 VA Dielectric Strength - 2500VRMS Hipot Primaries - Single or dual primaries (115V or 115/230V - 50/60 Hz) Secondary - Single center tapped secondary Electrostatic Shield - Not necessary, split bobbin construction Terminals - Solder lug / quick-connect type terminals Insulation - Class B insulation (130C) Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File #LR 51265) Part Number Single 115V Dual 115/230V 241-3-10 Not Available 241-4-10 DP-241-4-10 241-5-10 DP-241-5-10 241-6-10 DP-241-6-10 241-7-10 DP-241-7-10 241-8-10 DP-241-8-10 Secondary RMS Rating 10VCT @ 10VCT @ 10VCT @ 10VCT @ 10VCT @ 10VCT @ 0.25A 0.60A 1.2A 3.0A 5.0A 10A Part Number Single 115V Dual 115/230V 241-3-28 Not Available 241-4-28 DP-241-4-28 241-5-28 DP-241-5-28 241-6-28 DP-241-6-28 241-7-28 DP-241-7-28 241-8-28 DP-241-8-28 Secondary RMS Rating 28VCT @ 0.085A 28VCT @ 0.20A 28VCT @ 0.42A 28VCT @ 1.1A 28VCT @ 2.0A 28VCT @ 3.6A 241-3-12 241-4-12 241-5-12 241-6-12 241-7-12 241-8-12 Not Available DP-241-4-12 DP-241-5-12 DP-241-6-12 DP-241-7-12 DP-241-8-12 12.6VCT @ 12.6VCT @ 12.6VCT @ 12.6VCT @ 12.6VCT @ 12.6VCT @ 0.20A 0.50A 1.0A 2.5A 4.0A 8.0A 241-3-36 241-4-36 241-5-36 241-6-36 241-7-36 241-8-36 Not Available DP-241-4-36 DP-241-5-36 DP-241-6-36 DP-241-7-36 DP-241-8-36 36VCT @ 36VCT @ 36VCT @ 36VCT @ 36VCT @ 36VCT @ 0.065A 0.17A 0.35A 0.85A 1.5A 2.8A 241-3-16 241-4-16 241-5-16 241-6-16 241-7-16 241-8-16 Not Available DP-241-4-16 DP-241-5-16 DP-241-6-16 DP-241-7-16 DP-241-8-16 16VCT @ 16VCT @ 16VCT @ 16VCT @ 16VCT @ 16VCT @ 0.15A 0.40A 0.80A 2.0A 3.5A 6.25A 241-3-48 241-4-48 241-5-48 241-6-48 241-7-48 241-8-48 Not Available DP-241-4-48 DP-241-5-48 DP-241-6-48 DP-241-7-48 DP-241-8-48 48VCT @ 48VCT @ 48VCT @ 48VCT @ 48VCT @ 48VCT @ 0.05A 0.125A 0.25A 0.63A 1.2A 2.0A 241-3-20 241-4-20 241-5-20 241-6-20 241-7-20 241-8-20 Not Available DP-241-4-20 DP-241-5-20 DP-241-6-20 DP-241-7-20 DP-241-8-20 20VCT @ 20VCT @ 20VCT @ 20VCT @ 20VCT @ 20VCT @ 0.12A 0.30A 0.60A 1.5A 2.8A 5.0A 241-3-56 241-4-56 241-5-56 241-6-56 241-7-56 241-8-56 Not Available DP-241-4-56 DP-241-5-56 DP-241-6-56 DP-241-7-56 DP-241-8-56 56VCT @ 56VCT @ 56VCT @ 56VCT @ 56VCT @ 56VCT @ 0.045A 0.11A 0.22A 0.54A 1.00A 1.8A 241-3-24 241-4-24 241-5-24 241-6-24 241-7-24 241-8-24 Not Available DP-241-4-24 DP-241-5-24 DP-241-6-24 DP-241-7-24 DP-241-8-24 24VCT @ 24VCT @ 24VCT @ 24VCT @ 24VCT @ 24VCT @ 0.10A 0.25A 0.50A 1.25A 2.4A 4.0A 241-3-120 241-4-120 241-5-120 241-6-120 241-7-120 241-8-120 Not Available DP-241-4-120 DP-241-5-120 DP-241-6-120 DP-241-7-120 DP-241-8-120 120VCT @ 120VCT @ 120VCT @ 120VCT @ 120VCT @ 120VCT @ 0.02A 0.05A 0.10A 0.25A 0.50A 0.85A See page 38 for method of determining RMS secondary current ratings. Size VA 3 2.4 4 6 5 12 6 30 7 56 8 100 L 2.06 52.3mm 2.37 60.3mm 2.81 71.4mm 3.25 82.6mm 3.68 93.7mm 4.03 102.4mm W 1.06 26.9mm 1.25 31.8mm 1.37 34.9mm 1.68 42.8mm 1.81 46.0mm 2.25 57.2mm Dimensions H 1.18 30.1mm 1.37 34.9mm 1.62 41.3mm 1.93 49.2mm 2.25 57.2mm 2.56 65.1mm A 1.62 41.3mm 1.68 42.8mm 1.93 49.2mm 2.31 58.7mm 2.68 68.2mm 3.06 77.7mm B 0.56 14.3mm 0.68 17.4mm 0.81 20.6mm 1.06 26.9mm 1.06 26.9mm 1.31 33.3mm ML 1.75 44.5mm 2.00 50.8mm 2.37 60.3mm 2.81 71.4mm 3.12 79.4mm 3.50 90.5mm Wgt 0.25 lbs 0.11 kg 0.44 lbs 0.20 kg 0.7 lbs 0.32 kg 1.1 lbs 0.50 kg 1.7 lbs 0.77 kg 2.75 lbs 1.25 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 22 Two-4-OneTM Triple Output Transformers * Chassis Mount SM For 5 VDC and 12 VDC or 15 VDC Regulated Power Supplies CV Part Number Primary 50/60 Hz Signal's MT and DMT transformers have all of the performance features of our 241 series. General Specifications Power - 30 VA, 56 VA, and 100 VA Dielectric Strength - 2500VRMS Hipot Primaries - Single or dual primaries (115V or 115/230V nominal - 50/60Hz) Input range (100V to 130V or 200V to 260V - 50/60 Hz) Secondaries - Dual complimentary outputs (5 VDC with 12 VDC or 5 VDC with 15 VDC Electrostatic Shield - Not necessary, split bobbin construction Terminals - Solder lug / quick-connect type terminals Insulation - Class B insulation (130C) Agency Standards UL recognized to UL 506 (File #E63829) CSA certified to C22.2 #66 (File # LR 51265) DC Output 115V 115/230V Regulator I Regulator II MT-6-12 MT-6-15 MT-7-12 MT-7-15 MT-8-12 MT-8-15 DMT-6-12 DMT-6-15 DMT-7-12 DMT-7-15 DMT-8-12 DMT-8-15 5V @ 1.75A 5V @ 1.75A 5V @ 2.8A 5V @ 2.8A 5V @ 4A 5V @ 4A 12V @ 210mA 15V @ 175mA 12V @ 350mA 15V @ 280mA 12V @ 600mA 15V @ 500mA C2 C4 See Note Suggested Components Size 6 6 7 7 8 8 C1 C3 1C1 IC2 IC3 D1 D2 10 KMFD @ 20 VDC 15 KMFD @ 20 VDC 26 KMFD @ 20 VDC 1.5 KMFD @ 50 VDC 2 KMFD @ 50 VDC 3.1 KMFD @ 50 VDC LM-323K-5 LM-323K-5 LM-323K-5 LM-323K-5 LM-338 LM-338 LM-340K-12 LM-340K-15 LM-340K-12 LM-340K-15 LM-340K-12 LM-340K-15 LM-320K-12 LM-320K-15 LM-320K-12 LM-320K-15 LM-320K-12 LM-320K-15 3N253 3N253 MDA-400 MDA-400 MDA-800 MDA-800 3N247 3N247 3N247 3N247 3N247 3N247 Note : Output capacitors C2 and C4 are required to stablize regulators. Values can be 1MFD min. tantalum or 10MFD min. electrolytic, 20 V min. Note : LM-338 is an adjustable regulator and MFR's specifications (National Semiconductor) should be consulted for values of external components. Note : All IC's are National Semiconductor types. Note : All diodes are Motorola types. VA (Size) 6 7 8 L 3.25 82.6mm 3.68 93.6mm 4.03 102.4mm W 1.75 31.8mm 1.81 46.0mm 2.25 57.2mm Dimensions H A 1.93 2.31 49.2mm 58.7mm 2.25 2.68 57.2mm 68.2mm 2.56 3.06 65.1mm 77.7mm B 1.06 26.9mm 1.06 26.9mm 1.31 33.3mm ML 2.81 71.4mm 3.12 79.4mm 3.56 90.5mm Wgt 1.1 lbs 0.50 kg 1.7 lbs 0.77 kg 2.75 lbs 1.25 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 23 Conventional Rectifier Power Transformers * Chassis Mount SM Signal's Rectifier Power transformers provide a wide variety of outputs. This series of conservatively designed transformers are manufactured using traditional materials and layer wound techniques. General Specifications Power - 10 VA to 2800 VA Primary 50/60 HZ Single Dual* 115V 115/230V Dielectric Strength - 1500VRMS Hipot Primaries - Single, tapped, or dual primaries (105V, 115V, 125V, 230V - 50-500 Hz) Secondaries - Center-tapped series or center-tapped parallel secondaries Insulation - Class A insulation (105C) Secondary RMS Rating Series Parallel Mtg. Style 10-1 DL-10-1 10VCT @ 1A 5VCT @ 2A C 10-2 DL-10-2 10VCT @ 2A 5VCT @ 4A C 10-4 DL-10-4 10VCT @ 4A 5VCT @ 8A C 10-6 DL-10-6 10VCT @ 6A 5VCT @ 12A B 10-8 DL-10-8 10VCT @ 8A 5VCT @ 16A B 10-12 DL-10-12 10VCT @ 12A 5VCT @ 24A B 10-25 DL-10-25 10VCT @ 25A 5VCT @ 50A B 10-50 DL-10-50 10VCT @ 50A 5VCT @ 100A B 5VCT @ 200A B 10-100 DL-10-100 12.8-1 DL-12.8-1 12.8VCT @ 1A 10VCT @ 100A 6.4VCT @ 2A C 12.8-2 DL-12.8-2 12.8VCT @ 2A 6.4VCT @ 4A B 12.8-4 DL-12.8-4 12.8VCT @ 4A 6.4VCT @ 8A B 12.8-6 DL-12.8-6 12.8VCT @ 6A 6.4VCT @ 12A B 12.8-8 DL-12.8-8 12.8VCT @ 8A 6.4VCT @ 16A B 12.8-12 DL-12.8-12 12.8VCT @ 12A 6.4VCT @ 24A B 12.8-25 DL-12.8-25 12.8VCT @ 25A 6.4VCT @ 50A B 12.8-50 DL-12.8-50 12.8VCT @ 50A 6.4VCT @ 100A B 12.8-100 DL-12.8-100 12.8VCT @ 100A 6.4VCT @ 200A B 16-1 DL-16-1 16VCT @ 1A 8VCT @ 2A C 16-2 DL-16-2 16VCT @ 2A 8VCT @ 4A C 16-4 DL-16-4 16VCT @ 4A 8VCT @ 8A B 16-6 DL-16-6 16VCT @ 6A 8VCT @ 12A B 16-8 DL-16-8 16VCT @ 8A 8VCT @ 16A B 16-12 DL-16-12 16VCT @ 12A 8VCT @ 24A B 16-25 DL-16-25 16VCT @ 25A 8VCT @ 50A B 16-50 DL-16-50 16VCT @ 50A 8VCT @ 100A B 16-100 DL-16-100 16VCT @ 100A 8VCT @ 200A B Available with dual primary only. Therefore, prefix "DL" is not required. Nominal 115V primary has added taps, I.E., 105/115/125V; Dual (DL) version is 115/230V only. L W H ML MW 2.87 73.0mm 3.12 79.4mm 3.56 90.5mm 3.37 85.7mm 3.37 85.7mm 3.75 95.3mm 4.50 114.3mm 5.25 133.4mm 6.37 162.0mm 2.87 73.0mm 3.00 76.2mm 3.00 76.2mm 3.37 85.7mm 3.75 95.3mm 4.12 104.8mm 5.25 133.4mm 5.25 133.4mm 6.37 162.0mm 2.87 73.0mm 3.12 79.4mm 3.37 85.7mm 3.75 95.3mm 3.75 95.3mm 4.12 104.8mm 4.50 114.3mm 6.37 162.0mm 7.50 190.5mm 1.75 44.5mm 2.12 53.9mm 2.37 60.3mm 2.75 69.9mm 3.12 79.4mm 3.25 82.6mm 3.75 95.3mm 5.50 139.7mm 7.25 184.2mm 2.00 50.8mm 2.50 63.5mm 2.87 73.0mm 3.06 77.7mm 3.12 79.4mm 3.25 82.6mm 4.25 108.0mm 6.00 152.4mm 7.25 184.2mm 2.00 50.8mm 2.25 57.2mm 2.75 69.9mm 3.12 79.4mm 3.50 89.0mm 3.87 98.4mm 5.37 136.5mm 5.70 146.1mm 7.50 190.5mm 2.31 58.7mm 2.75 69.9mm 3.06 77.7mm 2.81 71.4mm 2.81 71.4mm 3.12 79.4mm 3.75 95.3mm 4.37 111.1mm 5.31 134.9mm 2.31 58.7mm 2.50 63.5mm 2.50 63.5mm 2.81 71.4mm 3.12 79.4mm 3.43 87.3mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 2.31 58.7mm 2.75 69.9mm 2.81 71.4mm 3.12 79.4mm 3.12 79.4mm 3.43 87.3mm 3.75 95.3mm 5.31 134.9mm 6.37 162.0mm 2.37 60.3mm 2.81 71.4mm 3.12 79.4mm 2.81 71.4mm 2.81 71.4mm 3.12 79.4mm 3.75 95.3mm 4.37 111.1mm 5.31 134.9mm 2.37 60.3mm 2.50 63.5mm 2.50 63.5mm 2.81 71.4mm 3.12 79.4mm 3.43 87.3mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 2.37 60.3mm 2.81 71.4mm 2.81 71.4mm 3.12 79.4mm 3.12 79.4mm 3.43 87.3mm 3.75 95.3mm 5.31 134.9mm 6.75 171.5mm - - - - - - 2.12 53.9mm 2.50 63.5mm 2.50 63.5mm 2.75 69.9mm 3.62 92.1mm 4.37 111.1mm - - 2.00 50.8mm 2.37 60.3mm 2.50 63.5mm 2.25 57.2mm 2.37 60.3mm 2.87 73.0mm 4.12 104.8mm 4.37 111.1mm - - - - 2.12 53.9mm 2.25 57.2mm 2.62 66.7mm 3.00 76.2mm 4.00 101.6mm 3.75 95.3mm 4.62 117.5mm Mtg. Screw #8 #8 #8 #8 #8 #8 #10 1/4 1/4 #8 #8 #8 #8 #8 #10 #10 1/4 1/4 #8 #8 #8 #10 #10 #10 #10 1/4 1/4 Wgt 1.0 lbs .45 kg 1.5 lbs .68 kg 2.3 lbs 1.04 kg 3.3 lbs 1.50 kg 4.0 lbs 1.81 kg 5.0 lbs 2.27 kg 8.7 lbs 3.95 kg 17.0 lbs 7.71 kg 34.5 lbs 15.65 kg 1.2 lbs .54 kg 2.3 lbs 1.04 kg 2.8 lbs 1.27 kg 4.0 lbs 1.81 kg 4.5 lbs 2.04 kg 6.0 lbs 2.72 kg 12.5 lbs 5.69 kg 20.7 lbs 9.39 kg 34.5 lbs 15.65 kg 1.2 lbs .54 kg 1.7 lbs .77 kg 3.3 lbs 1.50 kg 4.5 lbs 2.04 kg 5.4 lbs 2.45 kg 7.9 lbs 3.58 kg 14.5 lbs 6.58 kg 26.5 lbs 12.02 kg 50.0 lbs 22.68 kg *Items are not normally in stock. They are standard designs generally available in 3-4 weeks. See page 38 for determining RMS secondary current ratings. If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 24 Conventional Rectifier Power Transformers * Chassis Mount (continued) SM Primary 50/60 HZ Single Dual* 115V 115/230V Second RMS Rating Series Parallel Mtg. Style 24-1 DL-24-1 24VCT @ 1A 12VCT @ 2A B 24-2 DL-24-2 24VCT @ 2A 12VCT @ 4A B 24-4 DL-24-4 24VCT @ 4A 12VCT @ 8A B 24-6 DL-24-6 24VCT @ 6A 12V.C.T. @ 12A B 24-8 DL-24-8 24VCT @ 8A 12VCT @ 16A B 24-12 DL-24-12 24VCT @ 12A 12VCT @ 24A B 24-20 DL-24-20 24VCT @ 20A 12VCT @ 40A B 24-25 DL-24-25 24VCT @ 25A 12VCT @ 50A B 24-50 DL-24-50 24VCT @ 50A 12VCT @ 100A B -- 24-100 24VCT @ 100A 12VCT @ 200A B 36-1 DL-36-1 36VCT @ 1A 18VCT @ 2A B 36-2 DL-36-2 36VCT @ 2A 18VCT @ 4A B 36-4 DL-36-4 36VCT @ 4A 18VCT @ 8A B 36-6 DL-36-6 36VCT @ 6A 18VCT @ 12A B 36-8 DL-36-8 36VCT @ 8A 18VCT @ 16A B 36-12 DL-36-12 36VCT @ 12A 18VCT @ 24A B 36-20 DL-36-20 36VCT @ 20A 18VCT @ 40A B 36-25 DL-36-25 36VCT @ 25A 18VCT @ 50A B 36-30 DL-36-30 36VCT @ 30A 18VCT @ 60A B -- 36-50 36VCT @ 50A 18VCT @ 100A B Available with dual primary only. Therefore, prefix "DL" is not required. Nominal 115V primary has added taps, I.E., 105/115/125V; Dual (DL) version is 115/230V only. L W H ML MW 3.00 76.2mm 3.00 76.2mm 3.75 95.3mm 4.12 104.8mm 4.12 104.8mm 4.50 114.3mm 5.25 133.4mm 5.25 133.4mm 6.37 162.0mm 7.50 190.5mm 3.00 76.2mm 3.37 85.7mm 4.12 104.8mm 4.50 114.3mm 4.50 114.3mm 5.25 133.4mm 6.37 162.0mm 6.37 162.0mm 6.37 162.0mm 6.37 162.0mm 2.50 63.5mm 2.87 73.0mm 3.12 79.4mm 3.25 82.6mm 3.87 98.4mm 4.50 114.3mm 4.75 120.7mm 5.62 142.9mm 6.25 158.8mm 7.00 177.8mm 2.75 69.9mm 2.93 74.6mm 3.37 85.7mm 3.75 95.3mm 4.50 114.3mm 5.00 127.0mm 5.37 136.5mm 5.75 146.1mm 6.00 152.4mm 7.25 184.2m 2.50 63.5mm 2.50 63.5mm 3.12 79.4mm 3.43 87.3mm 3.43 87.3mm 3.75 95.3mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 6.37 162.0mm 2.50 63.5mm 2.81 71.4mm 3.43 87.3mm 3.75 95.3mm 3.75 95.3mm 4.37 111.1mm 5.31 134.9mm 5.31 134.9mm 5.31 134.9mm 5.31 134.9mm 2.50 63.5mm 2.50 63.5mm 3.12 79.4mm 3.43 87.3mm 3.43 87.3mm 3.75 95.3mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 6.37 162.0mm 2.50 63.5mm 2.81 71.4mm 3.43 87.3mm 3.75 95.3mm 3.75 95.3mm 4.37 111.1mm 5.31 134.9mm 5.31 134.9mm 5.31 134.9mm 5.31 134.9mm 2.00 50.8mm 2.37 60.3mm 2.25 57.2mm 2.37 60.3mm 3.00 76.2mm 3.37 85.7mm 3.37 85.7mm 4.12 104.8mm 4.37 111.1mm 4.12 104.8mm 2.25 57.2mm 2.37 60.3mm 2.62 66.7mm 2.75 69.9mm 3.37 85.7mm 3.37 85.7mm 3.37 85.7mm 3.75 95.3mm 4.37 111.1mm 5.12 130.2mm Mtg. Screw #8 #8 #8 #10 #10 #10 1/4 1/4 1/4 1/4 #8 #8 #10 #10 #10 1/4 1/4 1/4 1/4 1/4 Wgt 2.3 lbs 1.04 kg 2.9 lbs 1.32 kg 4.5 lbs 2.04 kg 5.8 lbs 2.63 kg 7.9 lbs 3.58 kg 11.0 lbs 4.99 kg 15.3 lbs 6.95 kg 19.5 lbs 8.85 kg 31.3 lbs 14.20 kg 43.0 lbs 19.5 kg 2.6 lbs 1.18 kg 3.8 lbs 1.72 kg 6.8 lbs 3.08 kg 8.7 lbs 3.95 kg 11.0 lbs 4.99 kg 15.0 lbs 6.80 kg 22.8 lbs 10.34 kg 26.5 lbs 12.02 kg 31.5 lbs 14.28 kg 40.0 lbs 18.14 kg *Items are not normally in stock. They are standard designs generally available in 3-4 weeks. See page 38 for determining RMS secondary current ratings. If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 25 Conventional Rectifier Power Transformers * Chassis Mount (continued) SM Primary 50/60 HZ Single Dual* 115V 115/230V Second RMS Rating Series Parallel Mtg. Style 56-1 DL-56-1 56VCT @ 1A 28VCT @ 2A B 56-2 DL-56-2 56VCT @ 2A 28 VCT @ 4A B 56-4 DL-56-4 56VCT @ 4A 28VCT @ 8A B 56-6 DL-56-6 56VCT @ 6A 28VCT @ 12A B 56-8 DL-56-8 56VCT @ 8A 28VCT @ 16A B 56-12 DL-56-12 56VCT @ 12A 28VCT @ 24A B 56-25 DL-56-25 56VCT @ 25A 28VCT @ 50A B -- 56-50 56VCT @ 50A 28VCT @ 100A B 68-1 DL-68-1 68VCT @ 1A 34VCT @ 2A B 68-2 DL-68-2 68VCT @ 2A 34VCT @ 4A B 68-4 DL-68-4 68VCT @ 4A 34VCT @ 8A B 68-6 DL-68-6 68VCT @ 6A 34VCT @ 12A B 68-8 DL-68-8 68VCT @ 8A 34VCT @ 16A B 68-12 DL-68-12 68VCT @ 12A 34VCT @ 24A B -- 68-25 68VCT @ 25A 34VCT @ 50A B 80-1 DL-80-1 80VCT @ 1A 40VCT @ 2A B 80-2 DL-80-2 80VCT @ 2A 40VCT @ 4A B 80-4 DL-80-4 80VCT @ 4A 40VCT @ 8A B 80-6 DL-80-6 80VCT @ 6A 40VCT @ 12A B 80-8 DL-80-8 80VCT @ 8A 40VCT @ 16A B 80-12 DL-80-12 80VCT @ 12A 40VCT @ 24A B -- 80-25 80VCT @ 25A 40VCT @ 50A B Available with dual primary only. Therefore, prefix "DL" is not required. Nominal 115V primary has added taps, I.E., 105/115/125V; Dual (DL) version is 115/230V only. L W H ML MW 3.37 85.7mm 3.75 95.3mm 4.12 104.8mm 5.25 133.4mm 5.25 133.4mm 6.37 162.0mm 6.37 162.0mm 7.50 190.5mm 3.37 85.7mm 4.12 104.8mm 4.50 114.3mm 5.25 133.4mm 5.25 133.4mm 6.37 162.0mm 6.37 162.0mm 3.37 85.7mm 4.12 104.8mm 5.25 133.4mm 5.25 133.4mm 6.37 162.0mm 6.37 162.0mm 7.50 190.5mm 2.87 73.0mm 3.25 82.6mm 3.75 95.3mm 4.25 108.0mm 5.00 127.0mm 5.25 133.4mm 7.12 181.0mm 7.50 190.5mm 2.93 74.6mm 3.37 85.7mm 4.50 114.3mm 5.00 127.0mm 5.50 139.7mm 5.75 146.1mm 7.25 184.2mm 3.06 77.7mm 3.37 85.7mm 4.25 108.0mm 5.50 139.7mm 5.25 133.4mm 6.00 152.4mm 6.50 165.1mm 2.81 71.4mm 3.12 79.4mm 3.43 87.3mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 5.31 134.9mm 6.24 158.8mm 2.81 71.4mm 3.43 87.3mm 3.75 95.3mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 5.31 134.9mm 2.81 71.4mm 3.43 87.3mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 5.31 134.9mm 6.25 158.8mm 2.81 71.4mm 3.12 79.4mm 3.43 87.3mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 5.31 134.9mm 6.75 171.5mm 2.81 71.4mm 3.43 87.3mm 3.75 95.3mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 5.31 134.9mm 2.81 71.4mm 3.43 87.3 mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 5.31 134.9mm 6.75 171.5mm 2.25 57.2mm 2.50 63.5mm 3.00 76.2mm 2.87 73.0mm 3.62 92.1mm 3.37 85.7mm 5.12 130.2mm 4.87 123.8mm 2.37 60.3mm 2.62 66.7mm 3.37 85.7mm 3.37 85.7mm 3.87 98.4mm 3.75 95.3mm 5.12 130.2mm 2.50 63.5mm 2.62 66.7mm 2.87 73.0mm 3.87 98.4mm 3.25 82.6mm 4.12 104.8mm 3.87 98.4mm Mtg. Screw #8 #8 #10 #10 #1/4 1/4 1/4 1/4 #8 #10 #10 1/4 1/4 1/4 1/4 #8 #10 1/4 1/4 1/4 1/4 1/4 Wgt 3.5 lbs 1.59 kg 5.0 lbs 2.27 kg 7.7 lbs 3.49 kg 12.0 lbs 5.44 kg 17.0 lbs 7.71 kg 22.0 lbs 9.98 kg 38.0 lbs 17.24 kg 56.3 lbs 25.54 kg 3.8 lbs 1.72 kg 6.8 lbs 3.08 kg 11.5 lbs 5.22 kg 15.0 lbs 6.80 kg 19.0 lbs 8.62 kg 26.5 lbs 12.02 kg 39.7 lbs 18.01 kg 4.0 lbs 1.81 kg 6.8 lbs 3.08 kg 12.3 lbs 5.58 kg 19.0 lbs 8.62 kg 20.5 lbs 9.30 kg 29.0 lbs 13.15 kg 40.3 lbs 18.28 kg *Items are not normally in stock. They are standard designs generally available in 3-4 weeks. See page 38 for determining RMS secondary current ratings. If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 26 Filter and Dual Chokes Chassis Mount SM Available in Single and Dual Windings Signal's CH and CL chokes are designed to compliment the rectifier power transformers so that a set may be specified for DC power supplies using inductive filters. General Specifications Inductance - 0.12 MHY to 100 MHY DC Current - 1.0 ADC to 200 ADC Insulation - Class A insulation (105C) Part No. Inductance (MHY) Current (Amps) Resistance (Ohms) Mtg. Style CH-1 100 1 1.5 B CH-2 70 2 0.9 B CH-4 70 4 0.6 B CH-6 40 6 0.4 B CH-8 30 8 0.3 B CH-12 15 12 0.1 B CH-16 15 16 0.08 B CH-20 7 20 0.05 B CH-25 5 25 0.025 B CH-30 4 30 0.01 B CH-50 1.4 50 0.01 B CH-100 0.5 100 0.005 B CH-200 0.3 200 0.001 B Part No. Series Connected Ind. Curr. Res. (MHY) (Amps) Mtg. Screw L W H ML MW 3.00 76.2mm 3.37 85.7mm 3.75 95.3mm 3.75 95.3mm 4.12 104.8mm 5.25 133.4mm 5.25 133.4mm 5.25 133.4mm 5.25 133.4mm 6.37 161.9mm 6.37 161.9mm 6.37 161.9mm 7.50 190.5mm 2.50 63.5mm 2.75 69.9mm 3.12 79.4mm 3.62 92.1mm 3.62 92.1mm 4.00 101.6mm 4.62 117.5mm 4.00 101.6mm 4.75 120.7mm 5.00 127.0mm 5.25 133.4mm 6.25 158.8mm 7.50 190.5mm 2.50 63.5mm 2.87 73.0mm 3.25 82.6mm 3.25 82.6mm 3.50 88.9mm 4.43 112.7mm 4.43 112.7mm 4.43 112.7mm 4.43 112.7mm 5.37 136.5mm 5.37 136.5mm 5.37 136.5mm 6.25 158.8mm 2.50 63.5mm 2.81 71.4mm 3.12 79.4mm 3.12 79.4mm 3.43 87.3mm 4.37 111.1mm 4.37 111.1mm 4.37 111.1mm 4.37 111.1mm 5.31 134.9mm 5.31 134.9mm 5.31 134.9mm 6.75 171.5mm 2.00 50.8mm 2.12 53.9mm 2.50 63.5mm 3.00 76.2mm 3.00 76.2mm 3.12 79.4mm 3.62 92.0mm 3.12 98.4mm 3.87 98.4mm 3.37 85.7mm 3.75 95.3mm 4.12 104.8mm 4.12 104.8mm Parallel Connected Ind. Curr. Res. (MHY) (Amps) Mtg. Style CL-1-2 72 1 1.4 18 2 0.35 C CL-2-4 40 2 0.7 10 4 0.18 C CL-4-8 20 4 0.3 5 8 0.075 B CL-6-12 12 6 0.15 3 12 0.038 B CL-12-24 4.8 12 0.052 1.2 24 0.013 B CL-25-50 1.2 25 0.012 0.3 50 0.003 B CL-50-100 0.5 50 0.0043 0.12 100 0.0011 B #8 #8 #8 #8 #10 #10 #10 #10 #10 1/4 1/4 1/4 1/4 Dimensions L W H ML 2.87 73.0mm 3.12 79.4mm 3.00 76.2mm 3.37 85.7mm 3.37 85.7mm 3.75 98.3mm 4.50 114.3mm 1.75 44.5mm 2.12 53.9mm 2.87 73.0mm 3.06 77.7mm 3.56 90.5mm 3.37 85.7mm 3.75 95.3mm 2.31 58.7mm 2.75 69.9mm 2.50 63.5mm 2.81 71.4mm 2.81 71.4mm 3.37 85.7mm 3.75 95.3mm 2.37 60.3mm 2.81 71.4mm 2.50 63.5mm 2.81 71.4mm 2.81 71.4mm 3.12 79.4mm 3.75 95.3mm MW Mtg. Screw -- #8 -- #8 2.50 63.5mm 2.50 63.5mm 3.00 76.2mm 2.75 69.9mm 2.50 63.5mm Wgt 2.3 lbs 1.04 kg 3.2 lbs 1.45 kg 5.3 lbs 2.40 kg 6.5 lbs 2.95 kg 8 lbs 3.63 kg 13.7lbs 6.21 kg 17.5 lbs 7.94 kg 13.3 lbs 6.03 kg 17.8 lbs 8.07 kg 24.4 lbs 11.07 kg 26.7 lbs 12.11 kg 31.4 lbs 14.24 kg 48.0 lbs 21.77 kg #8 #8 #8 #8 #8 Wgt 0.9 lbs 0.41 kg 1.5 lbs 0.68 kg 3.0 lbs 1.36 kg 4.0 lbs 1.81 kg 5.3 lbs 2.40 kg 6.0 lbs 2.72 kg 8.0 lbs 3.63 kg Signal's Dual Chokes are supplied with 2 windings which may be series or parallel connected with rating shown on chart. This line is basically designed for application requiring lower inductance value at high currents, such as low voltage, DC supplies or SCR filters. See page 38 for determining RMS secondary current ratings. If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 27 Power Isolation Transformers SM Industrial Grade Step-Up or Step-Down Transformers Signal's DU and SU transformers have been designed to provide a multitude of step-up or step-down voltages to accommodate the various input voltages available throughout the world. General Specifications Power - 250 VA to 10 KVA (500 VA to 20 KVA possible if used as auto-transformer) Dielectric Strength - 2500VRMS Hipot Primaries - Dual/tapped primaries: Parallel connected (104V, 110V, 120V - 50-500 Hz) Series connected (208V, 220V, 230V, 240V - 50-500 Hz) Secondaries - Dual/tapped secondaries: DU Series Parallel connected (104V, 110V, 120V - 50-500 Hz) Series connected (208V, 220V, 230V, 240V - 50-500 Hz) Electrostatic Shield - 2 mil thick copper foil connected to ground. The connection may be opened if an ungrounded shield is desired. Terminals - Plated brass screw type terminals Insulation - Class A insulation (105C) As shown on the schematic diagram the "DU" line is designed with dual primaries and secondaries. All four windings are identically rated at 0/104/110/120 volts. This permits series or parallel connections on either primary or secondary. Therefore, a nominal 110 to 110 volt, 220 to 220 volt,110 to 220 volt, or 220 to 110 volt transformer can be set up. The winding taps permit intermediate series ratings such as 208, 214, or 230 volts. It is also possible to make auto-transformer connections by connecting a primary group in series with a secondary group. Such nominal ratings as 440 to 220 volts or 220 to 440 volts can be set up, in addition to the standard ratings described above. A further advantage to auto-transformer connection is the fact that the KVA rating of a particular type is doubled. Series Secondaries Max. Volts Amps Parallel Secondaries Max. Volts Amps Part No. KVA DU-1/4 1/4 0/208/220/240 1.1 0/104/110/120 2.2 DU-1/2 1/2 0/208/220/240 2.3 0/104/110/120 4.6 DU-1 1 0/208/220/240 4.5 0/104/110/120 9 DU-2 2 0/208/220/240 9 0/104/110/120 18 DU-3 3 0/208/220/240 14 0/104/110/120 28 DU-5 5 0/208/220/240 23 0/104/110/120 46 DU-7.5 7.5 0/208/220/240 31 0/104/110/120 62 DU-10 10 0/208/220/240 41 0/104/110/120 82 L * 5.31 134.9mm 5.31 134.9mm 7.56 192.1mm 7.56 192.1mm 7.56 192.1mm 7.56 192.1mm 9.00 228.6mm 9.00 228.6mm Mechanical Dimensions W H ML * * 4.25 5.25 4.37 107.9mm 133.4mm 111.1mm 5.31 5.25 4.37 134.9mm 133.4mm 111.1mm 6.25 7.37 6.75 158.8mm 187.3mm 171.5mm 8.25 7.37 6.75 209.6mm 187.3mm 171.5mm 9.25 7.37 6.75 234.9mm 187.3mm 171.5mm 10.75 7.37 6.75 273.1mm 187.3mm 171.5mm 10.75 8.00 7.50 273.1mm 203.2mm 190.5mm 13.00 8.00 7.50 330.2mm 203.2mm 190.5mm MW 2.50 63.5mm 3.62 92.1mm 4.12 104.8mm 6.00 152.4mm 7.00 177.8mm 8.50 215.9mm 6.50 165.1mm 9.00 228.6mm Mtg. & Term. Screw #10 #10 1/4 1/4 1/4 1/4 1/4 1/4 Wgt 12 lbs 5.44 kg 18 lbs 8.16 kg 33 lbs 14.97 kg 56 lbs 25.40 kg 70 lbs 31.75 kg 89 lbs 40.37 kg 105 lbs 47.63 kg 150 lbs 68.04 kg *Maximum 0.6 (1.6mm) .12 (3.2mm) If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 28 Power Isolation Transformers SM Industrial Grade Step-Up or Step-Down Transformers Signal's DU and SU transformers have been designed to provide a multitude of step-up or step-down voltages to accommodate the various input voltages available throughout the world. General Specifications Power - 250 VA to 10 KVA (500 VA to 20 KVA possible if used as auto-transformer) Dielectric Strength - 2500VRMS Hipot Primaries - Dual/tapped primaries: Parallel connected (104V, 110V, 120V - 50-500 Hz) Series connected (208V, 220V, 230V, 240V - 50-500 Hz) Secondaries - Dual/tapped secondaries: SU Series Parallel connected (208V, 220V, 240V - 50-500 Hz) Series connected (416V, 440V, 460V, 480V - 50-500Hz) Electrostatic Shield - 2 mil thick copper foil connected to ground. The connection may be opened if an ungrounded shield is desired. Terminals - Plated brass screw type terminals Insulation - Class A insulation (105C) As shown on the schematic diagram the "SU" line is designed with dual primaries and secondaries. Two primary windings are identically rated at 0/104/110/120. Two secondary windings are identically rated at 0/208/220/240. This permits series or parallel connections on either primary or secondary. Therefore a nominal 110 to 220 volt, 220 to 440 volt, 110 to 440 volt, or 440 to 110 volt transformer can be set up. The winding tape permits intermediate series ratings such as 416, 428, and 460 volts. It is also possible to make auto-transformer connections by connecting a primary group in series with a secondary group. Such nominal ratings as 660 to 330 volts or 330 to 660 volts can be set up, in addition to the standard ratings described above. A further advantage to auto-transformer connection is the fact that the KVA rating of a particular type is doubled. Series Secondaries Max. Volts Amps Parallel Secondaries Max. Volts Amps Part No. KVA SU-1/4 1/4 0/416/440/480 0.55 0/208/220/240 1.1 SU-1/2 1/2 0/416/440/480 1.15 0/208/220/240 2.3 SU-1 1 0/416/440/480 2.25 0/208/220/240 4.5 SU-2 2 0/416/440/480 4.5 0/208/220/240 9 SU-3 3 0/416/440/480 7 0/208/220/240 14 SU-5 5 0/416/440/480 11.5 0/208/220/240 23 SU-7.5 7.5 0/416/440/480 15.5 0/208/220/240 31 SU-10 10 0/416/440/480 20.5 0/208/220/240 41 L * 5.31 134.9mm 5.31 134.9mm 7.56 192.1mm 7.56 192.1mm 7.56 192.1mm 7.56 192.1mm 9.00 228.6mm 9.00 228.6mm Mechanical Dimensions W H ML * * 4.25 5.25 4.37 107.9mm 133.4mm 111.1mm 5.31 5.25 4.37 134.9mm 133.4mm 111.1mm 6.25 7.37 6.75 158.8mm 187.3mm 171.5mm 8.25 7.37 6.75 209.6mm 187.3mm 171.5mm 9.25 7.37 6.75 234.9mm 187.3mm 171.5mm 10.75 7.37 6.75 273.1mm 187.3mm 171.5mm 10.75 8.00 7.50 273.1mm 203.2mm 190.5mm 13.00 8.00 7.50 330.2mm 203.2mm 190.5mm MW 2.50 63.5mm 3.62 92.1mm 4.12 104.8mm 6.00 152.4mm 7.00 177.8mm 8.50 215.9mm 6.50 165.1mm 9.00 228.6mm Mtg. & Term. Screw #10 #10 1/4 1/4 1/4 1/4 1/4 1/4 Wgt 12 lbs 5.44 kg 18 lbs 8.16 kg 33 lbs 14.97 kg 56 lbs 25.40 kg 70 lbs 31.75 kg 89 lbs 40.37 kg 105 lbs 47.63 kg 150 lbs 68.04 kg *Maximum 0.6 (1.6mm) .12 (3.2mm) If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 29 Step Down Auto Transformers Chassis Mount SM Available with Receptical and Line Cord or Leads Signal's auto transformers provide the user the capability of adapting voltages for worldwide applications. General Specifications Power - 100 VA to 2000 VA Voltage - EB version (230V to 115V - 50/60 Hz) OF version (230V to 115V or 115V to 230V - 50/60 Hz) Connections - EB version (receptacle and 2-prong line cord) OF version (8 inch long leads) Insulation - Class A insulation (105C) EB Version OF Version Part. No. VA (Size) 110 100 112 120 115 150 120 200 125 250 130 300 150 500 175 750 1100 1000 1150 1500 1200 2000 Part. No. VA (Size) 110-OF 100 112-OF 120 115-OF 150 120-OF 200 125-OF 250 130-OF 300 150-OF 500 175-OF 750 1100-OF 1000 1150-OF 1500 1200-OF 2000 Width Depth Height Mtg. Centers Wgt 1.87 47.6mm 2.87 73.0mm 2.87 73.0mm 2.87 73.0mm 2.87 73.0mm 3.25 82.6mm 3.25 82.6mm 3.25 82.6mm 4.50 114.3mm 4.50 114.3mm 4.50 114.3 mm 2.37 60.3mm 2.12 54.0mm 3.37 85.7mm 3.50 88.9mm 3.87 98.4mm 3.87 98.4mm 4.87 123.8mm 5.87 149.2mm 5.12 130.2mm 6.12 155.6mm 7.12 181.0mm 2.50 63.5mm 3.50 88.9mm 3.50 88.9mm 3.50 88.9mm 3.50 88.9mm 3.87 98.4mm 3.87 98.4mm 3.87 98.4mm 5.50 139.7mm 5.50 139.7mm 5.50 139.7mm 1.50 x 1.68 38.1 x 42.8mm 2.25 x 1.75 57.2 x 44.5mm 2.25 x 2.00 57.2 x 50.8mm 2.25 x 2.12 57.2 x 54.0mm 2.25 x 2.50 57.2 x 63.5mm 2.50 x 2.43 63.5 x 61.9mm 2.50 x 3.43 63.5 x 87.3mm 2.50 x 4.43 63.5 x 112.7mm 3.50 x 3.50 88.9 x 88.9mm 3.50 x 4.50 88.9 x 114.3mm 3.50 x 5.50 88.9 x 139.7mm 1.5 lbs 0.68 kg 3.0 lbs 1.36 kg 3.5 lbs 1.59 kg 4.0 lbs 1.81 kg 4.8 lbs 2.18 kg 5.5 lbs 2.49 kg 8 lbs 3.63 kg 11 lbs 5.00 kg 14 lbs 6.35 kg 20 lbs 9.07 kg 26 lbs 11.79 kg Width Depth Height Mtg. Centers Wgt 2.25 57.2mm 3.37 85.7mm 3.37 85.7mm 3.37 85.7mm 3.37 85.7mm 3.75 95.3mm 3.75 95.3mm 3.75 95.3mm 5.25 133.4mm 5.25 133.4mm 5.25 133.4mm 2.00 50.8mm 2.50 63.5mm 2.75 69.9mm 2.87 73.0mm 3.25 82.6mm 3.25 82.6mm 4.25 107.9mm 5.25 133.4mm 4.50 114.3mm 5.50 139.7mm 6.50 165.1mm 1.93 49.2mm 2.87 73.0mm 2.87 73.0mm 2.87 73.0mm 2.87 73.0mm 3.12 79.4mm 3.12 79.4mm 3.12 79.4mm 4.37 111.1mm 4.37 111.1mm 4.37 111.1mm 2.81 71.4mm 2.81 x 1.87 71.4 x 47.6mm 2.81 x 2.12 71.4 x 54.0mm 2.81 x 2.25 71.4 x 57.2mm 2.81 x 2.62 71.4 x 66.7mm 3.12 x 2.50 79.4 x 63.5mm 3.12 x 3.50 79.4 x 88.9mm 3.12 x 4.50 79.4 x 114.3mm 4.37 x 3.12 111.1 x 79.4mm 4.37 x 4.12 111.1 x 104.8mm 4.37 x 5.12 111.1 x 130.2mm 1.3 lbs 0.59 kg 2.5 lbs 1.13 kg 3.0 lbs 1.36 kg 3.5 lbs 1.59 kg 4.2 lbs 1.90 kg 5.0 lbs 2.27 kg 8.0 lbs 3.63 kg 11 lbs 5.00 kg 14 lbs 6.35 kg 19 lbs 8.62 kg 25 lbs 11.34 kg If you don't see a specific part that meets your requirement, see page 31 for our custom magnetics design data sheet. Signal Transformer CALL: 516-239-5777 * FAX: (24hrs) 516-239-7208 500 Bayview Avenue, Inwood, New York 11096 30 Custom Magnetics Design Data Sheet Application: Power transformer (50/60/400 Hz) _______________________________________________________ Switching mode power conversion _________________________ (Topology ______________________________) Other ________________________________________________ Frequency: ___________________________________________ Voltage(s): Primary __________________ Name_______________________________ Address _____________________________ Secondary _______________ At current(s) ________________ _____________________________ _______________ ________________ Contact _____________________________ _______________ ________________ Phone ______________________________ _______________ ________________ Fax ________________________________ Above values are: AC___________ DC ___________ Type of Rectification (or Secondary Loading): _________________________________________________________ Duty Cycle (0 to 100%): ___________________________________________________________________________ Dielectric Withstanding Voltage (Isolation Voltage):_____________________________________________________ Other Requirements: _____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ Quote Price & Delivery on Quantity of: ______________________________________________________________ Schematic: Mechanical Requirements: Signal Transformer NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL PERMIT NO. 953 FAR ROCKAWAY, NY FIRST CLASS MAIL POSTAGE WILL BE PAID BY ADDRESSEE SIGNAL TRANSFORMER CO., INC. 500 BAYVIEW AVE. INWOOD, NY 11096-9898 !1109698989! ATT: CUSTOMER SERVICE PLEASE FOLD THIS FLAP FIRST WHEN RETURNING CARD BY MAIL FAX TO 516-239-7208 OR FOLD AND MAIL Custom Magnetics Design Data Sheet Application: Power transformer (50/60/400 Hz) _______________________________________________________ Switching mode power conversion _________________________ (Topology ______________________________) Other ________________________________________________ Frequency: ___________________________________________ Voltage(s): Primary __________________ Name_______________________________ Address _____________________________ Secondary _______________ At current(s) ________________ _____________________________ _______________ ________________ Contact _____________________________ _______________ ________________ Phone ______________________________ _______________ ________________ Fax ________________________________ Above values are: AC___________ DC ___________ Type of Rectification (or Secondary Loading): _________________________________________________________ Duty Cycle (0 to 100%): ___________________________________________________________________________ Dielectric Withstanding Voltage (Isolation Voltage):_____________________________________________________ Other Requirements: _____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ Quote Price & Delivery on Quantity of: ______________________________________________________________ Schematic: Mechanical Requirements: Signal Transformer NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL PERMIT NO. 953 FAR ROCKAWAY, NY FIRST CLASS MAIL POSTAGE WILL BE PAID BY ADDRESSEE SIGNAL TRANSFORMER CO., INC. 500 BAYVIEW AVE. INWOOD, NY 11096-9898 !1109698989! ATT: CUSTOMER SERVICE PLEASE FOLD THIS FLAP FIRST WHEN RETURNING CARD BY MAIL FAX TO 516-239-7208 OR FOLD AND MAIL How to specify power transformer & filter ratings The purpose of this section is to provide a practical guide for the selection of a power supply transformer and filter components. A number of basic assumptions are made to avoid an academic discussion of unnecessary material. For those interested in a rigorous theoretical analysis, there are a number of fine references available. Additionally, circuit analysis using appropriate analysis software (SPICE or its equivalent) is recommended in the rare circumstances where a better understanding of a particular situation is needed, or when it becomes necessary to optimize some aspect of the design. Computer analysis is particularly useful in understanding areas that are difficult to approach using traditional circuit analysis methods, areas such as capacitor RMS ripple current. One of the more esoteric problems encountered by the circuit designer is the selection of power transformer ratings for a particular DC power supply. The designer is immediately confronted with a number of rectifier circuits and filter configurations. For the sake of simplicity, we will make some assumptions which should be valid for 99% of the average designer's applications and present some useful rules of thumb appropriate for conservative design. Filters We will immediately discard the consideration of choke input filters and confine our choice to capacitor input filters because of the following: 1. It is desirable to eliminate the weight and cost of chokes. 2. It can be assumed that if a regulator is used it will provide sufficient extra ripple reduction so that an L-C section is not required. In addition, the regulator will compensate for the poor output voltage regulation with load, inherent in capacitor input systems. The remaining disadvantages of the capacitive input filter system are caused by the discontinuous secondary current flow (high peak-to-average ratio of forward diode current). Current is drawn in short, high amplitude pulses to replace the charge of the filter capacitor which discharges into the load during diode off time. This results in higher effective RMS values of transformer secondary current. However, the transformer average VA rating is the same as the choke input filter because the higher DC output voltage obtained at the capacitor compensates for this effect. In addition, except perhaps for supplies handling very high currents, average semiconductor diodes will meet most of the peak or surge current requirements of capacitive filters. 4. Dual Complementary Supply -- "Full-Wave Center-Tap" (four diodes) The only advantages of the half-wave rectifier are its simplicity and the savings in cost of one diode. Its disadvantages are many: 1. Extremely high current spikes are drawn during the capacitor charging interval (only one current surge per cycle). This current is limited only by the effective transformer and rectifier series impedance, but it must not be too high or it will result in rectifier damage. This short once-per-cycle current spike also results in very high secondary RMS currents. 2. The unidirectional DC current in the transformer secondary biases the transformer core with a component of DC flux density. As a result, more "iron" is needed to avoid core saturation. About the only time it would pay to consider using the half-wave rectifier is for very low DC power levels of about 1 2 watt or less. At these levels a power transformer cannot be reduced very much in size (at reasonable cost) and a small filter capacitor will be large enough for adequate DC smoothing. The remaining single-phase rectifier circuits are of the "full-wave" type. Secondary current surges occur twice per cycle so that they are of smaller magnitude and the fundamental ripple frequency is double the supply frequency (i.e., 120 Hz rather than the 60 Hz of a half-wave system). All full-wave rectifiers also have the same basic rectified waveform applied to the filter capacitor. Other Factors * Full-Wave Center-Tap Uses 12 of secondary winding at a time Requires center-tap Uses 2 diodes * Full-Wave Bridge Uses full secondary winding continuously No center-tap required Uses 4 diodes As can be seen above, the choice between FWCT and Bridge configurations is a tradeoff. The bridge rectifier has the best transformer utilization but requires the use of 4 diodes. The extra diodes result in twice the diode voltage drop of a FWCT circuit so that the FWCT is usually preferable in low voltage supplies. Rectifier Circuit The remaining choice is that of a rectifier circuit configuration. The most common single phase circuits are: 1. Half-Wave (single diode) 2. Full-Wave Center-Tapped (two diodes) 3. Full-Wave Bridge (four diodes) 35 How to specify power transformer & filter ratings The "dual complementary rectifier circuit" is the combination of two FWCT circuits and is a very efficient way of obtaining two identical outputs of reversed polarity sharing a common ground. It is also called a "centertapped bridge rectifier." The diagram below represents a full-wave center-tapped rectifier using a capacitive filter and is the most common selection for moderate power, regulated DC supplies. The following assumptions can safely be made: 1. VREG is approximately 3 volts DC or greater. 2. VRECT is about 1.25 volts DC. 3. VRIPPLE is about 10% VDC peak. The following formula may be used for determining the transformer secondary voltage: Required RMS Secondary Current Rating 0.7 x DC Current Rectifier Type Filter Type* Full-Wave Center-Tap Choke Input Full-Wave Center-Tap Capacitor Input 1.2 x DC Current Full-Wave Bridge Choke Input DC Current Full-Wave Bridge Capacitor Input 1.8 x DC Current *Even though we have dropped choke input filters from this discussion, they are included for reference. For instance, in our particular example (5 V, 2A DC supply) the transformer RMS current would be: for FWCT 1.2 x 2 = 2.4 A for bridge 1.8 x 2 = 3.6 A The total transformer specification would then be: Circuit Secondary Rating Possible "Signal" Parts FWCT 18.5 CT @ 2.4A RMS = 43.2 VA 241-7-20, 36-1 bridge 10.5 @ 3.6A RMS = 36 VA ST-7-10, 241-6 or 7-10, 10-4 Dual Complementary Supply One more common example will be given, i.e., a dual complementary supply for 15 V @ 100 mA DC. VOUT = 15 VRECT = 1.25 VREG = 3 VRIPPLE = 0.75 (1.5 V p-p) VAC = (15 + 3 + 1.25 + 0.75) x 115 x 1 = 19V 0.9 95 M2 1AC = 1.8 x 100 mA = 180 mA RMS The transformer secondary rating is 38 V CT @ 180 mA RMS. Possible Signal parts would be ST-4-36, PC-34-300, PC-40-250. A precautionary calculation remains to be made. That is, the increase in voltage at the filter capacitor (into the regulator) caused by a high line condition. If we assume our highest line voltage to be 130 V AC then the transformer output (compared to low line) would rise by the ratio 130/95. In the 5V supply, for instance, the following would happen: VAC = 130 x 9.27 = 12.7V 95 In the dual complementary +15 V supply: VAC = 130 x 19 = 26V 95 The increase in output must be absorbed by the regulator, which results in higher regulator power dissipation. The illustrated values are safe for the typical IC regulator but should be checked in any specific application. VNOM is VLOWLINE the ratio of the nominal AC line voltage to the required low line conditions. A sample illustration of the above will be shown for a supply requiring an output of 5V DC at 2A DC to operate down to an input voltage of 95V RMS. VOUT = 5V VREG = 3V VRECT = 1.25V VRIPPLE = 0.5 (1V p-p) VAC = 9.75 x 115 x 1 = 9.27 VAC 0.9 95 M2 Therefore, the transformer secondary voltage can be specified as about 18 V CT. For a bridge rectifier of the same output requirements, the only change is that: VRECT = 2 x 1.25 = 2.5V As a result VAC will be reformulated as: VAC = 11 x 115 x 1 = 10.46 VAC 0.9 95 M2 so that the transformer secondary voltage now becomes about 10.5V. Transformer Secondary Current The remaining step is to determine the transformer RMS secondary circuit. This can be accurately determined only by complex analysis. However, for practical engineering purposes the chart below may be used. 36 How to specify power transformer & filter ratings ADDITIONAL FACTORS TO BE CONSIDERED IN TRANSFORMER SELECTION Load Regulation Temperature Rise It has been assumed in the previous discussion of the In power transformers over 25VA, temperature rise change in transformer secondary voltage with line voltage that becomes a factor. The transformer may be constructed no change has been occurring in load current. Therefore, the with materials capable of withstanding higher temperatures transformers would seem to be ideal and the transformer and be a perfectly valid design. However, the extra power secondary voltage (VAC) will always be the same. Actually, dissipated may cause heating of nearby components. This all the voltages calculated are assumed to be full load. added power loss increases the total power dissipated in the Since transformers are not ideal and have an internal circuit area. The problem is not the internal temperature of impedance or "regulation" characteristic, variations in load the transformer, but the actual increase in watts lost. current may cause a problem. If the load should be "light" at Shielding "high line," then there will be an additional rise in secondary Certain AC power line noise and transients will be fed voltage, beyond that due to the rising line voltage, caused through to the transformer secondary because of the by the decreasing voltage drop in the transformer windings. capacitance between windings. This is a problem which is Most smaller VA transformers (<10VA) have a load very difficult to analyze. Whether or not it is a problem in a regulation of 20% or higher. This means that the transparticular applicaton can be best determined empirically. former no-load voltage will be 20% or more higher than If such feedthrough is a problem, the most common first rated full-load voltage. This must then be taken into step is to use an electro-static shield between windings. account in the calculation of maximum VAC (and DC This effectively reduces the inter-winding capacitance. voltage into regulator) with low-load currents. An equal and sometimes superior approach is to choose Due to the inherent design characteristics of transtransformers with non-concentric windings, i.e., with priformers, "regulation" will vary inversely with size (or VA mary and secondary wound side-by-side rather than one rating). In larger transformers size is determined primarily over the other. Both result in at least order of magnitude by the heat generated by internal losses. In smaller transreductions in capacitance. The "non-concentric" approach, formers (low VA rating) size is determined by the maximum however, gives superior reductions. It also results in higher permissible no-load to full-load regulation. Even though this insulation resistance and makes it simpler to obtain higher is an important design limitation, most transformer manuinsulation test voltages. Certain types of feedthrough cannot be much affected facturers do not publish load regulation data. The chart by the transformer design and other approaches such below tabulates load regulation for Signal standard as line filters or "MOVs" or ZNR's (transient surge transformers. suppressors) may have to be considered. It is possible to estimate the output voltage at intermediate loads since load regulation varies in an almost linear manner. Summary For example, the 241-8-16 has a full-load rating of 16 V @ This has been an attempt to provide a simple, practical 6.25 A and a regulation of 10%. Its no-load output would be method of determining transformer ratings. Certain basic 10% more than 16 or 17.6 V. At half-load (3.12 A) its output assumptions have been made and this section is not meant would be 5% more than 16 or 16.8 V. Similar estimates can as a rigorous academic analysis. However, such material is be made for any % load. readily available in the literature (see below). This, we feel, Another factor to bear in mind is that it is possible to may help bridge the gap for the working designer. safely exceed the VA rating References of many small power transSignal Transformer - % Load Regulation For more detailed theoretical analysis formers. If the added of Standard Transformers the following are recommended: regulation (drop in output Family or Series Size or VA Rating Approx. % 1. Reuben Lee, Electronic Regulation voltage) is acceptable, an 2.5, 5.0, 10VA 30 Transformers & Circuits, 1947, "overload" may be per14A & 14A-R 20, 30 & 56 VA 20 John Wiley & Sons missible because the design IF (International 2VA-18VA 21-27 2. EE Staff - MIT, Magnetic Circuits & is regulation-limited rather Flathead) 24VA & 30VA 20 Transformers, 1943, 25VA 20 than heat rise-limited. If such A41 43VA 15 John Wiley & Sons a choice is being considered, 80 & 130VA 10 3. O.H. Schade, Proc. IRE, vol 31, the decision should be 175VA 8 p. 356, 1943 MPI 200VA-900VA 4-10 checked with our Design HPI 2KVA-3.5KVA 2-4 Engineering department. M4L 3, 6, 10 8 ST & DST SPLIT TRAN PC & DPC LP (Flathead) 241 & DP241 RECTIFIER TYPES ST-2 ST, 3, 4, 5, 6 & 7 ALL 2.5 & 6VA 12, 24 & 48VA 2.4 TO 12VA SIZES 3, 4, 5 30 & 56VA SIZES 6 & 7 100VA SIZE 8 1 TO 100VA 100 TO 350VA 500VA OR OVER 30 20 20 30 20 20 15 10 10 8 5% OR LESS % load regulation is defined as: Vnl - Vfl x 100 % Vfl or the % rise in output voltage at no load as compared to full load. 37 How to specify power transformer & filter ratings COMMENTS ON CAPACITOR & DIODE SELECTION Manufacturer's rating on a 4,600 F/20V capacitor @ TA = 65C is 3.1 A RMS. Dividing by 2.5 to convert from RMS ripple current to output current yields a maximum DC load current of 1.24 amps. Obviously either a large capacitor is required or ambient temperature must be reduced. As a final note, be sure to check whether the data sheet ratings are for still or moving air. Computer grade capacitors are often rated only for moving air. Other types may be rated for still air and are, therefore, actually more conservatively rated. Remember that capacitors are the number one cause of power supply failure. Don't let your supplies dominate the statistics column! Capacitor Selection For low current supplies (IOUT