Microsemi Proprietary and Confidential DS0106 Datasheet Revision 6.0 xi
VREF = 1.0 V Applicable to Pro I/Os for A3PE600L and A3PE3000L Only . . . . . . . . . . . . . . . . . . 89
Table 138 Minimum and Maximum DC Input and Output Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Table 139 AC Waveforms, Measuring Points, and Capacitive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Table 140 2.5 V GTL+: Military-Case Conditions: TJ = 125 °C, Worst-Case VCC = 1.14 V,
Worst-Case VCCI = 2.3 V, VREF = 1.0 V Applicable to Pro I/Os for A3PE600L and
A3PE3000L Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Table 141 2.5 V GTL+: Military-Case Conditions: TJ = 125 °C, VCC = 1.425 V,
Worst-Case VCCI = 2.3 V, VREF = 1.0 V Applicable to Pro I/Os for A3PE600L and
A3PE3000L Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Table 142 Minimum and Maximum DC Input and Output Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Table 143 AC Waveforms, Measuring Points, and Capacitive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Table 144 HSTL Class I: Military-Case Conditions: TJ = 125 °C, Worst-Case VCC = 1.14 V,
Worst-Case VCCI = 1.4 V, VREF = 0.75 V Applicable to Pro I/Os for A3PE600L and A3PE3000L
Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Table 145 HSTL Class I: Military-Case Conditions: TJ = 125 °C, VCC = 1.425 V,
Worst-Case VCCI = 1.4 V, VREF = 0.75 V Applicable to Pro I/Os for A3PE600L and A3PE3000L
Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Table 146 Minimum and Maximum DC Input and Output Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Table 147 AC Waveforms, Measuring Points, and Capacitive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Table 148 HSTL Class II Military-Case Conditions: TJ = 125 °C, Worst-Case VCC = 1.14 V,
Worst-Case VCCI = 1.4 V, VREF = 0.75 V Applicable to Pro I/Os for A3PE600L and A3PE3000L
Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Table 149 HSTL Class II Military-Case Conditions: TJ = 125 °C, VCC = 1.425 V, Worst-Case VCCI = 1.4 V,
VREF = 0.75 V Applicable to Pro I/Os for A3PE600L and A3PE3000L Only . . . . . . . . . . . . . . . . . 93
Table 150 Minimum and Maximum DC Input and Output Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Table 151 AC Waveforms, Measuring Points, and Capacitive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Table 152 SSTL2 Class I: Military-Case Conditions: TJ = 125 °C, Worst-Case VCC = 1.14 V,
Worst-Case VCCI = 2.3 V, VREF = 1.25 V Applicable to Pro I/Os for A3PE600L and A3PE3000L
Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Table 153 SSTL2 Class I Military-Case Conditions: TJ = 125 °C, VCC = 1.425 V, Worst-Case VCCI = 2.3 V,
VREF = 1.25 V Applicable to Pro I/Os for A3PE600L and A3PE3000L Only . . . . . . . . . . . . . . . . . 94
Table 154 Minimum and Maximum DC Input and Output Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Table 155 AC Waveforms, Measuring Points, and Capacitive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Table 156 SSTL2 Class II Military-Case Conditions: TJ = 125 °C, Worst-Case VCC = 1.14 V,
Worst-Case VCCI = 2.3 V, VREF = 1.25 V Applicable to Pro I/Os for A3PE600L and A3PE3000L
Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Table 157 SSTL2 Class II Military-Case Conditions: TJ = 125 °C, VCC = 1.425 V,
Worst-Case VCCI = 2.3 V, VREF = 1.25 V Applicable to Pro I/Os for A3PE600L and A3PE3000L
Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Table 158 Minimum and Maximum DC Input and Output Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Table 159 AC Waveforms, Measuring Points, and Capacitive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Table 160 SSTL3 Class I: Military-Case Conditions: TJ = 125°C, Worst-Case VCC = 1.14 V,
Worst-Case VCCI = 3.0 V, VREF = 1.5 V Applicable to Pro I/Os for A3PE600L and
A3PE3000L Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Table 161 SSTL3 Class I: Military-Case Conditions: TJ = 125 °C, VCC = 1.425 V, Worst-Case VCCI = 3.0 V,
VREF = 1.5 V Applicable to Pro I/Os for A3PE600L and A3PE3000L Only . . . . . . . . . . . . . . . . . . 96
Table 162 Minimum and Maximum DC Input and Output Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Table 163 AC Waveforms, Measuring Points, and Capacitive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Table 164 SSTL3 Class II: Military-Case Conditions: TJ = 125 °C, Worst-Case VCC = 1.14 V,
Worst-Case VCCI = 3.0 V, VREF = 1.5 V Applicable to Pro I/Os for A3PE600L and
A3PE3000L Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Table 165 SSTL3 Class II: Military-Case Conditions: TJ = 125 °C, VCC = 1.425 V,
Worst-Case VCCI = 3.0 V, VREF = 1.5 V Applicable to Pro I/Os for A3PE600L and
A3PE3000L Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Table 166 Minimum and Maximum DC Input and Output Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Table 167 AC Waveforms, Measuring Points, and Capacitive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Table 168 LVDS: Military-Case Conditions: TJ = 125 °C, Worst-Case VCC = 1.14 V, Worst-Case
VCCI = 2.3 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Table 169 LVDS: Military-Case Conditions: TJ = 125 °C, VCC = 1.425 V, Worst-Case VCCI = 2.3 V . . . . . . 99