GaAs Flip Chip Schottky Barrier Diodes MA4E1317, MA4E1318, MA4E1319-1, MA4E1319-2
M/A-COM, Inc.
North America: Tel. (800) 366-2266 ■Asia/Pacific: Tel. +81 (03) 3226-1671 ■Europe: Tel. +44 (1344) 869 595
Fax (800) 618-8883 Fax +81 (03) 3226-1451 Fax +44 (1344) 300 020
3
Specifications Subject to Change Without Notice.
V2.00
100.00
10.00
1.00
0.10
0.01
0.000.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00
FORWARD CURRENT (mA)
FORWARD VOLTAGE (V)
FORWARD CURRENT VS FORWARD
VOLTAGE AND TEMPERATURE
Handling Procedures
The following precautions should be observed to avoid
damaging these chips:
Cleanliness: These chips should be handled in a clean
environment. Do not attempt to clean die after
installation.
Static Sensitivity: Schottky barrier diodes are ESD
sensitive and can be damaged by static electricity.
Proper ESD techniques should be used when handling
these devices.
General Handling: The protective polymer coating on
the active areas of these die provides scratch protection,
particularly for the metal airbridge which contacts the
anode. Die can be handled with tweezers or vacuum
pickups and are suitable for use with automatic
pick-and-place equipment.
Mounting Techniques
These chips were designed to be inserted onto hard or
soft substrates with the junction side down. They can be
mounted with conductive epoxy or with a low tempera-
ture solder preform. The die can also be assembled with
the junction side up, and wire or ribbon bonds made to
the pads.
Solder Die Attach: Solder which does not scavange
gold, such as Indalloy # 2, is recommended. Sn-Pb based
solders are not recommended due to solder
embrittlement. Do not expose die to a temperature
greater than 235°C, or greater than 200°C for longer than
10 seconds. No more than three seconds of scrubbing
should be required for attachment.
Epoxy Die Attach: Assembly can be preheated to 125
to 150°C. Use a minimum amount of epoxy. Cure epoxy
as per manufacturer’s schedule. For extended cure times,
temperatures should be kept below 200°C.
Absolute Maximum Ratings1
Parameter Absolute Maximum
Operating Temperature -65°C to +125°C
Storage Temperature -65°C to +150°C
Incident LO Power +20 dBm
Incident RF Power +20 dBm
Mounting Temperature +235°C for 10 seconds
1. Exceeding these limits may cause permanent damage.
125°C 25°C -50°C