Electrical data
Primary nominal Primary current, Type RoHS since
current rms measuring range date code
IPN (mA) IPM (mA)
100 ± 200 CT 0.1-P 46129
200 ± 400 CT 0.2-P 46054
400 ± 800 CT 0.4-P 46234
VCSupply voltage (± 5 %) ± 15 V
I CCurrent consumption ± 45 mA
RIS Isolation resistance @ 500 VDC > 500 M
VOUT Output voltage (Analog) @ ± IPN, RL= 10k, TA=25°C ± 5 V
ROUT Output internal resistance < 51
RLLoad resistance 10 k
CLCapacitive loading 5nF
Accuracy-Dynamic performance data
XAccuracy (excluding offset) @ IPN, TA = 25°C, RL = 10k< ± 1 %of IPN
εLLinearity error (0 .. ± IPN)< ± 0.5 %of IPN
TCVOUT Temperature coefficient of VOUT (of reading) < ± 0.05 %/K
VOE Electrical offset voltage @ IP = 0, TA = 25°C < ± 100 mV
VOH Hysteresis offset voltage
@ IP = 0; after an excursion of 1 x IPN < ± 2 mV
@ IP = 0; after an excursion of 100 x IPN < ± 20 mV
TCVOE Temperature coefficient of VOE @ -20..+85°C CT 0.1-P < ± 8 mV/K
CT 0.2-P < ± 4 mV/K
CT 0.4-P < ± 2 mV/K
t rResponse time to 80% of IPN step 20 ms
90% of IPN step 60 ms
BW Frequency bandwidth (- 3 dB) CT 0.1-P DC 40..7000Hz
CT 0.2-P DC 40..11000Hz
CT 0.4-P DC 40..18000Hz
General data
TAAmbient operating temperature - 20 .. + 85 °C
TSAmbient storage temperature - 25 .. + 85 °C
dCp Creepage distance > 5.5 mm
dCl Clearance distance > 5.5 mm
CTI Comparative tracking index (Group IIIa) > 220
mMass 25 g
Standards EN 50178: 1997
Current Transducers CT 0.1 .. 0.4-P
For the electronic measurement of small currents: AC,DC, mixed,
with a galvanic isolation between the primary circuit and the
secondary circuit.
IPN = ± 100..400 mA
VOUT = ± 5 V
Features
DC & AC earth leakage current
transducer using a flux-gate
principle
PCB mounting
±15V power supply
±5V output @ IPN
Isolated plastic case recognized
according to UL94-V0.
Advantages
Small size
Bandwidth :
DC and 40 up to 7..18 kHz
Response time better than 60 ms
Cost effective, compact
alternative to classical RCDs
(Residual Current Device)
Applications
Earth leakage detection in
transformerless solar inverters
1st human contact protection of
PV arrays
Failure detection in power sources
Symmetrical fault detection
(e.g. after motor inverter)
Current leakage detection in
stacked DC sources
Single phase or three phase
differential current measurement up
to ±30A per wire (DC or AC)
Application domain
Industrial
copyright protected
080909/14 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
Notes : Performance data are given for steady phase of the transducer.
Transitory period after power on lasts typically less than 2 min.
Please refer to characterization report for details.
Please don't put the high voltage between the secondary pins and fixing
pins. If it must be so, don't exceed the 2.5 kV between these pins with the
maximum isolation distance.
Current Transducer CT 0.1 .. 0.4-P
Isolation characteristics
VbRated isolation voltage rms 150 V rms
with IEC 61010-1 standard and following conditions
-Single insulation
-Over voltage category III
-Pollution degree 2
-Heterogeneous field
VbRated isolation voltage rms 250 V rms
with EN 50178 standard and following conditions
-Reinforced insulation
-Over voltage category III
-Pollution degree 2
-Heterogeneous field
VdRms voltage for AC isolation test, 50 Hz, 1 min 2.5 kV
VePartial discharge extinction voltage rms @ 10pC > 1.2 kV
VwImpulse withstand voltage 1.2/50µs6 kV
If insulated cable is used for the primary circuit, the
voltage category could be improved with the following table :
Cable insulation (primary) Category
HAR 03 300V CAT III
HAR 05 400V CAT III
HAR 07 500V CAT III
080909/14 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 2/3
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer's
operating instructions.
Caution! Risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
17.80
30
30
12.6
0.50+/-0.3
5+/-2
11
20
4-0.7+/-0.32-2+/-0.3(NC)
20.3
4.3
10.5
+Vc c
-Vc c
GN D
M
Vo u t
I
Dimensions CT 0.1 .. 0.4-P (in mm. 1 mm = 0.0394 inch)
080909/14 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 3/3
Mechanical characteristics
General tolerance ± 1 mm
(Unless otherwise specified in the above drawings.)
Aperture for primary conductor Ø11 mm
Connection of secondary 4 pins 0.7 x 0.7 mm2
Recommended PCB hole 1.2 mm
PCB fixation 2 pins Ø2 mm
Recommended PCB hole 2.2 mm
Remarks
VOUT is positive when IP flows in the direction of the arrow.
This transducer induces into the primary circuit a square
wave of 500Hz. This voltage can induce an AC current in the
primary if the primary impedance is low.
Primary impedance10 CT 0.1-P CT 0.2-P CT 0.4-P
VOUT by induced current ±0.8% ±0.5% ±0.3% of IPN
Temperature of the primary conductor should not exceed
100°C.
+ Vcc
M
GND
- Vcc
Ip flux-gate
DC
transformer
AC