MODEL TL-2450 TECHNICAL DATA (Typical values @+25C for batteries stored for one year or less) Nominal capacity @ 0.5 mA, to 2V Rated voltage Maximum recommended continuous current Maximum pulse current capability Weight Volume Operating temperature range Li metal content U.L. Component Recognition MH 12193 Volts 0.55 Ah 3.6 V 5 mA 10 mA 8.8g (0.310 oz) 2.60 cc -55C to +85C approx. 0.2 g DISCHARGE CHARACTERISTICS@ + 25C 4.0 3.5 3.0 2.5 2.0 1.8 K ~2 mA (0.51 Ah) 1.5 6.8 K ~0.5 mA (0.55 Ah) 11 K ~300 A (0.55 Ah) 110 K ~30 A (0.5 Ah) 360 K 680 K ~10 A ~5 A (0.45Ah) (0.42 Ah) ADDITIONAL INFORMATION SUFFIX- /P TIN PLATED NICKEL PINS CATALOGUE NO.: 1.0 1 Volts 3.7 10 100 1000 10000 VOLTAGE VS. TEMPERATURE 15-2450-41020 100000 Hours CAPACITY VS. CURRENT Ah 0.55 3.6 3.5 30 A 3.4 3.3 3.2 3.1 50C 0.50 5 A 0.45 0.1 mA 0.40 0.5 mA 0.35 25C 80C 0.30 3.0 0C 0.25 2.9 2.8 0.20 2 mA 2.7 -30C 0.15 -50 -30 -10 10 30 50 70 90 C 0.01 0.1 1 mA iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. Rev. B 02/11 ECN 1502262 TL-2450 CELL FEATURES 3.6 V Primary lithium-thionyl chloride (Li-SOCl2) Fast voltage recovery after long term storage and/or usage High energy density High and stable operating voltage Low self discharge rate 10 years shelf life Wafer construction Hermetic glass-to-metal-sealing Non-flammable electrolyte Non-restricted for transportation Volts 3.5 MAIN APPLICATIONS VOLTAGE RESPONSE AFTER STORAGE After 1 year After 2 years 3.4 After 5 years 3.3 After 10 years Utility meters (elect., water & gas) Automatic meter reading RF systems Sensors & monitoring systems Tracking systems Wireless security systems Automotive electronics Industrial electronics Ultra Low Power (ULP) 3.2 STORAGE CONDITIONS 3.1 3.0 2.9 Pulse applied: 5 mA for 1 sec Storage: RT Background current: None 2.8 Cells should be stored in a clean & dry (less than 30 % RH) area 2.7 2.6 0 200 400 600 800 VOLTAGE RESPONSE Volts 1000 For updated information please visit our website www.tadiranbat.com 1200 msec VOLTAGE RESPONSE Volts After 1 year 3.4 After 2 years After 5 years 3.4 After 1 year After 7 years After 5 years After 2 years After 10 years 3.3 3.2 3.3 3.2 Pulse applied: 5 mA for 100 msec Temperature: RT Background current: 2 A 3.1 Pulse applied: 5 mA for 100 msec Temperature: RT Background current: 4 A 3.1 0 20 40 60 80 100 120 msec 0 20 40 60 80 100 120 msec iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. Rev. B 02/11 ECN 1502262