T-100 (3 mm)
SOLID STATE LAMPS
.047 (1.2)
.032 (.08) .189 (4.8)
.165 (4.2)
.059 (1.5)
.035 (0.9) 1.040 (26.4)
MIN
(ANODE)
.040 (1.00)
MIN
.100 (2.54)
.122 (3.1)
.106 (2.7)
.137 (3.48)
.113 (2.88) DIA
.020 (.51)
.016 (.41) 2X
.018 (.46)
.012 (.30) 2X
PACKAGE DIMENSIONS
PURE GREEN HLMP-K600 TINTED
PURE GREEN HLMP-K640 CLEAR
SOFT ORANGE HLMP-K400 TINTED
SOFT ORANGE HLMP-K401 TINTED
SOFT ORANGE HLMP-K402 TINTED
DESCRIPTION
These T-100 LEDs are widely used as general
purpose indicators. The pure green lamps is
made with a GaP LED on a GaP substrate. The
soft orange is made with a GaAsP LED on a GaP substrate. They
are encapsulated in epoxy packages and are designed to provide
superior light output and a wide viewing angle.
FEATURES
• Popular T-100 package
• Low drive current
• Solid state reliability
• Wide viewing angle
• Choice of pure green or soft orange colors
Parameter GREEN ORANGE UNITS
Power Dissipation 110 110 mW
Forward Current 40 40 mA
Peak Forward Current (f=1kHz, DF=10%) 200 200 mA
Lead Soldering Time at 260° C 5 5 sec
Operating Temperature -40 to +100 -40 to +100 °C
Storage Temperature -40 to +100 -40 to +100 °C
ABSOLUTE MAXIMUM RATING (TA=25°C)
NOTES:
1. ALL DIMENSIONS ARE IN INCHES (mm).
2. LEAD SPACING IS MEASURED WHERE THE LEADS
EMERGE FROM THE PACKAGE.
3. PROTRUDED RESIN UNDER THE FLANGE IS 1.5 mm (.059)
MAX.
2001 Fairchild Semiconductor Corporation
DS300014 2/27/01 1 OF 4 www.fairchildsemi.com
Part Number HLMP-K600 HLMP-K640* HLMP-K400 HLMP-K401 HLMP-K402 Condition
Luminous Intensity (mcd) IF= 10mA
Minimum 1.0 4.0 1.0 2.0 3.0
Typical 4.5 15.0 4.0 5.0 7.0
Forward Voltage (V) IF= 10mA
Maximum 2.7 3.0 2.4 2.4 2.4
Typical 2.1 2.2 1.9 1.9 1,9
Peak Wavelength (nm) 555 555 612 612 612 IF= 10mA
Spectral Line Half Width (nm) 24 24 40 40 40 IF= 10mA
Reverse Voltage (V) 5 5 5 5 5 IR= 100µA
Viewing Angle (°) 90 45 90 90 90 IF= 10mA
ELECTRICAL / OPTICAL CHARACTERISTICS (TA=25°C)
* HLMP-K640 test condition is IF= 20mA
T-100 (3 mm)
SOLID STATE LAMPS
www.fairchildsemi.com 2 OF 4 2/27/01 DS300014
90
IF - FORWARD CURRENT (mA)
VF - FORWARD VOLTAGE (V)
Fig. 1 Forward Current vs. Forward Voltage
40
50
60
70
80
30
20
10
0
1.0 2.0 3.0 4.0 5.0
IF - DC FORWARD CURRENT (mA)
RELATIVE LUMNOUS INTENSITY
(NORMALIZED AT 20 mA)
Fig. 2 Relative Luminous Intensity vs.
DC Forward Current
2.5
2.0
1.5
1.0
0.5
0.0
0102030
RELATIVE INTENSITY
Fig. 3 Relative Intensity vs. Peak Wavelength
1.0
0.5
0
500 550 600 650 700 750
WAVELENGTH (nm)
GREEN ORANGE
IF - FORWARD CURRENT (mA)
TA - AMBIENT TEMPERATURE (˚C)
Fig. 4 Current Derating Curve
50
40
30
20
10
0
0 20 40 60 80 100
REL. LUMINOUS INTENSITY (%)
Fig. 5A Radiation Diagram
(HLMP-K600, HLMP-K400, HLMP-K401, HLMP-K402)
0 20406080100020406080
100 90˚
80˚
70˚
60˚
50˚
40˚
30˚
20˚
10˚
-10˚
-20˚
-30˚
-40˚
-50˚
-60˚
-70˚
-80˚
-90˚
REL. LUMINOUS INTENSITY (%)
Fig. 5B Radiation Diagram
(HLMP-K640)
0 20406080100020406080
100 90˚
80˚
70˚
60˚
50˚
40˚
30˚
20˚
10˚
-10˚
-20˚
-30˚
-40˚
-50˚
-60˚
-70˚
-80˚
-90˚
TYPICAL PERFORMANCE CURVES (TA=25°C)
T-100 (3 mm)
SOLID STATE LAMPS
DS300014 2/27/01 3 OF 4 www.fairchildsemi.com
DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE
TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT
ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT
DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE
RIGHTS OF OTHERS.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical
implant into the body,or (b) support or sustain life,
and (c) whose failure to perform when properly
used in accordance with instructions for use provided
in labeling, can be reasonably expected to result in a
significant injury of the user.
2. A critical component in any component of a life support
device or system whose failure to perform can be
reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
T-100 (3 mm)
SOLID STATE LAMPS
www.fairchildsemi.com 4 OF 4 2/27/01 DS300014