MITSUMI CMOS Operational Amplifier (Single) MM3002
Recommended Operating Conditions
Measuring Circuit (Except where noted otherwise, Ta=25°C, VDD=3V, VIN=VDD/2, SW1;A)
Electrical Characteristics (Except where noted otherwise, Ta=25°C, VDD=3V, VIN=1.5V)
Item Symbol Ratings Units
Operating temperature TOPR
-
30~+85 °C
Power supply voltage VOPR +2.7~+9 V
Input voltage VI0~VDD V
Item Symbol Measurement conditions
Measurement
Min. Typ. Max. Units
curcuit
Input offset voltage VOS Rs <
= 10kΩ113mV
Input offset voltage VOS/Ta=30°C~+85°C 1 5
µV/
°C
temperature Drift Ta
Input bias current IB25pA
Common - mode
signal rejection ratio CMRR 1 60 70 dB
Power supply voltage
rejection ratio PSRR VDD=3V~5V 1 70 90 dB
Current consumption IDD 3 50 120 240 µA
Input voltage L VIL 4
-
0.1 0 V
Input voltage H VIH 5VDD
V
DD
+0.1
V
Voltage gain AVRL>
= 100kΩ68095 dB
Gain band area GBW AV=0dB 6 800 kHz
Output voltage L VOL 7 0.03 0.05 V
Output voltage H VOH 8 2.95 2.97 V
Output flow current ISO 9 2.5 5 mA
Output inflow current ISI 10 2.5 5 mA
Through rate SR 11 0.6 V/µS
NOTE1 Put capacitors of number µF between VDD
-
VSS when using.
Vo1
-
VIN
VOS=100
100 vi1
CMRR=20log vo1 SW1 ; B vi1=1V(P
-
P)
(5
-
3) 100
PSRR=20log (vo1
-
VIN1)
-
(vo2
-
VIN2) VIN2, VO2 ; VDD=5V
Measuring circuit 1