Instruction Sheet
SDL Flat-Cable Plug Connector
Cable Guide/Adapters 408-6974
(was IS 6974)
LOC B
1
of 2
E
2004 Tyco Electronics Corporation, Harrisburg, PA
All International Rights Reserved
AMP and Tyco are trademarks. *Trademark
Other products, logos, and company names used are the property of their respective owners.
TOOLING ASSISTANCE CENTER 1-800-722-1111
FAX/PRODUCT INFO 1-800-522-6752
For Regional Customer Service, visit our website at
www.tycoelectronics.com
This controlled document is subject to change.
For latest revision, call the FAX/PRODUCT INFO number.
24 SEP 04 Rev A
63394-1 and 63396-1
Gold Contacts
Tabs
Drain Wire
(Each Side)
Foil
4-Position Cable (Typ)
Cable Guide/Adapter
8-Position SDL
Flat-Cable Plug
Assembly (Typ)
Cantilevered
Metal Flaps
PLUG ASSEMBLY POSITION CABLE POSITION CABLE GUIDE/ADAPTER TYPE
X-520423-3 8 520471-1 4 63396-1 Centered
X-520809-3 8 520471-1 4 63396-1 Centered
X-520423-6 16 520475-1 8 63394-1 Centered
NOTE:
“X” denotes 1–through–5, depending upon desired keying.
Figure 1
1. INTRODUCTION
This instruction sheet covers the installation and
application of SDL Flat–Cable Plug Connector Cable
Guide/Adapters 63394–1 and 63396–1. These cable
guide/adapters are used to convert 8– or 16–position
SDL Flat–Cable Plug Connectors for use with a
4–position flat cable.
Dimensions in this instruction sheet are in
millimeters [with inches in brackets]. Figures are
for reference only, and are not drawn to scale.
Reasons for reissue of this instruction sheet are
provided in Section 4, REVISION SUMMARY.
Read these instructions carefully before installing the
adapter.
2. DESCRIPTION
The cable guide/adapter is a formed metal insert
which is positioned within the cable cavity of an 8– or
16–position SDL Flat–Cable Plug Assembly. The
adapter properly orients a four–position flat cable so
that it is centered on four contacts of the 8– or
16–position plug. The adapter provides additional
shielding for the finished plug assembly. Refer to
Figure 1.
3. INSTALLATION
When using an 8– or 16–position SDL Flat–Cable
Plug Assembly with a keying configuration compatible
with your receptacle application, and a four–position
flat cable, see Figure 2. Installation is as follows:
1. Strip the 4–position cable by removing 11.68
+0.25 [.460 +.010] of outer jacket from the cable.
Refer to Figure 1.
2. Grasp the plug connector and hold it with the
gold contacts facing up.
3. Grasp the cable guide/adapter with the tabs UP
and insert it into the plug cavity as shown in
Figure 2. Push the adapter into the cavity until it
latches on the cantilevered metal flaps in the cavity
and the adapter tabs are flush with the cavity
opening.
It is important to have the adapter properly
orientated as shown in Figure 2. Once the
adapter has been inserted, it may not be
removed.
NOTE
NOTE
408-6974
SDL Flat-Cable Plug Connector Cable Guide/Adapters 63394-1 and 63396-1
Rev
A2
of 2
Figure 2
Gold Contacts UP"
Tabs Flush with
Edges of Cavity
Tabs UP"
Proper Orientation of
Guide/Adapter for
Insertion in Plug Cavity
4. Insert the stripped 4–position cable into the plug
cavity created by the guide/adapter until the
conductors are bottomed in the cavity.
5. Examine the mating face of the plug connector
to ensure that the conductors are against the inner
surface of the mating face. Refer to Figure 3.
6. Terminate the plug connector in accordance with
the instructions packaged with the termination
tooling.
For additional information regarding SDL
Flat-Cable Plug Connectors, refer to Application
Specification 114-2086.
Damaged product should not be used. If
damaged product is evident, it should be cut from
the cable and replaced with a new one.
4. REVISION SUMMARY
This paragraph provides revisions and changes made
to this instruction sheet per EC 0990–1267–04 which
include:
S
Updated document to corporate requirements
S
Deleted obsolete information in the table in
Figure 1
Figure 3
Cable Insertion and
Conductor Examination
4-Position Cable Inserted
into Plug Cavity with
Cable Guide/Adapter
Mating Face of
Plug Connector
Conductors Against
Inner Surface
NOTE
CAUTION