ScotchlokTM Terminals W MNG24-0F thru MNG10-10F C Standard Fork, Nylon Insulated with Insulation Grip E L Data Sheet Product Number Wire Range (AWG) Stud Size Thickness Barrel Length Barrel I.D. Maximum Insulation Diameter W C L E MNG24-0F* 26-24 0 0.13 0.12 0.46 0.40 0.020 0.13 0.030 0.093 MNG24-4F* 26-24 4 0.20 0.21 0.61 0.49 0.020 0.14 0.030 0.093 MNG24-6F* 26-24 6 0.25 0.28 0.69 0.56 0.020 0.13 0.030 0.093 MNG18-6F 22-18 6 0.34 0.29 0.89 0.73 0.030 0.25 0.070 0.145 MNG18-8F 22-18 8 0.34 0.29 .089 0.73 0.030 0.25 0.070 0.145 MNG18-10F 22-18 10 0.34 0.29 0.89 0.73 0.030 0.25 0.070 0.145 MNG14-6F 16-14 6 0.34 0.29 0.91 0.75 0.030 0.25 0.090 0.170 MNG14-8F 16-14 8 0.34 0.29 0.91 0.75 0.030 0.25 0.090 0.170 MNG14-10F 16-14 10 0.34 0.29 0.91 0.75 0.030 0.25 0.090 0.170 MNG10-6F 12-10 6 0.38 0.29 1.03 0.84 0.040 0.25 0.135 0.250 MNG10-8F 12-10 8 0.38 0.29 1.03 0.84 0.040 0.25 0.135 0.250 MNG10-10F 12-10 10 0.38 0.29 1.03 0.84 0.040 0.25 0.135 0.250 *Not UL Listed or CSA Certified. Installation Information WARNING LISTED 314R UNDERWRITERS LABORATORIES STANDARD NO. UL 486A 3M FILE NO. E23438 CANADIAN STANDARDS ASSOCIATION STANDARD NO. C22.2 NO. 0. 65 3M FILE NO. LR22190 Max. Operating Temp.: Max. Current: Insulator Material: Terminal Material: Insulation Grip Material: Plating: UL Listed and CSA Certified for use on stranded copper (AWG) wire only. Strip away the end 3/8 inch of wire insulation. Specifications Wire Size: Barrel Seam: Max. Voltage Rating: Turn power off before installing or removing terminal. All electrical work should be done according to appropriate electrical codes. See Table Above Butted with Insulation Grip 600 V Building Wire 1000 V Signs, Fixtures and Luminaires 221F (105C) Same as Wire Nylon ETP Copper Brass Tin Make the crimp in the proper station of a recommended 3M crimp tool: TH-440, TH-450 (scissor style), or TR-482, TR-490 (ratchet style) hand tools. Barrel Crimp (Electrical) Insulation Crimp (Mechanical) Engineering Specification Crimp-type terminals shall, electrically and mechanically, connect to a pre-stripped end of a stranded copper wire: and have a flat tongue portion with a central opening for mounting around a screw or stud. The terminal line shall offer tongue variations in hole (stud) size (6, 8 10, etc.) and configuration (ring, fork, block fork, flanged block fork, locking fork, etc.): and barrel variations in wire (AWG) size (26-24*, 22-18, 16-14, 12-10, etc.) and construction (non-insulated brazed seam, vinyl insulated butted seam, nylon insulated with insulation grip, etc.). The terminal line shall have regulatory agency coverage (UL Listing, CSA Certification). The terminal tongue shall be marked with the wire range and manufacturer's symbol (). The nylon-insulated, standard fork terminal with insulation grip shall be tin-plated, annealed copper, with the tongue having a specified stud slot (size 0 thru 10) and a butted seam barrel with a tin plated brass, funnel entry insulation grip, covered by a molded nylon sleeve, color coded and sized for a specified (AWG) wire range (26-24*, 22-18, 16-14, 12-10). Insulated terminals shall be UL Listed and CSA Certified for 600 Volts maximum building wire: 1000 Volts maximum in signs, fixtures and luminaires and have a maximum operating temperature of 221F (105C). *Not UL Listed or CSA Certified. 3M and Scotchlok are trademarks of 3M IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M's option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 http://www.3M.com/elpd Litho in USA. (c) 3M 2002 78-8126-0492-0-A