Operating Temperature Range: -10°C To +60°C
Max. Recommended Pull Tension: 25 lbs.
Min. Bend Radius (Overall Cable): 1.040 in.
Environmental/Mechanical Characteristics:
Test (Method) TIA 568-D.3 Belden
Thermal Cycling (FOTP-3) n/a -40 to 75°C cycling for 7 days
Temperature Life (FOTP-4) 60°C for 4 days 85°C for 7 days
Humidity (FOTP-5) 90-95% at 40°C for 4 days 95% @ 75°C for 7 days
Durability (FOTP-21) 500 cycles 6 x 200 cycles (3 Elevations)
Cable Retention (FOTP-6) 5.0 kg @ 0 deg. 1.94 kg @90 deg.
Flex (FOTP-1) 0.5 kg @ 90° to -90° for 100 cycles 0.9 kg @ 90° to -90° for 100 cycles
Twist (FOTP-36) 1.5 kg for 10 cycles 1.5 kg for 10 cycles
Overall Length Tolerances:
Range Tolerance Range Tolerance Range Tolerance
Sx & Dx Patchcord Sx & Dx Patchcord MPO Trunk MPO Trunk Multi-Fiber Cable Assembly Multi-Fiber Cable Assembly
0 to 2 meters +0.2 / -0 meter 0 to 2 meters +0.2 / -0 meter 0 to 2 meters +0.2 / -0 meter
2.1 to 5.0 meters +0.3 / -0 meter 2.1 to 5.0 meters +0.3 / -0 meter 2.1 to 5.0 meters +0.3 / -0 meter
5.1 to 40 meters +0.4 / -0 meter 5.1 to 20 meters +0.4 / -0 meter 5.1 to 20 meters +0.4 / -0 meter
Over 40.1 meters + 1.0% / -0% Over 20.1 meters + 1.0% / -0% Over 20.1 meters + 1.3 / -0 meter
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
UL Rating: Riser
Other Standards: FCC Part 68, Subpart F, IEC 60603-7
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
MII Order #39 (China RoHS): EUP 50
Telecommunications Standards: Category 5e - TIA 568.B.2, Category 5 - ISO/IEC 11801:2002 Ed.2
Safety Listing: ACA, Bi-national Standard Listed
Suitability
Suitability - Indoor: Yes
Transmission Characteristics (Connectivity)
Optical Connector Performance:
Description OM1 OM2 OM3 OM4 OS2 / UPC OS2 / APC
Maximum Insertion Loss (dB) 0.5 dB 0.5 dB 0.5 dB 0.15 dB 0.5 dB 0.5 dB
Minimum Reflectance (dB) -20 dB -20 dB -20 dB -20 dB -50 dB - 65 dB
Performance Table 1:
Frequency
(MHz)
Max.
Insertion Loss
TIA* (dB)
Max.
Insertion Loss
Belden (dB)
Min.
PSNEXT
TIA* (dB)
Min
PSNEXT
Belden (dB)
Min.
PSACRF
TIA* (dB)
Min.
PSACRF
Belden (dB)
1.000 2.400 2.000 62.300 65.300 60.800 60.800
4.000 4.900 4.000 53.300 56.300 48.800 48.800
8.000 6.900 5.700 48.800 51.800 42.700 42.700
10.000 7.800 6.400 47.300 50.300 40.800 40.800
16.000 9.900 8.100 44.200 47.300 36.700 36.700
20.000 11.100 9.200 42.800 45.800 34.800 34.800
25.000 12.500 10.300 41.300 44.300 32.800 32.800
31.250 14.100 11.600 39.900 42.900 30.900 30.900
62.500 20.400 16.800 35.400 38.400 24.900 24.900
100.000 26.400 21.700 32.300 35.300 20.800 20.800
160.000 28.200 32.300 16.700
Performance Table - Footnote: 100 Meter Cable Specifications - * TIA-EIA-568-B.2 Category 5e Standard -------- PSACRF is formally
PSELFEXT
Performance Table 2:
Frequency (MHz)
Min.
Return Loss
TIA* (dB)
Min.
Return Loss
Belden (dB)
1.000 20.000 20.000
4.000 23.000 23.000
8.000 24.500 24.500
10.000 25.000 25.000
16.000 25.000 25.000