Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: • 12.04.2004
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition:
Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Photoelectric sensor
emitter
T186EQ
●M12 x 1 connector
●operational voltage 10..0.30 VDC
●degree of protection IP69K
Wiring diagram
Opposed mode sensors consist of a sepa-
rate emitter and receiver. These are instal-
led directly opposite each other so that the
light from the emitter is aimed directly at the
receiver. When an object interrupts or wea-
kens the light beam, the sensor switches.
Opposed mode sensors are the most relia-
ble photoelectric sensors for detection of
opaque targets. An excellent contrast bet-
ween light and dark conditions and an ex-
tremly high excess gain are typical of this
sensing mode, thus allowing operation
over larger distances and under difficult
conditions.
Excess gain curve
Excess gain in relation to the distance
+
BN (1)
BU (3)
100
10
1
0,1 1 10 100 m
Type T186EQ
Ident-No. 3461100
Operating mode Opposed mode (emitter)
Type of light IR
Wave length 950 nm
Max. sensing range [m] 0... 20 m
Operating temperature -40 ...+ 70 °C
Rated operational voltage (DC) UB10... 30 VDC
Rated operational current (DC) Ie≤ 150 mA
No-load current I0≤ 20 mA
Short-circuit protection yes, cyclic
Reverse polarity protection yes
Housing style cylindrical/thread; T18
Dimensions 30 x 30 x 54 mm
Housing material plastic, PBT
Lens Plastic, Lexan
Wiring connector, M12 x 1
Degree of protection IP68 - IP69K
Supply voltage indication LED green
LED GN
LED YE
M18 x 1
30
ø 30
M12 x 1
ø 15 54
24/8