For more detailed information and individual product specification sheets visit www.tamuracorp.com.
Tamura Corporation of America ¥ P.O. Box 892230 ¥ Temecula, CA 92589-2230 ¥ Tel: 951-699-1270 ¥ FAX: 951-676-9482 ¥ sales@tamuracorp.com
www.tamuracorp.com Standard Products Catalog |21
SINGLE OUTPUT MODELS
M O D E L P O W E R - O N E V O LTAGE, CURRENT2,3 C A S E
NO.1T Y P E OUTPUT 1 OUTPUT 2SIZE
Ð5 VOLT S
OLD-5AA V HAA5-1.5/OVP-A 5V,1.5A* -5V,1.5A* AA
OLD-5BBV HBB5-3/OVP-A 5V,3.0A* -5V,3.0A* BB
OLD-5CCV HCC5-6/OVP-A 5V,6.0A -5V,6.0A CC
Ð12 o r 15 VOLT S
OLD-12B HAD12-0.4-A 12V, 0.4A* -12V ,0.4A* B
OLD-15B HAD15-0.4-A 15V, 0.4A* -15V ,0.4A* B
Ð12/15 VOLT S
OLD-12/15AA HAA15-0.8-A 12V , 1.0A -12V,1.0A AA
jumper chg:
15V,0.8A -15V,0.8A
or -5V, 0.4A
OLD-12/15BB HBB15-1.5-A 12V, 1.7A -12V , 1.7A BB
jumper chg:
15V, 1.5A -15V , 1.5A
or -5V, 0.7A
OLD-12/15CC HCC15-3-A 12V, 3.4A -12V , 3.4A CC
jumper chg:
15V, 3.0A -15V , 3.0A
Ð24 o r 18 to 20 VOLT S
OLD-24AA HAA24-0.6-A 24V, 0.6A* -24V ,0.6A* AA
jumper chg:
1820V , 0.4A -1820V , 0.4A
OLD-24BB HBB24-1.2-A 24V,1.2A* -24V ,1.2A* BB
jumper chg:
1820,0.9A -1820V ,0.9A
OLD-24CC HCC24-2.4-A 24V,2.4A -24V,2.4A CC
jumper chg:
1820V ,1.8A -1820V ,1.8A
5 & 12 to 15 VOLT S
OLD-512AA HAA512-A 5V,2.0A* +1215V ,0.5A* AA
OLD-512BB HBB512-A 5V,3.0A +1215V ,1.25A BB
OLD-512CC HCC512-A 5V,6.0A +1215V ,2.5A CC
SINGLE AND MULTIPLE OUTPUT
LINEAR POWER SUPPLIES
File No. E140527 File No. LR69809
File No.s 3206,3208, 3210,
3216, 3218, 3257, 3212,
3214,3257, 3259, 3261
Tamura has set reliability standards through component upgrade design. Critical specs such as temperature,
voltage and current have been derated so that, for example, 105ÁC instead of 85ÁC electrolytic caps are used.
The result is the highest available MTBF as calculated by MIL-HDBK-217D at full load, 120VAC and 25ÁC
.
U
L
5
4
4
f
o
r
M
E
D
I
C
A
L
&
D
E
N
T
A
L
DUAL OUTPUT MODELS
TRIPLE OUTPUT MODELS
MOD EL P OW E R- ON E V O LTAGE CURRENT2,3
C A S E
NO.1TYPE OUTPUT 1 OUTPUT 2 OUTPUT 3 SIZE
5 & Ð12 TO 15 VOLT S
OL T-522AA HT AA-16W -A 5V,2.0A* 1215V ,0.4A* -(1215)V ,0.4A* AA
jumper chg: -5V,0.4A 4
OL T-522F CP131-A 5V,8.0A 12V, 1.7A -12V , 1.7A 131
jumper chg: 15V, 1.5A -15V, 1.5A
-or-
5V, 0.7A
Features
´ MTBF to 460,000 Hrs.
´ UL 1950, UL544, CSA 1402C,
´ VDE 0805, EN60 950.
´ 100/120/220/230/240VAC inputs.
´ Remote Sensing.
´ 2 Y ear Warranty.
´ 5V OVP Built-in.
´ Optional OVP Module.
´ Short Circuit Protection.
´ Overload Protection
´ Burn-in.
´ Voltage Adjust: Ð5% min.
´ Line/Load Reg: Ð0.05% typ.
´ Noise/Ripple: 5.0mVp-p typ.
´ Transient Response: 50 sec
(50% load chg.)
´ Stability: Ð0.3%for 24 hours.
´ 50ÁC Rated Full Load.
´ Temp coef: Ð0.3%/ÁC max.
´ V ibration: MIL-STD-810C.
´ Shock: MIL-STD-810C.
MECHANICAL DIMENSIONS
Note 1: OVP built-in on main 5V output of multiple output
units. Use OVP-1 module (up to 34V combined for
other outputs).
Note 2: Other industry standard output voltages available
on a special order.
Note 3: * indicates remote sense not provided.
Note 4: Indicates OLT-522AA short J1 for -5V.
M O D EL P O W E R - O NE V O LTA G E ,2C A S E
NO. T Y P E C U R R E N T S I Z E
5 VO LT S
OLS-5BV HB5-3/OVP-A 5V, 3.0A B
OLS-5CV HC5-6/OVP-A 5V, 6.0A C
OLS-5NV HN5-9/OVP-A 5V, 9.0A N
OLS-5DV HD5-12/OVP-A 5V, 12.0A D
12 V OLT S
OLS-12B HB12-1.7-A 12V, 1.7A B
OLS-12C HC12-3.4-A 12V, 3.4A C
OLS-12N HN12-5.1-A 12V, 5.1A N
OLS-12D HD12-6.8-A 12V, 6.8A D
15 V OLT S
OLS-15B HB15-1.5-A 15V, 1.5A B
OLS-15C HC15-3-A 15V, 3.0A C
OLS-15N HN15-4.5-A 15V, 4.5A N
OLS-15D HD15-6-A 15V, 6.0A D
24 V OLT S
OLS-24B HB24-1.2-A 24V, 1.2A B
OLS-24C HC24-2.4-A 24V, 2.4A C
OLS-24N HN24-3.6-A 24V, 3.6A N
OLS-24D HD24-4.8-A 24V, 4.8A D
OVP MODULE
OVP-1 OVP-12 6.4V34V OVP
CASE DIMENSIONS WT
SIZE (L" xW"x H") (LBS)
B 4.87X4.00X2.07 2
C 5.62X4.87X2.95 4
D 9.00X4.87X3.28 7.5
N 7.00X4.87X3.20 6
AA 6.50X4.00X2.07 2
BB 7.00X4.78X2.95 4
CC 9.38X4.87X3.28 7
131 11.0X4.87X2.75 9
OVP-1 1.58X1.58X0.50