DATA SHEET
Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701
Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670
www.ametherm.com
Part Number: SL10 30002
Ordering Different Lead Types:
For example: to order an inside kinked lead use part number SL10 30002-A
Electrical Specifications: Mechanical Specifications:
CSA File Number: #CA118061 Revision Date: March 19, 2003
Inside Kinked Leads Use -A after Ametherm’s part #
Outside Kinked Leads Use -B after Ametherm’s part #
Resistance @ 25°C 30.0 ± 15 %
Max Steady State Current Up to 65°C 2.0 A
Max Recommended Energy Rating (Joul es) 15.0 J
Actual Failure Point of Instantaneous Energy (Joules) 40.0 J
Resistance @ 100% of Max Current 0.495
Resistance @ 50% of Max Current 1.10
Body Temperature @ 100% Current Rating 147 °C
Dissipation Constant 11.0mW/°C
The rmal Time Co nst ant 25 second s
Material Type “G”
Max Recommended Capacitance @ 120/240VAC 1000µF/250µF
D 10.0 ± 0.5 mm
T 3.0 ± 0.2 mm
Lead Diameter 0.4 ± 0.04 mm
S 5.1 ± 1.0 mm
L 12.7 ± 1.0 mm
Coati ng Run Down
Above the Kink 3.50 ± 0.3 mm
B 11.5 ± 3.50 mm
C 2.1 ± 0.3 mm
L
OUTSIDE
KINKED LEADS
S
STRAIGHT
LEADS
B
INSIDE
KINKED LEADS
S S
D D D
C
T