KILOVAC WD Series, DIN Rail or Screw Mounted Protective Relays
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-2
KILOVAC WD25 Paralleling Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-3
KILOVAC WD2759 Over/Undervoltage Relays . . . . . . . . . . . . . . . . . . . . . . . . . .11-4, 11-5
KILOVAC WD32 Reverse Power Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-6, 11-7
KILOVAC WD47 Phase Sequence Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-8
KILOVAC WD5051 1Ø and 3Ø Overcurrent Relays . . . . . . . . . . . . . . . . . . . . . .11-9, 11-10
KILOVAC WD81OU Over/Underfrequency Relays . . . . . . . . . . . . . . . . . . . . . . . . . . .11-11
Voltage Sensitive Relays
WUV/WOV DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-12
WUV/WOV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-13
WUVT/WOVT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-14
WOUV DC Series, Over/Undervoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-15
WOUVT Series, Over/Undervoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-16
250 Series, Over/Undervoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-17
D100X Series, Close Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-18
D101X Series, 3 Phase Adjustable, Close Differential . . . . . . . . . . . . . . . . . . . . . . . .11-19
Reverse Power Relay
700 Series w/ Adjustable Time Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-20
Phase Failure Relay
1000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-21
Phase Sequence Relay
900 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-22
Current Balance Relay
WCB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-23
Current Sensitive Relays
WC1 & WCT1 Series, Overcurrent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-24
WC3 & WCT3 Series, Overcurrent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-25
Current Differential Relay
WCD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-26
Paralleling Relays
1800 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-27
Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-27
Frequency Sensitive Relays
WOF & WUF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-28
WOUF Series, Over/Underfrequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-29
20-000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-30
25-000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-31
20-050-19 Series (Voltage/Frequency) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-32
Ground Fault Relays
WGD Series — Floating Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-33
WC1G Series — Grounded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-34
Additional Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-35 – 11-43
11–2
KILOVAC WD Series, DIN Rail or Screw Mounted Protective Relays
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Product Facts
nWD25 Paralleling (Synch
Check) Relays
nWD2759 Over/undervoltage
Relays
nWD32 Reverse Power
Relays
nWD47 Phase Sequence
Relays
nWD5051 Single- or Three-
Phase Overcurrent Relays
nWD81OU
Over/Underfrequency Relays
nFile E58048,
DIN EN50022-35
Installation and Maintenance
Information
Installation — To mount the WD
series protective relay on a DIN rail,
hook the top edge of the cutout on the
base of the case over one edge of the
DIN rail, then press the opposite side of
the cutout containing the release clip
over the opposite side of the DIN rail. To
remove or reposition the relay, lever the
release clip and move the relay as
required. WD series relays should be
installed in a dry location where the
ambient temperature will be within the
operating temperature range.
Maintenance — WD series protective
relays are solid state devices that require
no maintenance. They are not designed
to be serviced by the user. Consult
KILOVAC customer service at 805-220-
2023 if repairs should be necessary.
Users should thoroughly review the
technical data before selecting a product
part number. It is recommended that user
also seek out the pertinent approvals
files of the agencies/laboratories and
review them to ensure the product meets
the requirements for a given application.
R
Outline Dimensions
The WD series offers
several different models
of protective relays in a
common package that is
suitable for either DIN rail
or screw mounting. These
flexible, multifunction
devices offer user selectable
voltages, sense currents
and frequencies. Adjustable
time delays are standard.
This allows a single part
number to be suitable for
multiple applications,
thereby reducing inventory
costs.
Specifications Common to
All Models
Power Consumption
2.5VA, maximum.
Contact Ratings
5 amps, resistive, at 120VAC.
5 amps, resistive, at 30VDC.
Isolation from Control to Sense
Inputs — 2,500VAC.
Mechanical Life
10 million operations.
Shock — 10g.
Vibration — 0.062 (1.57) double
amplitude at 10-55 Hz.
Terminals — M3.5 screws.
Maximum Wire Size — 2 x 24 AWG
(2.5mm2) solid to DIN 46288 or 2 x 16
AWG (1.5mm2) stranded w/end sleeves.
Operating Temperature Range
-40°C to +60°C.
Enclosure — Plastic case (not sealed).
Mounting Options — Snap mounts
on standard DIN rail (DIN-EN 50022-35)
or panel mounts with M4, M5, #8 or
#10 screws.
Weight — 14.4 oz. (400g) approxi-
mately.
4.41
(112.0)
0.35
(9.0)
2.95
(75.0)
2.36
(60.0)
2.36
(60.0)
1.97
(50.0)
M5
M4
2.87
(73.0)
1.38
(35.0)
16 X M3.5
WD25 Operation
WD25 paralleling relays
are used to ensure that two
circuits are synchronized.
When voltage, phase
relationship and frequency
are within the selected
synchronizing limits, the
output relay will energize.
The WD25 paralleling relay
allows for a generator to be
brought online without dam-
age or system disturbance.
WD25 series with a "dead
bus" feature will energize for
a synchronized condition or
an "on line" generator, "dead
bus" condition. This "dead
bus" feature allows the gen-
erator to energize a dead
bus. The "double dead bus"
feature permits paralleling
of two buses when: (a) both
the line voltages are equal
and in phase, or (b) when
either bus is "hot" and the
other bus is "dead."
WD25 Specifications
Nominal Operating Range
120, 208, 277 or 480 VAC, selectable.
Maximum Sensing Range
575VAC.
Nominal Frequency Range
40-400 Hz.
Contact Form — 2 form C (DPDT).
WD25 Calibration
The calibration marks on the faceplate
are provided only as guides. Proper
calibration requires using an accurate
voltmeter. Use the following procedure
to calibrate the WD25:
1. Remove the cover.
2. Adjust the SYNC VOLTAGE control
fully counterclockwise (CCW). Apply
nominal voltage to the LINE B (bus)
sensing terminals.
3. Apply the maximum desired
synchronization voltage to the LINE A
(generator) terminals. This voltage
should be in phase with LINE B (bus)
voltage and have the same frequency.
4. Slowly adjust the SYNC VOLTAGE
control clockwise (CW) until the relay
energizes.
11–3
KILOVAC WD25 Paralleling Relays
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Product Facts
nFunction 25
nANSI/IEEE C37.90-1978
Sense Voltage
Voltage (nominal) 120 208 277 480
Synch Voltage (% of nom.) 6 - 30% ( 4°- 20° electrical degree)
Dead Bus Voltage (% of nom.) 10 - 70% (Dead Bus)
Control Voltage
Model WD25 -0X1 -0X2 -0X3
Input Voltage (VDC) 18 to 54 13.5 to 32 100 to 200
Input Voltage (VAC) ——100 to 140
Ordering Information
Typical Part Number WD 25 -00 2
1. Basic Series:
WD = DIN mount Protective Relay.
2. Type:
25 = Paralleling Relay.
3. Dead Bus:
00 = Double Dead Bus
01 = Single Dead Bus
02 = Generator to Generator
4. Control Voltage:
1 = 18 to 54VDC
2 = 13.5 to 32 VDC
3 = 100-200VDC or 100-140VAC.
Our authorized distributors are more likely to stock these items.
WD25-001
WD25-013
WD25 Controls
WD25 Connections
WD25 Typical Hookup
NOTE: For single dead bus option,
connect the generator to 1 & 3 and
the bus to 5 & 7.
11–4
KILOVAC WD2759 Over/Undervoltage Relays
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WD2759 Operation
WD2759 AC voltage sens-
ing relays provide voltage
monitoring and protection
in AC systems from 50 to
400 Hz. Sensing voltages,
number of phases, over and
undervoltage setpoint, and
time delays are user config-
ured. WD2759 voltage
relays operate when the
externally adjustable trip
point is reached. An exter-
nal time delay control is
provided with an adjustment
of .5 to 10 seconds. This
time delay may be used to
prevent false tripping when
there are slight variations
in the voltage supply. On
overvoltage (OV) the output
relay energizes when the
input signal exceeds the trip
point. On undervoltage
(UV) the output relay ener-
gizes when the input signal
goes below the trip point.
A green LED indicates
power to the relay. Red
LED lights indicate the state
of the undervoltage and
overvoltage trips.
WD2759 Specifications
Nominal Operating Range
120, 208, 277 or 480 VAC, selectable.
Maximum Sensing Range
700VAC.
Nominal Frequency Range
50-400 Hz.
Contact Form — 1 form C (SPDT) for
undervoltage and 1 form C (SPDT) for
overvoltage.
Time Delay Adjustment
0.5 to 10 sec.
WD2759 Calibration
The calibration marks on the faceplate
have a maximum error of 10% and are
provided only as guides. Proper
calibration requires using an accurate
voltmeter in parallel with the input
signal. Use the following procedure to
calibrate your relay.
OVER VOLTAGE
1. Remove cover.
2. Adjust the TRIP SET control fully
clockwise (CW) and the TIME DELAY
control fully counterclockwise (CCW).
3. Apply the desired trip voltage to the
relay.
4. Slowly adjust the TRIP SET control
CCW until the relay trips.
5. Remove the applied voltage (do not
change the voltage level) and set the
TIME DELAY control to the desired
time delay.
6. Apply the trip voltage to the relay and
measure the time to trip.
7. Adjust the TIME DELAY and repeat
steps 4 and 5 until you have the
desired time delay.
UNDER VOLTAGE
1. Remove cover.
2. Adjust the TRIP SET control fully
CCW and the TIME DELAY control
fully CCW.
3. Decrease the applied sensing voltage
from the nominal value until the
desired tripping voltage is reached.
4. Slowly adjust the TRIP SET control
CW until the relay trips.
5. Set the TIME DELAY control to the
desired time delay and apply nominal
voltage to the relay.
6. Step down the applied voltage from
nominal to a level jest below the trip
level set in Step 3 and measure the
time delay.
7. Adjust the TIME DELAY and repeat
steps 4 and 5 until the desired time
delay is achieved.
Product Facts
nFunction 27/59
nANSI/IEEE C37.90-1978
Sense Voltage
Voltage (nominal) 120 208 277 480
UV Adjustment Range 72-120 125-208 166-277 288-480
OV Adjustment Range 120-168 208-291 277-388 480-672
Control Voltage
Model WD2759 -001 -002 -003
Input Voltage (VDC) 18 to 54 13.5 to 32 100 to 200
Input Voltage (VAC) ——100 to 140
Ordering Information
Typical Part Number WD 2759 -002
1. Basic Series:
WD = DIN mount Protective Relay.
2. Type:
2759 = Over/Undervoltage Relay.
3. Control Voltage:
001 = 18 to 54VDC
002 = 13.5 to 32 VDC
003 = 100-200VDC or 100-140VAC.
Our authorized distributors are more likely to stock these items.
WD2759-003
11–5
KILOVAC WD2759 Over/Undervoltage Relays (Continued)
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WD2759 Controls
WD2759 Connections
WD2759 Typical Hookup
11–6
KILOVAC WD32 Reverse Power Relays
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WD32 Operation
WD32 reverse power relays
are used to monitor the
direction of power from AC
generators. This is accom-
plished by measuring I cos
q. If current from the gener-
ator is reversed and
exceeds the adjustable set-
ting, the relay will trip. A 0.5
to 20 second time delay is
provided. A correct setting
of the trip point and time
delay will prevent motoriz-
ing the generator and pre-
vent tripping during
transients that occur while
synchronizing. A POWER
LED indicates the condition
of the power supply and a
REVERSE POWER TRIP
LED indicates the output
status of the relay.
WD32 Specifications
Nominal Operating Range
120 to 480 VAC, 1 or 3 phase.
Maximum Sensing Range
575VAC.
Nominal Sensing Current — 5A.
Nominal Frequency Range
WD32-00X — 40-400 Hz.;
WD32-01X — 60 Hz.
Contact Form — 2 form C (DPDT).
Time Delay Adjustment
0.5 to 20 sec.
Sense Current — Reverse Power
Trip: 0.2 to 1.0A (4-20% of nominal
sense current).
WD32 Calibration
The calibration marks on the faceplate
have a maximum error of 10% and
are provided only as guides. Proper
calibration requires using an accurate
Current Meter in series with the input
current. Use the following procedure to
calibrate your relay.
REVERSE POWER
1. Remove cover.
2. Adjust the TRIP SET control fully
clockwise (CW) and the TIME DELAY
control fully counterclockwise (CCW).
3. Apply the desired trip current to the
relay. NOTE: for the Reverse Power
(WD32-00X) a resistive load must
be used and for the Reverse kVAR
(WD32-01X) an inductive load must
be used.
4. Slowly adjust the TRIP SET control
CCW until the relay trips.
5. Remove the applied Current and set
the TIME DELAY control to the
desired time delay.
6. Re-apply the Current (10% more than
the trip current) to the relay and
measure the time to trip.
7. Adjust the TIME DELAY and repeat
steps 4 and 5 until you have the
desired time delay.
Product Facts
nFunction 32
Control Voltage
Model WD32 -001 -002 -003
Input Voltage (VDC) 18 to 54 13.5 to 32 100 to 200
Input Voltage (VAC) —˜100 to 140
Ordering Information
Typical Part Number WD 32 -00 2
1. Basic Series:
WD = DIN mount Protective Relay.
2. Type:
32 = Reverse Power Relay.
3. Load:
00 = Resistive (power)
01 = Inductive (kVAR, 60 Hz.)
4. Control Voltage:
1 = 18 to 54VDC
2 = 13.5 to 32 VDC
3 = 100-200VDC or 100-140VAC.
Our authorized distributors are more likely to stock these items.
WD32-003
WD32-011
11–7
KILOVAC WD32 Reverse Power Relays (Continued)
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WD32 Controls
WD32 Connections
WD32 Typical Hookup
11–8
KILOVAC WD47 Phase Sequence Relays
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WD47 Operation
WD47 phase sequence
relays are designed to
monitor the correct phase
rotation and loss of phase
of three phase ac systems
from 50 to 400 Hz. An
incorrect phase sequence
or loss of any phase will
cause the WD47 to pickup.
When the phase sequence
is corrected or the lost
phase is restored the
contacts dropout. Red
LED's light to indicate a
fault condition. A green
LED indicates power to the
relay. The WD47 is often
used to detect reverse
phase rotation or loss of
phase to generators, busses,
motors, and transformers.
WD47 Specifications
Nominal Operating Range
120 to 480 VAC.
Maximum Sensing Range
575VAC.
Nominal Frequency Range
40-400 Hz.
Contact Form — 2 form C (DPDT).
WD47 Calibration
The WD47 has no adjustments and
no calibration is necessary. Proper
operation may be verified as follows:
1. Apply a nominal, three-phase input
with the correct phase sequence.
The output relay should dropout and
the green LED should light.
2. Apply a nominal, three-phase input
with an incorrect phase sequence.
The output relay should pickup and
the red LED should light.
3. Apply only one or two phases with
the correct phase sequence. The
output relay should pickup and the
red LED should light.
Product Facts
nFunction 47
nANSI/IEEE C37.90-1978
Control Voltage
Model WD47 -001 -002 -003
Input Voltage (VDC) 18 to 54 13.5 to 32 100 to 200
Input Voltage (VAC) ——100 to 140
Ordering Information
Typical Part Number WD 47 -002
1. Basic Series:
WD = DIN mount Protective Relay.
2. Type:
47= Phase Sequence Relay.
3. Control Voltage:
001 = 18 to 54VDC
002 = 13.5 to 32 VDC
003 = 100-200VDC or 100-140VAC.
Our authorized distributors are more likely to stock these items.
WD47-001
WD47 Controls
WD47 Connections
WD47 Typical Hookup
11–9
KILOVAC WD5051 1Ø and 3Ø Overcurrent Relays
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Product Facts
nFunction 5051
WD5051 Operation
WD5051 AC current sens-
ing relays provide current
monitoring and protection in
AC systems from 50 to 400
Hz. Nominal Sensing
Current, Instantaneous Over
Current setpoint, Time Over
Current setpoint, and Time
Over Current time delay are
user configured. WD5051
current relays operate when
the externally adjustable trip
point is reached. An exter-
nal time over current time
delay control is provided
with an adjustment of .5 to
20 seconds. This time delay
may be used to prevent
false tripping when there
are slight variations in the
sensed current. With control
power applied, the
Instantaneous Over Current
(IOC) contacts pick-up
when the input signal
exceeds the IOC trip set-
point. Similarly, with control
power applied, the Time
Over Current (TOC) con-
tacts pick-up after the pre-
set time delay when the
Sense Current rises above
the TOC trip setpoint. The
IOC contacts may also be
configured to function as an
under current relay. A
green LED indicates power
to the relay. Red LED lights
indicate the state of the IOC
and TOC trips.
WD5051 Specifications
Sense Current Full Scale — 1, 3, 6
or 8A, selectable.
Maximum Sensing Current
10A continuous; 30A for 10 sec.;
60A for 2.5 sec.; 100A for 0.9 sec..
Nominal Frequency Range
50-400 Hz.
Contact Form — 1 form C (SPDT) for
IOC and 1 form C (SPDT) for TOC.
TOC Time Delay Adjustment
0.5 to 20 sec.
IOC Operate Time (max.)
0.2 sec.
WD5051 Calibration
The calibration marks on the faceplate
are provided only as guides. Proper cal-
ibration requires using an accurate
ammeter in series with the current
source. Use the following procedure to
calibrate your relay:
OVERCURRENT
1. Remover the cover.
2. Adjust the TRIP SET control fully
clockwise (CW) and the TIME DELAY
control (TOC only) fully counter-
clockwise (CCW).
3. Apply the desired trip current to the
relay.
4. Slowly adjust the TRIP SET control
CCW until the relay trips.
5. Remove the applied current (do not
change the current level). Set the
TIME DELAY (TOC only) control to
the desired time delay.
Sense Current
Current (nominal) 1368
IOC 0.2 to 1.2 0.6 to 3.6 1.2 to 7.2 1.6 to 9.6
TOC 0.2 to 1.2 0.6 to 3.6 1.2 to 7.2 1.6 to 9.6
Control Voltage
Model WD5051 -001 -002 -003
Input Voltage (VDC) 18 to 54 13.5 to 32 100 to 200
Input Voltage (VAC) ——100 to 140
Ordering Information
Typical Part Number WD 5051 -002
1. Basic Series:
WD = DIN mount Protective Relay.
2. Type:
5051 = Single Phase Overcurrent Relay.
5051-3 = Three Phase Overcurrent Relay.
3. Control Voltage:
001 = 18 to 54VDC
002 = 13.5 to 32 VDC
003 = 100-200VDC 0r 100-140VAC.
Our authorized distributors are more likely to stock these items.
WD5051-001
WD5051-003
WD5051-3-001
11–10
KILOVAC WD5051 1Ø and 3Ø Overcurrent Relays (Continued)
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WD5051 Controls
WD5051 Connections
WD5051 Typical Hookup
WD5051
Single Phase Model
WD5051-3
Three Phase Model
WD5051
Single Phase Model
WD5051-3
Three Phase Model
11–11
KILOVAC WD81OU Over/Underfrequency Relays
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Product Facts
nFunction 81 OU
nANSI/IEEE C37.90-1978
Control Voltage
Model WD81OU -001 -002 -003
Input Voltage (VDC) 18 to 54 13.5 to 32 100 to 200
Input Voltage (VAC) ——100 to 140
Ordering Information
Typical Part Number WD 81OU-002
1. Basic Series:
WD = DIN mount Protective Relay.
2. Type:
81OU = Over/Underfrequency Relay.
3. Control Voltage:
001 = 18 to 54VDC
002 = 13.5 to 32 VDC
003 = 100-200VDC or 100-140VAC.
Our authorized distributors are more likely to stock these items.
None at present.
WD81OU Controls
WD81OU Connections
WD81OU Typical Hookup
Sense Frequency
Frequency (nominal) 50 60 400
UF Adjustment Range 40-50 48-60 360-400
OF Adjustment Range 50-60 60-72 400-480
WD81OU Operation
WD81OU frequency
relays are used to provide
frequency monitoring and
protection to generators,
buses, power supplies, and
other equipment. The relay
operates at voltages from
120 to 480 Vac and at
nominal frequencies of 50,
60, and 400 Hz. External
controls include nominal
frequency selection, under
frequency (UF) trip set,
over frequency (OF) trip
set, UF time delay, and OF
time delay. A green LED
indicates power to the
relay. Red LED’s indicate
the status of the UF and
OF trips.
WD81OU Specifications
Nominal Operating Frequency
50, 60 or 400 Hz., selectable.
Maximum Frequency @ 400 Hz.
Nominal — 1000 Hz.
Nominal Sensing Voltage
20-480VAC.
Maximum Sensing Voltage
575VAC.
Contact Form — 1 form C (SPDT) for
underfrequency and 1 form C (SPDT) for
overfrequency.
Time Delay Adjustment — 0.5 to 10
sec.
WD81OU Calibration
The calibration marks on the faceplate
are provided only as guides. Proper
calibration requires using an accurate
frequency meter in parallel with the input
signal.
UNDER FREQUENCY
1. Remove the cover.
2. Set the SENSE FREQUENCY to the
nominal system frequency. Adjust the
Under Frequency TRIP SET fully
clockwise (CW) and the TIME DELAY
control fully counterclockwise (CCW).
3. Apply the desired trip frequency to
the relay.
4. Slowly adjust the TRIP SET control
CCW until the relay trips.
5. Set the TIME DELAY control to the
desired time delay and apply nominal
frequency to the relay.
6. Step down the applied frequency
from nominal to just below the trip
level set in Step 4 and measure the
time delay.
7. Adjust the TIME DELAY and repeat
steps 5 and 6 until the desired time
delay is set.
OVER FREQUENCY
1. Remove the cover.
2. Set the SENSE FREQUENCY to the
nominal system frequency. Adjust
the OF TRIP SET and TIME DELAY
controls fully counterclockwise (CCW).
3. Apply the desired trip frequency to
the relay.
4. Slowly adjust the TRIP SET control
clockwise (CW) until the relay trips.
5. Set the TIME DELAY control to the
desired time delay and apply nominal
frequency to the relay.
6. Step down the applied frequency from
nominal to just below the trip level set
in Step 4 and measure the time delay.
7. Adjust the TIME DELAY and repeat
steps 5 and 6 until the desired time
delay is set.
11–12
WUV/WOV DC Series
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Undervoltage Models
The relay is energized at
normal voltage, N.C. con-
tacts will open and N.O.
contacts will close. The
relay will de-energize when
the voltage drops below the
U/V set point.
Overvoltage Models
The relay is de-energized at
normal voltage, N.C. con-
tacts are closed and N.O.
contacts are open. The
relay will energize, when the
voltage rises above the O/V
set point.
Product Facts
nANSI/IEEE C37.90-1978
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Product Specifications
Nominal Voltage — 12 VDC to 560
VDC
Drop-out Point (u/v models)
70-100% of nominal voltage,
screwdriver adjustable
Pick-Up Point (o/v models)
100-125% of nominal voltage,
screwdriver adjustable
Output Contacts — One set N.O.,
One set N.C.
Contact Ratings
5 amp resistive at 120 VAC or 28 VDC
Operating Temperature Range
-40˚C to +75˚C
Temperature Effects — Less than
1% voltage drift over the temperature
range
Power Consumption
12 to 60 VDC models — 1 W max.
120 to 305 VDC models — 2 W max.
405 to 470 VDC models — 3 W max.
560 VDC model — 4 W max.
Time Delay — A short duration delay
is provided to prevent nuisance tripping
due to momentary dips or surges in volt-
age. The drop-out delay, following a
voltage fault is 75 to 100 milliseconds.
Notes:
1. Remove black screws for
access to the O/V and U/V trip
adjustment.
2. Clockwise rotation of the adjust-
ment potentiometer will raise the
voltage trip point.
3. The adjustments are by means of
a single turn potentiometer. Use a
small screwdriver and do not force
beyond the limit stops.
Ordering Information
Sample Part Number WOV-12DC -A
Type:
WOV - Overvoltage
WUV - Undervoltage
Line Voltage VDC
12DC 125DC
18DC 240DC
24DC 250DC
28DC 305DC
32DC 405DC
48DC 430DC
60DC 470DC
120DC 560DC
Options:
Blank - Standard
A = 2 Form A Contacts
B = 2 Form B Contacts
H = 125 VDC Contacts
P = Transient Protection
Transient Protection — All voltage
relays will withstand momentary voltage
surges of twice the nominal rated input
voltage (standard).
Option “P” provides additional tran-
sient protection which complies with the
requirements of ANSI/IEEE C37.90-1978
Consult factory for additional
models.
(+) (–)
11/64" DIA.
4 MTG. HOLES
3.0
3 1/2
3 7/8
3.0
2 3/4
3 1/2
TERMINAL STRIPS
#6 - 32 SCREWS
11–13
WUV/WOV Series
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Voltage sensitive relays are
available for both AC and
DC applications for
over/undervoltage protec-
tion. Combination
over/undervoltage relays
provide bandpass capabili-
ties. AC relays are either
single or three-phase type.
Three phase models are
designed to sense the aver-
age of the three phases or
the highest single phase.
Voltage trip points are
screwdriver adjustable, and
operation is time-delayed so
that momentary voltage
transients will not cause nui-
sance tripping.
Product Specifications
Nominal Voltage — 120 VAC to 575
VAC
Phase — Single or Three
Line Frequency — 50-400 Hz
Pick-up to Drop-out Differential
2.5% maximum
Drop-out Point (u/v models)
70-100% of nominal voltage,
screwdriver adjustable
Pick-Up Point (o/v models)
100-125% of nominal voltage,
screwdriver adjustable
Output Contacts — One set N.O.,
One set N.C.
Contact Ratings
5 amp resistive at 120 VAC or 28 VDC
Operating Temperature Range
-20˚C to +65˚C
Power Consumption
2 VA maximum
Time Delay — 150-300 ms (UV Model)
Minimum Life — 500,000 operations
Notes:
1. Remove black screw for access to
the voltage trip adjustment.
2. Clockwise rotation of the adjust-
ment potentiometer will raise the
voltage trip point.
Product Facts
nFunction 27/59
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
Ordering Information
Sample Part Number WUV -1 -120
Type:
WUV - Undervoltage
WOV - Overvoltage
No. Phases
1 = Single
3 = Three
Line Voltage VAC
120 416
208 440
220 460
230 480
240 525
380 575
Options
P - Transient Protection
A - Two Normally Open Contacts
B - Two Normally Closed Contacts
H - 125VDC, 3A Contacts
Single Phase
R
R
Three Phase
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Typical Time Curve
-10.0
0.0
10.0
20.0
30.0
40.0
00.050.10.150.20.250.3
Pick-Up Time Delay
Overvoltage Relays
WOV Series
Transient Protection — All voltage
relays will withstand momentary voltage
surges of twice the nominal rated input
voltage (standard).
Option “P” provides additional tran-
sient protection which complies with the
requirements of ANSI/IEEE C37.90-1978
Consult factory for additional
models.
11–14
WUVT/WOVT Series
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
11/64" DIA.
4 MTG. HOLES
3 5/8
4 1/8
4 1/2
3.0
TERMINAL STRIPS
#6 - 32 SCREWS
3 1/2
4 1/4
Undervoltage Models
The relay is energized at
normal voltage, N.C. con-
tacts will open and N.O.
contacts will close. The
relay will de-energize when
the voltage drops and
remains below the U/V set
point for the duration of the
set time delay.
Overvoltage Models
The relay is de-energized at
normal voltages, N.C. con-
tacts are closed and N.O.
contacts are open. The
relay will energize, when the
voltage rises and remains
above the O/V set point for
the duration of the set time
delay.
Product Specifications
Nominal Voltage — 100 VAC to 575
VAC
Phase — Single or Three
Line Frequency — 50-400 Hz
Pick-up to Drop-out Differential
1% typical
Drop-out Point (u/v models)
70-100% of nominal voltage,
screwdriver adjustable
Pick-Up Point (o/v models)
100-125% of nominal voltage,
screwdriver adjustable
Output Contacts — One set N.O.,
One set N.C.
Contact Ratings
5 amp resistive at 120 VAC or 28 VDC
Operating Temperature Range
-40˚C to +70˚C
Power Consumption
3 VA maximum
Time Delay — 0.5 to 20 seconds,
screwdriver adjustable
Voltage Reset — The reset is auto-
matic when voltage returns to normal.
Notes:
1. Remove black screws for access
to the voltage and time delay
adjustment potentiometer.
2. Clockwise rotation of the voltage
adjust potentiometer will raise the
voltage trip point.
3. Clockwise rotation of the time
adjust potentiometer will increase
the time delay (Pick-up time for
O/V models, drop-out time for U/V
models).
4. The adjustments are single turn
potentiometers, use a small
screwdriver and do not force
beyond the limit stops.
5. On U/V models, when the voltage
falls to approximately 33% of
nominal or below, the relay will
drop out in 0.150 to 0 .300 sec-
onds, regardless of the time delay
setting.
Product Facts
nFunction 27/59
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
Ordering Information
Sample Part Number WUVT -1 -120
Type:
WUVT - Undervoltage
WOVT - Overvoltage
No. Phases
1 = Single
3 = Three (line to line)
Line Voltage VAC
100 240
115 380
120 416
150 440
200 460
208 480
220 525
230 575
Options:
Blank - Standard
A = 2 Form A Contacts
B = 2 Form B Contacts
H = 125VDC 3A Contacts
P = Transient Protection
R
R
Three PhaseSingle Phase
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Transient Protection — All voltage
relays will withstand momentary voltage
surges of twice the nominal rated input
voltage (standard).
Option “P” provides additional tran-
sient protection which complies with the
requirements of ANSI/IEEE C37.90-1978
Consult factory for additional
models.
11–15
WOUV DC Series, Over/Undervoltage
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
The relay will energize at
normal voltage conditions.
The normally open contacts
will close, and the normally
closed contacts will open.
The relay will de-energize
during over or undervoltage
conditions. Reset is auto-
matic when the voltage
returns to normal.
Product Specifications
Nominal Voltage (±10%)
12 VDC to 560 VDC
Drop-out Point (u/v models)
70-100% of nominal voltage,
screwdriver adjustable
Pick-Up Point (o/v models)
100-125% of nominal voltage,
screwdriver adjustable
Output Contacts — One set N.O.,
One set N.C.
Contact Ratings
5 amp resistive at 120 VAC or 28 VDC
Operating Temperature Range
-40˚C to +75˚C
Temperature Effects
Less than 1% voltage drift over the tem-
perature range.
Power Consumption
12 to 60 VDC models — 1 W max.
120 to 305 VDC models — 2 W max.
405 to 470 VDC models — 3 W max.
560 VDC Model — 4 W max.
Time Delay — A short duration delay
is provided to prevent nuisance tripping
due to momentary dips or surges in volt-
age. The drop-out delay, following a
voltage fault is 75 to 100 milliseconds
Notes:
1. Remove black screws for access
to the O/V and U/V trip adjust-
ment.
2. Clockwise rotation of the adjust-
ment potentiometer will raise the
voltage trip point.
3. The adjustments are by means of
a single turn potentiometer. Use a
small screwdriver and do not force
beyond the limit stops.
Product Facts
nANSI/IEEE C37.90-1978
Ordering Information
Sample Part Number WOUV -12DC -A
Type:
WOUV - Over/Undervoltage
Line Voltage VDC
12DC 125DC
18DC 240DC
24DC 250DC
28DC 305DC
32DC 405DC
48DC 430DC
60DC 470DC
120DC 560DC
Options:
Blank - Standard
A = 2 Form A Contacts
B = 2 Form B Contacts
H = 125 VDC Contacts
P = Transient Protection
Single Phase
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Drop-Out Time Delay WOUV...DC Series
0
20
40
60
80
100
120
140
160
180
020406080100120140
Time Delay (msec)
Percent of Nominal Voltage
Transient Protection — All voltage
relays will withstand momentary voltage
surges of twice the nominal rated input
voltage (standard).
Option “P” provides additional tran-
sient protection which complies with the
requirements of ANSI/IEEE C37.90-1978
Consult factory for additional
models.
11/64" DIA.
4 MTG. HOLES
3
3 1/2
3 7/8
2 13/16
2.0
2 3/4
3 1/2
TERMINAL STRIPS
#6 - 32 SCREWS
11–16
WOUVT Series, Over/Undervoltage
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Voltage sensitive relays are
available for both AC and
DC applications for overvolt-
age and undervoltage
protection. Combination
over/undervoltage relays
provide band-pass capabili-
ties. AC relays are either
single or three-phase type.
Three phase relays are
designed to sense the aver-
age of the three phases.
Voltage trip points are
screwdriver adjustable, and
operation is time-delayed
so that momentary voltage
transients will not cause
nuisance tripping.
Operation
The relay will energize at
normal voltage condition.
The normally closed contact
(Form B) will open and the
normally open (Form A) will
close. The relay will de-
energize after time delay
when over or undervoltage
condition is reached.
Product Specifications
Nominal Voltage — 120 VAC to 575
VAC
Phase — Single or Three
Line Frequency — 50-400 Hz
Type of Sensing — Average of all
three phases
Undervoltage Trip — 70-100% of
nominal voltage, screwdriver adjustable
Overvoltage Trip — 100-125% of
nominal voltage, screwdriver adjustable
Drop-out Time Delay — 0.5 to 20
seconds, screwdriver adjustable
Pick-up to Drop-out Differential
2% maximum
Output Contacts — One set N.O.,
One set N.C.
Contact Ratings — 5 amp resistive at
120 VAC or 28 VDC
Operating Temperature Range
-40˚C to +70˚C
Power Consumption
4 VA maximum
Notes:
1. Remove black screw for access to
the voltage trip and time delay
adjustment potentiometer.
2. Clockwise rotation of the voltage
adjustment potentiometer will
raise the voltage trip point.
3. Clockwise rotation of the time
adjustment potentiometer will
increase the drop-out time delay.
Product Facts
nFunction 27/59
nANSI/IEEE C37.90-1978
Ordering Information
Sample Part Number WOUVT -1 -120AC
Type:
WOUVT - Over/Undervoltage
No. Phases
1 = Single
3 = Three (line to line)
Line Voltage VAC
115
120
200
208
220
230
240
380
Options:
Blank - Standard
A = 2 Form A Contacts
B = 2 Form B Contacts
H = 125 VDC Contacts
P = Transient Protection
Three Phase ModelsSingle Phase Models
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Option “H” provides for contacts rating
of 3 amps @ 125VDC.
Option “P” provides additional tran-
sient protection which complies with the
requirements of ANSI/IEEE C37.90-1978
Consult factory for additional
models.
11–17
250 Series, Over/Undervoltage
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
13/64" DIA.
4 MTG. HOLES
2.750 B.C.
3.500
2
6 -32 STUDS (6)
3
3.500 B.C.
3 7/8
The 250 series relays
provide combined
Overvoltage and
Undervoltage protection in
a single compact unit.
Models are available for
single phase or three phase
applications, and are
suitable for either 50 Hz,
60 Hz, or 400 Hz operation.
The trip point is adjustable.
A transistorized circuit
provides a sharp and
accurate response at the
preset tripping voltage;
unaffected by temperature
or frequency variations.
Product Specifications
Nominal Voltage — See Ordering
Information
Undervoltage Trip — 70-100% of
nominal voltage, screwdriver adjustable
Overvoltage Trip — 100-125% of
nominal voltage, screwdriver adjustable
Pick-up to Drop-out Differential
3% maximum
Contact Ratings — 5 amp resistive at
120 VAC or 28 VDC
Contact Form — One set N.O.,
one set N.C.
Operating Temperature Range
-20˚C to +85˚C
Notes:
1. Remove screws for access the
overvoltage or undervoltage trip
adjustments. Clockwise rotation
of the adjustment potentiometer
will raise the trip point.
Contact Arrangements
NC — Open at nominal voltage. Closed
at Overvoltage and Undervoltage
NO — Closed at nominal voltage. Open
at Overvoltage and Undervoltage
Product Facts
nFunction 27/59
nANSI/IEEE C37.90-1978
Ordering Information
Sample Part Number 250X
Model: L-L Volts
250X = 120 VAC, 1 Phase, 50-400 Hz
251X = 120/208 VAC, 3 Phase, 4 Wire, 50-400 Hz
252X = 115 VAC, 3 Phase, 3 Wire, 50-400 Hz
253X* = 230 VAC, 3 Phase, 3 Wire, 50-400 Hz
254X* = 380 VAC, 3 Phase, 3 Wire, 50-400 Hz
255X*= 460 VAC, 3 Phase, 3 Wire, 50-400 Hz
256X* = 575 VAC, 3 Phase, 3 Wire, 50-400 Hz
Mounting
Blank = Stud
X = Flange
* Enclosure height is 3.835"
Three Phase
Single Phase
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Consult factory for additional
models.
11–18
D100X Series, Close Differential
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Close Differential Relays are
voltage sensitive. The pick-
up and drop-out voltage
settings are independently
adjustable, which allows
precise setting of the differ-
ential voltage. This relay is
available in a wide range of
AC and DC voltages. Their
primary application is the
sensing and control of
transfer switches.
Operation
Monitors a single phase
AC signal, and is used for
undervoltage detection.
Has separate pick-up and
drop-out voltage settings,
providing an adjustable
hysteresis.
Product Specifications
Nominal Voltage — AC, Single
Phase, see Ordering Information
Nominal Frequency — 50 to 400 Hz.
Pick-Up Adjustment Range
67-100% of nominal voltage
Drop-Out Adjustment Range
67-100% of nominal voltage
Maximum Differential Setting
33% of nominal voltage
Minimum Differential Setting
2% of nominal voltage
Output Contacts — Form C (SPDT)
Contact Ratings — 5 Amp resistive at
120 VAC or 28 VDC
Operating Temperature Range
-20˚C to +85˚C
Expected Life — 10 million opera-
tions
Inverse Time Drop-Out
The differential relay contains a time
delay before operation so that momen-
tary voltage transients do not affect the
operation of the relay. The time delay
has an inverse time characteristic so that
excessive voltage conditions will cause a
more rapid drop-out. This time delay is
approximately 200mSec. (12 cycles) at
the trip settings and decreases to 30
mSec. at approximately 15% beyond the
trip settings.
Notes:
1. Remove black nylon protective
screws to gain access to the two
internal adjustment potentiome-
ters.
2. Clockwise rotation of the pick-up
and drop-out adjustment will raise
the voltage trip point.
3. The relay contacts are shown in
the de-energized state.
Product Facts
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
Ordering Information
Sample Part Number D100X
Model: L-L Volts Height
D100X = 120 VAC 2"
D100-6X = 120 VAC, Spike Suppression 2"
D100-3X = 208 VAC 3.125"
D100-4X = 240 VAC 3.125"
D100-8X = 277 VAC 3.125"
D100-5X = 480 VAC 3.125"
D100-7X = 510 VAC 3.125"
Surge Withstand Capability is in
compliance with the requirements of
ANSI/IEEE C37.90B
Consult factory for additional
models.
R
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
11–19
D101X Series, 3 Phase Adjustable, Close Differential
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
13/64" DIA.
4 MTG. HOLES
4 1/4
5.0
5 1/2
H1
H2
#6 - 32 STUDS
10 PLACES
4.0
5.0
Close Differential Relays are
voltage sensitive. The pick-
up and drop-out voltage
settings are independently
adjustable, which allows
precise setting of the differ-
ential voltage. This relay is
available in a wide range of
AC voltages. Their primary
application is the sensing
and control of transfer
switches.
Operation
The output contacts will
close when the voltage of
all three phases is above
the pre-set pick-up point,
and will open when any
one phase drops below its
drop-out setting.
Product Specifications
Nominal Voltage — AC, Three Phase,
see Ordering Information
Nominal Frequency — 50 to 500 Hz.
Pick-Up Adjustment Range
66-100% of nominal voltage, screw-
driver adjustable
Drop-Out Adjustment Range
66-100% of nominal voltage, screw-
driver adjustable
Output Contacts — SPNO
Contact Ratings — 5 amp resistive at
120 VAC or 28 VDC
Operating Temperature Range
-20˚C to +85˚C
Notes:
1. Remove screws for access to
pick-up and drop-out trip adjust-
ments.
2. Clockwise rotation of the pick-up
and drop-out adjustment will raise
the voltage trip point.
Product Facts
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
Ordering Information
Sample Part Number D101X
Model: L-L Volts
D101X = 120 VAC
D101-6X = 208 VAC
D101-4X = 240 VAC
D101-10X = 380 VAC
D101-7X = 480 VAC
R
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Consult factory for additional
models.
Model Power Consumption H1 H2
Each Phase (inches) (inches)
D101X 2 VA max. 2 2 11/16
D101-4X 3 VA max. 3 1/2 4 3/16
D101-6X 3 VA max. 3 1/2 4 3/16
D101-7X 4 VA max. 3 1/2 4 3/16
D101-10X 4 VA max. 3 1/2 4 3/16
11–20
700 Series w/ Adjustable Time Delay
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
3 7/8
4 5/8
4.0
4 1/2
4 7/8
3.0
TERMINAL STRIPS
#6 - 32 SCREWS
11/64" DIA.
4 MTG. HOLES
Several types of Reverse
Power Relays are available
including relays sensitive
to reverse reactive power
(kVAR). KILOVAC is the
leading brand of reverse
power relays. Our rugged
sealed construction
provides continuous
and reliable operation
unaffected by shock,
vibration or other severe
environments. Reverse
Power Relays are used for
the protection of generator
sets operating in parallel.
Product Specifications
Line Voltage
Model 710TD — 120 V, 220 V or 266 V,
line to neutral
Model 730TD — 120 V, 230 V, 380 V,
460 V, L-L, 3 Phase or 120 V, Single
Phase, L-N
All models for three phase, three wire
sensing are available, see Ordering
Information
Line Frequency — 50-500 Hz.
Current Requirements
0 to 5 amp max direct or from CT with
5 amp secondary
Trip Adjustment
Screwdriver adjustable 4% to 20% (of
the 5 amp rating)
Time Delay Adjustment — 0.5 to 20
seconds, screwdriver adjustable
Output Contacts — One set N.O., one
set N.C.
Contact Ratings — 5 amp resistive at
120 AC or 28 Vdc
Power Consumption
Voltage circuit — 2 VA max.
Current circuit — 4 VA max.
Weight — 2.75 lbs. max.
Notes:
1. Remove screw for access to the
pick-up and time delay adjust-
ments.
2. Clockwise rotation of the pick-up
adjustment will raise the reverse
trip point.
3. Clockwise rotation of the time
adjustment will increase the time
delay.
4. Polarity of the voltage and the cur-
rent connections must be
observed for true power sensing.
5. Interchanging connections on
terminals 5 and 6, will cause the
output contacts to pick-up on
forward power and dropout on
no power or reverse power.
Product Facts
nFunction 32
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
R
R
For operation on three phase,
three wire
Designed for 120, 220 or 266 volt
line to neutral connection
Model 720TD (X) thru 724TD (X)Model 710TD
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Consult factory for additional
models.
Ordering Information
Sample Part Number 720TDX
Type:
710TD = 120V, 220V, 266V line to neutral
720TD = 120V, L-L, 3 Phase
721TD = 230V, L-L, 3 Phase
722TD = 380V, L-L, 3 Phase
723TD = 460V, L-L, 3 Phase
724TD = 575V, L-L, 3 Phase
725TD = 416V, L-L, 3 Phase
730TD = 120 V, 230 V, 380 V, 460 V, L-L, 3 Phase or
120 V, Single Phase, L-N
Mounting:
X = Flange
Blank - Stud
Options:
7 = Reverse Inductive, 60 Hz
11–21
1000 Series
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
11/64" DIA.
4 MTG. HOLES
3.0
3 1/2
3 7/8
3 13/16
2 3/4
3 1/2
TERMINAL STRIPS
#6 - 32 SCREWS
Phase failure relays protect
motors, equipment and per-
sonnel from damage or
injury caused by open
phase, reversed phase
sequence, or low voltage in
a three phase system.
Models are available for 50
and 60 Hz with voltages up
to 575 volts. Motor control
switchboards are a com-
mon application.
Operation
The contacts of the relay will
close only when it senses
normal conditions of three
phase power at the proper
phase sequence.
The relay contacts will
remain in their normally
open position (de-ener-
gized) when voltage with
incorrect phase sequence
is applied, one or more
phases are open, or at
undervoltage condition.
Product Specifications
Nominal Voltage — See Ordering
Information
Voltage Drop-Out — 75% to 100% of
nominal, screwdriver adjustable
Pick-Up to Drop-Out Differential
3% approx.
Ambient Operating Temperature
-40°C to +70°C
Temperature Drift — ± 1%
Time Delay — See Curve
Output Contacts — One set, normally
open
Contact Ratings
10 amp at 28 VDC resistive
10 amp at 230 VAC resistive
Notes:
1. Remove screw for access to the
undervoltage adjustment.
2. Clockwise rotation of the adjust-
ment potentiometer will raise the
drop-out voltage.
Product Facts
nFunction 47
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
R
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Consult factory for additional
models.
Ordering Information
Sample Part Number 1004X
Type:
1001 = 120 V, 60 Hz, 3 phase,L-L
1007 = 208 V, 60 Hz, 3 phase, L-L
1002 = 230 V, 60 Hz, 3 phase,L-L
1012 = 300 V, 60 Hz, 3 phase, L-L
1013 = 350 V, 60 Hz, 3 phase, L-L
1003 = 380 V, 50 Hz, 3 phase, L-L
1004 = 460 V, 60 Hz, 3 phase,L-L
1005 = 525 V, 60 Hz, 3 phase,L-L
1006 = 575 V, 60 Hz, 3 Phase, L-L
Mounting:
X = Flange
Blank - Stud
0
10
20
30
40
50
60
70
80
90
100
0123
Nominal Voltage
Drop Out Time Delay
11–22
900 Series
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
6 - 32 x 3/8 studs
4 places
1 3/4
2 5/16
2 3/4
3 5/32
2 1/8
2 11/16
Phase sequence relays are
designed to monitor the cor-
rect phase rotation of a
three phase system.
Several models are avail-
able from 50 Hz, 60 Hz, and
400 Hz with voltages up to
575 volts. High shock relay
output and reverse contacts
are also available.
Operation
The relay remains de-ener-
gized when voltage in the
proper phase sequence (A,
B, C) is applied, the relay is
energized when voltage
with incorrect sequence (A,
C, B) is applied.
Product Specifications
Input Voltage — See Ordering
Information
Output Contacts — SPDT
Contact Ratings
5 amp resistive at 120 Vac or 28 Vdc
Product Facts
nFunction 47
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Consult factory for additional
models.
Ordering Information
Sample Part Number 901X
Type:
900-3X = 120 VAC, 60 Hz, 3 phase,L-L
910X = 190-520 VAC, 60 Hz, 3 Phase, L-L
900-2X = 208-230, 50/60 Hz, 3 Phase
900X = 230 VAC, 60 Hz, 3 phase, L-L
901X = 460 VAC, 60 Hz, 3 phase,L-L
Mounting:
X = Flange
Blank - Stud
11–23
WCB Series
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Ordering Information
Sample Part Number WCB -120AC -1 -A
Type:
WCB = Current Balance
Control Voltage (± 15%)
26 DC
48 DC
125 AC
120 AC
230 AC
380 AC
460 AC
Trip Adjustment Range
.5 = 0.1 amp to 0.5 amps
1 = 0.2 amp to 1 amp
2 = 0.4 amp to 2 amp
Options:
A = two normally open contacts
B = two normally closed contacts
Current Balance Relays
are designed to sense
unbalanced current flow
in a three phase system.
The primary application of
Current Balance Relays is to
protect three phase motors
against phase unbalance or
phase failure.
Operation
With control voltage applied
to the relay, the output
contacts will energize when
the three phase currents
are balanced (including
zero currents), and will be
de-energize by unbalance
currents.
Product Specifications
Line Current — Three Phase,
AC current, 50-400 Hz Direct or from CT.
5 amp continuously
20 amp, 30 sec.
200 amp, 0.10 sec.
Control Voltage — See Ordering
Information
Unbalanced Trip Point
Screwdriver adjustable. Adjustment
range in accordance with ordering
information. (The unbalanced value is
defined as the difference between the
highest and the lowest phase current).
Drop-Out Time Delay
0.9 to 1.3 seconds
Surge Withstand Capability
In compliance with C37.90B ANSI/IEEE
Operating Temperature
-40°C to +70°C
Burden
Current input — 5.0 VA,
Phase Control voltage — 3.0 VA
Contact Ratings
One set, N.O., One set N.C.
5 amp resistive at 120 VAC or 28 VDC
Notes:
1. Remove black screw for access to
the trip adjustment.
2. Clockwise rotation of the adjust-
ment potentiometer will raise the
unbalance trip point.
3. The output contacts are shown
de-energized.
Product Facts
nFunction 60 or 87
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
R
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
11–24
WC1 & WCT1 Series, Overcurrent
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Ordering Information
Sample Part Number WCT1 -48DC -5 -B
Type:
WC1 = Per Time Curves
WCT1 = Adjustable Time Delay
Control Voltage (± 15%)
26 DC
48 DC
125 AC
120 AC
230 AC
380 AC
460 AC
Trip Adjustment Range
1 = .2 amp - 1 amp
5 = 1 amp to 5 amp
10 = 2 amp to 10 amp
Other Options
A = Two normally open contacts
B = Two normally closed contacts
11/64" DIA.
4 MTG. HOLES
3 1/2
3 7/8
2 3/4
3 1/2
3.0
TERMINAL STRIPS
#6 - 32 SCREWS
Current sensitive relays
are available for single and
three phase applications.
Voltage controlled overcur-
rent relays protect genera-
tors against fault currents
below the full rated value,
when the fault produces a
voltage drop as in the case
of short circuits or grounds.
Phase balance relays are
available to sense and
control unbalanced
current flow in three phase
systems. Current differen-
tial relays operate when the
differential between two
currents exceeds preset
values. Over/under current
phase-band relays are also
available.
Product Specifications
Line Current — Single Phase,
AC current, 50-400 Hz Direct or from CT
Control Voltage — See Ordering
Information
Trip Point — Screwdriver adjustable.
Adjustment range in accordance with
ordering information.
Pick-Up to Drop-Out Differential
Approximately 0.1 amp.
Overcurrent Allowance
Maximum of 500% for 0.25 seconds
Surge Withstand Capability
In compliance with C37.90B ANSI/IEEE
Operating Temperature
-40°C to +70°C
Temperature Drift — ± .05%
Burden
Current input — 1.2 VA,
Control voltage — 2.5 VA
Contact Ratings
One set, N.O., One set N.C.
5 amp resistive at 120 VAC or 28 VDC
Notes:
1. Remove black screws for access
to the current pick-up and the time
delay adjustment.
2. Clockwise rotation of the pick-up
adjustment will raise the current
trip point.
3. Clockwise rotation of the time
delay adjustment, (Type WCT1
only) will increase the time delay.
Product Facts
nFunction 50/51
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
R
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
See next page for
WCT Can Dimensions
Time Delay
Standard Time Delay
(WC1 Series) — A fixed inverse time
delay is incorporated in all overcurrent
relays and is represented by the typical
curves shown.
Adjustable Time Delay
(WCT1 Series) — The time delay is
field adjustable. The standard time delay
can be increased by any value between
0.5 and 20 seconds.
Typical Curves (WC1 Series)
0
2
4
6
8
00.10.20.30.4
Pick-Up Time Delay
Current (amps)
See next page for 3-phase types
and consult factory for additional
models.
11–25
WC3 & WCT3 Series, Overcurrent
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Ordering Information
Sample Part Number WCT3 -48DC -5 A
Type:
WC3 = Per Time Curves
WCT3 = Adjustable Time Delay
Control Voltage (± 15%)
26 DC
48 DC
125 DC
120 AC
230 AC
380 AC
460 AC
Trip Adjustment Range
1 = .2 amp - 1 amp
5 = 1 amp to 5 amp
10 = 2 amp to 10 amp
Other Options
A = Two normally open contacts
B = Two normally closed contacts
11/64" DIA.
4 MTG. HOLES
4.0
4 7/8
4 1/2
3 7/8
4 21/32
TERMINAL STRIPS
#6 - 32 SCREWS
4.0
3.0
Current sensitive relays
are available for single and
three phase applications.
Voltage controlled overcur-
rent relays protect genera-
tors against fault currents
below the full rated value,
when the fault produces a
voltage drop as in the case
of short circuits or grounds.
Phase balance relays are
available to sense and
control unbalanced current
flow in three phase systems.
Current differential relays
operate when the differen-
tial between two currents
exceeds preset values.
Over/under current
phase-band relays are
also available.
Product Specifications
Line Current — Three Phase,
AC current, 50-400 Hz Direct or from CT
Control Voltage — See Ordering
Information
Trip Point — Screwdriver adjustable.
Adjustment range in accordance with
ordering information.
Pick-Up to Drop-Out Differential
Approximately 0.1 amp
Overcurrent Allowance — Maximum
of 500% for 0.25 seconds
Surge Withstand Capability
In compliance with the requirements of
ANSI/IEEE
Operating Temperature
-40°C to +70°C
Temperature Drift — ± 0.05%/°C
Burden
Current input — 1.2 VA,
Control voltage — 2.5 VA
Contact Ratings
One set, N.O., One set N.C.
5 amp resistive at 120 VAC or 28VDC
Notes:
1. Remove black screws for access
to the current pick-up and the time
delay adjustment.
2. Clockwise rotation of the pick-up
adjustment will raise the current
trip point.
3. Clockwise rotation of the time
delay adjustment, (Type WCT3
only) will increase the time delay.
Product Facts
nFunction 50/51
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
R
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
See previous page for
WC Can Dimensions
Time Delay
Standard Time Delay
(WC3 Series) — A fixed inverse time
delay is incorporated in all overcurrent
relays and is represented by the typical
curves shown.
Adjustable Time Delay
(WCT3 Series) — The time delay is
field adjustable. The standard time delay
can be increased by any value between
0.5 and 20 seconds.
Typical Curves (WC3 Series)
0
2
4
6
8
00.10.20.30.4
Pick-Up Time Delay
Current (amps)
See previous page for 1-phase
models and consult factory for
additional models.
11–26
WCD Series
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Ordering Information
Sample Part Number WCD -230AC -1 -A
Type:
WCD - Close Differential
Control Voltage
120AC 25DC
208AC 48DC
230AC 125DC
380AC
416AC
460AC
525AC
575AC
Trip Adjustment Range
.5 = 0.1 amp to 0.5 amp
1 = 0.2 amp to 1 amp
2 = 0.4 amp to 2 amp
Options:
A = Two normally open contacts
B = Two normally closed contacts
H = Contacts rated 3 amp at 125 VDC
P = Transient protection is provided in compliance with
ANSI/IEEE C37.90-1978
.172 DIA.
4 MTG. HOLES
3
3 7/8
4 5/8
4
4 1/2
4 7/8
TERMINAL STRIPS
#6 - 32 SCREWS
Current Differential Relays
are used for the protection
of transformers, motors and
generators, by comparing
the magnitude of the current
entering and leaving the
protected circuit. On a
given phase winding, any
difference between the two
currents will indicate an
internal fault; the relay will
sense the vectorial differ-
ence between the two cur-
rents of the protected
section and will initiate a
quick disconnection of the
unit, to prevent disastrous
consequences.
The relay may also be used
to protect internal faults on
transformers, such as:
ground faults, shorted wind-
ing, leakage between pri-
mary and secondary, etc. It
will sense and compare pri-
mary vs. secondary cur-
rents, once the turns ratio
has been taken into consid-
eration.
Operation
With control voltage
applied, the output contacts
(shown in the de-energized
position) will remain de-
energized as long as the
difference between the two
input currents remains
below the preset trip value.
The contact will transfer to
the energized position when
the current difference
exceeds the trip value.
Product Specifications
Line Current
Single Phase, AC current, 50-400 Hz
Direct or from CT
5 amp continuously
20 amp 30 seconds
200 amp, 0.10 seconds
Control Voltage — See Ordering
Information
Differential Trip Point
Screwdriver adjustable. See Ordering
Information
Operating Temperature
-40°C to +75°C
Burden
Current input — 2.5 VA max.
Control voltage DC — 2 W max.
AC — 2 VA max.
Output Contacts
One set, N.O., One set N.C.
Contact Ratings
5 amp resistive at 120 VAC or 28 VDC
Notes:
1. Remove black screws for access
to the trip adjustments.
2. Clockwise rotation of the adjust-
ment potentiometer will raise the
current differential trip point.
3. The output contacts are shown
de-energized.
Product Facts
nFunction 87
nANSI/IEEE C37.90-1978
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Consult factory for additional
models.
11–27
1800 Series
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Consult factory for additional
models.
11/64" DIA.
4 MTG. HOLES
3
4
4 7/8
4 1/2
3 7/8
4 5/8
#6 - 32 STUDS
6 PLACES
Application
These relays are designed
for automatic paralleling
(synchronizing) of genera-
tors. The relays sense the
phase angle displacement
and the amplitude differ-
ence between two voltages
and permit paralleling only
when both voltages are
equal and in phase. A short
time delay is provided to
assure that the frequencies
are essentially the same at
the moment of paralleling.
The basic series is designed
to parallel two or more
energized AC generators.
The “Dead Bus” type
provides paralleling of AC
generators to the main bus.
They permit electrical con-
nection of an energized gen-
erator to an un-energized
line (Dead Bus). If the bus
is energized, connection of
the generator to the bus is
permitted only when both
are synchronized.
Product Specifications
Sensing Voltage — 120 V, 230 V,
277 V, 380 V, 460 V, 575 V, & 415 V
Line Frequency — 50-500 Hz
Pick-Up Adjustment
External adjustment for field sensing
of 10-30% of nominal input voltage.
(Vertical voltage differential of 6 to 18
electrical degrees).
Time Delay — Fixed @ 60 millisec-
onds is provided to assure that the fre-
quencies of both input lines are
sufficiently close to permit paralleling
within the preset window.
Output Contacts
One set N.O., one set N.C.
5 amp resistive at 120 VAC or 28 VDC
Product Facts
nFunction 25
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
R
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
A. 3 Phase, 4 Wire System
Connect phase "A" of LINE 1 to terminal 1
Connect phase "A" of LINE 2 to terminal 3
Connect the neutrals to terminals 2 & 4
B. 3 Phase, 3 Wire or 1 Phase, 2 Wire System
Connect phase "A" of LINE 1 to terminal 1
Connect phase "B" of LINE 1 to terminal 2
Connect phase "A" of LINE 2 to terminal 3
Connect phase "B" of LINE 2 to terminal 4
Selection Guide (Typical Applications)
Sensing Series 1800* Series 1800DB** Series 1800DDB***
Voltage Generator to Generator Generator to Bus Bus to Bus
120 Volts 1810X 1810DBX 1810DDBX
230 Volts 1820X 1820DBX 1820DDBX
380 Volts 1830X 1830DBX 1830DDBX
460 Volts 1840X 1840DBX 1840DDBX
575 Volts 1850X 1850DBX 1850DDBX
415 Volts 1860X 1860DBX 1860DDBX
277 Volts 1870X 1870DBX 1870DDBX
Condition Series 1800 Series 1800DB Series 1800DDB
Contacts Contacts Contacts
Energized Not Synch. N.C. N.O. N.C. N.O. N.C. N.O.
Energized
1Line 1 X Open Close Open Close Open Close
Line 2 X Yes
2Line 1 X No Close Open Close Open Close Open
Line 2 X No
3Line 1 X Close Open Open Close Open Close
Line 2 X
4Line 1 X Close Open Close Open Close Open
Line 2 X
5Line 1 X Close Open Close Open Open Close
Line 2 X
Output Contact Options
1. Two Form A. (Add -A to Model
Number)
2. Two Form B. (Add -B to Model
Number)
Notes
*Permits paralleling of two genera-
tors only when they are “on-line”
and their voltages are equal and
in phase (synchronized)
**Normally used to permit parallel-
ing of a generator to a bus when:
(a) both line voltages are equal
and in phase, or: (b) when the
generator is “on-line” and the bus
is “dead
***Permits paralleling of two power
lines (buses) when: (a) both line
voltages are equal and in phase,
or: (b) when either bus is “hot”
and the other bus is “dead”
11–28
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WOF & WUF Series
Ordering Information
Sample Part Number WUF -12 -5060 -T
Type:
WUF = Underfrequency
WOF = Overfrequency
Input Voltage (VAC)
12 = 120
23 = 230
38 = 380
46 = 460
Frequency Range
4050 = 40-50 HZ
5060 = 50-60 HZ
6070 = 60-70 HZ
3540 = 350-400 HZ
4045 = 400-450 HZ (overfrequency only)
Time Delay Options
blank = Per Time Curve
T = Adjustable
11/64" DIA.
4 HOLES
3 5/8
4 1/8
4 1/2
2 1/2
3 1/2
4 1/4
Application
The output contacts of fre-
quency relays are ener-
gized when the frequency
exceeds the adjustable set
point. Overfrequency and
underfrequency relays are
available in 50, 60 and
400Hz. Combination
over/underfrequency “band
pass” relays are also avail-
able. These are energized
at rated frequency and de-
energized during overfre-
quency or underfrequency
conditions. Frequency
Differential relays are ener-
gized above the preset fre-
quency. The pick-up and
drop-out frequency settings
are independently
adjustable.
Product Specifications
Nominal Voltage (±20%)
120, 230, 380 and 460 volts
Nominal Frequencies
50, 60 and 400 Hz.
Trip Point — Screwdriver adjustable.
Adjustment range in accordance with
ordering information.
Operating Temperature
-20°C to +65°C
Differential — The frequency pitch-up
to drop-out differential is .5% max
Voltage Drift — ± .05% maximum
frequency error for input voltage
variation of ±10%
Time Delay — See Time versus
Frequency curves
Surge Withstand Capability
In compliance with C37.90B ANSI/IEEE
Output Contacts — One set N.O., one
set N.C.
Contact Ratings
5 amp resistive at 120 VAC or 28VDC
Product Facts
nFunction 81 O/U
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
R
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Typical Curves (WOF Series)
60
65
70
75
80
85
90
0123456
Pick-Up Time Delay (sec)
Frequency (Hz)
Overfrequency Relay
Model WOF-12-6070
62 Hz. Setting
65 Hz. Setting
70 Hz. Setting
30
35
40
45
50
55
60
0123456
Typical Curves (WUF Series)
Drop-Out Time Delay (sec)
Frequency (Hz)
Underfrequency Relay
Model WUF-12-5060
50 Hz. Setting
55 Hz. Setting
58 Hz. Setting
Notes:
1. Remove black screws for access
to the frequency and the time
adjustments.
2. Clockwise rotation of the
frequency potentiometer will
raise the frequency trip point.
3. Clockwise rotation of the
time adjustment, option “T”
will increase the time for
overfrequency relays and dropout
time for underfrequency relays.
Time Delay
Standard Time Delay — A minimum,
fixed inverse time delay is incorporated
in all frequency relays to prevent
nuisance tripping and is represented by
the typical curves shown above.
Adjustable Time Delay
If additional time delay is required, a
suffix “T” must be added to the part
number. This allows the minimum fixed
time delay to be field-adjustable up to
20 seconds.
Consult factory for additional
models.
11–29
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WOUF Series, Over/Underfrequency
Ordering Information
Sample Part Number WOUF -12 -5060 -T
Type:
WOUF = Over/Underfrequency
Input Voltage (VAC)
12 = 120
23 = 230
38 = 380
46 = 460
Frequency Range
UF Adj. OF Adj.
50 = 40-50 Hz 50-60 Hz
60 = 50-60 Hz 60-70 Hz
400 = 350-400 Hz 400-450 Hz
Time Delay Options
blank = Per Time Curve
T = Adjustable
11/64" DIA.
4 MTG. HOLES
3 5/8
4 1/8
4 1/2
3
3 1/2
4 1/4
TERMINAL STRIPS
#6 - 32 SCREWS
The output contacts of
frequency relays are ener-
gized when the frequency
exceeds the adjustable set
point. Overfrequency and
underfrequency relays are
available in 50, 60 and
400Hz. Combination
over/underfrequency
“band pass” relays are
also available. These are
energized at rated fre-
quency and de-energized
during overfrequency or
underfrequency conditions.
Frequency Differential
relays are energized above
the preset frequency.
The pick-up and drop-out
frequency settings are
independently adjustable.
Operation
The relay will energize at
normal frequency; The
normally closed contacts
will open and the normally
open contacts will close.
The relay will drop-out after
time delay at overfrequency
or underfrequency.
Product Specifications
Nominal Voltage (±20%)
120, 230, 380 and 460 volts
Nominal Frequencies
50, 60 and 400 Hz.
Trip Point — Screwdriver adjustable.
Adjustment range in accordance with
ordering information.
Operating Temperature
-40°C to +65°C
Differential — The frequency pick-up
to drop-out differential is .5% max
Voltage Drift — ± 0.05% maximum
frequency error for input voltage varia-
tion of ±10%
Time Delay — See Time versus
Frequency curves
Surge Withstand Capability
In compliance with C37-90B ANSI/IEEE
Output Contacts — One set N.O., one
set N.C.
Contact Ratings
5 amp resistive at 120 VAC or 28 VDC
Notes:
1. Remove black screws for access
to the frequency and the time
adjustments.
2. Clockwise rotation of the
frequency potentiometer will
raise the frequency trip point.
3. Clockwise rotation of the time
adjustment, option “T” will
increase the drop-out time delay.
Product Facts
nFunction 81 O/U
nANSI/IEEE C37.90-1978
nUL File No. E58048
nCSA File No. LR61158
R
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Typical Curves (WOUF Series)
30
40
50
60
70
80
90
0123456
Drop-Out Time Delay
Frequency
Consult factory for additional
models.
Time Delay
Standard Time Delay — A minimum,
fixed inverse time delay is incorporated
in all frequency relays to prevent
nuisance tripping and is represented by
the typical curves shown below.
Adjustable Time Delay
If additional time delay is required, a
suffix “T” must be added to the part
number. This allows the minimum fixed
time delay to be field-adjustable up to
20 seconds.
11–30
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
20-000 Series
Ordering Information
Sample Part Number 20 -050 X
Type:
20 - Frequency
Frequency Range
040 = 40-50 Hz
050 = 50-60 Hz
060 = 60-70 Hz
350 = 350-500 Hz
400 = 400-450 Hz
Mounting Options
X = Flange
blank = Stud
11/64" DIA.
4 MTG. HOLES
3.0
3 1/2
3 7/8
3 13/16
4 1/2
#6 - 32 STUDS
6 PLACES
2 3/4
3 1/2
The output contacts of
frequency relays are ener-
gized when the frequency
exceeds the adjustable set
point. Overfrequency and
underfrequency relays are
available in 50, 60 and
400Hz. Combination
over/underfrequency “band
pass” relays are also avail-
able. These are energized
at rated frequency and
de-energized during
overfrequency or
underfrequency conditions.
Frequency Differential
relays are energized
between the preset
frequencies. The pick-up
and drop-out frequency
settings are independently
adjustable.
Operation
The normally open contacts
close, and the normally
closed contacts open, at
all frequencies above the
set point. The contacts in
the connection diagram, are
shown in the de-energized
position (below the trip set
point).
Product Specifications
Input Voltage (±10%)
120 VAC, Single Phase
Frequencies Range (adjustable)
See Ordering Information
Differential — Frequency pick-up to
drop-out differential is 1% max
Temperature Range
-40°C to +85°C
Temperature Drift — ± 1% frequency
error over temperature range
Voltage Error — ± 1% for input
voltage of 120 VAC ± 10%
Contact Ratings — 5 amp resistive at
120 VAC or 28 VDC
Output Contacts
One set N.O., one set N.C.
Notes:
1. Remove screw for access to trip
adjustment.
Product Facts
nFunction 81 O
R
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Consult factory for additional
models.
120VAC
11–31
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
25-000 Series
Ordering Information
Sample Part Number 25 -050 X
Type:
25 - Over/Underfrequency
Frequency Range
Under Over
050 = 40-50 Hz 50-60 Hz
060 = 50- 60 Hz 60-70Hz
400 = 350- 400 Hz 400-450Hz
Mounting Options
X = Flange
blank = Stud
11/64" DIA.
4 MTG. HOLES
3.0
3 1/2
3 7/8
3 13/16
4 1/2
#6 - 32 STUDS
6 PLACES
2 3/4
3 1/2
The output contacts of
frequency relays are ener-
gized when the frequency
exceeds the adjustable set
point. Overfrequency and
underfrequency relays are
available in 50, 60 and
400Hz. Combination
over/underfrequency
“band pass” relays are
also available. These are
energized at rated fre-
quency and de-energized
during overfrequency or
underfrequency conditions.
Frequency Differential
relays are energized above
the preset frequency.
The pick-up and drop-out
frequency settings are
independently adjustable.
Operation
The normally open contacts
close, and the normally
closed contacts open, at
nominal frequency. The
contacts are de-energize
at underfrequency,
overfrequency or no input
voltage.
Product Specifications
Input Voltage (±10%) — 120 VAC
Frequency Range (adjustable)
See Ordering Information
Trip Points — Screwdriver adjustable
Temperature Range
-20°C to +85°C
Temperature Drift — ± 1% frequency
error over temperature range
Voltage Drift — ± 1% frequency error
input voltage variation of ± 10%
Contact Ratings — 5 Amp resistive at
120 VAC or 28VDC
Output Contacts
One set N.O., One set N.C.
Notes:
1. The contacts are shown in the
de-energized position.
2. Remove screws for access to
the underfrequency and
overfrequency trip adjustments.
3. Clockwise rotation of the
adjustment potentiometer will
raise the frequency trip points.
Product Facts
nFunction 81 O/U
nANSI/IEEE C37.90-1978
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Consult factory for additional
models.
11–32
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
20-050-19 Series (Voltage/Frequency)
Ordering Information
Sample Part Number 20-050-19X
Type:
20-050-19 = Voltage/Frequency
Mounting Options
Blank = stud
X = Flange
Options:
P = Surge Suppression
11/64" DIA.
4 MTG. HOLES
3.0
3 1/2
3 13/16
4 1/2
2 3/4
3 1/2
#6 - 32 STUDS
6 PLACES
The output contacts of
frequency relays are ener-
gized when the frequency
exceeds the adjustable set
point. Overfrequency and
underfrequency relays are
available in 50, 60, and
400Hz. Combination
over/underfrequency
“band pass” relays are
also available. These are
energized at rated fre-
quency and de-energized
during overfrequency or
underfrequency conditions.
Frequency Differential
relays are energized above
the preset frequency.
The pick-up and drop-out
frequency settings are
independently adjustable.
Product Specifications
Nominal Voltage (±20%)
120 VAC, Single Phase
Nominal Frequency — 60 Hz.
Voltage Adjustment Range (PU)
85 to 120 VAC
Frequency Adjustment Range
(PU) — 45 to 60 Hz
Output Contacts
One set N.O., one set N.C.
Contact Ratings — 5 amp resistive at
120 VAC or 28 VDC
Notes:
1. Remove black screws for access
to the voltage and frequency and
the time adjustments.
2. Clockwise rotation of the voltage
adjustment potentiometer will
raise the voltage trip point.
3. Clockwise rotation of the
frequency adjustment will raise
the frequency time point.
Product Facts
nFunction 27/81
nANSI/IEEE C37.90-1978
nUL file No. E58048
nCSA file No. LR61158
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Consult factory for additional
models.
R
R
11–33
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WGD Series — Floating Ground
Ordering Information
Sample Part Number WGD-
Type: Volts L-L Trip Point Adj.
Phase to Ground
115-120AC 115 11-55K
120-120AC 120 12-60K
200-120AC 200 20-100K
208-120AC 208 21-105K
220-120AC 220 22-110K
230-120AC 230 23-115K
240-120AC 240 23-115K
380-120AC 380 38-190K
400-120AC 400 40-200K
416-120AC 416 42-210K
440-120AC 440 44-220K
460-120AC 460 46-230K
480-120AC 480 48-240K
525-120AC 525 52-260K
575-120AC 575 57-285K
600-120AC 600 60-300K
11/64" DIA.
4 MTG. HOLES
3 5/8
4 1/8
4 1/2
3.0
3 1/2
4 1/4
TERMINAL STRIPS
#6 - 32 SCREWS
Ground Fault Detectors
are used to sense leakage
current to ground in power
transformers and genera-
tors. They are available for
both AC and DC systems.
Some generator systems
provide auxiliary power
outlets for small equipment.
TE Connectivity GFD’s
eliminate personnel risk of
accessing these outlets if a
ground fault exists. Diesel
locomotives and railroad
line signal boxes also use
GFD’s for operational con-
trol purposes. The GFD
monitors both positive and
negative grounds for fault
currents and can trigger
either notification or system
shutdown if these are
detected. GFD’s are avail-
able for both grounded and
ungrounded systems.
Operation
When the resistance
between any phase to
ground falls below the set
point the relay will energize;
The normally closed con-
tacts will open, the normally
open contacts will close.
Product Specifications
Sensing Voltage (±10%)
3 phase, 3-wire. See Ordering
Information.
Control Voltage — 120 Volts AC
Contacts Trip Points (sensitivity)
Screwdriver adjustable. See Ordering
Information.
Pick-up Time Delay — 1.5 seconds
approximately
Contact Ratings — 5 amp resistive at
120 VAC or 28 VDC
Operating Temperature
-40°C to +65°C
Temperature Effects
± 1% over temperature range
Power Consumption
Sensing: —2 mA/Phase Approx.,
Control — 2VA at 120VAC
Surge Withstand Capability
In accordance with the requirements of
ANSI/IEEE
Notes:
1. Remove screw for access to the
pick-up adjustment potentiometer.
2. Clockwise rotation of the adjust-
ment potentiometer will raise the
relay sensitivity.
Product Facts
nANSI/IEEE C37.90-1978
nUL file No. E58048
nCSA file No. LR61158
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
R
R
11–34
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
WC1G Series — Grounded
Ordering Information
Sample Part Number WC1G-120AC
Model:
WC1G-
Control Voltage
120AC
220AC
230AC
380AC
400AC
460AC
480AC
575AC
11/64" DIA.
4 MTG. HOLES
33
11//22
3 5/8
4.125
4 1/2
3.0
3.8
3 1/2
4 1/4
TERMINAL STRIPS
#6 - 32 SCREWS
Ground Fault Detectors are
designed to provide very
sensitive Ground-Current
protection for motor, equip-
ment and personnel from
damage or electrical shock.
In a ground system, the
leakage current is moni-
tored through a toroidal or
doughnut current trans-
former placed around the
supply conductors to a
motor, transformer, equip-
ment or outlets. Since the
sums of the current in a sys-
tem add to zero, the relay is
responsive only to ground-
fault current.
Operation
The output contacts are
shown in de-energized
position. They will change
state when these conditions
are met:
1. Control voltage is
applied.
2. Leakage current exceed
the trip setting.
Product Specifications
CT Window Diameter — 1.7 inches
(std) or can be specified by customer
Leakage Current Range
10 to 60 mA
Control Voltage — See Ordering
Information
Output Contacts — One set N.C.,
one set N.O.
Operating Temperature
40°C to +65°C
Contact Ratings — 10 amp resistive
at 250 Vac, 8 amp. resistive @ 30 Vdc
Notes:
1. Remove screw for access to the
pick-up adjustment potentiometer.
2. Clockwise rotation of the adjust-
ment potentiometer will raise the
relay sensitivity.
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Current Transformer
11–35
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Additional Relays
OVERVOLTAGE RELAYS
AC, SINGLE PHASE, 50-400 HZ, SPECIALS
300X 120VAC
300HX 120VAC, Similar to 300X,with 125VDC 3A
Contacts
300S-1X 440VAC, 370-480V Range, Navy High Shock
300-2X 120VAC, Set at 132V, .010 Sec.Time Delay
300S-2X 120VAC, Navy High Shock
300-3X 190VAC, 180-280V Range
300-4X 190VAC, P.U. 264V, D.O. 261V
300-5X 240VAC, 230-360V Range
300-5KX 240VAC, Similar to 300-5X, except 1-10KHz
300-6X 230VAC, 230-300V Range
300-7X 450VAC, 375-475V Range
300-8X 120VAC, P.U. 130V, D.O. 125V
300-9X 120VAC, P.U. 132V, D.O. 126V
300-10X 120VAC, 99-132V Range
300-10HX 120VAC, Sim. to 300-10X, 125VDC 3A
Contacts
300-11X 120VAC, 0.5 Sec. Time Delay
300-12X 480VAC,480-600V Range
300-13X 120VAC, 2 N.O. Contacts
300-14X 95VAC, 95-120V Range
300-17X 120VAC, Similar to 300X with Spike
Suppression
300-18X 120VAC, Differential, 2V Max.
300-20X 10VAC, 8-12V Range, 120V Transient,
120VAC Ctrl.
300-21X 120VAC, 1.5-2.0 Sec. Time Delay
300-24X 277VAC, 140-320VAC Range
300-25X 24VAC, 24-30VAC Range
300-26X 120VAC, 90-150V Range
300-27X 120VAC, 105-135VAC Range
300-28X 10VAC, 8-12VAC , 220VAC Transient,
120VAC Ctrl.
300-29X 120VAC, 150-180V Range
300-30X 120VAC, 375V Max., 24VDC Control
300-32X 120VAC, 135-180V Range, 1.5 Sec. Time
Delay
300-33X 115/230VAC, DPDT Contacts 230VAC 1A
300-34X 100VAC, 1.5-2.0 Sec. T.D., 100-120V Range
300-35X 480VAC, 1.5-2.0 Sec. T.D., 480-600V Range
300-36X 138VAC, 138-172V Range
300-37X 350VAC, 350-450V Range, 2.0 Sec. T.D., Supp.
300-38X 120VAC, 99-132V Range, 125VDC 1A
Contacts
300-39X 120VAC, 120-150V Range, 0.3-3.0 Adj. T.D.
300-40X 230VAC, 220-300V Range, 2.0 Sec. T.D.
300-41X 120VAC, 120-165V Range, 1.5 Sec. T.D., Supp.
300-42X 120VAC, Similar to 300-39X, but 2 N.O.
Contacts
300-43X 120/240VAC, 140-180V Range, Phase
Protection
300-44X 277VAC, 277-350V Range
300-45X 30/60VAC, 277V Continuous, 115VAC Control
300-46X 67VAC, 67-120V Range
300-47X 360VAC, 10-64V Range, 0.75-7.5 Sec. T.D.
300-48X 10VAC, 8-21V, 220VAC Transient, 125VDC Ctrl.
300-49X 120VAC, Similar to WOV-1-120,
but 0.2 Sec. T.D.
300-50X 120/240VAC, Highest of 2, 0.5-10 Sec. T.D.
300-51X 30/60VAC, 400V Max. Contin., 120V 60Hz Ctrl.
300-52X 208VAC, 208-291V, 24VDC Ctrl., 1 N.O.
Contact
300-53X 200-480VAC, 200-240V Range
300DC-1X 28VDC, Set at 30V, Curve 1 MIL-STD-704
AC, SINGLE PHASE, 400 HZ
302X 120VAC
302-SX 120VAC, A.E.I. . Special
302-1X 120VAC, 0.3 Sec. T.D.
302-2X 120VAC, 125-175V Range
302-3X 120VAC, 125-150V Range with T.D.
302-4X 120VAC, 125-150V Range, 0.3 Sec. T.D.
AC, THREE PHASE, 50-400 HZ, SPECIALS
301X 120/208VAC4W
301-SX 120/208VAC, 4W, Similar to WOV-3-208 with
hi-shock
301-HX 120/208VAC, 4W, 125VDC 3A Contacts
301-1X 240VAC, 4W, 240-330V Range
301-2X 220/380VAC, 4W
301-3X 254/440VAC, 4W, 440-605V Range
301-3HX 277/480VAC, 4W, 125VDC 3A Contacts
301-4X 127/220VAC, 4W, 220-275V Range
301-4HX 120/208VAC, 4W, 125VDC 3A Contacts
301-5X 380VAC, 4W, 370-460V Range
301-6X 380VAC, 4W, 375-528V Range
301-7X 120/208VAC, 4W, 0.022 Sec. T.D.
301-8X 120VAC. 3W, 120-150VAC
301-9X 240VAC, 3W, 240-300V Range
301-11X 120/208VAC, Similar to 301-7X
301-12X 440VAC, 3W
301-13SX 120/208VAC, 4W, Hi-Shock, T.D., Solar
301-15X 120/208VAC, 4W, 140-180V Range
301-16X 254/440VAC, 4W, Sim to 301-3, but 3 XFMS
301-17SX 120VAC, 3W, Sim to 301-13SX except 120V
301-18X 277/480VAC,4W,3 independent adjustments
301-19SX 94VAC, 3W, Similar to 301-17SX
301-20SX 86/150VAC, 4W, 90-120V Range, T.D., Solar
301-21X 460VAC, 3W, 125VDC Contacts
301-22X 277/480VAC, 4W, 323-425V Range (L-N)
301-23X 380VAC, 3 or 4W, 0.022 Sec. T.D.
301-25X 120/208V, 4W, 2-3 Sec. T.D.
301-26X 416VAC, 3 or 4W, 415-520V Range
301-27X 277/480VAC, 4W, 2-3 Sec. T.D.
301-28X 20.8VAC, 3W, 20-25V Range
301-29X 480VAC, 3 or 4W, Sim. to 301-3X with
spike supp.
301-30SX 100VAC, 3W, 100-125V Range, hi-shock
301-31X 208-240, 3W, 200-280V Range, 45-65 Hz.
301-32X 400VAC, 3W, 400-500V Range
301-34X 208VAC, 3W, Set 240V, Withstand 600V contin.
301-35X 120VAC, 3W, 3-5 Sec. T.D.
301-37X 120VAC, 3W, Sim. to 301-8X with
spike suppression
301-39X 138/240VAC, 3 or 4W, 2 Sec. T.D.
301-40X 120/208VAC, 4W, Highest of 3, Solar
301-41SX 450VAC, 3W, Navy Hi-Shock,
75VDC 3A Contacts
301-42X 120VAC, 3W, Highest of 3, 120-150V Range
301-45X 120/208VAC, 4W, Highest of 3, Adj. T.D.
301-46X 104VAC, 3W, Similar to WOV-3-104
11–36
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Additional Relays (Continued)
301-47X 69/120VAC, 4W, 69-90V Range, 120V (L-N)
Contin.
301-48X 380VAC, 3 or 4W, 380-500V Range
301-49X 250VAC, Withstand 520VAC Continuous
301-50X 180VAC, 3W, Similar to WOV-3-180
301-51X 120VAC, 3W, Supp, 10CFR Class1E (Nuclear)
301-52X 95VAC, 3W, 95-120V (L-L) Range
301-53X 115/200VAC, Similar to WOV-3-200,
1.0 Sec T.D.
AC, THREE PHASE, 400 HZ
303X 120/208VAC, 4W
303-1X 115/200VAC, 4W, Highest of 3, T.D.,
MIL-E-7894
303-1SX 115/200VAC, 3W, High Shock
303-2X 120/208VAC, 4W, High of 3, T.D., MIL-E-7894
303-3X 120/208VAC, Highest of 3, T.D.
303-4X 120VAC, 3W, 120-160V Range
303-8X 254/440VAC, 4W
303-9X 240/416VAC, 4W
303-10X 120/208VAC, 4W, 168V P.U., Kato
303-12X 120/208VAC, 4W, Fast Operating
303-13X 120/208VAC, 4W, 0 deg. C to 90 deg. C
303-15X 120/208VAC, Sim. to 303-13X with
Latching Circuit
303-16X 120/208VAC, 303X with conformal coating
DC
310DCX 28VDC, 28-36V Range
310DC-HX 28VDC, 28-36V Range, 125VDC 2A Contacts
310DC-SX 28VDC, 28-36V Range, 2A Contacts,
High Shock
310DC-2X 28VDC, 28-36V Range, T.D., MIL-E-7894 Fig. 2
310DC-3X 28VDC, 35-46V Range, T.D., MIL-E-7894
310DC-4X 28VDC, Set 31V, 2 Sec; 40V, 0.2 Sec.
311DCX 12VDC, 12-16V Range
311DC-1X 12VDC, 12-16V Range, 1V Differential
320DCX 60VDC, 60-85V Range
320DC-HX 60VDC, 60-85V Range, 125VDC 2A Contacts
320DC-1X 35-60VDC, Spike Suppression
320DC-2X 55-80VDC, Spike Suppression
320DC-4X 48VDC, 48-70V Range
320DC-5X 20-70VDC, 120VAC Control
330DCX 120VDC, 120-160V Range
330DC-HX 120VDC, 120-160V Range,
125VDC 2A Contacts
330DC-1X 120VDC, 110-150V Range
330DC-2X 120VDC, 150-190V Range
340DCX 240VDC, 240-300V Range
340DC-HX 240VDC, 240-300V Range,
125VDC 2A Contacts
340DC-1SX 200VDC, 240-300V Range, Non-Mag.,
High Shock
350DCX 305VDC, 280-400V Range
350DC-HX 305VDC, 280-400V Range,
125VDC 2A Contacts
350DC-1SX 250VDC, 280-400V Range, Hi-Shock,
120VAC Control
360DCX 405VDC, 400-470V Range
360DC-HX 405VDC, 400-470V Range,
125VDC 2A Contacts
360DC-1X 405VDC, 400-470V Range, Spike
Suppression
360DC-2X 475VDC, 475-550V Range
360DC-3X 550VDC, 550-600V Range
360DC-4X 350VDC, 350-440V Range, Bi-Directional
360DC-4HX 350VDC, 350-440V Range, Bi-Directional
370DCX 620VDC, 600-670V Range
370DC-2X 550VDC, 550-650V Range
370DC-1X 610VDC, 600-800V Range, 120VAC Control
370DC-3X 610VDC, 800-1000VDC Range
370DC-5X 960VDC, 900-1000VDC Range
AC, SINGLE PHASE, 50/60 HZ, SPECIALS
400X 120VAC
400HX 120VAC, Sim. to 400X with
125VDC 3A Contacts
400SX 120VAC, Hi-Shock, 10A Contacts
400-1X 120VAC, 55-72V Range
400-1HX 120VAC, Sim. to 400-1X,
125VDC 3A Contacts
400-S-1 450VAC, 240-350V Range, Hi-Shock, T.D.
400-2X 120VAC, 0.017 Sec. T.D.
400-S-2 440VAC, 280-420V Range, Hi-Shock, T.D.
400-3X 120VAC, 4.8 Sec. T.D., 80-115V Range
400-S-3 440VAC, 280-420V Range, Hi-Shock, T.D.
400-4X 240VAC, 170-240V Range
400-S-4 440VAC, Sim. to 400-2SX, 2-3 Sec. T.D.,
D.O. 160V
400-5X 450VAC, 320-450V Range
400-5SX 450VAC, 70-100% Range, Hi-Shock,
10A Contacts
400-6X 120VAC, 90-123V Range
400-7X 277VAC, 190-290V Range
400-8X 120VAC, 55-80V Range
400-8SX 120VAC, 50-70% Range, Hi-Shock
400-9X 480VAC, 320-480V Range
400-10X 120VAC, 1.0 Sec. T.D. with power loss
400-11X 480VAC, 1.0 Sec. T.D., 320-480V Range
400-12X 120VAC, Similar to 400-10X except 1 N.O.
& 1 N.C.
400-13X 120VAC, 14-30V Range
400-14X 67VAC, 30-67V Range, Suppression
400-16X 120VAC, 0.6 Sec. T.D., 50-420 Hz
400-17X 120VAC, Similar to 400-2 with seismic
400-19X 120VAC, 125VDC 2A Contacts, Suppression
400-20X 208VAC, 24-48V Range
400-21X 120VAC, 94.8-102V Range, 6 +/-2 Sec. T.D.
400-23X 480VAC, 320-480V Range, 2.0 Sec. T.D.
400-24X 120VAC, 2.0 Sec. T.D.
400-25X 240/480VAC, 3-30Sec. T.D., Latching
400-26X 480VAC, 160-200V Range
400-27X 460VAC, 250-350V Range, 0.3 Sec. T.D.,
Set to 76V
400-28X 0.5VAC, 0.5-1.0V Range, 115VAC Control
400-29X 120VAC, 0.15 Sec. T.D., 10A Contacts
400-30X 24VAC, 18-24VAC Adjustable
400-31X 120VAC, 105-135V Range
400-32X 120VAC, 1 Ph. T.D. 0-10 Sec.
400-33X 480VAC, 1 Ph. T.D., 0-10Sec.
400-34X 120VAC, 55-72V Range, 2 N.O. Contacts
400-35X 120VAC, Similar to 400X, but 2 N.C. Contacts
11–37
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Additional Relays (Continued)
400-36X 120VAC, Similar to 400-24X, 1 N.O.,
1 N.C. Contact
400-37X 120VAC, Similar to 400X, with Suppression
400-38X 120VAC, 85-120V, 1-20 Sec. T.D.,
Instant. at 50V
400-38PX 120VAC, Similar to 400-38X with Spike
Protection
400-39X 120VAC, 1.0 Sec. T.D., Transient Protection
400-40X 120VAC, 0.083 Sec. T.D.
400-41X 120VAC, Similar to 400X with 2 N.O. Contacts
400-43X 240VAC, 120-240V Range
400-44X 208VAC, 150-210V Range
400-47X 380VAC, Fast Operating, 220VAC 5A Contacts
400-49X 120VAC, 55-80V Range, 125VDC Contacts
400-50X 480VAC, 320-480V Range,
125VDC 1A Contacts
400-51X 120VAC, Sim. to 400-38X with 1-30 Sec. T.D.
400-52X 120VAC, 55-80V Range, 125VDC 2A Contacts
400-53SX 450VAC, 110-300V Range, 120V Control
400-54X 120VAC, Sim. to 400-13X with 1.0 Sec. T.D.
400-55X 208VAC, 125-208V, 24VDC Ctrl.,
1 N.O. Contact
400-56X 208VAC, 24-48V Range, 2 N.O. Contacts
400-57X 120VAC, 25 Hz, 84-120V,
125VDC 3A Contacts
400-58X 277VAC, 194-277V Range, 0.020 Sec. T.D.
400-59X 139VAC, 97-159V Range
400-60X 240VAC, 84-120V Range
400-6lPX 120VAC, Similar to WUV-1-120P
400-62X 120VAC,30-42V Range, 125VDC Contacts
400-63X 120VAC,30-42V Range, 120VAC Contacts
AC, SINGLE PHASE, 400 HZ
402X 120VAC
402-SX 120VAC, Hi-Shock, NSN 5945-00-258-6662
402-1X 240VAC, 170-240V Range
402-1SX 240VAC, High Shock
402-2X 120VAC, 90-120V Range, 0.3 Sec. T.D.,
Set to 96V
402-3X 120VAC, Similar to 402-2X with 10A Contact
402-4X 120VAC, Similar to 402-2X with 0.15 Sec. T.D.
AC & DC, SINGLE PHASE, CLOSE DIFFERENTIAL
D100-10X 120VAC, 50-500Hz, -40 to +75 deg. C
D100-13X 450VAC, D.O. 60-100%, P.U. 66-100%
D100-15X 120VAC, 50-500Hz, 125VDC, 1 Amp Contacts
D100-16X 208VAC, 50-500Hz, 125VDC, 1 Amp Contacts
D100-17X 120VAC, 50-500Hz, 450VAC Input Capacitor,
GE
D100-18X 120VAC, Hi-Shock, D.O. 72-84,
P.U. 102-114 Range
D100-19X 120VAC, Hi-Shock, D.O. 80-120,
P.U. 80-120 Range
D100-20X 150VAC, 105-150V Range
D100DCX 60 VDC, 48-55VDC Range, 1.5 Sec. T.D.
D100DC-15X 120VDC, 80-120VDC Adjust,0.4V Differential
D100DC-16X 60VDC, 40-60VDC Adjust, 0.2V Differential
D100DC-18X 40VDC, 20-40VDC Adjust, 120VAC Control
D100DC-19X 140VDC, 100-140VDC, 0.4V Differential
D100DC-22HX 120VDC, 80-120VDC Range,
120VDC Contacts
D100DC-23X 260VDC, 195-260VDC Range
D100DC-35X 30-40VDC Range, Plug-in,
NSN 5945-00-650-8613
D100DC-36X 48VDC, Adjustable 38-48VDC
D100DC-37X 75VDC, 50-80VDC Range, 0.5A,
74VDC Contacts
D100DC-38X 270VDC, 190-270VDC Range, Similar to
D100DC-23
D100DC-39X 28VDC, Adjustable 15-30VDC
D100DC-40X 28VDC, Approx. 2.0 Sec T.D.
AC, THREE PHASE, 50/60 HZ, SPECIALS
401X 120/208VAC, 4W, 85-120V Range
401-HX 120/208VAC, 4W, 125VDC 3A Contacts
401-1X 240VAC, 4W, 182-244V Range (L-L)
401-2X 480VAC, 4W, 360-485V Range (L-L)
401-2HX 480VAC, 3 or 4W, 125VDC 3A Contacts
401-3X 220VAC, 3W, 160-200V Range (L-L)
401-4X 380VAC, 4W, 150-220V Range (L-N)
401-5X 120VAC, 4W, 90-120V Range (L-L)
401-6X 120VAC, 3W, 85-120V Range (L-L)
401-7X 480VAC, 4W, 332-407V Range (L-L)
401-8X 100VAC, 3W, 70-100V Range (L-L)
401-9X 120/208VAC, 4W, Fast Operating
401-9HX 120/208VAC, 4W, 0.02S T.D., 125VDC 3A
Cont.
401-10X 480VAC, 3W, 360-485V Range
401-10HX 480VAC, 3W, 125VDC 3A Contacts
401-11X 240VAC, 3W, 180-240V Range
401-11HX 240VAC, 3W, 125VDC 3A Contacts
401-12X 120/208VAC, 4W, 1.0 Sec. T.D.
401-12HX 120/208VAC, 4W, 1.0 Sec. T.D.,
125VDC 3A Contacts
401-13X 380VAC, 3W, 1.0 Sec. T.D.
401-14X 480VAC, 4W, 0.5 Sec. T.D.
401-15X 120/208VAC, Sim. to 401X with 6" leads
and socket
401-16X 380VAC, Sim. to 401-4X with 6" leads
and socket
401-17SX 120/208VAC, 4W, 10 Sec. T.D., Solar
401-18X 480VAC, 3W, 2.0 Sec. T.D., 90% P.U., 70% D.O.
401-19X 120/208VAC, Sim. to 401X with 2KV Diodes,
Supp.
401-20X 69/120VAC, 4W, 25-35V Range, 4KV Diodes,
Supp.
401-21X 120/208VAC, 4W, 85-120V Range,
0.05 Sec. T.D.
401-22X 480VAC, 3 or 4W, 5.0 Sec. T.D.
401-23X 120VAC, 3W, 0.05 Sec. T.D.
401-24X 120VAC, 3W, 2 N.C. Contacts
401-25SX 120VAC, 3W, 10Sec. T.D., Solar
401-26X 67/115VAC, 4W, Suppression
401-28X 120/208VAC, 4W, 60-100V Range, Set at 90V
401-29X 120VAC, 4W, 90-120V Range, 1.0 Sec. T.D.
401-29HX 69/120VAC, 4W, 1.0 Sec. T.D.,
125VDC 3A Contacts
401-30X 480VAC, 3W, 360-480V Range, 2.0 Sec. T.D.
125VDC 3A Contacts
401-31SX 94VAC, 3W, 10 Sec. T.D., Solar
401-33X 480VAC, 4W, 139-231V Range (L-N)
401-34X 120/208VAC, 4W, 2-3 Sec. T.D.
401-35X 208VAC, 3W, 0.008 Sec. T.D., 28VDC Control
401-36X 480VAC, 3W, 0.008 Sec. T.D., 28VDC Control
11–38
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Additional Relays (Continued)
401-37X 120VAC, 3W, 5.0 Sec. T.D.
401-38X 380VAC, 3W, 0.05 Sec. T.D.
401-39X 480VAC, 4W, 250-550V Range (L-L)
401-41X 240/416VAC, 4W, 312-416V Range (L-L)
401-41HX 230/400VAC, 4W, 125VDC 3A Contacts
401-42X 120/208VAC, 4W, 5.0 Sec. T.D.
401-43SX 480VAC, Sim. to 403-7SX except 60 Hz.
401-44X 139/240VAC, 4W, 2.0 Sec. T.D.
401-45X 120VAC, 3W, 85-120V Range (L-L),
125VDC Contacts
401-46X 480VAC, Similar to 401-2X with Suppression
401-47X 380VAC, 3W, 2.0 Sec. T.D.
401-48X 208VAC, 3W, 145-208V Range
401-49X 20.8VAC, 3W, 15.5-20.8V Range
401-50X 120VAC, 3W, 0-10 Sec. T.D.
401-51SX 90/156 VAC, 4W, Similar to 401-17SX
401-52X 480VAC, 3W, Sim. to 401-10X
401-53X 120/208VAC, 4W, 1 N.O., 1 N.C.
401-54X 400VAC, 3W, 300-400V Range
401-55X 600VAC, 3W, 480-600V Range
401-58X 120/208VAC, Sim. to 401X except
2 N.C. Contacts
401-59X 220-380VAC, Dual Voltage 220V or 380V
401-60X 480VAC, 1 N.O., 1 N.C. Contact, 2-3 Sec. T.D.
401-61X 120VAC, 3W, 85-120V Range (L-L),
1.0 Sec. T.D.
401-62X 380VAC, 3W, 220VAC 5A Contacts
401-63X 120VAC, 3W, Sim. to 401-6X with Suppression
401-67X 120/208VAC, 4W, 1.0 Sec. T.D., -55F to +150F
401-68X 120VAC, 3W, 85-120V Range, 2-3 Sec. T.D.
401-69X 120/208VAC, 4W, 85-120V Range, Lowest of 3
401-70X 133/230VAC, 4W, 99-133V Range, Lowest of 3
401-71X 220/380VAC, 4W, 154-220V Range, Lowest of 3
401-72X 266/460VAC, 4W, 186-266V Range, Lowest of 3
401-74X 66/115VAC, 4W, 65-75% Adj., Supp.,
125VDC Cont.
401-75X 115/200VAC, 3W, 65-75% Adj., Suppression
401-76SX 450VAC, 3W, 382-450V, 0.3-0.5S T.D.,
Hi-Shock
401-77X 120/208VAC, 4W, 0.5-10 Sec. T.D., Lowest of 3
401-79X 480VAC, 3W, 0.2-0.3 Sec. T.D., Suppression
401-80X 76VAC, 3W, 53-76V Range
401-81X 120/208VAC, Sim. to 401-12X with
48VDC Contacts
401-82X 104VAC, 3W, Similar to WUV-3-104
401-83SX 120/208VAC, MIL-R-2033A
401-84X 180VAC, 3W, Similar to WUV-3-180
401-85SX 480VAC, Similar to 401-25SX except 480V
401-86SX 380VAC, Similar to 401-25SX except 380V
401-87SX 240VAC, Similar to 401-25SX except 240V
401-90X 120/208VAC, 4W, 0.5 Sec. T.D.
401-93X 480VAC, 3W Fast Oper. 50mS., Suppression
401-97X 69/120VAC, Lowest of 3
401-98X 480VAC, Sim. to 401TD-9HX with 2.0 Sec. T.D.
AC, THREE PHASE, 400 HZ
403X 120/208VAC, 4W
403-1X 115/200VAC, 4W, 35-400mS T.D.
403-1SX 115VAC, 3W, Hi-Shock
403-2X 120VAC, 3W
403-3X 120/208VAC, 4W, 1.0 Sec. T.D.
403-4X 254/440VAC, 4W
403-5X 120/208VAC, 4W, 2 N.C. Contacts
403-7SX 480VAC, 3W, T.D., Hi-Shock
403-10X 120/208VAC, 4W, 10A Contacts
403-11X 480VAC, 4W, 60% to 80% Range
403-13X 120/208VAC, 4W, 0C to +90C
403-14X 575VAC, 3W, 400-500V Range
403-15X 120/208VAC, Sim. to 403-13X with
Latching Circuit
403-16X 120/208VAC, Sim. to 403X with Conformal
Coating
AC THREE PHASE, CLOSE DIFFERENTIAL
D101-3X Similar to D101X, -55C to +85C
D101-5X 120VAC, 50-500Hz, Military
D101-9X 120VAC, 50-500Hz, 0.5 Sec T.D.
D101-11X 120VAC, 50-500Hz, 120-150VAC Adjust,
N.C. Cont.
D101-12X 120VAC, Similar to D101X but
60-120VAC Range
D101-13X 120VAC, Similar to D101X but
3 N.C. Contacts
D101-14X 208VAC, Similar to D101-6X but
3 N.C. Contacts
D101-15X 480VAC, 50-500Hz, Spike Suppressors
D101-16X 480VAC, Similar to D101-7X but
3 N.C. Contacts
D101-17X 120VAC, 0.4A 120VDC Contact,
-20 to +85 deg C
D101-18X 120VAC, Similar to D101X but
Spike Suppression
D101-19X 208VAC, Similar to D101-6X but
Spike Suppression
D101-20X 240VAC, Similar to D101-4X but
Spike Suppression
D101-21X 380VAC, Similar to D101-10X but
Spike Suppression
D101-24X 240VAC, 3 N.C. Contacts
D101-25X 208VAC, 3 N.C. Contacts, Spike Suppression
D101-26X 277VAC, 50-500Hz, 66-100% Adjustable
D101-27X 120VAC, Sim. to D101X, withstand
208V continuous
D101-29X 415VAC, 50-500Hz
D101-30X 380VAC, 50-500Hz, 3 N.C. Contacts
D101-31X 525VAC, Spike Suppression
D101-32X 120VAC, 50-500Hz, 5 Sec T.D.
DC
400DCX 120VDC, 85-120V Range
400DC-HX 120VDC, 85-120V Range,
125VDC 2A Contacts
400DC-lX 28VDC, 15-29V Range
400DC-2X 240VDC, 180-220V Range
400DC-3X 62.5VDC, 40-65V Range
400DC-4X 305VDC, 200-300V Range
400DC-5X 5.6VDC, 4-6V Range, 120VAC Cont
410DCX 28VDC, 16—29V Range
410DC-SX 28VDC, 16-29V Range, Hi-Shock, MIL-R-57
410DC-1X 28VDC, 15-32V Range, 1.5V Differential
410DC-5X 24VDC, 16-29V Range, Suppression
410DCTDX 28VDC, 0.5-20 Sec. T.D.
411DCX 12VDC, 9-12 V Range
411DC-1X 15VDC, 11-15V Range
411DCTDX 12VDC, 0.5-20 Sec. T.D.
420DCX 60VDC, 40-65V Range
11–39
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Additional Relays (Continued)
420DC-4X 48VDC, 32-48V Range
420DC-5X 48VDC, 20-48V Range
420DC-6X 70VDC, 50-70V Range
420DC-8X 32VDC, 33-40V Range (Pick-Up)
420DC-9X 48VDC, Similar to 420DC-4X with 2 N.O.
Contacts
420-470 SUFFIX SUFFIX : “A” 2 N.O. Contacts
“B” 2 N.C. Contacts
430DCX 120VDC, 85-120V Range
430DC-HX 120VDC, 85-120V Range,
125VDC 3A Contacts
430DC-1X 140VDC, 105-140V Range
430DC-2X 140VDC, 105-140V Range, 0.5 Sec. T.D.,
Suppression
430DC-3X 120VDC, 50-80V Range
430DC-4X 120VDC, 85-120V Range, 0.5 Sec. T.D.,
Set at 90V
430DC-5X 125VDC, 90-125V Range, Spike Suppression
430DC-6X 125VDC, 105-140V Range, 3.0-5.0 Sec. T.D.
430DC-7X 170VDC, 120-170V Range
430DC-8X 120VDC, 85-120V Range, 2 N.C. Contacts
430DC-9X 100VDC, 35-50V Range
430DC-10X 120VDC, 85-120V Range, 2 N.O. Contacts
440DCX 240VDC, 168-240V Range
440DC-HX 240VDC, 168-240V Range,
125VDC 3A Contacts
440DC-1X 280VDC, 190-260V Range
450DCX 305VDC, 230-305V Range
450DC-HX 305VDC, 230-305V Range,
125VDC 3A Contacts
450DC-1X 305VDC, 230-305V Range,
2 N.C. Contacts
460DCX 405VDC, 315-415V Range
460DC-HX 405VDC, 315-415V Range,
125VDC 3A Contacts
460DC-1X 405VDC, 300-330V Range
460DC-3X 405VDC, 300-425V Range
460DC-4X 432VDC, 275-325V Range
460DC-5X 470VDC, 300-425V Range
470DC 560VDC, 400-500V Range
470DC-1X 585VDC, 400-500V Range
DC TIME DELAY
420DCTDX 48VDC, 32-48V Range, 0.5-20 Sec. T.D.
430DCTDX 125VDC, 83-125V Range, 0.5-20 Sec. T.D.
440DCTDX 250VDC, 166-250V Range, 0.5-20 Sec. T.D.
OVER/UNDERVOLTAGE RELAYS
AC, SINGLE PHASE
250SX 120VAC, Hi-Shock
250-1X 120VAC, 72-120V, Mil,
NSN 6125-00-091-0969
250-2X 120VAC, 1.2 Sec. Time Delay
250-3X 67VAC, UV 30-67V, OV 67-91V
250-4X 26VAC, 28VDC Control, Connector
250-5X 240VAC, Two N.C. Contacts
250-6X 240VAC, One N.O., One N.C. Contact
250-6HX 240VAC, 120VDC, 3A Contact
250-7X 120VAC, 3 Sec. Time Delay
250-8X 100VAC
250-10X 120VAC, Fast Trip, 25mS
250-11X 120VAC, Set at 97V and 156V
250-12X 120VAC, Sim. to 250X, MIL-R-5757 2A
250-14XAC 67VAC, Sim. to 250-3X with removable cover
250-17X 120VAC, Sim. to 250X plus suppression
250-19X 120VAC, Sim. to 250X with 2 N.O. Contacts
250-22X 240VAC, 1-2 Sec. TD on Drop Out
250-23X 120VAC, Sim. to 250X but -40C to +52C
250-27X 139VAC, Same as 250-12X except voltage
250-28X 138VAC, Same as 250-10X except voltage
250-29HX 120VAC, 50-400Hz., 125VDC 3A Contacts
250-30X 480VAC
250-31X 240VAC, Fast Trip 25mS
250-32HX 480VAC, 100Hz, 1Sec TD,
120V 3ADC Contacts
250-33HX 480VAC, 25Hz, 1 Sex TD,
120V 3ADC Contacts
250-34X 120VAC, 72-120-160V Range, Hi Shock
250-35X 230VAC, Sim. to 250-22X, 3.0 Sec. TD
250-36X 120VAC, 84-120-150V Range, Hi Shock,
-40C to 70C
250-37HX 120VAC, 25 Hz, 1 Sec. TD,
120V 3ADC Contacts
250-38X 240VAC, Two N.O. Contacts
250-39X 120VAC, Similar to 250X, Range +/- 35%
AC, SINGLE PHASE, 50-400HZ
251SX 120/208VAC, Sim. to 251X with Hi Shock
251-1X 120/208VAC, 4W, 0.50 Sec. TD
NSN 5895-00-139-0337
251-4X 139/240VAC, 4W
251-5X 120/208VAC, 4W, Two N.C. Contacts
251-8X 120/208VAC, 4W, 1.2 Sec. TD
251-10X 110/190VAC, 4W
251-13X 120/208VAC, Sim. to 251X except -40C to 52C
251-14X 120/208VAC, 4W, Withstand 220/380V
Continuous
251-15X 120/208VAC, Sim. to 251X with Transient
Protection
251-16X 120/208VAC, 1.2 Sec. TD, Transient Protection
251-17X 120/208VAC, Similar to 251X,
208V 7.5A Contacts
251-18X 120/208VAC, Highest/Lowest of three,
TD Adjust 12VDC control
251-19X 120/208VAC, Highest/Lowest of three,
TD Adjust 120VAC control
251-20X 120/208VAC, Highest/Lowest of three,
TD Adjust, 24VDC Control
251-21X 120/208VAC, Sim. to 251X, 0.5Sec. TD
251-22X 115/200VAC, Sim. to 251X, 0.75Sec. TD
253-HX 230VAC, 3W, 48VDC 3A Contacts
253-1X 230VAC, 3W, Spike Suppression
253-1HX 230VAC, 3W, Spike Suppression,
125VDC Contacts
253-3X 230VAC, 3W, 1.0 Sec. TD
253-5X 230VAC, 3/4W, 2 N.C. Contacts, -51C to +71C
253-6X 230VAC, 3W, 3.0 Sec. TD
254-1X 415VAC, 3W, 290-415-519V
254-2X 220/380VAC, 4W, 2 N.C. Contacts
254-3X 416VAC, 3/4W, 2 N.C. Contacts, -51C to 71C
255-HX 460VAC, 3W, 125VDC 3A Contacts
255-1X 460VAC, 3/4W, Spike Suppression
255-2X 480VAC, 3W, High Shock
255-3X 495VAC, 3W, 3.0 Sec. TD
11–40
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Additional Relays (Continued)
255-4X 460VAC, 3W, 2 N.O. Contacts,
EMD # 9333490
255-5X 460VAC, 3W, Sim. to 255-4X, MIL-R-5757,
10A Relay
255-6X 460VAC, 3W, EMD# 9337151
255-7X 460VAC, 3W, Sim. to 255X, Fast operating,
40mSec.
255-8X 480VAC, 3W, 5.0 Sec. fixed TD, 120VAC
Control
255-9X 480VAC, 3W, Sim. to 255-8X except +/- 10%
Setting
AC, SINGLE PHASE, 50-400HZ
256-1X 600VAC, 3W, 60Hz, 2 N.O. Contacts,
EMD Canada
256-2X 575VAC, 3W, GM# 6964912 Rev. A
DC
250DC-HX 24VDC, 16-24-30V Range, 48VDC 3A Contacts
250DC-1X 28VDC, MIL Shock and Vibration
250DC-2X 26VDC, UV 20-30V, OV 26-36V
250DC-3X 28VDC, 20-28-35V Range, Hi Shock,
-40C to 70C
250DC-4X 14VDC, Commonwealth Edison
250DC-5X 28VDC, Commonwealth Edison
251DC-1X 48VDC, Removable Cover
251DC-2X 35VDC, UV 23-30V, OV 40-52V
251DC-3X 30VDC, UV 21-27V, OV 30-40V
251DC-HX 48VDC, 32-48-60V, 48VDC 3A Contacts
251DC-4X 60VDC, 45-60-75VDC, 2N.O. 120VAC
Contacts
252DCX 120VDC, 85-120-150V Range
252DC-1X 130VDC, 80-130/120-150V Range
252DC-1HX 125VDC, 85-125/125-160V, 48VDC 3A
Contacts
252DC-2X 130VDC, 80-130/120-150V, Removable Cover
253DCX 250VDC, 175-250-315VDC Range
253DC-HX 250VDC, 175-250-315VDC, 48VDC 3A
Contacts
REVERSE POWER RELAYS
AC, SINGLE PHASE
710-HX 120/220/266VAC, 125VDC 3A Control
710-PX 120/220/266VAC, 0.2-1.0A, Spike Suppression
710-1X 120/220/266VAC, 125VDC 1/4A Control
710-3X 120VAC (L-N), 1 Phase, 3-5A
120/220/266VAC. SINGLE PHASE
TIME DELAY
710TD-1X 0.05-0.25A, 0.5-10 Sec. T.D. with Knobs
710TD-5X 2 N.O. Contacts
710TD-7X 60Hz, Reverse Inductive
710TD-7PX Similar to 710TD-7X with Suppression
710TD-8X Similar to 710TDX with -55F to +150F
710TD-9X Similar to 710TDX with Suppression
710TD-12X Similar to 710TDX, 125VDC 2A Contacts
710TD-14X 50Hz, Reverse Inductive
720TD-14X 120 V, L-L, 50Hz, Reverse Inductive
721TD-14X 230 V, L-L, 50Hz, Reverse Inductive
722TD-14X 380 V, L-L, 50Hz, Reverse Inductive
723TD-14X 460 V, L-L, 50Hz, Reverse Inductive
724TD-14X 575 V, L-L, 50Hz, Reverse Inductive
725TD-14X 415 V, L-L, 50Hz, Reverse Inductive
726TD-14X 100 V, L-L, 50Hz, Reverse Inductive
727TD-14X 185 V, L-L, 50Hz, Reverse Inductive
PHASE SEQUENCE RELAYS
AC, THREE PHASE
900-2PX 208-230VAC, Spike Suppression
900-4X 208VAC, 50/60 Hz
900-5X 120VAC, 50/60Hz
900-8X 120VAC, 60 Hz, 125VDC 2A Contacts
900-10X 120VAC, 60 Hz, Spike Suppression
901-1X 440VAC, 60 Hz, 5A Contacts
901-5X 575VAC, Porcelain Term., AZ Relay
901-6X 460VAC, 60 Hz, Spike Suppression
901-SX 440VAC, 55-65HZ, HI-Shock
910-1X 220/440VAC, 60 Hz, N.O. Contacts
910-2X 220/440VAC, 60 Hz, Reversed Contact
Operation
910-3X 220/440VAC, 60 Hz, Porcelain Term.,
Sigma Relay
920X 380VAC, 50 Hz
920-1X 380VAC, 50 Hz, Mounting per 21-037
920-2X 380VAC, 50 Hz, Porcelain Terminals,
Sigma Relay
920-3X 416VAC, 50 Hz, 5A Contacts
920-5X 220/380VAC, 50 Hz
920-6X 440VAC, 50 Hz
930X 208VAC, 400 Hz
930-1X 208VAC, 400Hz, 2A at 28VDC Contacts,
Energized A-B-C, 5A
930-3X 400VAC, 400Hz
930-4X 400VAC, 2 N.C. Contacts, -51C to +71C
931X 120VAC, 400 Hz.
932-5X 115/200VAC, 400Hz, 2A Contact,Hi-Shock
932-7X 230/400VAC, 400Hz
PHASE FAILURE RELAYS
980X 120VAC, 60 Hz, no T.D. on Starting
981X 230VAC, 60 Hz, no T.D. on Starting
982X 460VAC, 60 Hz, no T.D. on Starting
983X 380VAC, 60 Hz, no T.D. on Starting
984X 575VAC, 60 Hz, no T.D. on Starting
985X 525VAC, 60 Hz, no T.D. on Starting
1980X 120VAC, 60 Hz
1981X 230VAC, 60 Hz
1982X 460VAC, 60 Hz
1983X 380VAC, 50 Hz
1984X 575VAC, 60 Hz
1985X 525VAC, 60 Hz
1986X 415VAC, 50 Hz
1987X 380VAC, 60 Hz
SUFFIX: “-S”: Time Delay (0.5 - 30 Sec.)
“-3S”: Factory Set Time Delay (0-60 Sec.)
1981-1SX 230VAC, Similar to 1981X except 50 Hz
1980-2SX 120VAC, Similar to 1980X except N.C.
Contacts
AC, THREE PHASE, VOLTAGE SENSITIVE
1003X-60HZ 380VAC, Similar to 1003X except 60HZ
1009X 415VAC, 50 Hz
1010X 208VAC, 50 Hz.
11–41
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Additional Relays (Continued)
1001X-1010X SUFFIX “-1”: N.C. Contact (example: 1004-1X)
1001X-1010X SUFFIX “-2”: -53C to +70C, 2% Drift below -20C
1001X-1010X SUFFIX “-3”: 400Hz, N.O. Contacts
1001X-1010X SUFFIX “-T’: Spike Suppression
1001X-1010X SUFFIX “-H’: 125VDC 3A Contacts
1001X-1010X SUFFIX “-9” 1 N.O. & 1 N.C. Contacts
1001X-1010X SUFFIX “-12”: Spike Supp., 125VDC 3A Contacts
1001X-1010X SUFFIX “-13”: 1N.O + 1 N.C. 125VDC 3A Contacts
OVERCURRENT RELAYS
1100X 120VAC, 1-5A Range
1100-1X 120VAC, 0.5-5A Range, Remote Adjust
1100-2X 120VAC, 0.5-5A Range
1100-2SX 120VAC, 0.5-5 A Range, Hi-Shock, 2A Contact
1100-9X 120VAC, 1-5A, Fast Operating
1100-11X 120VAC, 1-5A, 3% Diff., Suppression 2.5KV
1100-13X 120VAC, 1-5A, 2 N.C. Contacts
1100-14X 120VAC, 7-30A, 2 N.C. Contacts
1100-15X 120VAC, 2-10A, 2 Sec. T.D.
1100-17X 120VAC, 1-5A, 2 Sec. T.D.
1100-18X 120VAC, 0.05-0.15A, 5A Max, 400 Hz
1100-19X 24VDC, 1-5A Range
1100-20X 120VAC, 1-5A, Suppression (15 times in-rush)
1100-21X 74VDC, 7-30A, 50mS T.D., Shock & Vibration
1100-22X 120VAC, 1-5A Remote Adjust
1100-23X 125VDC, 0.25-1.8A, 1 N.O.
125VDC 2A Contact
1100-24X 32VDC, 1-5AAC Range
1100-25X 120VAC, 0.25-1.25A
1100-26X 120VAC, 0.3-1.5A, Withstand 5A
1100-27X 220VAC, 1-5A Range, 220VAC Contacts
1100-32X 120VAC, Undercurrent 1-10A Adj,
0.2-5 Sec. T.D.
1100-35X 120VAC, 0.1-0.4A Range
1100-36X 74VDC, 4-20A, 50mS T.D., Shock & Vibration
1100-37X 24VDC, 0.1-0.3A Range
1100-38X 74VDC, Similar to WC1-74DC-5
AC, SINGLE PHASE, ADJ. DIFFERENTIAL
D1100X 120VAC, 1-5A Range
D1100-2X 220VAC, 1-5A Range
D1100-3X 120VAC, 4-12A Range
D1100-4X 230VAC, 4-12A Range
D1100-5X 460VAC, 4-12A Range
D1100-6X 120VAC, 1-5A Range, 1-2 Sec. T.D.
D1100-7X 120VAC, 0.7-5A Range,
125VDC 0.5A Contacts
D1100-8X 120VAC, 5-15A Range
AC, SINGLE PHASE, TIME DELAY
1100TDX 120VAC, 1-5A Range, 0.5-30 Sec. T.D.
1100TD-HX 120VAC, 1-5A, 0.5-30 Sec. T.D.,
125VDC 3A Cont.
1100TD-SX 120VAC, 1-5A Range, 0.5-20 Sec. T.D.,
Hi-Shock
1100TD-1X 240VAC, 1-5A Range, 0.5-30 Sec. T.D.
1100TD-2X 24VDC, 1-5AAC Range, 0.5-30 Sec. T.D.
1100TD-3X 120VAC, 0.5-5A Range, 0.5-30 Sec. T.D.
1100TD-5X 120VAC, 0.5-2.5A Range, 0.5-30 Sec. T.D.
1100TD-6X 120VAC, 1-5A , 0.2-20 Sec. T.D.,
Manual Reset
1100TD-8X 220VAC, 2-10A Range, 220VAC 5A Contacts
1100TD-9X 24VDC, 0.5-5AAC Range, 0.5-20 Sec. T.D.
1100TD-10X 120VAC, Sim. to WCT1-120AC-5 w/
removable cover
1100TD-11X 120VAC, Sim. to WCT1-120AC-5, 1-5 Min. T.D.
1100TD-12X 120VAC, Sim. to WCT1-120AC-5,
0.5-5 Sec. T.D.
OPTION 1: 0.2A to 1.0A Range
2.5: 0.5A to 2.5A Range
5: 1.0A to 5.0A Range
10: 2.0A to 10.0A Range
AC, THREE PHASE, TIME DELAY
1130TDX 120VAC, 1-5A, 0.5-20 Sec. T.D.
1130TD-1X 24VDC, 1-5A, 0.5-20 Sec. T.D.
1130TD-2X 120VAC, 1-5A, 0.5-20 Sec. T.D., Suppression
1130TD-3X 120VAC, 1-5A, 0.5-60 Sec. T.D.,
2 N.C. Contacts
1150X 120VAC, 4.35A, 0.5-5 Sec. T.D.
1150-1X 120VAC, 4.26A, 0.5-5 Sec. T.D.
1150-2X 120VAC, 3.72A, 0.5-5 Sec. T.D.
1150-4X 120VAC, 1-5A, (P.G.E.)
1150-6X 120VAC, 1-5A, 2-3 Sec. T.D. on D.O.
1150-8X 120VAC,Same as 1150-2X with
2 N.O. Contacts
1150-10X 120VAC, 1-5A, 2 Sec. T.D.
1150-10SX 120VAC, 1-5A, 2 Sec. T.D., Hi-Shock
1150-11X 120VAC, 2.5-5A, 400Hz, Special T.D. Curve
1150-12X 120VAC, 2.5-5A, 60Hz, Special T.D. Curve
1150-14X 120VAC, 2.5-5A, 400Hz, T.D. Curve, Aux. N.O.
1150-15X 24VDC, 1.2-2.2A, 60Hz, T.D. Curve, (Solar)
1150-16X 24VDC, 2.5-4.3A, 60Hz, T.D. Curve, (Solar)
VOLTAGE RESTRAINT
1200X 120VAC, 1-5A, 24VDC Control
1200-1X 120VAC, 1-5A, 12VDC Control
1200-4X 120/208VAC, 1-5A, 3 Phase, 24VDC Control
1200-5X 120VAC, 1-5A, 3 Phase, 24VDC Control
1200-6X 120VAC, 1-5A, 3 Phase, 24VDC Control,
Suppression
1200-7X 120VAC, 1-5A, 1 Phase, 120VAC Control
1200-8HX 120VAC, 1-5A, 3 Phase, 125VDC Control
DC
1100DCX 120VAC, 10-50mV ext. Shunt, 5A Contacts
1100DC-1X 230VAC, 0-10VDC ext. Shunt, 5A Contacts
1100DC-2X 120VAC, 10-50mV ext. Shunt,
Transistor Output
1100DC-3X 120VAC, 0.2-0.6ADC with 0.125 ohm Shunt
1100DC-4X 28VDC, 10-50mV, Inverter, ext. Shunt,
2 Sec. T.D.
1100DC-6X 125VDC, 10-50mV, Inverter,
125VDC 3A Contacts
1100DC-7X 120VAC, 10-50mV, Inverter,
125VDC 3A Contacts
1100DC-8X 120VAC, isolated outputs
1100DC-9X 250VDC, 150mV Shunt, Hi-Shock,
+/- 20% Adj.
1100DC-10X 120VAC, 50-150mV
1100DC-11X 220VDC, 5-25mV, 1-25 Sec. T.D.,
Inverse Current
1100DC-13X 120VAC, 20-35mV, Hi-Shock
1100DC-15X 12VDC, 10-50mV, Inverter
1100DC-17X 74VDC, 10-50mV, Inverter
1100DC-20X 120VAC, Similar to 1100DCX except 4-25mV
11–42
Protective Relays
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Additional Relays (Continued)
UNDERCURRENT RELAYS
21-693-1 Self Contained CT, 120VAC Control
21-693-2 Self Contained CT, 230VAC Control
CURRENT DIFFERENTIAL
1350X 24VDC, 0.1-0.5A Range
1350PX 24VDC, 0.1-0.5A Range, Suppression,
1 N.O. Contact
1350SX 24VDC, 0.1-0.5A Range, High Shock
1350-1X 24VDC, 0.1-0.5A Range, 1 N.C. Contact
1350-3X 48VDC, 0.1-0.5A Range
1351X 120VAC, 0.1-0.5A Range
1351PX 120VAC, 0.1-0.5A Range, Suppression
1351SX 120VAC, 0.1-0.5A Range, High Shock
1351-1X 120VAC, 0.1-0.5A Range, 1 N.C. Contact
1351-2X 120VAC, 2 Sec. T.D. on application of voltage
1351-4X 120VAC, 0.1-0.5A Range, Fast,
125VDC Contacts
PARALLELING (SYNCHRO-CHECK) RELAYS
1880X 200VAC, 1 N.O. & 1 N.C. Contact
1890X 90VAC, 1 N.O. & N.C. Contact
SUFFIX “-A”: Two Normally Open Contacts
“-B”: Two Normally Closed Contacts
“-P”: Spike Suppression
“-7”: 0.025 Second Time Delay
“-9”: 125VDC 2A Contacts
“-13”: 0.250 Second Time Delay
DEAD BUS TYPE
1880DBX 200VAC, 1 N.O. & 1 N.C. Contact
1890DBX 90VAC, 1 N.O. & 1 N.C. Contact
SUFFIX “-A”: 2 Normally Open Contacts
“-B”: 2 Normally Closed Contacts
“-S”: High Shock
“-2”: 2 N.O. Contacts, Cond. 5 same as 3
“-3”: Condition 1 reversed
“-5”: 12 deg. to 36 deg. adjustment
“-8” 3 Phase, Phase Sequence
“-9”: 125VDC 2A Contacts
“-12”: 25 Hz, 125VDC 3A Contacts
DOUBLE DEAD BUS (EITHER BUS DEAD)
1880DDBX 200VAC, 1 N.O. & 1 N.C. Contact
1890DDBX 90VAC, 1 N.O. & 1 N.C. Contact
SUFFIX “-A”: 2 Normally Open Contacts
“-B”: 2 Normally Closed Contacts
“-9”: 125VDC Contacts; 2A res. , 1A ind.
DOUBLE DEAD BUS, UNDERVOLTAGE
2800-120 120VAC, Ph. Ang. 5-25 deg.,
UV: 70% D.O. 80% P.U.
2800-208 208VAC, Ph. Ang. 5-25 deg.,
UV: 70% D.O. 80% P.U.
2800-240 240VAC, Ph. Ang. 5-25 deg.,
UV: 70% D.O. 80% P.U.
2800-380 380VAC, Ph. Ang. 5-25 deg.,
UV: 70% D.O. 80% P.U.
2800-416 416VAC, Ph. Ang. 5-25 deg.,
UV: 70% D.O. 80% P.U.
2800-440 440VAC, Ph. Ang. 5-25 deg.,
UV: 70% D.O. 80% P.U.
2800-480 480VAC, Ph. Ang. 5-25 deg.,
UV: 70% D.O. 80% P.U.
2800-600 600VAC, Ph. Ang. 5-25 deg.,
UV: 70% D.O. 80% P.U.
PHASE BAND MONITOR
2850X 208/230/460 V, 5-60 deg. Range, 60 Hz
2850-1X 208/240/380/480 V, 5-45 deg. Range, 50/60 Hz
OVERFREQUENCY RELAYS
WOF-12-100110 120VAC, 100-110 Hz. Range
SUFFIX “-1”: 0.2% Max. Differential
“-T”: 0.5-20 Sec. Time Delay
“-2T”: 60 Second Time Delay
“-S”: High Shock
23-050X 120VAC, 50-60 Hz
23-060X 120VAC, 60-70 Hz
23-400X 120VAC, 400-450 Hz
UNDERFREQUENCY RELAYS
22-050X 120VAC, 50-60 Hz
22-060X 120VAC, 60-70 Hz
22-400X 120VAC, 400-450 Hz
FREQUENCY RELAYS (Over or Under)
25-050HX 120VAC, 40-50-60 Hz, 125VDC 3A Contacts
25-050SX 120VAC, 40-50-60 Hz, High Shock
25-050-1X 120VAC, 40-50-60 Hz, 2 N.C. Contacts
25-050-2X 120VAC, 40-50-60 Hz, 1.2 Sec. Time Delay
25-060HX 120VAC, 50-60-70 Hz, 125VDC 3A Contacts
25-060SX 120VAC, 50-60-70 Hz, High Shock
25-060-1X 120VAC, 50/60 Hz +/-10% on each Frequency
25-060-2X 120VAC, 50-60-70 Hz, 0.4 Hz Differential
25-060-3X 120VAC, 50-60-70 Hz, 2 N.C. Contacts
25-060-4X 120VAC, 50-60-70 Hz, 2 N.O. Contacts
25-060-5X 120VAC, 50-60-70 Hz, 2 N.O, 10A MIL-R-5757
25-060-7X 120VAC, EMD #9337150, Set 57.4 &
62.6 +/-0.6 Hz
25-060-8X 120VAC, 50-60-70 Hz, 1 Sec. T.D.
25-060-10X 120VAC, Spike Suppression
25-060-12X 104VAC, 50-60-70 Hz
25-060-14X 240VAC, 50-60-70 Hz
25-060-18X 120VAC, 50-60-70 Hz, 1 Sec. T.D.,
Suppression
25-060-19X 120VAC, 50-60-70 Hz, 0.5-10Sec. T.D.,
12VDC Ctrl.
25-060-20X 120VAC, 50-60-70 Hz, 0.5-10Sec. T.D.,
24VDC Ctrl.
25-100X 120VAC, 90-100-110 Hz
25-400X 120VAC, 350-400-450 Hz
25-400-2X 120VAC, 350-400-450 Hz,
220VAC 5A Contacts
25-400-5X 120VAC, 350-400-450 Hz, Suppression
25-025T-1HX 480VAC, 20-25-30 Hz, 0.5-20Sec T.D.,
125VDC 3A Contacts
25-025T-2HX 120VAC, 20-25-30 Hz, 0.5-20Sec. T.D.,
125VDC 3A Contacts
25-100T-1HX 480VAC, 90-100-110 Hz, 0.5-20Sec. T.D.,
125VDC 3A Contacts
20-040-1X 100VAC, 40-50 Hz
20-040-2X 120VAC, 40-50 Hz, 1.5-2.0 Sec. T.D.
11–43
Protective Relays
Protective Relays
11
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
Additional Relays (Continued)
20-040-3X 120VAC, 40-50 Hz, 2 N.C. Contacts
20-040-4X 220VAC, 40-50 Hz.
20-050-HX 120VAC, 50-60 Hz, 125VDC 3A Contacts
20-050SX 120VAC, 50-60 Hz, High Shock, MIL-S-901C
20-050-1X 120VAC, 50-60 Hz, 0.2 Sec. T.D.
20-050-2X 120VAC, 45-66 Hz, U.L.
20-050-3X 120VAC, 50-60 Hz, 2000V PIV Diode
20-050-4X 120VAC, 50-60 Hz, 1 Sec. T.D., 0.5% Drift
20-050-8X 120VAC, 57-60 Hz, 0.2 Hz Diff.,
240V Contacts, FAA
20-050-8PX 120VAC, Similar to 20-050-8X w/
Spike Suppression
20-050-9X 120VAC, 45-55 Hz
20-050-10X 120VAC, 50-60 Hz, Suppression
20-050-12X 120VAC, 50-60 Hz, 125VDC Contacts
20-050-13X 120VAC, 50-60 Hz, 2 Sec. T.D.
20-050-16X 150VAC, Similar to 20-050-10X except Voltage
20-050-19X 120VAC, Volt./Freq., 45-60 Hz, 85-120V
20-050-19PX 120VAC, Similar to 20-050-19X w/
Suppression
20-050-20X 120VAC, 50-60 Hz, 2 N.C. Contacts
20-050-21X 220VAC, 50-60 Hz
20-050-22X 120VAC, 50-60 Hz, 125VDC Contacts,
Seismic
20-050-23X 240VAC, Similar to 20-050-19X except Voltage
20-050-23PX 240VAC, Similar to 20-050-23X w/Suppression
20-050-25X 104VAC, 50-60 Hz
20-050-26X 120VAC, 57-60 Hz, Supp., 0.2 Sec. T.D. on
D.O.
20-050-27X 120VAC, Sim. to 20-050-26X, Operation
Reversed
20-050-28X 120VAC, Sim. to 20-050-2X with Suppression
20-050-29X 120VAC, Sim. to 20-050-19X w/125VDC 2A
Contacts
20-050-30X 120VAC, Sim. to 20-050-1X w/125VDC 2A
Contacts
20-050-31X 200-480VAC, 50-60 Hz Range, 26VDC
Control
20-050-32X 120VAC, Sim. to WUF-12-5060T,
Operation Rev.
20-060-1X 120VAC, 60-70 Hz, 2000V Diode
20-060-2X 120VAC, 60-63 Hz, 0.2 Hz Diff., 240VAC
Contacts
20-060-2PX 120VAC, Sim. to 20-060-2X w/Suppression
20-060-4X 120VAC, 65-77 Hz
20-060-5X 120VAC, Jumper, Set at 60 Hz +3% or
50 Hz +3%
20-060-6X 120VAC, 103-156V Range, 60-70 Hz,
Set at 70 Hz
20-060-7X 120VAC, 60-63Hz, 0.2 Sec T.D. on P.U.,
Suppression
20-060-8X 120VAC, 60-70 Hz, Spike Suppression
20-060-9X 120VAC, 60-70 Hz, 0.25 Sec. Inverse T.D.
on P.U.
20-350X 120VAC, 350-500Hz
20-350SX 120VAC, 350-400Hz, 2 N.C. 2A Contacts,
Hi-Shock
20-350-2SX 115VAC, 350-400Hz, Hi-Shock
20-350-4X 120VAC, 300-400 Hz
20-400X 120VAC, 400-450 Hz
20-400SX 120VAC, 400-450 Hz, High Shock
20-400-2SX 115VAC, Hi-Shock
20-400-3X 120VAC, 400-450 Hz, 2 N.C. Contacts
20-400-4X 120VAC, 400-500 Hz
ADJUSTABLE DIFFERENTIAL
D20-040X 120VAC, 40-50 Hz
D20-050X 120VAC, 50-60 Hz
D20-050-2X 120VAC, P.U. 50-60 Hz, D.O. 40-50 Hz
D20-060X 120VAC, 60-70 Hz
VOLTAGE UNBALANCE RELAYS
1500X 120VAC, 3 Phase, 15% - 25% Adjustment
1510X 230VAC, 3 Phase, 15% - 25% Adjustment
1520X 380VAC, 3 Phase, 15% - 25% Adjustment
1530X 460VAC, 3 Phase, 15% - 25% Adjustment
1540X 575VAC, 3 Phase, 15% - 25% Adjustment
1550X 208VAC, 3 Phase, 15% - 25% Adjustment
SUFFIX “-2”: N.C. Contacts (Example: 1500-2X)
“-3”: 10% - 20% Adjustment
“-4”: Transient Suppression
“-H”: 125VDC 3A Contacts