SUHNER FIBEROPTIC
OPTOCLIP II
BARE FIBRE ADAPTER
Starting from the ferruleless and easy-to-
assemble standard connector OPTOCLIP II of
HUBER+SUHNER, new applications have been
developed. The new OPTOCLIP II REPEAT
connector (as suggested by its name) can be
assembled more than just once. A threaded
clamping device locks the fibre in place inside
the connector. If required, it can be opened
again, allowing the connector to be reassemb-
led. Apart from crimping, the assembly pro-
cedure is identical to the one applied for the
standard OCTOCLIP II, which allows the same
time-saving tool to be used. The OPTOCLIP II
REPEAT may be applied, for example, during
fibre adjustments in laser manufacturing or in
laboratory setups, that is, wherever an optical
connection is established briefly and only once
for checking purposes. Thus, the OPTOCLIP II
REPEAT can be reused over and over again.
In case of repeated matings – such as are com-
mon also in measurement applications – the
fibre end faces are subjected to heavy wear.
Instead of using a new connector, the OPTO-
CLIP II REPEAT can simply be reassembled.
Waiver
While the information contained has been carefully compiled to the best of our present knowledge, it is not
intended as representation or warranty of any kind on our part regarding the fitness of the products concerned
for any particular use or purpose and neither shall any statement contained herein be construed as a
recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of
each product for any particular purpose must be checked beforehand with our specialists.
HUBER+SUHNER AG
Fiberoptic Division
9100 Herisau, Switzerland
Phone +41 (0)71 353 41 11
Fax +41 (0)71 353 46 47
www.hubersuhner.com
01.05.0141e/02.98/2000
Applications: Features:
Original Equipment Manufacturer (OEM) Integrated alignment element
Test and Measurement Assembly in less than 3 minutes,
Laboratory through Crimp and Cleave procedure
Line check Fibre locking via threaded clamping device
Temporary connection Repeated assembly possible
Specifications
Insertion loss 50% < 0.1 dB; 98% < 0.25 dB
Operating temperature 20° to +80°C
Number of terminations 200 times
Ordering information
Denomination Order number
Singlemode; 250µm fiber/900µm semi tight tube FOC-REP-A600
Multimode; 250µm fiber/900µm semi tight tube FOC-REP-B600
Singlemode; 900µm tight tube FOC-REP-A601
Multimode; 900µm tight tube FOC-REP-B601
Types printed extra bold are stock items.