NEMIC-LAMBDA JWS 240P SPECIFICATIONS A182-01-01 MODEL ITEMS Nominal Output Voltage Average Output Current Peak Output Current (*1) Average Output Power Peak Output Power (*1) Efficiency (Typ) (*2) Input Voltage Range (*3) Input Current (100/200VAC)(Typ) (*2) Inrush Current(Typ) (*4) PFHC Power Factor (100/200VAC)(Typ) (*2) Output Voltage Range Maximum Ripple & Noise 0 ~ +65C (*5) -10 ~ 0C Maximum Line Regulation (*6) Maximum Load Regulation (*7) Temperature Coefficient Over Current Protection (*8) Over Voltage Protection (*9) Hold-up Time (Typ) (*10) Leakage Current (*11) Remote Sensing Remote ON/OFF control Monitoring Signal Parallel Operation Series Operation Operating Temperature (*12) Operating Humidity Storage Temperature Storage Humidity Cooling Withstand Voltage JWS240P-24 JWS240P-48 24 48 10 5 20 10 240 240 480 480 80 80 85 ~ 265VAC (47 ~ 63Hz) 3.2/1.6 20A at 100VAC, 40A at 200VAC Built to meet EN61000-3-2 0.99/0.95 21.6 ~ 28.8 43.2 ~ 52.8 240 480 360 720 14 96 192 15 192 384 16 Less than 0.02%/C 17 A 20.4 ~ 10.2 ~ 18 V 30.0 ~ 34.8 55.2 ~ 64.8 19 20ms 20 0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC 21 Possible 22 Possible 23 PF (Open Collector Output) 24 --25 Possible 26 -10 ~ +65C ( -10 ~ +50C:100%, +60C:70%,+65C:55% ) 27 30 ~ 90%RH (No dewdrop) 28 -30 ~ +85C 29 10 ~ 95%RH (No dewdrop) 30 Forced Air By Blower Fan 31 Input - FG:2kVAC(20mA), Input - Output:3kVAC (20mA) Output - FG:500VAC(100mA), Output-CNT:100VAC(100mA) for 1min. 32 Isolation Resistance More than 100Mohm Output - FG... 500VDC More than 10Mohm Output - CNT... 100VDC at 25C and 70%Rh 33 Vibration At no operating, 10-55Hz (Sweep for 1min) 2G Constant, X, Y, Z 1hour each. 34 Shock (In package) Less than 20G 35 Safety (*13) Built to meet UL1950, CSA950, EN60950,VDE0160. Built to meet DENTORI. 36 Conducted Emission Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A. 37 Radiated Emission Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A. 38 Weight (Typ.) g 1900 39 Size (WxHxD) mm 120 x 92 x 190 ( Refer to Outline Drawing ) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. Operating time at peak output is less than 10sec.(Duty<=0.5) *2. At 100/200VAC, Ta=25C and average output power. *3. For cases where conformance to various safety specifications (UL, CSA, EN) are required, input voltage range will be 100-240VAC(50/60Hz). *4. First in-rush current. Not applicable for the in-rush current to Noise Filter less than 0.2ms. *5. Measure with EIAJ RC-9131A probe, Bandwidth of scope :100MHz. *6. 85 - 265VAC , constant load. *7. No load - Average load, constant input voltage. *8. Constant current limit with automatic recovery. Peak current and shorted conditions more than 10 seconds, which could be result of shut down the output voltage. *9. OVP circuit will shut down output, manual reset (Line recycle). *10. At 100/200VAC nominal output voltage and average output current. *11. Measured by the each measuring method of UL, CSA, EN and DENTORI(at 60Hz). *12. Ratings - Derating at standard mounting. - Load (%) is percent of average output power or averge output current, whichever is greater. - As for other mountings, refer to derating curve (A182-01-02_). *13. As for DENTORI, built to meet at 100VAC. 1 2 3 4 5 6 7 8 9 10 11 12 13 A1820101_Pdf.xls V A A W W % A V mV mV mV mV NEMIC-LAMBDA JWS 240P OUTPUT DERATING A182-01-02 Ta(C) -10 ~+35 45 50 60 65 MOUNTING A 100 100 100 70 55 AVERAGE LOAD(%) MOUNTING B MOUNTING C 100 100 100 100 100 100 70 70 55 55 MOUNTING D 100 70 55 - AVERAGE LOAD(%) OUTPUT DERATING CURVE 100 80 MOUNTING A,B,C MOUNTING D 60 40 20 0 -10 0 10 20 30 40 50 60 70 Ta(C) MOUNTING A (STANDARD MOUNTING) A1820102.xls MOUNTING B MOUNTING C MOUNTING D