1power.pulseelectronics.com P708. L (01/19) http://www.power.pulseelectronics.com/contact
High Isolation Power Transformers
EP7 Platform SMD - PH9185.XXXNL and PM2190.XXXNL
Push Pull Transformer
Reinforced insulation for isolated power supply
driver
8mm creepage
5KVrms isolation (1000Vrms continuous)
UL and TUV certied
Electrical Specifications @ 25°C - Operating Temperature -40°C to +125°C
Part Number Inductance (1-3)
(µH ±45%)
Leakage Inductance
(µH MAX)
DCR (1-3)
(Ω MAX)
DCR (4-6)
(Ω MAX)
ET MAX (1-3)1
(V-µsec MAX)
CAP
(pF MAX)
Turns Ratio
(1:3) (6:4)
Isolated Voltage2
(Vrms)Commerical Automotive8
PH9185.011NL PM2190.011NL 750 1.2 0.50 0.55 66 10.0 1CT : 1CT
5000
PH9185.012NL PM2190.012NL 450 0.9 0.40 0.80 52 10.0 1CT : 2CT
PH9185.013NL PM2190.013NL 200 0.6 0.35 0.95 36 8.0 1CT : 3CT
PH9185.021NL PM2190.021NL 1800 3.0 0.75 0.45 100 10.0 2CT : 1CT
PH9185.034NL PM2190.034NL 750 1.2 0.50 0.75 66 10.0 3CT : 4CT
PH9185.038NL PM2190.038NL 310 0.9 0.44 1.00 44 8.0 3CT : 8CT
PH9185.043NL PM2190.043NL 1260 1.5 0.70 0.56 89 12.0 4CT : 3CT
PH9185.083NL PM2190.083NL 2350 6.0 0.90 0.40 110 8.0 8CT : 3CT
PH9185.XXXNL/PM2190.XXXNL
Mechanical Schematic
Weight ...................2.6grams
Tape & Reel ...............150/reel
Tray .............................80/tray
Notes:
1. The ET Max is calculated to limit the core loss and temperature rise at 100KHz based on a
bipolar flux swing of 180mT Peak.
2. For Push-Pull topology, where the voltage is applied across half the primary winding
turns, the ET needs to be derated by 50% for the same flux swing.
3. The applied ET may need to be further derated for higher frequencies based on the
temperature rise which results from the core and copper losses
A. To calculate total copper loss (W), use the following formula:
Copper Loss (W) = Irms_Primary2 * DCR_Primary + Irms_Secondary2*DCR_Secondary
B. To calculate total core loss (W), use the following formula:
Core Loss (W) = 4.40E-10 * (Frequency in kHz)1.67 * (180 * [ET/ET Max])2.53
Where ET is the applied Volt Second, ET Max is the rated Volt Second for 180mT flux
swing
C. To calculate temperature rise, use the following formula: Temperature Rise (°C) =
90 * (Core Loss(W) + Copper Loss (W))
4. The AEC-Q200 temperature and humidity operational life testing was completed using a
dielectric strength test of 5000Vdc.
5. Optional Tape & Reel packing can be ordered by adding a “T” sux to the part number
(i.e. PH9185.012NL becomes PH9185.012NLT). Pulse complies to industry standard tape and
reel specification EIA481.
6. The “NL” sux indicates an RoHS-compliant part number.
7. Continuous isolation voltage confirmed by 125°C/1000hrs accelerated aging with the bias
voltage applied between primary and secondary windings.
8. The PM2190.XXXNL part numbers are AEC-Q200 and IATF16949 certified. The mechanical
dimensions are 100% tested in production but do not necessarily meet aproduct capability
index (Cpk) >1.33 and therefore may not strictly conform to PPAP.
Dimensions:
Unless otherwise specified,
all tolerances are ±
Inches
mm
.010
0,25