Hobbs Hour Meters and Pressure Switches Hobbs 85000 Series Quartz Plus Hour Meters c Custom CMOS Integrated Circuit c Totally Sealed Case c Temperature Range: 40F to +185F (40C to +85C) c Shock and Vibration Resistant c UL Recognized and CSA Certified Hobbs 20000 Series AC Hour Meters c Running Indicator c 3 mm (0.12") Numeral Height c Transient Voltage and Reverse Polarity Protected c Standard Terminals: 1/4" Male Blade The 85000 Series Quartz Plus provides legendary Hobbs performance and reliability in a technically advanced quartz package. The Quartz Plus features a rugged drive mechanism inside a shock-proof, tamper-proof, totally sealed case. Direct Current Hour Meters Stock No. Mfr.Os Type Fig. Description Voltage Range 611-3000 611-3001 611-3002 611-3003 611-3004 85094-12 85331-12 85097-02 85093-03 85342-03 A A B C C 2-Screw Mount 2-Screw Mount 3-Screw Mount Round (2.27" Black Bezel) Round (2.27" Chrome Bezel) 10-80 VDC 5-16 VDC 10-80 VDC 10-80 VDC 10-80 VDC Electrical Termination 1/4" 1/4" Blade Blade 1/4" Blade 1/4" Blade 1/4" Blade EACH 32.83 32.83 35.90 36.19 36.92 c Single Phase Synchronous, PermanentlyLubricated Motor c Temperature Range: 65F to +154F (54C to +68C) c c c c 4 Shock and Vibration Resistant UL Recognized, CSA Certified 3.0 Watts Power Rating 3 mm (0.12") Numeral Height Hobbs 20000 Series AC hour meters provide an accurate means of tracking run time on all types of equipment, whether for testing purposes, leasing applications, maintenance records, or warranty programs. The synchronous motor is integrated into the chassis as one substructure for maximum reliability, and the complete unit is installed in a totally sealed case. Alternating Current Hour Meters Stock No. Mfr.Os Type Fig. Description Voltage Range Freq. (Hz) Electrical Termination EACH 611-9998 611-3006 611-2017 611-2019 611-3009 611-3010 611-3011 20001-17 20007-17 20017-14 20019-14 20116-23 20177-23 20182-23 A A B B C C C 2-Screw Mount 2-Screw Mount 3-Screw Mount 3-Screw Mount Retainer Mount Retainer Mount Retainer Mount 108-132 VAC 216-264 VAC 108-132 VAC 216-264 VAC 108-132 VAC 216-264 VAC 108-132 VAC 60 60 60 60 60 60 60 8-32 8-32 8-32 8-32 8-32 8-32 1/4" Blade 33.63 35.82 36.77 38.76 33.63 36.98 33.63 Hobbs 98000 Series LCD Hour Meters c Operating Temperature Range: 40F to +185F (40C to +85C) c Storage Temperature Range: 60F to +200F (50C to +95C) c Power Consumption: <1 mA @ Rated Voltage c Transient Voltage and Reverse Polarity Protected c c c c c Shock and Vibration Resistant Standard Terminals: 1/4" Male Blade UL and CSA Certification Pending Running Indicator 6 mm (0.25") Numeral Height Hobbs has merged digital technology and rugged design into a state-of-the-art hour meter! These LCD hour meters feature a solid-stated electronic quartz movement, totally sealed case, and very low power consumption. LCD Hour Meters Stock No. Mfr.Os Type Fig. Description Voltage Range 611-3012 611-3013 611-3014 98313 98311 98312 A B C 2-Screw Mount Retainer Mount Round (2.27" Black Bezel) 9-64 VDC 9-64 VDC 9-64 VDC Electrical Termination 1/4" 1/4" 1/4" Blade Blade Blade EACH 39.27 40.07 45.95 Hobbs 5000 Series Pressure Switches c c c c c c Contacts: Silver Alloy, Gold Plated Temperature Range: 40F to +250F (40C to +120C) Operating Pressure: 150 psi for 4, 10, and 15 psi Set Points (250 psi for 60 psi Set Points) Burst Pressure: 750 psi for 4, 10, and 15 psi Set Points (1000 psi for 60 psi Set Points) Proof Pressure: 500 psi Electrical Ratings: Resistive N 15 A @ 6 VDC, 8 A @ 12 VDC, 4 A @ 24 VDC; Inductive N 1 A @ 120 VAC, 0.5 A @ 240 VAC The perfect choice for those demanding pressure switch applications. Hobbs 5000 Series pressure switches incorporate direct-action blade contacts for reliable, consistent switching. The polyimide film diaphragm is compatible with a wide variety of fluids. Ideal for oil and air pressure applications where automotive-style switches wonOt hold up. Available in normally-open (N.O.), normally-closed (N.C.), and dualcircuit (D.C.) electrical contact settings. Note: Dual circuit switches contain one set of normally-open and one set of normally-closed contacts. The set point is determined by the N.C. circuit. The deadband between the two sets of contacts can range from 2.5 psi for 4 psi set point switches, to 23 psi for 60 psi set point switches. Switches are designed for use with motor oils, hydraulic and transmission oils, jet fuels and other similar hydrocarbon media. They are not recommended for use with hot water, strong acids, or high pH fluids. Suitability of application is the responsibility of the user. Do not install in areas of extreme heat or vibration. Avoid installing near exhaust manifolds, mufflers, open flames, or other potential sources of media ignition. Always install by using wrench or hex base. Stock No. Mfr.Os Type Description* Set Point EACH 611-3015 611-3016 611-3017 611-3018 611-3019 611-3020 611-3021 611-3022 611-3023 611-3024 611-3025 611-3026 76575-04-01 76577-04-01 76579-04-01 76576-10-01 76578-10-01 76580-10-01 76052-15-01 76062-15-01 76072-15-01 76054-60-01 76064-60-01 76074-60-01 N.O.-2T N.C.-2T D.C.-3T N.O.-2T N.C.-2T D.C.-3T N.O.-2T N.C.-2T D.C.-3T N.O.-2T N.C.-2T D.C.-3T 4 psi 4 psi 4 psi 10 psi 10 psi 10 psi 15 psi 15 psi 15 psi 60 psi 60 psi 60 psi 14.99 24.23 30.45 16.07 23.60 30.45 16.07 22.75 30.45 16.31 23.73 30.45 *N.O.-2T = Normally open, 2 terminal; N.C.-2T = Normally closed, 2 terminal; D.C.-3T = Dual circuit, 3 terminal. For Fast, Dependable Service, Make Just One Call N 1-800-433-5700 ALLIED c 175