Active PFC - Meets EN61000-3-2, -3
•
Single & Dual Outputs
•
Overvoltage & Overcurrent Protection
•
75ms Hold Up Time
•
Wide Input Voltage 90-264 VAC
•
International Safety Approvals
Input
Input Voltage • 90-264 VAC
Input Frequency • 47-63 Hz
Power Factor • 0.96 at 230 VAC, 0.99 at 110 VAC
Inrush Current • 30 A max at 115 VAC, 60 A max
at 230 VAC
Input Current • 3.2 A max at 115 VAC, 1.7 A max
at 230 VAC
Output
Output Voltage • See Tables
Output Power • 130 Watts
Minimum Load • 0 minimum for single output models
See table for multiple output models
Line Regulation • ±1% maximum
Load Regulation • See Table
Ripple & Noise • 2% pk-pk maximum
Transient Response • 4% max deviation, 500 us recovery
time for a 25% load change
Temperature • ±0.04%/°C
Coefficient
Hold up Time • >75ms min at full load, 100 VAC
Overvoltage • On output #1 only
Protection 112% to 132% of nominal,
recycle input to reset
Overcurrent • On all outputs 110% to 150%
Protection with auto recovery
General
Efficiency • 80% typical
MTBF • 100,00 hours minimum at full load
at 25°C ambient
Isolation Voltage • 3000 VAC input to output
1500 VAC input to ground
500 VAC output to ground
Size • 7.71” x 3.46” x 1.99”
Weight • 860 grams approx.
Environmental
Operating • 0°C to 70°C
Temperature Derate linearly from 100% load at
40°C to 50% load at 70°C
Cooling • Thermostat controlled internal fan
Humidity • 5 to 95% RH, non-condensing
Storage • -40°C to +85°C
Temperature
EMC and Safety
EMC • Meets EN61000-3-2, -3
EN55022/CISPR22 Class B and FCC
Part 15 Level B conducted & radiated
Safety • UL 1950, CSA C22.2 No. 234 per cUL,
EN60950, CE Mark
Immunity & Surge • Meets EN61000-4-2, -3, -4, -5, -6,
-8, & 11
Warranty • 1 Year
130 Watts
AEH130 Series
AC/DC External Desktop
Specification
•
Intelligent Design Quality Product
XPiQ inc.
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com