HPH Series www.murata-ps.com Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters Murata Power Solutions' fully isolated HPH series of DC/DC converters affords users a practical solution for their low-voltage/high-current applications. With an input voltage range of 36 to 75 Volts, the HPH Series delivers up to 70 Amps of output current from a fully regulated 3.3V output. PRODUCT OVERVIEW Using both surface-mount technology and planar magnetics, these converters are manufactured on a 2.3" x 2.4", lead-free, open-frame package with an industry-standard pinout. HPH converters utilize a full-bridge, fixedfrequency topology along with synchronous output rectification to achieve a high efficiency. This efficiency, coupled with the open-frame package that allows unrestricted air flow, reduces internal component temperatures thereby allowing operation Typical unit FEATURES RoHS Compliant 3.3V to 12V outputs @ up to 70 Amps Input range: 36V-75V Open Frame: 2.3" x 2.4" x 0.40" Industry-standard package/pinout at elevated ambient temperatures. These DC/DC's provide output trim, sense pins and primary side on/off control (available with positive or negative logic). Standard features also include input undervoltage shutdown circuitry, output overvoltage protection, output short-circuit and current limiting protection and thermal shutdown. All devices are certified to IEC/UL/EN60950-1, 2nd Edition safety standards and carry the CE mark (meet LVD requirements). Remote sense, Trim, On/Off control High efficiency: up to 91% Fully isolated, 2250Vdc (BASIC) Input undervoltage shutdown Output overvoltage protection Short circuit protection, thermal shutdown Certified to UL/EN/IEC 60950-1, 2nd Edition, CAN/CSA-C22.2 No. 60950-1 safety approvals Contents Description, Photograph, Connection Diagram Ordering Guide, Model Numbering Mechanical Specs, Input/Output Pinout Detailed Electrical Specifications, Soldering Guidelines Application Notes Performance Data Page 1 2 3 4 6 11 CE mark Optional baseplate offers increased thermal performance +SENSE (6) +Vin (4) +Vout (5) SWITCH CONTROL -Vout (9) -Vin (1) PULSE TRANSFORMER PWM CONTROLLER REMOTE ON /OFF CONTROL* (3) OPTO ISOLATION Input undervoltage, input overvoltage, and output overvoltage comparators REFERENCE & -SENSE (8) Vout TRIM (7) ERROR AMP Figure 1. Simplified Schematic Typical topology is shown. Some models may vary slightly. * Can be ordered with positive (standard) or negative (optional) polarity. For full details go to www.murata-ps.com/rohs www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 1 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE Output Input Efficiency VOUT (Volts) IOUT (Amps, Max.) (Watts) Typ. Max. 3.3 70 e 231 100 125 HPH-5/40-D48N-C 5 40 200 100 125 HPH-12/30-D48N-C 12 30 360 Root Model M HPH-3.3/70-D48N-C Power R/N (mV pk-pk) Package VIN Nom. (Volts) Range (Volts) IIN, no load (mA) IIN, full load (Amps) Min. Typ. 0.25% 0.25% 48 36-75 70 5.35 88% 90% C61 P17 0.25% 0.25% 48 36-75 70 4.58 90% 91% C61 P17 Regulation (Max.) Line Load (Case/ Pinout) Please refer to the separate HPH-12/30-D48 data sheet. M Please refer to the full model number structure for additional ordering part numbers and options. N All specifications are at nominal line voltage and full load, +25C. unless otherwise noted. See detailed specifications. O Full power continuous output requires baseplate installation. Please refer to the derating curves. PART NUMBER STRUCTURE HPH - 3.3 / 70 - D48 N B Unipolar High-Power Series Nominal Output Voltage Maximum Output Current in Amps Input Voltage Range: D48 = 36-75 Volts (48V nominal) On/Off Control Polarity N = Negative polarity, standard P = Positive polarity, optional H Lx - C RoHS Hazardous Materials compliance C = RoHS-6 (no lead), standard, does not claim EU exemption 7b - lead in solder Y = RoHS-5 (with lead), optional, special quantity order Pin length option Blank = standard pin length 0.180 in. (4.6 mm) L1 = 0.110 in. (2.79 mm)* L2 = 0.145 in. (3.68 mm)* *Special quantity order required Conformal coating (optional) Blank = no coating, standard H = Coating added, optional, special quantity order Baseplate (optional) Blank = No baseplate, standard B = Baseplate installed, optional quantity order Note: Some model combinations may not be available. Contact Murata Power Solutions for availability. Note: Because of the high currents, wire the appropriate input, output and common pins in parallel. Be sure to use adequate PC board etch. If not sufficient, install additional discrete wiring. On/Off Enable Control Ground Bounce Protection To improve reliability, if you use a small signal transistor or other external circuit to select the Remote On/Off control, make sure to return the LO side directly to the -Vin power input on the DC/DC converter. To avoid ground bounce errors, do not connect the On/Off return to a distant ground plane or current-carrying bus. If necessary, run a separate small return wire directly to the -Vin terminal. There is very little current (typically 1-5 mA) on the On/Off control however, large current changes on a return ground plane or ground bus can accidentally trigger the converter on or off. If possible, mount the On/Off transistor or other control circuit adjacent to the converter. DC/DC Converter + Vin Preferred location of On/Off control adjacent to -Vin terminal On/Off Enable On/Off Control Transistor -Vin return Ground plane or power return bus Install separate return wire for On/Off control with remote transistor Do not connect control transistor through remote power bus Figure 2. On/Off Enable Control Ground Bounce Protection www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 2 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters MECHANICAL SPECIFICATIONS 2.30 (58.4) A User's thermal surface and hardware Recommended threaded insert torque is 0.35-0.55 N-M or 3-5 in-lbs. 0.40 (10.2) Do not remove M3 x 0.50 threaded inserts from bottom PCB Baseplate 0.50 (12.7) 0.015 min. clearance between standoffs and highest component 0.18 (4.57) Pin Diameters: Pins 1-4, 6-8 Pins 5, 9 1.900 (48.26) A 0.040 0.001 (1.016 0.025) 0.080 0.001 (2.032 0.025) 0.015 minimum clearance between standoffs and highest component 0.18 (4.6) 0.20 (5.1) 2.30 (58.4) 1.90 (48.3) B 1 9 2 M3 x 0.50 threaded insert and standoff (4 places) 8 Case C61 7 3 6 0.400 (10.16) 4 0.700 (17.78) 1.000 (25.40) 1.400 (35.56) 2.40 (60.96) Screw length must not go through Baseplate 2.00 (50.8) 2.40 (61.0) 5 0.50 (12.70) Bottom View HPH with Optional Baseplate B Dimensions are in inches (mm) shown for ref. only. Third Angle Projection INPUT/OUTPUT CONNECTIONS Pin Function P17 1 Negative Input 2 Case* 3 On/Off Control 4 Positive Input 5 Positive Output 6 Positive Sense 7 Trim 8 Negative Sense 9 Negative Output Pin 2 may be removed under special order. Please contact Murata Power Solutions. Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 2 Components are shown for reference only. Since there is some pin numbering inconsistency between manufacturers of half brick converters, be sure to follow the pin function, not the pin number, when laying out your board. Standard pin length is shown. Please refer to the Part Number Structure for special order pin lengths. * Note that the "case" connects to the baseplate (when installed). This case connection is isolated from the rest of the converter. Pin 2 may be deleted under special order. Please contact Murata Power Solutions for information. The Trim connection may be left open and the converter will achieve its rated output voltage. www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 3 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters INPUT CHARACTERISTICS Model Family Start-up UnInput Current 1 threshold dervolt- Reflected age (back) Ripple Inrush Output No Low Current ShutTyp. Tran- Short Load Line down12 sient Circuit mA mA A V V mA pk-pk A2sec HPH-3.3/70-D48 35 33.5 20 0.1 50 70 Remote On/Off Control 6 Reverse Internal Polarity Current Standby Input 16 Mode Filter Type Protection (Max.) mA 7.13 1 Pi-type HPH-5/40-D48 35 33.5 20 0.05 50 70 6.11 4 Positive Logic Negative Logic mA "P" model suffix "N" model suffix 2 OFF=Gnd. pin to +1V Max. ON=open pin or +3.5 to +13.5V Max. OFF=open pin or +3.5V to +13.5V Max. ON=Gnd. pin to +1V Max. 2 OFF=Gnd. pin to +1V Max. ON=open pin or +3.5 to +13.5V Max. OFF=open pin or +3.5V to +13.5V Max. ON=Gnd. pin to +1V Max. See notes OUTPUT CHARACTERISTICS VOUT Accuracy Model Family 50% Load HPH-3.3/70-D48 HPH-5/40-D48 Ripple/ Remote Sense 11 Noise 9 Over- Compensation Minimum Line/Load Efficiency Voltage Low ESR <0.02 Hiccup auto Protection Loading Regulation 7 Max. (20 MHz Max., resistive restart after Method fault removal load bandwidth) F V % of VOUT No 10,000 4 Magnetic +10 minimum See ordering guide feedback 10,000 6 load Adjustment Temperature Capacitance Overvoltage Range 8 Coefficient Loading Protection 10 15 % of VNOM % of VNOM 1 1 10 10 % of VOUT range/C 0.02 0.02 ISOLATION CHARACTERISTICS Model Family Input to Output Input to baseplate Min. V Min. V 2250 1500 Baseplate to output Isolation Resistance Isolation Capacitance Min. V M pF 1500 100 2000 HPH-3.3/70-D48 HPH-5/40-D48 Isolation Safety Rating Basic Insulation Short Circuit Short Circuit Current Protection Method 98% of VOUT, after warmup Continuous A A Current 84 12 limiting, hiccup 45 hiccup17 autorestart Current Limit Inception See notes on page 5. Soldering Guidelines Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifications may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers. Wave Solder Operations for through-hole mounted products (THMT) For Sn/Ag/Cu based solders: For Sn/Pb based solders: Maximum Preheat Temperature 115 C. Maximum Preheat Temperature 105 C. Maximum Pot Temperature 270 C. Maximum Pot Temperature 250 C. Maximum Solder Dwell Time 7 seconds Maximum Solder Dwell Time 6 seconds www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 4 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters DYNAMIC CHARACTERISTICS Dynamic Load Response, Sec to 1% final value, (50-75-50%, load step) Start-up Time, VIN to VOUT Remote On/Off to VOUT regulated (Max.) Switching Frequency HPH-3.3/70-D48 HPH-5/40-D48 HPH-3.3/70-D48, HPH-5/40-D48 HPH-3.3/70-D48, HPH-5/40-D48 HPH-3.3/70-D48 HPH-5/40-D48 Calculated MTBF Operating Temperature Range Storage Temperature Range Thermal Protection/Shutdown Relative Humidity Pre-biased Startup 150S 200S 10 mS 10 mS 450 KHz 440 KHz TDB -40 to +85C, see derating curves -55 to +125C 120C To +85C/85%, non condensing VOUT must be VSET PHYSICAL CHARACTERISTICS Outline Dimensions Baseplate Material Pin Material Pin Diameter Pin Finish Weight Electromagnetic Interference (conducted and radiated) (may require external filter) See mechanical specs Aluminum Copper alloy 0.04/0.08" (1.016/2.032mm) Nickel underplate with gold overplate 2 ounces (56.7g) Class B, EN55022/CISPR22 Certified to UL/cUL 60950-1, CSA-C22.2 No.60950-1, IEC/EN 60950-1, 2nd Edition Safety ABSOLUTE MAXIMUM RATINGS Volts, Min. Volts, Max. Continuous Volts, Min. Volts, Max. Input Voltage On/Off Control, referred to -VIN Input Reverse Polarity Protection Output Overvoltage, Max. Storage Temperature Min. Max. -0.3V 75V continuous -0.3V +15V See fuse section VOUT + 20% -55C 125C SPECIFICATION NOTES [1] All specifications are typical unless noted. Ambient temperature = +25 degrees Celsius, Vin is nominal (+48 Volts), output current is maximum rated nominal. Output capacitance is 1 F ceramic paralleled with 10 F electrolytic. Input caps are 22 F except HPH-3.3/70-D48 which is 100 F input. All caps are low ESR. These capacitors are necessary for our test equipment and may not be needed in your application. Testing must be kept short enough that the converter does not appreciably heat up during testing. For extended testing, use plenty of airflow. See Derating Curves for temperature performance. All models are stable and regulate within spec without external cacacitance. [2] Input Ripple Current is tested and specified over a 5-20 MHz bandwidth and uses a special set of external filters only for the Ripple Current specifications. Input filtering is Cin = 33 F, Cbus = 220 F, Lbus = 12 H except HPH-3.3/70-D48 is Cin = 100F. Use capacitor rated voltages which are twice the maximum expected voltage. Capacitors must accept high speed AC switching currents. [7] Regulation specifications describe the deviation as the input line voltage or output load current is varied from a nominal midpoint value to either extreme. [8] Do not exceed maximum power ratings, Sense limits or output overvoltage when adjusting output trim values. [9] At zero output current, Vout may contain components which slightly exceed the ripple and noise specifications. [10] Output overload protection is non-latching. When the output overload is removed, the output will automatically recover. [11] Because of the high currents, wire the appropriate input, output and common pins in parallel groups. Be sure to use adequate PC board etch. If not sufficient, install additional discrete wiring. If wiring is not sufficient, the Sense feedback may attempt to drive the outputs beyond ratings. [3] Note that Maximum Current Derating Curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the converter will tolerate brief full current outputs if the total RMS current over time does not exceed the Derating curve. [12] The converter will shut off if the input falls below the undervoltage threshold. It will not restart until the input exceeds the Input Start Up Voltage. [4] Mean Time Before Failure (MTBF) is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions. TPCBOARD = +25 C., full output load, natural air convection. [14] Output noise may be further reduced by installing an external filter. See the Application Notes. [5] The output may be shorted to ground indefinitely with no damage. [16] To protect against accidental input voltage polarity reversal, install a fuse in series with +Vin. See Fusing information. 6] The On/Off Control is normally driven from a switch or relay. An open collector/open drain transistor may be used in saturation and cut-off (pinch-off) modes. External logic may also be used if voltage levels are fully compliant to the specifications. [13] Please refer to the separate output capacitive load application note from Murata Power Solutions. [15] To avoid damage or unplanned shutdown, avoid sinking reverse output current. [17] HPH-5/40-D48 full current hiccup is approximately 3% duty cycle, 0.8 Hz pulse rate. www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 5 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters APPLICATION NOTES Input Fusing Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. For greatest safety, we recommend a fast blow fuse installed in the ungrounded input supply line. The installer must observe all relevant safety standards and regulations. For safety agency approvals, install the converter in compliance with the end-user safety standard. Input Reverse-Polarity Protection If the input voltage polarity is reversed, an internal diode will become forward biased and likely draw excessive current from the power source. If this source is not current-limited or the circuit appropriately fused, it could cause permanent damage to the converter. Input Under-Voltage Shutdown and Start-Up Threshold Under normal start-up conditions, converters will not begin to regulate properly until the ramping-up input voltage exceeds and remains at the Start-Up Threshold Voltage (see Specifications). Once operating, converters will not turn off until the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent restart will not occur until the input voltage rises again above the Start-Up Threshold. This built-in hysteresis prevents any unstable on/off operation at a single input voltage. Users should be aware however of input sources near the Under-Voltage Shutdown whose voltage decays as input current is consumed (such as capacitor inputs), the converter shuts off and then restarts as the external capacitor recharges. Such situations could oscillate. To prevent this, make sure the operating input voltage is well above the UV Shutdown voltage AT ALL TIMES. performance is improved by adding external filter components. Sometimes only a small ceramic capacitor is sufficient. Since it is difficult to totally characterize all applications, some experimentation may be needed. Note that external input capacitors must accept high speed switching currents. Because of the switching nature of DC/DC converters, the input of these converters must be driven from a source with both low AC impedance and adequate DC input regulation. Performance will degrade with increasing input inductance. Excessive input inductance may inhibit operation. The DC input regulation specifies that the input voltage, once operating, must never degrade below the Shut-Down Threshold under all load conditions. Be sure to use adequate trace sizes and mount components close to the converter. I/O Filtering, Input Ripple Current and Output Noise All models in this converter series are tested and specified for input reflected ripple current and output noise using designated external input/output components, circuits and layout as shown in the figures below. External input capacitors (Cin in the figure) serve primarily as energy storage elements, minimizing line voltage variations caused by transient IR drops in the input conductors. Users should select input capacitors for bulk capacitance (at appropriate frequencies), low ESR and high RMS ripple current ratings. In the figure below, the Cbus and Lbus components simulate a typical DC voltage bus. Your specific system configuration may require additional considerations. Please note that the values of Cin, Lbus and Cbus will vary according to the specific converter model. In critical applications, output ripple and noise (also referred to as periodic and TO OSCILLOSCOPE VIN Start-Up Time Assuming that the output current is set at the rated maximum, the Vin to Vout Start-Up Time (see Specifications) is the time interval between the point when the ramping input voltage crosses the Start-Up Threshold and the fully loaded regulated output voltage enters and remains within its specified accuracy band. Actual measured times will vary with input source impedance, external input capacitance, input voltage slew rate and final value of the input voltage as it appears at the converter. These converters include a soft start circuit to moderate the duty cycle of its PWM controller at power up, thereby limiting the input inrush current. The On/Off Remote Control interval from On command to Vout regulated assumes that the converter already has its input voltage stabilized above the Start-Up Threshold before the On command. The interval is measured from the On command until the output enters and remains within its specified accuracy band. The specification assumes that the output is fully loaded at maximum rated current. Similar conditions apply to the On to Vout regulated specification such as external load capacitance and soft start circuitry. + - + - CURRENT PROBE 4 +INPUT LBUS CBUS CIN 1 -INPUT CIN = 33F, ESR < 700m @ 100kHz CBUS = 220F, ESR < 100m @ 100kHz LBUS = 12H Figure 3. Measuring Input Ripple Current random deviations or PARD) may be reduced by adding filter elements such as multiple external capacitors. Be sure to calculate component temperature rise from reflected AC current dissipated inside capacitor ESR. Our Application Engineers can recommend potential solutions. In figure 4, the two copper strips simulate real-world printed circuit impedances between the power supply and its load. In order to minimize circuit errors and standardize tests between units, scope measurements should be made using BNC connectors or the probe ground should not exceed one half inch and soldered directly to the fixture. Input Source Impedance These converters will operate to specifications without external components, assuming that the source voltage has very low impedance and reasonable input voltage regulation. Since real-world voltage sources have finite impedance, www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 6 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters +SENSE +OUTPUT 6 COPPER STRIP 5 C1 -OUTPUT -SENSE Note that the temperatures are of the ambient airflow, not the converter itself which is obviously running at higher temperature than the outside air. Also note that very low flow rates (below about 25 LFM) are similar to "natural convection", that is, not using fan-forced airflow. C2 SCOPE RLOAD 9 8 COPPER STRIP C1 = 0.1F CERAMIC C2 = 10F TANTALUM LOAD 2-3 INCHES (51-76mm) FROM MODULE Figure 4. Measuring Output Ripple and Noise (PARD) Floating Outputs Since these are isolated DC/DC converters, their outputs are "floating" with respect to their input. The essential feature of such isolation is ideal ZERO CURRENT FLOW between input and output. Real-world converters however do exhibit tiny leakage currents between input and output (see Specifications). These leakages consist of both an AC stray capacitance coupling component and a DC leakage resistance. When using the isolation feature, do not allow the isolation voltage to exceed specifications. Otherwise the converter may be damaged. Designers will normally use the negative output (-Output) as the ground return of the load circuit. You can however use the positive output (+Output) as the ground return to effectively reverse the output polarity. Minimum Output Loading Requirements These converters employ a synchronous rectifier design topology. All models regulate within specification and are stable under no load to full load conditions. Operation under no load might however slightly increase output ripple and noise. Thermal Shutdown To prevent many over temperature problems and damage, these converters include thermal shutdown circuitry. If environmental conditions cause the temperature of the DC/DC's to rise above the Operating Temperature Range up to the shutdown temperature, an on-board electronic temperature sensor will power down the unit. When the temperature decreases below the turn-on threshold, the converter will automatically restart. There is a small amount of hysteresis to prevent rapid on/off cycling. The temperature sensor is typically located adjacent to the switching controller, approximately in the center of the unit. See the Performance and Functional Specifications. CAUTION: If you operate too close to the thermal limits, the converter may shut down suddenly without warning. Be sure to thoroughly test your application to avoid unplanned thermal shutdown. Temperature Derating Curves The graphs in the next section illustrate typical operation under a variety of conditions. The Derating curves show the maximum continuous ambient air temperature and decreasing maximum output current which is acceptable under increasing forced airflow measured in Linear Feet per Minute ("LFM"). Note that these are AVERAGE measurements. The converter will accept brief increases in temperature and/or current or reduced airflow as long as the average is not exceeded. MPS makes Characterization measurements in a closed cycle wind tunnel with calibrated airflow. We use both thermocouples and an infrared camera system to observe thermal performance. As a practical matter, it is quite difficult to insert an anemometer to precisely measure airflow in most applications. Sometimes it is possible to estimate the effective airflow if you thoroughly understand the enclosure geometry, entry/exit orifice areas and the fan flowrate specifications. If in doubt, contact MPS to discuss placement and measurement techniques of suggested temperature sensors. CAUTION: If you routinely or accidentally exceed these Derating guidelines, the converter may have an unplanned Over Temperature shut down. Also, these graphs are all collected at slightly above Sea Level altitude. Be sure to reduce the derating for higher density altitude. Output Overvoltage Protection This converter monitors its output voltage for an over-voltage condition using an on-board electronic comparator. The signal is optically coupled to the primary side PWM controller. If the output exceeds OVP limits, the sensing circuit will power down the unit, and the output voltage will decrease. After a time-out period, the PWM will automatically attempt to restart, causing the output voltage to ramp up to its rated value. It is not necessary to power down and reset the converter for this automatic OVP-recovery restart. If the fault condition persists and the output voltage climbs to excessive levels, the OVP circuitry will initiate another shutdown cycle. This on/off cycling is referred to as "hiccup" mode. It safely tests full current rated output voltage without damaging the converter. Output Fusing The converter is extensively protected against current, voltage and temperature extremes. However your output application circuit may need additional protection. In the extremely unlikely event of output circuit failure, excessive voltage could be applied to your circuit. Consider using an appropriate fuse in series with the output. Output Current Limiting As soon as the output current increases to approximately 125% to 150% of its maximum rated value, the DC/DC converter will enter a current-limiting mode. The output voltage will decrease proportionally with increases in output current, thereby maintaining a somewhat constant power output. This is commonly referred to as power limiting. Current limiting inception is defined as the point at which full power falls below the rated tolerance. See the Performance/Functional Specifications. Note particularly that the output current may briefly rise above its rated value. This enhances reliability and continued operation of your application. If the output current is too high, the converter will enter the short circuit condition. Output Short Circuit Condition When a converter is in current-limit mode, the output voltage will drop as the output current demand increases. If the output voltage drops too low, the magnetically coupled voltage used to develop primary side voltages will also drop, thereby shutting down the PWM controller. Following a time-out period, www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 7 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters the PWM will restart, causing the output voltage to begin ramping up to its appropriate value. If the short-circuit condition persists, another shutdown cycle will initiate. This on/off cycling is called "hiccup mode". The hiccup cycling reduces the average output current, thereby preventing excessive internal temperatures. A short circuit can be tolerated indefinitely. Remote Sense Input Sense inputs compensate for output voltage inaccuracy delivered at the load. This is done by correcting voltage drops along the output wiring such as moderate IR drops and the current carrying capacity of PC board etch. Sense inputs also improve the stability of the converter and load system by optimizing the control loop phase margin. Note: The Sense input and power Vout lines are internally connected through low value resistors to their respective polarities so that the converter can operate without external connection to the Sense. Nevertheless, if the Sense function is not used for remote regulation, the user should connect +Sense to +Vout and -Sense to -Vout at the converter pins. The remote Sense lines carry very little current. They are also capacitively coupled to the output lines and therefore are in the feedback control loop to regulate and stabilize the output. As such, they are not low impedance inputs and must be treated with care in PC board layouts. Sense lines on the PCB should run adjacent to DC signals, preferably Ground. In cables and discrete wiring, use twisted pair, shielded tubing or similar techniques Please observe Sense inputs tolerance to avoid improper operation: a single fixed resistor connected between the Trim input and either the +Sense or -Sense terminals. (On some converters, an external user-supplied precision DC voltage may also be used for trimming). Trimming resistors should have a low temperature coefficient (100 ppm/deg.C or less) and be mounted close to the converter. Keep leads short. If the trim function is not used, leave the trim unconnected. With no trim, the converter will exhibit its specified output voltage accuracy. There are two CAUTION's to be aware for the Trim input: CAUTION: To avoid unplanned power down cycles, do not exceed EITHER the maximum output voltage OR the maximum output power when setting the trim. Be particularly careful with a trimpot. If the output voltage is excessive, the OVP circuit may inadvertantly shut down the converter. If the maximum power is exceeded, the converter may enter current limiting. If the power is exceeded for an extended period, the converter may overheat and encounter overtemperature shut down. CAUTION: Be careful of external electrical noise. The Trim input is a senstive input to the converter's feedback control loop. Excessive electrical noise may cause instability or oscillation. Keep external connections short to the Trim input. Use shielding if needed. Also consider adding a small value ceramic capacitor between the Trim and -Vout to bypass RF and electrical noise. 1 -INPUT 5 +OUTPUT [Vout(+) -Vout(-)] - [ Sense(+) - Sense(-)] 10% of Vout 1 -INPUT +OUTPUT +SENSE +SENSE Contact and PCB resistance losses due to IR drops 5 6 3 I OUT ON/OFF CONTROL Sense Current 3 ON/OFF CONTROL TRIM 7 LOAD 4 -SENSE +INPUT 8 7 5-22 TURNS TRIM -SENSE Sense Return 6 LOAD 8 9 -OUTPUT I OUT Return 4 +INPUT -OUTPUT Figure 6. Trim adjustments using a trimpot 9 Contact and PCB resistance losses due to IR drops 5 +OUTPUT 1 Figure 5. Remote Sense Circuit Configuration -INPUT Output overvoltage protection is monitored at the output voltage pin, not the Sense pin. Therefore excessive voltage differences between Vout and Sense together with trim adjustment of the output can cause the overvoltage protection circuit to activate and shut down the output. 6 +SENSE 3 Power derating of the converter is based on the combination of maximum output current and the highest output voltage. Therefore the designer must insure: (Vout at pins) x (Iout) (Max. rated output power) Trimming the Output Voltage The Trim input to the converter allows the user to adjust the output voltage over the rated trim range (please refer to the Specifications). In the trim equations and circuit diagrams that follow, trim adjustments use either a trimpot or ON/OFF CONTROL TRIM +INPUT LOAD R TRIM UP -SENSE 4 7 -OUTPUT 8 9 Figure 7. Trim adjustments to Increase Output Voltage using a Fixed Resistor www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 8 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters 1 +OUTPUT Negative: Optional negative-polarity devices are on (enabled) when the On/Off is grounded or brought to within a low voltage (see Specifications) with respect to -Vin. The device is off (disabled) when the On/Off is pulled high to +Vin with respect to -Vin. 5 -INPUT 6 +SENSE 3 ON/OFF CONTROL TRIM LOAD +INPUT R TRIM DOWN -SENSE 4 7 +INPUT -OUTPUT 8 3 ON/OFF CONTROL 9 Figure 8. Trim adjustments to Decrease Output Voltage using a Fixed Resistor Radj_up (in k) = Vnominal x (1+) - 1 - 2 1.225 x where = 1 -INPUT Figure 10. Driving the Negative Polarity On/Off Control Pin Vout -Vnominal Vnominal Dynamic control of the On/Off function should be able to sink appropriate signal current when brought low and withstand appropriate voltage when brought high. Be aware too that there is a finite time in milliseconds (see Specifications) between the time of On/Off Control activation and stable, regulated output. This time will vary slightly with output load type and current and input conditions. 1 -2 Vnominal -Vout Vnominal Radj_down (in k) = where = +VCC 4 There are two CAUTIONs for the On/Off Control: Trim Equations Where Vref = +1.225 Volts and is the desired output voltage change. Note that "" is given as a small fraction, not a percentage. A single resistor connected between Trim and +Sense will increase the output voltage. A resistor connected between Trim and -Sense will decrease the output. Remote On/Off Control On the input side, a remote On/Off Control can be ordered with either polarity. Positive: Standard models are enabled when the On/Off pin is left open or is pulled high to +Vin with respect to -Vin. An internal bias current causes the open pin to rise to +Vin. Some models will also turn on at lower intermediate voltages (see Specifications). Positive-polarity devices are disabled when the On/Off is grounded or brought to within a low voltage (see Specifications) with respect to -Vin. + Vcc CAUTION: While it is possible to control the On/Off with external logic if you carefully observe the voltage levels, the preferred circuit is either an open drain/open collector transistor or a relay (which can thereupon be controlled by logic). CAUTION: Do not apply voltages to the On/Off pin when there is no input power voltage. Otherwise the converter may be permanently damaged. NOTICE--Please use only this customer data sheet as product documentation when laying out your printed circuit boards and applying this product into your application. Do NOT use other materials as official documentation such as advertisements, product announcements, or website graphics. We strive to have all technical data in this customer data sheet highly accurate and complete. This customer data sheet is revision-controlled and dated. The latest customer data sheet revision is normally on our website (www.murataps.com) for products which are fully released to Manufacturing. Please be especially careful using any data sheets labeled "Preliminary" since data may change without notice. ON/OFF CONTROL The pinout (Pxx) and case (Cxx) designations refer to a generic family of closely related information. It may not be a single pinout or unique case outline. Please be aware of small details (such as Sense pins, Power Good pins, etc.) or slightly different dimensions (baseplates, heat sinks, etc.) which may affect your application and PC board layouts. Study the Mechanical Outline drawings, Input/Output Connection table and all footnotes very carefully. Please contact Murata Power Solutions if you have any questions. CONTROL -INPUT Figure 9. Driving the Positive Polarity On/Off Control Pin www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 9 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters Vertical Wind Tunnel ,E/A>A>AiI IV>EUU 1IEOiA IiAIE11/(R) Murata Power Solutions employs a custom-designed enclosed vertical wind tunnel, infrared video camera system and test instrumentation for accurate airflow and heat dissipation analysis of power products. The system includes a precision low flow-rate anemometer, variable speed fan, power supply input and load controls, temperature gauges and adjustable heating element. 6>A>Li AiiEv> The IR camera can watch thermal characteristics of the Unit Under Test (UUT) with both dynamic loads and static steadystate conditions. A special optical port is used which is transparent to infrared wavelengths. The computer files from the IR camera can be studied for later analysis. ,E6iE >iA> i>I}E iiiI *AiVA UA>Ii >iiIiA IELiUE11/ LiIE IiiA>IOAi AiAA AvU V>IA Figure 11. Vertical Wind Tunnel Both through-hole and surface mount converters are soldered down to a host carrier board for realistic heat absorption and spreading. Both longitudinal and transverse airflow studies are possible by rotation of this carrier board since there are often significant differences in the heat dissipation in the two airflow directions. The combination of both adjustable airflow, adjustable ambient heat and adjustable Input/Output currents and voltages mean that a very wide range of measurement conditions can be studied. The airflow collimator mixes the heat from the heating element to make uniform temperature distribution. The collimator also reduces the amount of turbulence adjacent to the UUT by restoring laminar airflow. Such turbulence can change the effective heat transfer characteristics and give false readings. Excess turbulence removes more heat from some surfaces and less heat from others, possibly causing uneven overheating. Both sides of the UUT are studied since there are different thermal gradients on each side. The adjustable heating element and fan, built-in temperature gauges and no-contact IR camera mean that power supplies are tested in realworld conditions. www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 10 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters Transient Response - Model HPH-3.3/70-D48 Figure 12. Transient Response (25% Load Step) Figure 13. Transient Response (50% Load Step) Enable Start-up - Model HPH-3.3/70-D48 Figure 14. Enable Start-up (VIN=48V IOUT=0A) Figure 15. Enable Start-up (VIN=48V IOUT=70A) Ripple and Noise (1uF Ceramic plus 10uF Tantalum) - Model HPH-3.3/70-D48 Figure 16. Ripple Waveform (VIN=48V IOUT=0A) Figure 17. Ripple Waveform (VIN=48V IOUT=70A) www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 11 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters Typical Performance Curves HPH-3.3/70-D48 Efficiency and Power Dissipation Vs. Load Current @ +25C HPH-3.3/70-D48 Maximum Current Temperature Derating (VIN=48V, Airflow is from VIN to VOUT, no baseplate) 94 75 70 65 60 55 50 45 40 35 30 25 20 15 10 92 Output Current (Amps) Efficiency (%) 90 VIN = 36 V VIN = 50 V VIN = 75 V 88 86 84 82 80 78 76 10 20 30 40 50 60 70 100 LFM 200 LFM 300 LFM 400 LFM 30 35 40 45 Load Current (Amps) 50 55 60 65 70 75 80 75 80 Ambient Temperature (C) HPH-3.3/70-D48 Maximum Current Temperature Derating (VIN=48V, Airflow is from VIN to VOUT, with baseplate) 80 70 Output Current (Amps) 60 50 40 30 100 LFM 200 LFM 300 LFM 400 LFM 20 10 0 30 35 40 45 50 55 60 65 70 75 80 Ambient Temperature (C) HPH-5/40-D48 Maximum Current Temperature Derating (VIN=48V, Airflow is from VIN to VOUT, no baseplate) VIN = 75V VIN = 48V VIN = 36V Power Dissipation @ VIN = 48V 0 5 10 15 20 25 Load Current (Amps) 30 35 26 24 22 20 18 16 14 12 10 8 6 4 2 0 40 Output Current (Amps) 96 94 92 90 88 86 84 82 80 78 76 74 72 70 Loss (Watts) Efficiency (%) HPH-5/40-D48 Efficiency and Power Dissipation Vs. Load Current @ +25C 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 100 LFM 200 LFM 300 LFM 400 LFM 30 35 40 45 50 55 60 65 70 Ambient Temperature (C) www.murata-ps.com email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 12 of 13 HPH Series Isolated, Low VOUT to 70A, Half-Brick DC/DC Converters Typical Performance Curves, Continued HPH-12/30-D48 Maximum Current Temperature Derating at Sea Level (Vin = 48V, Airflow is from input to output, baseplate is installed) 48 95 40 90 32 VIN = 75V VIN = 48V VIN = 36V 85 24 80 16 75 8 Power Dissipation @ Vin = 48V 35 30 Output Current (Amps) 100 Loss (Watts) Efficiency (%) HPH-12/30-D48 Efficiency and Power Dissipation Vs. Line Voltage and Load Current @ +25C 25 20 15 Natural convection 100 LFM 200 LFM 300 LFM 400 LFM 10 5 70 0 3 6 9 12 15 18 Load Current (Amps) 21 24 27 30 0 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (C) Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2010 Murata Power Solutions, Inc. www.murata-ps.com/locations email: sales@murata-ps.com 17 Sep 2010 MDC_HPH_A18 Page 13 of 13