reserved Schutzvermerk nach DIN 34 beachten Copyright 10.2000 23. @)Bernstein{ Technical data sheet _ PE woe | Ti 2-SU1Z Riw | 608.8167.008_ Seace EQ Positive opening operation accordin to DIN EN 60947-5-1 IEC 947-5-1 210 GS {B, A 19 10.5 Omm 0.6 45 ! pf I = I ! . Y 13-17 14 a | Gs.5 Pg9Q se} 12 1 ann 21 wr 22 _ 30, _ 27, tit Switching Switching diagram symbo | Tolerance: operating point +0.25mm; actuating force +10% \ Mechanical features Enclosure: PBT, glass fibre reinforced Cover: PA6.6, black Actuator: Roller (Thermoplast ) Ambient air temperature: -30C up to +80C Contact type: 1 NC-contact, 1 NO-contact (Zb) Galvanic isolation of contacts: Switching circuits with different electrical potential Mechanical life: 3x10 switch operations Switch frequency: max. 100/min Mounting: 2xM4 or 2xM5 fixed positioning for safety applications Connection type: 4 screw connections (M3.5) Conductor cross-section: single core 0.5-1.5mm? / litz wire with connector sleeve 0.5-1.5mm? Cable entry size: 1 x Pg9 Weight: approx. 0,05kg Electrical features Max. voltage: 250 V AC Max. enduring current: | th 10A Max. inrush current: according to IEC 947-5-1 Utilization categorie: AC 15,A300 240V/3A, 120V/6A / DC 13,Q300 250V/0.27A, 125V/0.55A Standards: according to EN 60947-1; EN 60947-5-1 Protection class (IP-Code): IP65 according to EN 60529; DIN VDE 0470 T1 CSA/UL: 10A 300V AC, A300 Short-circuit protection: Fuse 6A gL/gG, IEC/EN 60947-5-1, appendix K Approach possibilities Actuator not re-arrangeble Remarks The moving parts should be oiled periodically. The planned protection class (IP-Code) is valid only at closed cover and when using an at least equivalent cable gland. Copies are not retreated in case of alternations