Data sheet... Surge protection SPD II 2 PV 1000VDC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Surge protection for use on the DC side of photovoltaic installations. The SPD II PV series is tested according to UL 1449 ed. 3 (file E354261) as type 4 for use in type 2 applications. This series is assembled according to the respective PV voltage (600 V, 1000 V, 1200 V) and has a nominal discharge current of up to 50 kA (8/20 s) per path. The SPD II has a compact and modular structure and a standard module width of 17.8 mm; it allows rapid and simple exchange of the varistor protection. The SPD PV arrestor consists of 2 elements. General ordering data Order No. Type Version GTIN (EAN) Qty. 1348490000 SPD II 2 PV 1000VDC Surge protection, Low voltage 4050118152906 1 pc(s). Creation date April 29, 2013 5:37:37 PM CEST Catalogue status 12.03.2013 / We reserve the right to make technical changes. 1 Data sheet... Surge protection SPD II 2 PV 1000VDC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights Width Depth 36 mm 73.5 mm Height Net weight 90 mm 288 g -40 C...+70 C Storage temperature -40 C...+85 C Light Grey 74 mm TS 35, TS 35 x 15, TS 35 x 7.5 IP 20 Design Lightning arrester Optical function display UL 94 flammability rating Installation housing; 2TE No green = OK; red = arrester is defective - replace V-0 2 Surge voltage category III 1000 V 20 kA Light Grey 100 ns Total discharge current Itotal Protection level UP (typ.) AC/DC/UC 40 kA 4000 V DC Temperatures Operating temperature General data Colour Height with TS 35 Mounting rail Protection degree Insulation coordination acc. to EN 50178 Pollution severity technical data Max. continuous voltage, Uc (DC) Discharge current, max. (8/20 s) Colour Response time Connection data Clamping range, rated connection 25 mm Clamping range, rated connection, max. 35 mm Wire connection cross section, stranded, rated connection, max. 25 mm Tightening torque, max. 3 Nm Clamping range, rated connection, min. 4 mm Wire connection cross section, stranded, rated connection, min. 2.5 mm Tightening torque, min. 2.5 Nm Stripping length, rated connection 15 mm Photovoltaic technical data Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE 1,000 V DC Protection level Up mode (+/- , -/PE , +/ PE) 4000 V Protection level Up at In (per module) 4000 V Rated data UL Category In SCCR UL certificate Typ 2 10 kA 200 kA E-File 354261 Type 2 by UL1449 Ed.3 Imax MCOV Test Voltage 39.1 (UL 1449) VPR 20 kA 1,000 Vdc 1,000 V EC000941 27-13-08-01 27-14-02-01 UNSPSC eClass 6.2 30-21-19-21 27-13-08-02 4V Classifications ETIM 3.0 eClass 5.1 eClass 7.1 Creation date April 29, 2013 5:37:37 PM CEST Catalogue status 12.03.2013 / We reserve the right to make technical changes. 2 Data sheet... Surge protection SPD II 2 PV 1000VDC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Approvals Approvals ROHS Conform Downloads Declaration of Conformity EPLAN K481_05_12.pdf 1348490000.ema Creation date April 29, 2013 5:37:37 PM CEST Catalogue status 12.03.2013 / We reserve the right to make technical changes. 3 Data sheet... Surge protection SPD II 2 PV 1000VDC Drawings Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Electric symbol Circuit diagram Creation date April 29, 2013 5:37:37 PM CEST Catalogue status 12.03.2013 / We reserve the right to make technical changes. 4