PRODUCT SPECIFICATION
REVISION:
ECR/ECN INFORMATION:
TITLE:
PRODUCT SPECIFICATION
0.30MM CENTER FFC JUMPER CABLE
SHEET No.
A EC No:
USW2012-0123
1 of 5
DATE:
2011/11/01
DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY:
PS-15015-001 M. Imig J. Wolfsberger S. Fulton
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A4](V.1).DOC
PRODUCT SPECIFICATION OF THE
0.30MM CENTER FFC JUMPER CABLE
Revision List
REVISION MODIFICATION SHEETS DATE
A First Release 1 - 5 2011/11/15
PRODUCT SPECIFICATION
REVISION:
ECR/ECN INFORMATION:
TITLE:
PRODUCT SPECIFICATION
0.30MM CENTER FFC JUMPER CABLE
SHEET No.
A EC No:
USW2012-0123
2 of 5
DATE:
2011/11/01
DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY:
PS-15015-001 M. Imig J. Wolfsberger S. Fulton
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A4](V.1).DOC
1 SCOPE
This specification covers the 0.30mm center FFC (Flat Flexible Cable) jumper
cable, high temperature style, using gold plated copper conductor.
2 PRODUCT DESCRIPTION
2.1 Product name and series number
Product name: 0.30MM CENTER FFC JUMPER CABLE
Product material no: 15015-XXXX
2.2 Dimensions, materials and markings
Product dimensions according SD-15015-001.
Number of conductors ·············· N: 23, 25, 27, 29, 33, 39, 45, & 51
Pitch ············································ P: 0.30 ± 0.05mm
Span ············································ E: 0.30 (N-I) ± 0.10mm
Total width ·································· W: 0.30 (N+I) ± 0.10mm
Margin width ······························· M: 0.30 + 0.15mm/ -0.096mm
Exposed Contacts ·································· S: 3.00mm ± .50mm
End thickness ····························· Tc: 0.80 ± 0.05mm
Thickness - insulated area ······· Ti: 0.12 ± 0.05mm
Length ········································· L: 2.00”, 4.00”, 6.00”, 8.00”, & 10.00” ±.01”
Reinforcement length ··············· F: 4.00 ± .50mm
PRODUCT SPECIFICATION
REVISION:
ECR/ECN INFORMATION:
TITLE:
PRODUCT SPECIFICATION
0.30MM CENTER FFC JUMPER CABLE
SHEET No.
A EC No:
USW2012-0123
3 of 5
DATE:
2011/11/01
DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY:
PS-15015-001 M. Imig J. Wolfsberger S. Fulton
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A4](V.1).DOC
2.3 COMPOSITION
Conductor: Material: Gold plated copper conductor
Thickness: 0.018mm nominal
Insulation tape: Material: Polyimide + Flame retardant adhesive
Thickness: 0.025mm nominal
Color: Orange - Brown
Reinforcement tape:Material: Polyimide + Adhesive
Thickness: 0.135mm nominal
Color: Orange – Brown
2.4 Safety agency approvals
Not applicable.
3 RATINGS
3.1 Current and applicable conductors
3.2 Temperature
Operating temperature: -40°C to +105°C
Cross section Amps
0.0018mm² 0.2
PRODUCT SPECIFICATION
REVISION:
ECR/ECN INFORMATION:
TITLE:
PRODUCT SPECIFICATION
0.30MM CENTER FFC JUMPER CABLE
SHEET No.
A EC No:
USW2012-0123
4 of 5
DATE:
2011/11/01
DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY:
PS-15015-001 M. Imig J. Wolfsberger S. Fulton
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A4](V.1).DOC
4 PERFORMANCE
4.1 Electrical requirements
ITEM DESCRIPTION TEST CONDITION REQUIREMENT
1 Conductor
resistance
20mV Maximum, 10mA
Maximum 60 milliohm Maximum
2
Insulation
resistance cond. to
cond.
250 V DC between adjacent
terminal and ground 50 Mohms Minimum
3 Dielectric test
Mate with molex series 502598
and apply 200 V AC for 1
minute between adjacent
terminal or ground
No disruptive discharge
4 Voltage rating Maximum 30°C heat rise at
mate with Molex series 502598
50 V AC(rms)/DC
MAXIMUM
5 Current rating 0.2 A MAX
4.2 Physical requirements
ITEM DESCRIPTION TEST CONDITION REQUIREMENT
6 Temperature rating -40°C to +105°C
7 Heat resistance
Mate Molex series 502598 and
expose to 85°C for 96 hours.
Upon completion of the
exposure period, the test
specimens shall be
conditioned at ambient room
conditions 1 to 2 hours, after
which the specified
measurements shall be
performed.
1) No Damage
2) contact resistance of 100
milliohm Maximum
8 Thermal shock
Mated Molex series 502598
and subject to the following
conditions for 5 cycles. Upon
completion of the exposure
period, the test specimens
shall be conditioned at ambient
room condition for 1 to 2 hours,
after which the specified
measurements shall be
performed.
1 cycle
30 minutes at –55°C
5 minutes at +25°C
30 minutes at +85°C
5 minutes at +25°C
1) No Damage
2) contact resistance of 100
milliohm Maximum
PRODUCT SPECIFICATION
REVISION:
ECR/ECN INFORMATION:
TITLE:
PRODUCT SPECIFICATION
0.30MM CENTER FFC JUMPER CABLE
SHEET No.
A EC No:
USW2012-0123
5 of 5
DATE:
2011/11/01
DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY:
PS-15015-001 M. Imig J. Wolfsberger S. Fulton
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A4](V.1).DOC
9 Cold coiling
96 hours at –40°C / The
sample will be wound on a
3mm dia. Mandrel
1) Insulation resistance (item
2 above)
2)Dielectric test(item 3
above)
3)Visual inspection
10 Wear by abrasion
Test following EN3475-503
Weight: 500g
Speed: 60 cycles/min
Abrasion tool: 0.13mm dia.
10000 cycles (standard)
1000 cycles (shielded)
MINIMUM
11 Folding
The specimen shall be folded
manually (Bending angle: 180°
/ Radius: 4mm)
20 times
MINIMUM
12 Moisture resistance
Mate with Molex series 502598
and expose to 40°C, relative
humidity 90 to 95% for 96
hours. Upon completion of the
exposure period, the test
specimens shall be
conditioned at ambient room
conditions for 1 hour, after
which the specified
measurements shall be
performed.
1) No Damage
2) contact resistance of 100
milliohm Maximum
3) meet dielectric
requirement (item 3 above)
4) insulation resistance be 20
Mohm Minimum
5 PACKAGING
According to MOLEX packaging specification: PK-15015-001
6 ROHS COMPLIANCE
Cable construction is RoHS compliant. This includes base FFC.