CT
364
CT-RELAYS
ULTRA SMALL
AUTOMOTIVE RELAY
Twin type (8 terminals)
Slim 1c type
17.4
.685
13.5
.531
14
.551
17.4
.685
7.2
.283
13.5
.531
mm inch
FEATURES
• Ultra small size
Twin type: 17.4(L)
×
14.0(W)
×
13.5(H)mm
.685(L)
×
.551(W)
×
.531(H)inch
Slim 1c type: 17.4(L)
×
7.2(W)
×
13.5(H)mm
.685(L)
×
.283(W)
×
.531(H)inch
• Twin (1 Form C
×
2)
F orward/re verse motor control is possib le
with a single relay.
• Simple footprint enables ease of PC
board layout
Coil
terminal
Contact
terminal
= 8 terminals
10 terminals layout
SPECIFICATIONS
Contact
Coil
Characteristics
Arrangement 1 Form C
×
2 (H bridge),
1 Form C
Contact material Silver alloy
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 100m
Ω
Initial contact voltage drop, max. 0.2 V (at 10 A switching)
Rating
Nominal switching
capacity N.O.: 20 A 14 V DC
N.C.: 10 A 14 V DC
Max. carrying current 35 A for 2 minutes,
25 A for 1 hour
(14 V, at 20
°
C 68
°
F)
Expected life
(min. operation)
Mechanical (at 120 cpm) Min. 10
7
Electrical Resistive load Min. 10
5
*
1
Motor load Min. 2
×
10
5
*
2
Min. 10
5
*
3
Nominal operating power 800 mW
Max. operating speed
(at nominal switching capacity) 6 cpm
Initial insulation resistance*
4
Min. 100 M
Ω
(at 500 V DC)
Initial
breakdown
voltage*
5
Between open
contacts 500 Vrms for 1 min.
Between contacts
and coil 500 Vrms for 1 min.
Operate time*
6
(at nominal voltage) (at 20
°
C 68
°
F)Max. 10ms (Initial)
Release time (without diode)*
6
(at nominal voltage) (at 20
°
C 68
°
F)Max. 10ms (Initial)
Shock resistance Functional*
7
Min. 100 m/s
2
{10G}
Destructive*
8
Min. 1,000 m/s
2
{100G}
Vibration
resistance
Functional*
9
10 to 100 Hz,
Min. 44.1m/s
2
{4.5G}
Destructive*
10
10 to 500 Hz,
Min. 44.1m/s
2
{4.5G}
Conditions for opera-
tion, transport and stor-
age*
11
(Not freezing and
condensing at low tem-
perature)
Ambient
temp –40
°
C to +85
°
C
–40
°
F to +185
°
F
Humidity 5 to 85% R.H.
Unit weight Approx. 8.0g .28oz (Twin type)
Approx. 4.0g .14oz (Slim 1c type)
Remarks
* Specifications will vary with foreigh standards certification ratings.
*
1
At nominal switching capacity, operating frequency: 1s ON, 9s OFF
*
2
N.O .: at 5 A (steady), 25 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating fre-
quency: 0.5s ON, 9.5s OFF
*
3
At 25A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF
*
4
Measurement at same location as "Initial breakdown voltage " section
*
5
Detection current: 10mA
*
6
Excluding contact bounce time
*
7
Half-wave pulse of sine wave: 11ms; detection: 10
µ
s
*
8
Half-wave pulse of sine wave: 6ms
*
9
Detection time: 10
µ
s
*
10
Time of vibration for each direction;
X, Y, direction: 2 hours
Z direction: 4 hours
*
11
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
XY
Z
TYPICAL
APPLICATIONS
• Power windows
• Auto door lock
• Power sunroof
• Electrically powered mirrors
ORDERING INFORMATION
CT 1 12AEx.
Contact arrangement
1: 1 Form C
2: 1 Form C × 2 (8 terminals type)
5: 1 Form C × 2 (10 terminals type)
Product name
CT
Standard packing; 1 Form C: Carton(tube package) 30pcs. Case 1,500pcs.
1 Form C × 2: Carton(tube package) 30pcs. Case 900pcs.
12: 12
Coil voltage (V DC)