For more Information
please call
1-800-Belden1
General Description:
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil® (100%
coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall
Beldfoil shield and 18 AWG TC drain wire.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (mm)
424 7x32 TC - Tinned Copper 0.6096
Total Number of Conductors: 8
Insulation
Insulation Material:
Insulation Material Dia. (mm)
PO - Polyolefin 1.016
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
24
Inner Shield Drain Wire Stranding: 7x32
Inner Shield Drain Wire Conductor Material: TC - Tinned Copper
Inner Jacket
Inner Jacket Material:
Inner Jacket Material Nom. Dia. (mm)
PVC - Polyvinyl Chloride 2.8194
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
18 7x26 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Ripcord: Yes
Overall Cable
Overall Cabling Color Code Chart:
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1408R Multi-Conductor - CMR Rated Cable
Number Color
1Brown
2Red
3Orange
4Yellow
Overall Nominal Diameter: 8.788 mm
Pair
Pair Color Code Chart:
Number Color
1Red
2Black
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +75°C
Bulk Cable Weight: 98.221 Kg/Km
Max. Recommended Pulling Tension: 391.442 N
Min. Bend Radius/Minor Axis: 88.900 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMR
CEC/C(UL) Specification: CMG
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1666 Riser
CSA Flame Test: FT4
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
50
Nom. Inductance:
Inductance (µH/m)
0.59058
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
101.711
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/m)
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1408R Multi-Conductor - CMR Rated Cable
190.298
Nominal Velocity of Propagation:
VP (%)
66
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
76.4473
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
19.686
Ind. Pair Nominal Shield DC Resistance @ 20
Deg. C:
52.168 Ohm/km
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
1.05 Amps per conductor @ 25°C
Notes (Overall)
Notes: Pair jackets and shields bonded so both strip simultaneously. Beldfoil® provides high reliability with ease of termination.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1408R 0101000 305 MT 33.112 KG BLACK C 4 #24 PR BFS PVC FS PVC
1408R 010500 152 MT 16.329 KG BLACK PRINT "T19" C 4 #24 PR BFS PVC FS PVC
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 1 Revision Date: 09-25-2012
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1408R Multi-Conductor - CMR Rated Cable