Performance and Functional Specifi cations
See Note 1
Input
Input Voltage Range See Ordering Guide and Note 7.
Isolation Not isolated
Start-Up Voltage 4.2 V
Undervoltage Shutdown (see Note 15) 3.4 V
Overvoltage Shutdown None
Refl ected (Back) Ripple Current (Note 2) 49 mA pk-pk
Internal Input Filter Type Capacitive
Recommended External Fuse 4A
Reverse Polarity Protection None, install external fuse
Input Current:
Full Load Conditions See Ordering Guide
Inrush Transient 0.16 A2Sec.
Shutdown Mode (Off, UV, OT) 1 mA
Output in Short Circuit 5 mA
Low Line (Vin=Vmin) 2.24 A.
Remote On/Off Control (Note 5)
Negative Logic ON = Open pin or -0.2V to +0.3V. max.
OFF = +3.5V min. to +Vin max.
Positive Logic ON = Open pin (internally pulled up) or
+3.5V to +Vin max.
OFF = -0.3V to +0.4V. max. or ground
Current 1 mA max.
Tracking/Sequencing (optional) See technical note on page 16
Slew Rate 2 Volts per millisecond, max.
Tracking accuracy, rising input Vout = ±100 mV of Sequence In
Tracking accuracy, falling input Vout = ±100 mV of Sequence In
Output
Output Power 16.5W max.
Output Voltage Range See Ordering Guide
Minimum Loading No minimum load
Accuracy (50% load, untrimmed) ±1.5 % of Vnominal
Voltage Output Range (Note 13) See Ordering Guide
Overvoltage Protection (Note 16) None
Temperature Coeffi cient ±0.02% per °C of Vout range
Ripple/Noise (20 MHz bandwidth) See Ordering Guide and note 8
Line/Load Regulation See Ordering Guide and note 10
Effi ciency See Ordering Guide
Maximum Capacitive Loading (Note 14)
Cap-ESR=0.001 to 0.01 Ohms 200 F
Cap-ESR >0.01 Ohms TBD
Current Limit Inception (Note 6)
(98% of Vout setting, after warm up) 6 Amps
Short Circuit Mode
Short Circuit Current Output 10 mA
Protection Method Hiccup autorecovery upon overload
removal. (Note 17)
Short Circuit Duration Continuous, no damage
(output shorted to ground)
Prebias Startup Converter will start up if the external
output voltage is less than Vnominal.
Power Good output open drain confi guration, 5 mA sink max.
PGood TRUE (HI) (Vset -10%) < Vout < (Vset +10%)
PGood FALSE (LO) 0.0V < Vout < 0.4V. See App. note.
External pullup voltage +5V max., referred to -Vin
Dynamic Characteristics
Dynamic Load Response 200Sec max. to within ±2% of fi nal value
(50-100% load step, di/dt=1A/µSec) (Note 1)
Peak Deviation 250 mV
Start-Up Time 6 mSec for Vout=nominal (Vin On)
(Vin on or On/Off to Vout regulated) 6 mSec for Vout=nominal (Remote On/Off)
Switching Frequency 600 KHz
Environmental
Calculated MTBF (hours) OKL-T/3-W12 OKL2-T/3-W12
Telecordia method (4a) 10,011,000 9,227,000
Calculated MTBF (hours)
MIL-HDBK-217N2 method (4b) 5,549,000 4,860,000
Operating Temperature Range (Ambient, vertical mount)
See derating curves -40 to +85 °C. with derating (Note 9)
Storage Temperature Range -55 to +125 °C.
Thermal Protection/Shutdown Included in PWM
MSL Rating 2
Relative Humidity to 85%/+85 °C., non-condensing
Physical
Outline Dimensions See Mechanical Specifi cations
Weight 0.06 ounces (1.6 grams)
Safety Certifi ed to UL/cUL 60950-1, CSA-
C22.2 No. 60950-1, IEC/EN 60950-1,
2nd Edition
Restriction of Hazardous Substances RoHS-6 (does not claim EU RoHS exemption
7b–lead in solder)
Absolute Maximum Ratings
Input Voltage (Continuous or transient) 0 V. to +15 Volts max.
On/Off Control 0 V. min. to +Vin max.
Input Reverse Polarity Protection None, install external fuse
Output Current (Note 7) Current-limited. Devices can withstand a
sustained short circuit without damage.
The outputs are not intended to accept
appreciable reverse current.
Storage Temperature -55 to +125 ˚C.
Lead Temperature See soldering specifi cations
Absolute maximums are stress ratings. Exposure of devices to greater than any of
any of these conditions may adversely affect long-term reliability. Proper operation
under conditions other than those listed in the Performance/Functional Specifi cations
Table is not implied or recommended.
Specifi cation Notes:
(1) Specifi cations are typical at +25 °C, Vin=nominal (+12V.), Vout=nominal (+5V), full load, external caps and
natural convection unless otherwise indicated. Extended tests at full power must supply substantial forced
airfl ow.
All models are tested and specifi ed with external 10F ceramic output capacitors and a 22 F external
input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test
equipment and may not be required to achieve specifi ed performance in your applications. However, Murata
Power Solutions recommends installation of these capacitors. All models are stable and regulate within
spec under no-load conditions.
(2) Input Back Ripple Current is tested and specifi ed over a 5 Hz to 20 MHz bandwidth. Input fi ltering is Cin=2 x
100 F ceramic, Cbus=1000 F electrolytic, Lbus=1 H.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher
temperatures and/or lower airfl ow, the DC/DC converter will tolerate brief full current outputs if the total
RMS current over time does not exceed the Derating curve.
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fi xed
conditions, Tpcboard=+25 ˚C, full output load, natural air convection.
(4b) Mean Time Before Failure is calculated using the MIL-HDBK-217N2 method, ground benign, +25ºC., full
output load, natural convection.
OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
MDC_OKL-T/3-W12 Series.A21 Page 3 of 18
www.murata-ps.com/support