Sola/Hevi-Duty
Sola Hardwired CVS Ñ
30 VA to 7.5 kVA
Applications
c
Marine Navigation Equipment
c
Analytical Laboratory Equipment
c
Photographic Enlargers
c
Photo Processing Equipment
c
Closed Circuit TV Transmission
c
Sound/Recording Systems
Features and Benefits
c
Applications Requiring Precise Voltage Regulation Can Expect to
Receive ±1% Output Regulation for Input Variation of +10 to Ð20%
c
Protects Premise Wiring Since Non-Linear Loads are Reflected Back to
the Utility as Near Sinusoidal
c
Safety Agency Approved: All CVSs are UL Listed and CSA Certified
c
Dual Function, Can Act as a Stepup or Stepdown Transformer in
Addition to Providing Regulation
c
Sinewave Output Even With a Distorted Source; Input Harmonics Are
Eliminated
c
Half Load Input Voltage Range of +15 to Ð50% Input for +5, Ð10%
Regulation
Precise Voltage Regulation for Industrial Applications
The Sola CVS Series voltage regulators provide highly regulated sinewave
voltage output with less than 3% harmonic distortion. CVS transformers are
commonly used in industrial applications where voltage regulation is of
primary importance. This unit is only available in the hardwired form and is
recommended for installation at the distribution panel.
Specifications
Input
VA Ratings: 30 to 7,500 VA. Input Voltage Range: +10/Ð20% of nominal.
Output
Voltage Regulation: ±1% for an input line variation of +10/Ð20%. No loss of output for line loss of 3 mSec. Overload:
Output collapses with overload; limits output current to a maximum of 2x rated current. Output Harmonic Distortion: 3%
total RMS content at full load. Harmonic Rejection: Rejects severe waveform harmonics. Noise Isolation: 40 dB common
and normal mode. Surge Suppression: UP to 6,000 Volt surges are suppressed to safe levels per ANSI/IEEE C62.41-1980
Class A and B waveforms. Efficiency: Up to 92% at full load.
Environmental
Operating Temperature: Ð20¡C to +50¡C. Audible Noise: 34 dB to 65 dB.
Approvals
Listed to UL 1012; Certified to CSA C22.2, No. 66.
Warranty
10 year limited warranty.
60 Hz
Output
Stock Mfr.Õs Capacity
No. Type (VA)
Voltage
Output Input
Dimensions
H ´W ´D
(Inches)
Shipping
Weight
(Lbs.)
EACH
1-2
556-5091 63-23-112-4 120 120 120, 208, 240, 480 8.62 ´3.31 ´5.18 15 279.71
556-5092 63-23-125-4 250 120 120, 208, 240, 480 9.88 ´4.50 ´7.44 27 369.00
556-5093 63-23-150-8 500 120, 208, 240 120, 208, 240, 480 12.69 ´7.78 ´6.44 37 550.61
556-5094 63-23-175-8 750 120, 208, 240 120, 208, 240, 480 13.69 ´7.78 ´6.44 52 701.98
556-5095 63-23-210-8 1000 120, 208, 240 120, 208, 240, 480 16.75 ´7.78 ´6.44 62 812.10
556-5096 63-23-215-8 1500 120, 208, 240 120, 208, 240, 480 16.44 ´10.56 ´9.03 95 1095.19
556-5097 63-23-220-8 2000 120, 208, 240 120, 208, 240, 480 17.31 ´10.56 ´9.03 109 1916.90
556-5103 63-23-230-8 3000 120, 208, 240 120, 208, 240, 480 18.69 ´10.56 ´9.03 142 2063.66
556Q5105 63-23-250-8 5000 120, 208, 240 120, 208, 240, 480 28.19 ´10.59 ´8.97 222 3323.00
556Q5106 63-28-275-8 7500 120, 208, 240 208, 240, 480 26.56 ´24.82 ´8.97 362 3562.18
556Q5107 63-28-310-8 10000 120, 208, 240 208, 240, 480 28.19 ´24.82 ´8.97 446 5832.05
556Q5108 63-28-315-8 15000 120, 208, 240 208, 240, 480 28.19 ´37.23 ´9.34 710 7941.70
Also Available; 60 V input models and 50 Hz models.
556-3150 23-13-030-2 30 120 120 6.03 ´3.31 ´5.18 7 211.05
556-3200 23-13-060-2 60 120 120 6.88 ´3.31 ´5.18 9 243.60
556-3300 23-22-112-2 120 120 120, 240 7.94 ´3.31 ´5.18 13 331.80
556-3350 23-23-125-8 250 120 120, 240, 480 9.88 ´4.50 ´7.44 29 379.63
556-3400 23-23-150-8 500 120, 240 120, 208, 240, 480 12.69 ´7.78 ´6.44 42 565.16
556-3850 23-23-210-8 1000 120, 240 120, 208, 240, 480 16.75 ´7.78 ´6.78 65 787.92
556Q3950 23-23-220-8 2000 120, 240 120, 208, 240, 480 17.31 ´10.56 ´9.34 111 1341.44
556Q4000 23-23-230-8 3000 120, 240 120, 208, 240, 480 18.69 ´10.56 ´9.34 142 1854.03
556Q9965 23-23-250-8 5000 120, 240 120, 208, 240, 480 28.19 ´10.59 ´9.28 222 3133.93
556Q2130 23-28-275-6 7500 120, 240 240, 480 29.06 ´24.82 ´8.97 365 4112.27
SOLA Power Conditioners and Constant Voltage Supplies
734
b
ALLIED Letter ÒQÓ In Stock Number Indicates Direct Factory Shipment To You
Output
Stock Mfr.Õs Capacity
No. Type (VA)
Voltage
Output Input
Dimensions
H ´W ´D
(Inches)
Shipping
Weight
(Lbs.)
EACH
1-2
Sola Hardwired MCR Ñ
120 VA to 15 kVA
Applications
c
Programmable Logic Controllers (PLCs)
c
Machine Tools
c
Computer Loads
c
Robotics
c
Industrial Panels
c
Electronic Equipment
Features and Benefits
c
Protects Facility Wiring From Odd-Order Harmonics (Excessive
Currents in Building Wiring) Caused by Switchmode Power Supplies
(Computer Loads); Non-Linear Load Currents Are Reflected Back to the
Utility as Near Sinewave
c
Regulates Voltage, Provides Surge Suppression, Isolation and
Harmonic Filtering
c
Acts as a Stepup or Stepdown Transformer
c
Rugged Design Handles Hostile Industrial Environments
c
Smooth ±3% Voltage Regulation for Input Variation of +10 to Ð20%
c
10-Year Warranty; 25-Year Typical Life
Permanent Protection Against Surges, Sags, Spikes, Brownouts,
Harmonics and EMI/RFI Noise
The Sola Hardwired MCR Series protects equipment from nearly all power
problems short of a total power failure. Hardwired MCR models are designed
to be permanently wired into the userÕs system and are available in sizes from
120 VA to 15 kVA.
Specifications
Input
VA Ratings: 120 to 15,000 VA. Input Voltage Range: +10/Ð20% of nominal.
Output
Voltage Regulation: ±3% for an input line variation of +10/Ð20% (50 Hz units ±5%). No loss of output for complete line
loss of 3 mSec. Overload: Output collapses with overload; limits output current to a maximum of 2x rated current. Output
Harmonic Distortion: 3% total RMS content at full load. Harmonic Rejection: Rejects severe waveform harmonics. Noise
Isolation: 120 dB common mode; 60 dB normal mode. Surge Suppression: UP to 6,000 Volt surges are suppressed to
safe levels per ANSI/IEEE C62.41-1980 Class A and B waveforms. Efficiency: Up to 92% at full load.
Environmental
Operating Temperature: Ð20¡C to +50¡C. Audible Noise: 35 dB to 65 dB.
Approvals
60 Hz: Listed to UL 1012; Certified to CSA C22.2, No. 66. 50 Hz: Models comply to VDE 0805, 0806, and 0550.
Warranty
10 year limited warranty.
60 Hz
Sola Portable MPC Ñ
70 VA to 1 kVA
Reliable Power Protection for Critical Medical Applications
The Sola MPC Series medical power conditioner is your prescription for effective protection from surges, sags, spikes, brownouts and noise. Imaging systems,
monitors, diagnostic and patient-care equipment are prone to loss of data integrity, poor performance and increased downtime caused by electrical disturbances.
Safely protect your vital equipment from power-related problems and increase performance with regulated, noise-free power from the MPC.
Specifications
Input
VA Ratings: 250, 500, 1,000 VA. Input Voltage Range: +10/Ð20% of nominal.
Output
Voltage Regulation: ±3% for an input line variation of +10/Ð20%. No loss of output for complete line loss of 3 mSec. Overload: Output collapses with overload;
limits output current to a maximum of 2x rated current. Output Harmonic Distortion: 3% total RMS content at full load. Harmonic Rejection: Rejects severe
waveform harmonics. Noise Isolation: 120 dB common mode; 60 dB normal mode. Surge Suppression: UP to 6,000 Volt surges are suppressed to safe levels per
ANSI/IEEE C62.41-1980 Class A and B waveforms. Efficiency: Up to 87% at full load.
Environmental
Operating Temperature: Ð20¡C to +40¡C. Audible Noise: 43 dB.
Approvals
Listed to UL 1012 and UL 544. Less than 50 µA leakage current for indirect patient care products per UL 544. Designed to meet UL 478. Certified to CSA C22.2,
No. 66.
Warranty
10 year limited warranty.
Input/
Stock Mfr.Õs VA Output
No. Type Rating Voltage
NEMA
Plug Receptacle
Dimensions Shipping
H ´W ´D Weight
(Inches) (Lbs.)
EACH
1-2
556-2132 63-13-150-7 500 120 5-15 P (4) 5-15 R 8.50 ´8.50 ´16.0 32 598.10
556-2133 63-13-210-7 1000 120 5-15 P (4) 5-15 R 8.50 ´8.50 ´16.0 69 966.65
Applications
c
Monitors
c
Diagnostic Equipment
c
Imaging Systems
c
Any Data Sensitive Patient Care Equipment
c
Medical Carts
Features and Benefits
c
Exceptionally Low Leakage Current Exceeds the Requirement of UL 544
c
Safe to Use; Units are UL Listed to 1012 and 544, Also Certified to CSA
22.2 and No. 66
c
Orange Output Receptacles With Green Triangles Indicate the MPC has
Isolated Ground Outputs and Is Safe for Hospital Grade Use
c
Quiet, Portable and Easy-To-Use; Just Plug It In
12