VES90 Series AC-DC Power Supplies 90 Watts * Energy Efficiency Level VI * European CoC Tier 2 * High Power Density * Single Outputs from 12 V to 48 V * <0.15 W Standby Power * China Compulsory Certification (CCC) Qualified * 0 C to 60 C Operation B R A N D * Optional Output Connector * Low Cost Dimensions: VES90: 5.47 x 2.28 x 1.22" (139.0 x 58.0 x 31.0 mm) Models & Ratings Output Power Output Voltage 12.0 V 19.0 V 24.0 V 48.0 V 90 W Output Current 7.50 4.74 3.75 1.875 A A A A Total Regulation Efficiency(1) 5% 89% 89% 89% 89% Model Number(2) VES90PS12 VES90PS19 VES90PS24 VES90PS48 Notes 1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input. 2. For optional Barrel Jack Connector, 2.5 mm inner positive, 5.5 mm outer negative, 11 mm length add suffix `-B' e.g. VES90PS24-B. Mechanical Details 47.24 0.79 (1200 20) 5.47 (139.0) 2.28 (58.0) 1 3 2 4 Pin 1 2 3 4 Function Output + Output + Return Return Shell Connected to output return and input ground LED Indicator 1.22 (31.0) Rating Label Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Output connector: Power Mini DIN, mates with Kycon KPJX-4S or equivalent. 1 3. Weight: 0.82 lbs (370 g) approx. www.xppower.com IEC320-C14 VES90 Series AC-DC Power Supplies Input Characteristic Minimum Input Voltage 90 Input Frequency Input Current Inrush Current Power Factor Earth Leakage Current No Load Input Power Input Protection 47 Typical Notes & Conditions Maximum Units 264 VAC 63 130 Hz A A 3.5 0.15 mA W Max. 48 2 Units VDC % 3 50 Full load and 115 VAC/230 VAC 0.5 5 s ms ms % % 4 % Maximum deviation, recovering to less than 1% within 500 s for 25% step load change 2/1 % pk-pk 200 180 % % % 1.5/0.6 Measured at 115/230 VAC 230 VAC, cold start at 25 C EN61000-3-2 Class A 264 VAC, 60 Hz T3.15A/250 VAC internal fuse in line Output Characteristic Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Total Regulation Min. 12 Typ. 8/16 Transient Response Ripple and Noise Overshoot Overload Protection Overvoltage Protection Short Circuit Protection Temperature Coefficient 5 120 Trip and restart (hiccup), auto resetting 0.04 Notes & Conditions See Models and Ratings table At 50% load No minimum load required 2% for 12/19/24 V, 1% for 48 V, 20 MHz bandwidth, measured with 20 MHz Bandwidth and 10 F electrolytic in parallel with 0.1 F ceramic capacitor. At turn on / turn off Recycle mains to reset %/C Environmental Characteristic Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Shock Vibration Minimum 0 Natural convection 10 -40 Typical Maximum +60 Units C Notes & Conditions Derate from 100% load at 40 C to 50% load at 60 C 90 %RH Non-condensing +70 C 5000 m IEC68-2-27, 30 g, 30 ms half sine, 3 times in each of 6 axes IEC68-2-6, 10-500 Hz, 0.25 g 10 mins/sweep, 60 mins for each of 3 axes 100% Output Power (%) Derating Curve 80% 60% 40% 20% 0 20 40 Ambient Temperature (C) www.xppower.com 60 2 VES90 Series AC-DC Power Supplies General Characteristic Minimum Typical Efficiency Maximum Units % 89 See Models and Ratings table and curves. VAC 3000 Isolation: Input to Output Input to Ground Output to Ground 1500 VAC VDC Output return is connected to input ground At full load Switching Frequency 55 kHz Power Density 5.9 W/in3 Mean Time Between Failure Weight Notes & Conditions >100 kHrs 0.82 (370) lb (g) MIL-HDBK-217F at 25 C GB Efficiency Curves VES90PS12 100% Efficiency 90% 80% 115Vac 230Vac 70% 60% 50% 10 20 30 40 50 60 70 80 90 100 Load (%) VES90PS24 100% Efficiency 90% 80% 115Vac 230Vac 70% 60% 50% 10 20 30 40 50 60 70 80 90 100 Load (%) EMC: Emissions Phenomenon Emissions Harmonic Current Voltage Flicker Standard EN55032 EN61000-3-2 EN61000-3-3 Test Level Level B Class A www.xppower.com Notes & Conditions Conducted & Radiated 3 VES90 Series AC-DC Power Supplies EMC: Immunity Phenomenon Standard ESD Radiated EFT/Burst Surge Conducted Magnetic Fields EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 Dips and Interruptions EN61000-4-11 Test Level Criteria 15 kV Air, 8 kV contact 3 V/m 2 Installation Class 3 3V 3 A/m Dip: 30% 500 ms Dip: 60% 200 ms Dip: 100% 5000 ms Int: 100% 10 ms A A A A A A A/B A/B B A Notes & Conditions High Line/Low Line High Line/Low Line Safety Approvals Safety Agency Safety Standard UL Notes & Conditions UL60950-1 TUV EN60950-1 CB IEC60950-1 CCC China Compulsory Certification, GB4943 AU/NZ AU/NZ 60950.1 ITE. 19, 24 & 47 V models meets LPS Mechanical Details 47.24 0.79 (1200 20) 5.47 (139.0) 2.28 (58.0) 1 3 2 4 LED Indicator 1.22 (31.0) IEC320-C14 Rating Label Pin 1 2 3 4 Function Output + Output + Return Return Shell Connected to output return and input ground Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Output connector: Power Mini DIN, mates with Kycon KPJX-4S or equivalent. 3. Weight: 0.82 lbs (370 g) approx. www.xppower.com 18 Sept 18