Sensorless Vector Variable Frequency Inverters
- 0.4kW to 280kW
High performance, Torque Vector Control
Up to 250% torque at 1Hz
Low torque ripple at low speed
Fast torque response - 200mS, 0 - 100% load
Load speed regulation < 1% open loop
User friendly self tuning to motor
Ultra compact IP20 enclose (22kW)
Dual LED/LCD plain English display
User programmable I/O
Low motor noise profile
Auto energy saving function
Renowned IMO 5 year warranty
JAGUAR VX Torque Vector System
Specifications
NOTES * FIGURES FOR INPUT ARE QUOTED WHEN USING A DC REACTOR FROM VX30K AND VX30KP UP, NO REACTOR < 30KW
** AT 100% FULL LOAD CURRENT AND USING DC REACTOR
JAGUAR VX ORDER CODES VX40 VX75 VX150 VX220 VX400 VX550 VX750 VX1100 VX1500 VX1850 VX2200
JAGUAR VXP ORDER CODES - - - - - - VX750P VX1100P VX1500P VX1850P VX2200P
MOTOR RATING (kW) 0.4 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22
RATED O/P CURRENT (A) 1.5 2.5 3.7 5.5 9 13 18 24 30 39 45
100% RATED I/P CURRENT RMS 1.7 2.9 5.5 7.7 12.6 18.2 24.4 36.3 48.5 59 72
(AT 400V)*
HEAT LOSS (W) 45 50 65 85 110 140 200 315 340 450 510
(AT 2 KHz CARRIER FREQUENCY)
INPUT VOLTAGE/FREQUENCY 3 PHASE 380 TO 415V (+10%,-15%) 50/60 Hz (+5%,-5%)
WEIGHT (Kg) 2.4 3.2 3.2 3.2 3.2 6.5 5.3/6.5 10.6/6.5 10.6/11.5 10.6/11.5 10.6/12
INPUT POWER FACTOR** 0.96 0.95 0.94 0.93 0.94 0.95 0.95 0.95 0.94 0.95 0.96
OUTPUT VOLTAGE FREQUENCY 3 PHASE 0 - V INPUT 0.2 - 400 Hz (‘P’ MODELS 0.2 - 120 Hz)
JAGUAR VX ORDER CODES VX30K VX37K VX45K VX55K VX75K VX90K VX110K VX132K VX160K VX200K VX220K
JAGUAR VXP ORDER CODES VX30KP VX37KP VX45KP VX55KP VX75KP VX90KP VX110KP VX132KP VX160KP VX200KP VX220KP VX280KP
MOTOR RATING (kW) 30 37 45 55 75 90 110 132 160 200 220 280
RATED O/P CURRENT (A) 60 75 91 112 150 176 210 253 304 377 415 520
100% RATED I/P CURRENT RMS 58 71 85 104 141 168 203 243 293 363 400 508
(AT 400V)*
HEAT LOSS (W) 1200 1400 1600 1900 2300 2700 3000 3400 4000 4600 5000 6000
(AT 2 KHz CARRIER FREQUENCY)
INPUT VOLTAGE/FREQUENCY 3 PHASE 380 TO 415V (+10%,-15%) 50/60 Hz (+5%,-5%)
WEIGHT (Kg) 36 36/37 37/44 45/54 54/61 61/88 88 88/120 120/125 125/177 177 177
INPUT POWER FACTOR** 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95
OUTPUT VOLTAGE FREQUENCY 3 PHASE 0 - V INPUT 0.2 - 400 Hz (‘P’ MODELS 0.2 - 120 Hz)
5
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Basic circuit configuration and terminals
Jaguar VX
P1
DC Bus reactor
(Optional 22kW)
3-phase
power
supply
50Hz or
60Hz
*
GND
(PE) 2
1
M
Link P1 to (*)
if DC reactor
not required
Braking resistor (option)
for all inverters.
Braking unit (option).
Applicable to VX1100, VX1500P, VX30K
and inverters larger than these.
On-board braking IGBT and resistor applicable
only to VX40 to VX750 and VX750P to VX1100P.
Disconnect the internal resistor (R) before
connecting an external resistor.
*
*
U
V
W
L1
L2
L3
(13)
(12)
(11) Z
0V
Analog voltage
frequency ref.
input
(Pot. 1k, 1W)
(C1) 250
Power
charge
LED
‘CRG’
(FMA)
4-20mA
analog input
+10V DC
0 to 10V DC
(FWD)
BU
RTS
(REV)
(THR)BU RTS
12
(CM)
(X1)
(HLD)
4.7k
(X2)
(X3)
(X4)
(X5)
(BX)
(RST)
(P24) or (CMS)
Programmable
analog
output
Connect via
RF filter (if fitted)
(Y5E)
(CMC)
(Y4E)
(Y3E)
(Y2E)
(Y1E)
(30A)
(30B)
(30C) Trip
relay
output
Programmable
outputs
Control
inputs
DC voltage
detection
Gate
drive
Keys LED, LCD
displays
CPU
A/D
Input
signal
PWM
generator
Auto-
voltage
regulator
Accel /
Decel
regulator
A/D
Function
generator
Frequency
command
switch
NOTES
CPU
Keypad Panel
GND
(PE)
(P24) or (CMS)
Digital
output
(FMP) Pulse output
Input
contactor
+ve
GND
(PE)
0V
(CM) 0V
For inverters rated 22kW the inrush contactor is replaced by an SCR.
Voltage detection circuit applicable for inverters 30kW only.
Standard for inverters 30kW, optional for smaller models.
Two terminals (CM) standard for inverters 22kW, one for 30kW.
If motor thermistors are required, please consult IMO.
Internal +24V DC supply terminal designated P24 (22kW) or CMS (30kW).
(AX2)
(AX1) Run
relay
output
SMPS
+24V DC
4.7k
4.7k
4.7k
4.7k
4.7k
4.7k
4.7k
4.7k
4.7k
4.7k
0V +24V DC
(V1)
Note (2)
Note (3)
Output
signal
Note (3)
Torque
vector
calculator
Protective
logic
Note (4)
Note (1)
0V Common Terminals (11) and
(CM) are optically isolated.
Relay status shown as at inverter
‘power ON’ or ‘healthy’.
(1)
(2)
(3)
(4)
(5)
(6)
24V
0V
Earth busbar
at MCC
Terminal Markings for DC
bus reactor and Braking
Resistor or Braking Unit
The marking of these
terminals varies between
different sizes of Jaguar VX
inverter. Please refer to
pages 19, 20 and 21 for
specific detail.
*
P(+)
RTS = Volt-free NC contact
for thermal protection.
R
N(-)
P(+) DB
Voltage
detection
Current
detection
Note (6)
Note (6)
WARNING! INVERTER MUST
BE EARTHED
Terminal Markings for DC
bus reactor and Braking
Resistor for Braking Unit
The marking of these
terminals varies between
different sizes of Jaguar VX
inverter. Please refer to
manual for specific details.
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Control circuit connections
Jaguar VX
Purpose
Analog
frequency
setting
Programmable
inputs
Meter
outputs
Programmable
outputs
Relay
outputs
Terminal
11
12
13
C1
V1*
CM†
FWD
REV
HLD
BX
THR
RST
X1
X2
X3
X4
X5
P24
P24
FMA
FMP
CMC
Y1E
Y2E
Y3E
Y4E
Y5E
30A
30B
30C
AX1*
AX2*
Terminal Name
Speed reference 0V common
Potentiometer input
Potentiometer supply
Current loop input
Auxiliary freq. reference
0V common
Forward and STOP command
Reverse and STOP command
FWD/REV command hold
Coast-to-stop command
External Trip/Alarm input
Trip/Alarm RESET
Programmable input 1
Programmable input 2
Programmable input 3
Programmable input 4
Programmable input 5
+24V DC power supply
Analog meter
Pulse frequency meter
Open-collector common
Programmable output 1
Programmable output 2
Programmable output 3
Programmable output 4
Programmable output 5
Normally open
Normally closed
Common
Run relay
Description
For use with terminals 12, 13 and C1 (and V1, 30kW only)
Maximum speed demand is at +10V with a 0V to +10V DC
input. Input impedance 20k(22kW), 22k(30kW).
Regulated +10V DC power supply for 1kmin. speed control
potentiometer. Input 10mA max.
Maximum speed demand is at 20mA with a 4-20mA DC
input, impedance 250. Inverter output frequency is
proportional to current input signal, zero speed = 4mA.
Bipolar 0V to ±10V input.
0V common terminals for general use.
FWD-P24 closed: Motor runs forward
open: Motor decelerates to rest
REV-P24 closed: Motor runs in reverse
open: Motor decelerates to rest
HLD-P24 closed: Latches momentary FWD or REV inputs
open: FWD/REV non-latching
BX-P24 closed: Inhibit inverter output instantaneously
open: Normal
THR-P24 closed: Normal
open: Trip (OH2) inverter output instantaneously
If RST-P24 closed for 100ms, inverter internal fault trips are
reset, and also alarm 30A/B/C (see below).
Preset speeds or motorised potentiometer
Preset speeds or mains-to-inverter changeover
Preset acc/dec command. LOC/REM changeover.
DC injection brake command.
Preset acc/dec times. 2nd motor V/F ratio. Data protection
enable/disable.
24V current source for programmable I/O terminals and for
FWD, REV, HLD, BX, THR, RST and X1 to X5.
Output frequency, current, torque or load factor can be
selected. 0V to +10V DC at 2mA max.
(Min. impedance 5kΩ)
Pulse output proportional to inverter output frequency. Pulse
frequency 6 to 100 x O/P Hz at +10V DC (adjustable).
0V
Relay changes state when an internal protection function is
active and when the inverter trips.
Contact: 250V AC, capacity 0.5A, cosφ0.3
Relay closes when inverter is running
Contact: 250V AC, capacity 0.5A, cosφ0.3
If FWD and
REV are both
closed or both
open, inverter
output STOPS.
Up to 16 different outputs can be programmed
from the operating Functions representative of
dynamic operating conditions.
Factory defaults:
Y1E Inverter running
Y2E FAR Y4E Overload early warning
Y3E FDT Y5E Undervoltage
Output:
27V DC,
50mA per
O/P channel,
total 50mA
maximum.
Caution
Read Technical
Manual before
use.
* Standard for 30kW only, optional for 22kW. † Two CM terminals for 22kW, one for 30kW.
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Parameter list/function code table
Jaguar VX
Group No. Name LCD Display Setting range Unit Resol. Def.
Basic
Functions 00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
to
26
27
28
29
30
Frequency command
Operating mode
Max. O/P frequency
Base freq., motor 1
Max. O/P V, motor 1
Accel. time, motor 1
Decel. time, motor 1
Torque boost, motor 1
Electronic thermal
O/L, type
Electronic O/L, level
Restart after
momentary power
supply failure
O/P freq. HI limit
O/P freq. LO limit
Min. O/P freq. (bias)
Freq. I/P ref. gain
Driving torque limit
Braking torque limit
DC inj. brk. Start frequ.
DC inj. brk. Brkg. level
DC inj. brk. Brkg. time
Pre-set multistep
frequencies 1 to 7
Intl. electronic thermal
O/L for intl. brkg. R
Slip compensation
Torque vector control
Number of motor poles
00 FREQ COMND
01 OPR METHOD
02 MAX Hz
03 BASE Hz -1
04 RATED V -1
05 ACC TIME 1
06 DEC TIME 1
07 TRQ BOOST 1
08 ELECTRN OL
09 OL LEVEL
10 RESTART
11 H LIMITER
12 L LIMITER
13 FREQ BIAS
14 FREQ GAIN
15 DRV TORQUE
16 BRK TORQUE
17 DC BRK Hz
18 DC BRK LVL
19 DC BRK t
20 MULTI Hz -1
to
26 MULTI Hz -7
27 DBR OL
28 SLIP COMP
29 TRQ VECTOR
30 MTR POLES
0 = KEYPAD, or keys
1 = TERMINAL, 0 to +10V
2 = TERMINAL, 4 to 20mA
0 = KEYPAD, RUN/STOP keys
1 = TERMINAL, (FWD) & (REV)
VX, 50-400Hz VX…P, 50-120Hz
VX, 50-400Hz VX…P, 50-120Hz
0 = Output dependent on supply V*
320 to 480 = output V
0.01 to 3600
0.00 = ramp inhibit, or 0.01 to 3600
0.0 = auto; 0.1 to 20.0 fixed boost
0 = Inactive
1 = Active for standard motor
2 = Active for inverter-rated motor
20% to 105% of inverter rating
0 = Inactive 1
1 = Inactive 2
2 = Active, smooth recovery
3 = Active, restart at set Hz
4 = Active, restart at start Hz
VX, 0-400Hz VX…P, 0-120Hz
VX, 0-400Hz VX…P, 0-120Hz
VX, 0-400Hz VX…P, 0-120Hz
0.0 to 200.0%
20 to 180, 999% (999 = no limit)
0, 20 to 180, 999% (999 = no limit)
0.0 to 60.0Hz
0.0 to 100%
0.0 (brake inactive), or 0.1 to 30.0s
VX 0.00, 0.20 to 400.0Hz
VX…P 0.00, 0.20 to 120.0Hz
(0.00 = preset disabled)
0 = Inactive
1 = Active for intl. R, invrs. 7.5kW
2 = Inactive
-9.9Hz to +5.0Hz
0 = Inactive 1 = Active
2 to 14 (even nos. only)
Hz
Hz
V
s
s
A
Hz
Hz
Hz
%
%
%
Hz
%
s
Hz
Hz
1
1
1
0.01
0.01
0.1
0.01
1
1
1
0.1
1
1
0.1
0.1
0.1
0.01
0.1
2
0
0
50
50
400
6.00
6.00
0.0
[0.1]
1
3
70
0
0
100.0
150
[120]
100
[100]
0.0
0.0
0.0
0.00
1 [0]
0.0
0
4
Functions marked by heavy outlines can be set whilst the inverter is running. DEF = factory-set defaults. Resol = resolution.
Default values are for all inverters. Where VX…P defaults differ, they are shown in square brackets […].
* LCD display shows 0V Approx. rated current for inverter-rated motors
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Parameter list/function code table (continued)
Jaguar VX
Group No. Name LCD Display Setting range Unit Resol. Def.
Prog. I/P
terminals
Acc./Dec.
times
2nd
motor
Digital
O/P
Analog
O/P
O/P term.
functions
Frequency
control
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
Function Block 32 to 41
Select the functions of
terminals X1 to X5
Accel time 2
Decel time 2
Accel time 3
Decel time 3
Accel time 4
Decel time 4
Base freq., motor 2
Max. O/P V, motor 2
Torque boost, motor 2
Function Block 43 to 51
FMP terminal, pulse
rate multiplier
Voltage O/P adjustmt.
FMA terminal, voltage
adjustment
FMA terminal function
Select the functions of
terminals Y1E to Y5E
FAR function (‘At
Speed’ window)
FDT function (level)
FDT function (hyster.)
O/L alarm (level)
Function Block 53 to 59
Skip frequency 1
Skip frequency 2
Skip frequency 3
Skip hysteresis
Starting frequency
Holding time
Frequency I/P
reference filter
31 32—41
32 X1-X5 FUNC
3X ACC TIME X
39 BASE Hz -2
40 RATED V -2
41 TRQ BOOST 2
42 43—51
43 FMP PULSES
44 FMP V-ADJ
45 FMA V-ADJ
46 FMA FUNC
47 Y1-Y5 FUNC
48 FAR HYSTR
49 FDT LEVEL
50 FDT HYSTR
51 OL WARNING
52 53—59
53 JUMP Hz 1
54 JUMP Hz 2
55 JUMP Hz 3
56 JUMP HYSTR
57 START Hz
58 HOLDING t
59 FILTER
0 = Functions 32 to 41 hidden
1 = Functions 32 to 41 displayed
0000 to 2222
0.00 = Ramp inhibited, coasting
0.01 to 3600s
VX, 50-400Hz VX…P, 50-120Hz
0 = Output dependent on supply V*
320 to 480 = output V
0.1 to 20.0 fixed boost
0 = Functions 43 to 51 hidden
1 = Functions 43 to 51 displayed
x6 to x100
50% to 120%
65% to 200%
0 = O/P freq. 1 = O/P current
2 = O/P torque 3 = %FLT
00000 to FFFFF
0.0 to 10.0Hz
VX, 0-400Hz VX…P, 0-120Hz
0.0 to 30.0Hz
Approx. 20 to 105% inverter rated
current
0 = Functions 53 to 59 hidden
1 = Functions 53 to 59 displayed
VX, 0-400Hz VX…P, 0-120Hz
VX, 0-400Hz VX…P, 0-120Hz
VX, 0-400Hz VX…P, 0-120Hz
0 to 30Hz
0.2Hz to 60.0Hz
0.0 to 10.0s
0.01 to 5.00s
s
Hz
V
%
%
Hz
Hz
Hz
A
Hz
Hz
Hz
Hz
Hz
s
s
0.01
1
1
0.1
1
1
1
0.1
1
0.1
0.01
1
1
1
1
0.1
0.1
0.01
0
0000
10.00
10.00
15.00
15.00
3.00
3.00
50
400
2.0
0
x24
100%
100%
0
01234
2.5
50
1.0
0
0
0
0
3
0.5
0.0
0.05
31
42
52
Functions marked by heavy outlines can be set whilst the inverter is running. DEF = factory-set defaults. Resol = resolution.
Default values are for all inverters. Where VX…P defaults differ, they are shown in square brackets […].
* LCD display shows 0V Approx. rated current for inverter-rated motors
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Parameter list/function code table (continued)
Jaguar VX
Group No. Name LCD Display Setting range Unit Resol. Def.
LED &
LCD
displays
Pattern
operations
Special
Functions
1
Special
Functions
2
Motor
characteristics
Special
Functions
3
60
61
62
63
64
65
66
to
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
Function Block 61 to 79
LEDs, function for
normal display
LEDs display at STOP
Coefficient for machine
speed and line speed
LCD display function
Pattern operation,
mode select
Pattern stages 1 to 7
ACC/DEC mode
Series brake motor
driving
Energy saving
REV phase sequ. lock
Data initialising (data
reset)
Language of displays
LCD display
brightness
Function Block 81 to 94
PWM carrier frequency
(motor sound)
Auto-restart, start delay
Auto-restart, freq. fall
rate
Auto-reset, number of
restarts
Auto-reset, interval
Motor 1, frame size
Motor 1, rated current
Motor 1, no-load current
Motor 2, rated current
Motor 1, tuning
Motor 1, %R1 value
Motor 1, %X value
Manufacturer s use
only
Data security
60 61—79
61 LED MNTR 1
62 LED MNTR 2
63 SPEED COEF
64 LCD MNTR
65 PATTERN
6X STAGE X
73 ACC PTN
74 SERIES BRK
75 ENERGY SAV
76 REV LOCK
77 DATA INIT
78 LANGUAGE
79 BRIGHTNESS
80 81—94
81 MTR SOUND
82 RESTART 1
83 FALL RATE
84 AUTO RESET
85 RESET INT
86 MOTOR CAP
87 MOTOR 1-Ir
88 MOTOR 1-Io
89 MOTOR 2-Ir
90 TUNING
91 %R1 SET
92 %X SET
93 DD FUNC 1
94 DD FUNC 2
95 DATA PRTC
0 = Functions 61 to 79 hidden
1 = Functions 61 to 79 displayed
0 to 8
0 = Set point (flashing)
1 = Actual output value only
0.01 to 200.00 x Hz output
0 to 3: Drive status, standard screen
or bar graphs
0 to 3: Inactive or cyclic
Operation time 0.00 to 6000s
FWD/REV codes F1 to F4
ACC/DEC codes R1 to R4
0 to 2: linear, S-curve, non-linear
Not available
0 = Inactive 1 = Active
0 = Inactive 1 = Active
0 = Inactive 1 = Active
0 to 3
0 (bright) to 10 (dark)
0 = Functions 81 to 94 hidden
1 = Functions 81 to 94 displayed
0 (low) to 10 (high) carrier
frequency
0.0 to 5.0s
0.00 to 100.00
0 to 7
2 to 20s
0 = 1 higher 1 = nominal
2 = 1 lower 3 = 2 lower
0.00 to 2000A
0.00 to 2000A
0.00 to 2000A
0 = Inactive 1 = Active
0.00 to 50.00%
0.00 to 50.00%
0 = Unlocked 1 = Data secure
s
s
Hz/s
s
A
A
A
%
%
0.01
0.01
0.1
1
0.1
0.1
0.1
0.01
0.01
0
0
0
0.01
0
0
0.00
F1
0
0 [1]
0
0
1
5
0
10
0.1
10
0
5
1
0
0
80
0 = GERMAN, 1 = ENGLISH
2 = SPANISH, 3 = ITALIAN
60
Dimensions (mm) 0.4 to 280kW
Jaguar VX
Hz
A
V
r/min
m/min
%
PRG
RESET STOP
RUN
FUNC
DATA
KEYPAD OPERATION
Keypad panel
mounting dimensions.
Common to all modules.
68
78
125
115
STOP
Hz
A
V
r/min
m/min
%
PRG
RESET STOP
RUN
FUNC
DATA
KEYPAD OPERATION
96
110
246
260
687
130
6
37
7
7
Jaguar VX40
Hz
A
V
r/min
m/min
%
PRG
RESET STOP
RUN
FUNC
DATA
KEYPAD OPERATION
136
150
246
260
6102
145
6
52
7
Jaguar VX75 to VX400
7
Hz
A
V
r/min
m/min
%
PRG
RESET STOP
RUN
FUNC
DATA
KEYPAD OPERATION
196
220
238
260
10 162
195
10
97
12
10
Jaguar VX550, VX750, and VX750P, VX1100P
Hz
A
V
r/min
m/min
%
PRG
RESET STOP
RUN
FUNC
DATA
KEYPAD OPERATION
226
250
378
400
10 162
195
10
96
12
10
Jaguar VX1100 to VX2200 and VX1500P to VX2200P
W1
W
H2
H1
d
H
D1 D
Hz
A
V
r/min
m/min
%
PRG
RESET STOP
RUN
FUNC
DATA
KEYPAD OPERATION
2 holes
dmm diam.
CHARGE
Jaguar VX30K to VX220K, VX30KP to VX280KP
Side vents on
inverters from
VX30K to VX75K
and VX30KP to
VX90KP only
REMOTE MOUNTING
KEYPAD WITH OPTIONAL
2M CONNECTOR CABLE
*N.B. JAGUAR VX inverters are designed
for use within shielded steel enclosures
VX W W1 H H1 H2 D D1 d
30K-D
340 240 550 530 500 290 185 10
30KP-D 37KP-D
340 240 550 530 500 290 185 10
37K-D 45KP-D
375 275 550 530 500 290 185 10
45K-D 55KP-D
375 275 675 655 625 275 170 10
55K-D 75KP-D
530 430 675 645 610 290 185 15
75K-D 90KP-D
530 430 740 710 675 300 180 15
90K-D 110KP-D
530 430 740 710 675 330 205 15
110K-D 132KP-D
530 430 740 710 675 330 205 15
132K-D 160KP-D
530 430 1000 970 935 435 295 15
160K-D 200KP-D
530 430 1000 970 935 435 295 15
200K-D 220KP-D
680 580 1000 980 N/A 435 320 N/A
220K-D 280KP-D
680 580 1000 980 N/A 435 320 N/A
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Optional accessories
Jaguar VX
Accessory Function
Filters A specially designed range of easily fitted low profile ‘footprint’ filters up to
22kW and stand alone filters up to 280kW are available to provide maximum
RF reduction. See page 363 for details.
Function Copy Unit Saves and loads stored set-ups for up to 12 complete function sets. ‘Copy
Edit’, ‘verify’ and ‘write-protected’ modes available. Operates from an 85V to
265V AC supply. Target or donor drives do not need to be powered up to
transfer data.
Encoder Feedback Module Enables Jaguar VX inverters to be operated in closed-loop control mode.
Speed control range 180 to 3600 rpm. Speed variation ±0.2% at 3600 rpm.
Encoder output, 20 to 2000 pulses per revolution.
Relay Output Module Converts programmable outputs Y1E . . . Y5E to relay outputs.
Contact rating 0.3A at 250V AC, cosØ = 0.3.
PID Control Mode Unit Digitally adjustable P, I and D terms through the medium of a
supplementary function menu.
Reference input 0V to 10V DC
Feedback input 0V to 10V DC or 4-20mA DC.
Synchronisation Module Provides a multi-synch tasking capability via rotary encoders for
Master/Slave and ‘Follower’ applications.
Serial Communication Module RS422 or RS485, multi-drop up to 31 Jaguar VX inverters of all sizes. Opto-
isolated.
FieldBus Modules Dedicated FieldBus units which allow the connection of multiple
Jaguar VX inverters to a site standard FieldBus link.
FieldBus systems available:
Modbus Plus
Interbus S
Profibus DP
DeviceNet
Regenerative Brake Units Provides additional braking for high inertia loads for inverters 11kW to
280kW. (Units below 11kW have regenerative braking capability built in as
standard).
Pod Extension Cable Allows the Jaguar VX keypad to be removed and mounted separately.