CIRCUIT INTERRUPTION TECHNOLOGY INC. A-0709 SPECIFICATIONS Electrical Ratings Dielectric Strength Insulation Resistance Interrupt Capacity Contact Endurance Calibration Reset 3.0 - 16A @ 125/250VAC 4.0 - 16A @ 125 (UL/CUL) 1500Vrms min > 100M min 125VAC, 1000A; 250VAC, 1000A 125VAC X 150% of rated current - 500 cycles 25C - 105% of rated current - continuously carried 25C - 106% to 134% - may trip or not 25C - 135% of rated current - trip within 1 hour 150% of 4A - trip within 1 hour 25C - 200% of rated current - trip within 1 minute Manual reset E198027 ORDERING INFORMATION 1. Series A-0709 A-0709 2. Style P = 7/16" -28T bushing, Manual Reset 3. Current Rating: 3A - 16A 4. Reset Button Color: B = Black (White Printing) W = White (Black Printing) 5. Hardware: C = 1 Hex Nut, 1 Name Plate D = 1 Knurled Nut, 1 Name Plate E = 1 Hex Nut, 1 Knurled Nut, 1 Name Plate F = 2 Knurled Nuts, 1 Name Plate G = 2 Hex Nuts, 1 Name Plate P 3A B C Derating Factor Internal Resistance 3A - 5A 5.1A - 6A 6.1A - 7A 7.1A - 8A 8.1A - 9A 9.1A - 12A 12.1A - 14A 14.1A - 16A 0.120 0.100 0.075 0.035 0.020 0.015 0.010 0.008 TEMP 60C 55C 50C 45C 40C 35C 30C 25C 20C 15C 10C 3.0A-4.0A ------X 0.45 X 0.55 X 0.70 X 0.80 X 1.00 X 1.10 X 1.20 X 1.35 4A-16A X 0.50 X 0.60 X 0.70 X 0.75 X 0.80 X 0.86 X 0.92 X 1.00 X 1.06 X 1.09 X 1.20 DIMENSIONS PANEL CUT OUT CITFUSE Website: www.citfuse.com Tel: 763-535-2339 Fax: 763-535-2194