ATV320U22M2C Product datasheet Characteristics Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications variable speed drive ATV320 - 2.2kW 200...240V - 1 phase - compact Main Range of product Altivar Machine ATV320 Product or component type Variable speed drive Product specific application Complex machines Device short name ATV320 Format of the control block Compact Product destination Asynchronous motors Synchronous motors EMC filter Class C2 EMC filter integrated IP degree of protection IP20 conforming to EN/IEC 61800-5-1 Degree of protection UL type 1 with UL type 1 conformity kit Type of cooling Fan Network number of phases 1 phase [Us] rated supply voltage 200...240 V (- 15...10 %) Supply frequency 50...60 Hz (- 5...5 %) Motor power kW 2.2 kW for heavy duty Motor power hp 3 hp for heavy duty Line current 22.1 A at 200 V for heavy duty 18.5 A at 240 V for heavy duty Prospective line Isc 1 kA Apparent power 4.4 kVA at 240 V for heavy duty Continuous output current 11 A at 4 kHz for heavy duty Maximum transient current 16.5 A during 60 s for heavy duty Asynchronous motor control profile Voltage/frequency ratio, 2 points Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Synchronous motor control profile Vector control without sensor Speed drive output frequency 0.1...599 Hz Mar 28, 2019 1 Nominal switching frequency 4 kHz Switching frequency 4...16 kHz with current derating 2...16 kHz adjustable Safety function STO (safe torque off) SIL 3 SS1 (safe stop 1) SMS (safe maximum speed) SLS (safe limited speed) GDL (guard door locking) Communication port protocol CANopen Modbus Optional communication modules Communication module: CANopen daisy chain RJ45 Communication module: CANopen SUB-D 9 Communication module: CANopen open style terminal block Communication module: EtherCAT RJ45 Communication module: DeviceNet Communication module: Ethernet/IP Communication module: Profibus DP V1 Communication module: Profinet Communication module: Ethernet Powerlink Complementary Variant Standard version Output voltage <= power supply voltage Permissible temporary current boost 1.5 x In during 60 s for heavy duty Speed range With asynchronous motor in open-loop mode Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn Torque accuracy +/- 15 % Transient overtorque 170...200 % of nominal motor torque Braking torque <= 170 % with braking resistor during 60 s Regulation loop Adjustable PID regulator Motor slip compensation Automatic whatever the load Not available in voltage/frequency ratio (2 or 5 points) Adjustable 0...300 % Acceleration and deceleration ramps S U CUS Deceleration ramp automatic stop DC injection Deceleration ramp adaptation Linear Ramp switching Braking to standstill By DC injection Protection type Drive: thermal protection Drive: overcurrent between output phases and earth Drive: input phase breaks Drive: overheating protection Drive: short-circuit between motor phases Frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz Electrical connection Control, screw terminal: 0.5...1.5 mm AWG 20...AWG 16 Motor/braking resistor, screw terminal: 6 mm AWG 10 Power supply, screw terminal: 6 mm AWG 10 Connector type 1 RJ45 for Modbus/CANopen on control terminal Physical interface 2-wire RS 485 for Modbus Transmission frame RTU for Modbus Transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen Data format 8 bits, configurable odd, even or no parity for Modbus Type of polarization No impedance for Modbus Number of addresses For CANopen For Modbus Method of access Slave for CANopen 2 Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC (+/- 5 %) current <= 10 mA (overload and short-circuit protection) Local signalling 1 LED green for CANopen run 1 LED red for CANopen error 1 LED red for drive fault Width 105 mm Height 142 mm 188 mm with EMC plate Depth 158 mm Product weight 1.6 kg Analogue input number 3 Analogue input type Voltage (AI1): 0...10 V DC, impedance 30000 Ohm, resolution 10 bits Bipolar differential voltage (AI2): +/- 10 V DC, impedance 30000 Ohm, resolution 10 bits Current (AI3): 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance 250 Ohm, resolution 10 bits Discrete input number 7 Discrete input type Programmable (sink/source) (DI1...DI4): 24...30 V DC: level 1 PLC Programmable as pulse input 20 kpps (DI5): 24...30 V DC: level 1 PLC Switch-configurable PTC probe (DI6): 24...30 V DC Safe torque off (STO): 24...30 V DC, impedance 1500 Ohm Discrete input logic Negative logic (sink): : DI1...DI6, > 19 V (state 0) < 13 V (state 1) Positive logic (source): : DI1...DI6, < 5 V (state 0) > 11 V (state 1) Analogue output number 1 Analogue output type Software-configurable current (AQ1): 0...20 mA, impedance 800 Ohm, resolution 10 bits Software-configurable voltage (AQ1): 0...10 V, impedance 470 Ohm, resolution 10 bits Sampling duration Analog input (AI1, AI2, AI3): 2 ms Analog output (AQ1): 2 ms Accuracy Analog input AI1, AI2, AI3: +/- 0.2 % for a temperature of -10...60 C Analog input AI1, AI2, AI3: +/- 0.5 % for a temperature of 25 C Analog output AQ1: +/- 1 % for a temperature of 25 C Analog output AQ1: +/- 2 % for a temperature of -10...60 C Linearity error Analog input (AI1, AI2, AI3): +/- 0.2...0.5 % of maximum value Analog output (AQ1): +/- 0.3 % Discrete output number 3 Discrete output type Configurable relay logic NO/NC (R1A, R1B, R1C): electrical durability 100000 cycles Configurable relay logic NO (R2A, R2B): electrical durability 100000 cycles Logic (LO) Refresh time Logic input (DI1...DI6): 8 ms (+/- 0.7 ms) Relay output (R1A, R1B, R1C): 2 ms Relay output (R2A, R2C): 2 ms Minimum switching current Relay output (R1, R2): 5 mA at 24 V DC Maximum switching current Relay output (R1) on resistive load (cos phi = 1: 3 A at 250 V AC Relay output (R1) on resistive load (cos phi = 1: 4 A at 30 V DC Relay output (R1, R2) on inductive load (cos phi = 0.4: 2 A at 250 V AC Relay output (R1, R2) on inductive load (cos phi = 0.4: 2 A at 30 V DC Relay output (R2) on resistive load (cos phi = 1: 5 A at 250 V AC Relay output (R2) on resistive load (cos phi = 1: 5 A at 30 V DC Specific application Machinery Variable speed drive application selection Hoisting self erecting Material handling carousel Material handling conveyor Material handling lifting platfrom Material handling palletizers - medium performance Material handling transfer table Material handling turn table Material working (wood, ceramic, stone, pvc, metal) cutting - medium accuracy Material working (wood, ceramic, stone, pvc, metal) drilling Material working (wood, ceramic, stone, pvc, metal) saw Packaging bagging Packaging feed conveyor low performance Packaging filling bottles - intermittent operation Packaging linear labeling Packaging other application Packaging stretching wrapping Packaging tray take Textile knitting 3 Textile printing machines Textile spinning Washing machines car Washing machines other application Hoisting standard crane - travelling or trolley Motor power range 2.2...3 kW 200...240 V 1 phase Motor starter type Variable speed drive Environment Isolation Between power and control terminals Insulation resistance > 1 mOhm at 500 V DC for 1 minute to earth Noise level 48 dB conforming to 86/188/EEC Power dissipation in W 109.6 W (fan) at 200 V, 4 kHz Volume of cooling air 16 m3/h Operating position Vertical +/- 10 degree Electromagnetic compatibility Conducted radio-frequency immunity test conforming to IEC 61000-4-6 level 3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4 Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 1.2/50 s - 8/20 s surge immunity test conforming to IEC 61000-4-5 level 3 Pollution degree 2 conforming to EN/IEC 61800-5-1 Vibration resistance 1.5 mm peak to peak (f = 2...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6 Shock resistance 15 gn during 11 ms conforming to EN/IEC 60068-2-27 Relative humidity 5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3 Ambient air temperature for operation -10...50 C without derating 50...60 C with derating factor Ambient air temperature for storage -25...70 C Operating altitude <= 1000 m without derating 1000...3000 m with current derating 1 % per 100 m Environmental characteristic Chemical pollution resistance class 3C3 EN/IEC 60721-3-3 Dust pollution resistance class 3S2 EN/IEC 60721-3-3 Standards EN/IEC 61800-3 EN/IEC 61800-3 environment 1 category C2 EN/IEC 61800-5-1 IEC 60721-3 IEC 61508 IEC 13849-1 Product certifications CSA NOM 117 UL RCM EAC Marking CE Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1714 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Available Product Environmental Profile End of Life Information 4 Product datasheet Dimensions Drawings ATV320U22M2C Dimensions Right View, Front View and Front View with EMC Plate 5 Product datasheet Mounting and Clearance ATV320U22M2C Mounting Types Mounting Type A: Individual with Ventilation Cover Only Possible at Ambient Temperature Less or Equal to 50 C (122 F) Mounting Type B: Side by Side, Ventilation Cover Removed Mounting Type C: Individual, Ventilation Cover Removed For Operation at Ambient Temperature Above 50 C (122 F) 6 Product datasheet Connections and Schema ATV320U22M2C Connection Diagrams Diagram with Line Contactor Connection diagrams conforming to standards ISO13849 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1. (1) (2) Line choke (if used) Fault relay contacts, for remote signaling of drive status Diagram with Switch Disconnect Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1. (1) (2) Line choke (if used) Fault relay contacts, for remote signaling of drive status 7 Product datasheet Connections and Schema Control Connection Diagram in Source Mode (1) (2) (3) (4) Analog output Analog inputs Reference potentiometer (10 kOhm maxi) Digital inputs 8 ATV320U22M2C Product datasheet Connections and Schema ATV320U22M2C Digital Inputs Wiring The logic input switch (SW1) is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs. Switch SW1 set to "Source" position and use of the output power supply for the DIs. Switch SW1 set to "Source" position and use of an external power supply for the DIs. Switch SW1 set to "Sink Int" position and use of the output power supply for the DIs. Switch SW1 set to "Sink Ext" position and use of an external power supply for the DIs. 9 Product datasheet Performance Curves ATV320U22M2C Derating Curves Derating curve for the nominal drive current (In) as a function of temperature and switching frequency (SF). In : SF : 10 40 C (104 F) - Mounting type A, B and C 50 C (122 F) - Mounting type A, B and C 60 C (140 F) - Mounting type B and C Nominal Drive Current Switching Frequency