s h HK-A SERIES HK50A Single Output 10-150W HK100A HK150A HK-A ks HK10A F A F A HK15A HK25A 3 Y E A R S warranty ph Features f-a pf-a F A F A AC100Vin / Single output / Low cost Applicable to a wide range of applications, including FA industry facilities and medical equipment. F A F A 10-150 standard products: 6 models 30 types Model naming method HK 10A-5/ Blank: Open frame with screw terminal HK10A - HK150A A: Screw terminals, with cover 100W/150W type: Remote sensing available HK10A - HK150A B: Open frame & connector HK10A - HK50A C: Connectors & with cover HK10A - HK50A k-a hk-a Nominal output voltage Output power Series name ws hws Applications F A F A Conformity to RoHS Directive This means that, in conformity with EU Directive 2002/95/ EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. phaalpha Product Line up Output Voltage 3.3V p dlp 5V 12V 15V 24V 10W Output Current 2.0A 0.9A 0.7A 0.5A F A Model HK10A-3 HK10A-5 F A 15W Output Current 3.0A Model HK15A-3 HK15A-5 25W Output Current 5.0A 50W Model Output Current Model HK25A-3 10.0A HK50A-3 HK25A-5 10.0A HK50A-5 HK10A-12 1.3A HK15A-12 2.1A HK25A-12 4.2A HK50A-12 HK10A-15 1A HK15A-15 1.7A HK25A-15 3.4A HK50A-15 0.7A HK15A-24 1.1A HK25A-24 2.2A HK50A-24 F A HK10A-24 F A 100W Output Current 20.0A 8.5A Model HK100A-3 HK100A-5 150W Output Current 30.0A Model HK150A-3 HK150A-5 HK100A-12 12.5A HK150A-12 7A HK100A-15 10A HK150A-15 4.5A HK100A-24 6.5A HK150A-24 ps fps F A F A All specifications are subject to change without notice. A-75 HK10A HK10A ITEMS/UNITS HK10A Specifications MODEL Voltage Range Frequency Input Efficiency (typ) Current (100VAC)(typ) Inrush Current (100VAC)(typ) Nominal Voltage Maximum Current Maximum Power Maximum Line Regulation Output Maximum Load Regulation Temperature Coefficient (typ) Maximum Ripple & Noise Hold-up Time (typ) Voltage Adjustable Range Over Current Protection Function Over Voltage Protection Series Operation Operating Temperature Storage Temperature Operating Humidity Environment Storage Humidity Vibration Shock Cooling HK-A Isolation Withstand Voltage HK10A-3 (*2) (*2) (*1) (*1) V Hz A A VDC A W (*3) mV (*4) mV (*8) mVp-p (*1) ms HK10A-5 67 0.2 71 3.3 5 2.0 6.6 10.0 20 40 HK10A-24 74 78 15 0.7 10.5 60 120 24 0.5 12.0 96 150 150 20 10% >105% >115% Possible 0 to +50 (100%), 60 (50%) -30 to +85 30 - 90 10 - 95 10-55Hz (sweep 1 min) less than 19.6m/s X, Y, Z 1 h each Less than 196.1m/s Convection Cooled RH RH Input - Chassis , Input - Output : 2VAC (20mA) Output - Chassis : 500VAC (100mA) for 1min (*9) Isolation Resistance Standards AC85-132 or DC110-175 47-440 73 0.3 20 12 0.9 10.8 48 96 1% at 0 to +50 HK10A-15 120 (*5) (*6) (*7) HK10A-12 More than 100M Ohm at 25 and 70%RH Output-FG 500VDC Approved by UL60950-1, CSA C22.2 No.60950. Built to meet DENAN. (HK10A-3 is built to meet safety standards.) Safety Standards EMI Weight Mechanical Size (W x H x D) Built to meet FCC class B, VCCI - B 150 22 x 68 x 68 (Refer to outline drawing) g mm Recommended EMC Filter (*1) At 100VAC and maximum output power, Ta = 25 (*2) For cases where conformance to various safety specs (UL, CSA) are required to be described as 100-120VAC, 50/60Hz on name plate. (*3) From 85 to 132VAC or 110 to 175VDC, constant load. (*4) From no load to full load, constant input voltage. (*5) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. (*6) Over voltage clamping by zener diode. RSEL-20R5W Please refer to "TDK-Lambda EMC Filters" catalog. (*7) At standard mounting (vertical). (*8) Constant input voltage & load. (*9) Refer to instruction manual for testing procedure. Derating Curve Without cover With cover 120 Load (%) Load (%) 90 Mounting C, D 80 60 PCB C, D 70 60 50 (A) (B) (C) (D) (E)Don't use 20 20 A-76 A 80 40 40 0 B 100 Mounting A, B 100 0 10 20 30 40 Ta () 50 60 70 0 10 20 30 40 50 60 70 Ta () Recommended standard mounting method is (A). (B), (C), (D) are also possible, but please use within the range of derating. Please do not use (E), where the PCB will be on the top side and heat will be trapped inside the unit. All specifications are subject to change without notice. HK 10A Outline Drawing HK10A Please see A-88 for HK10A/A and HK10A/C (with cover). COMPONENT SIDE TERMINAL COVER COMPONENT SIDE NOTE A 36.00.536.00.5 TERMINAL COVER NOTE A 68.01 68.01 72.01 72.01 Screw terminal HK-A 72.01 72.01 === MATERIALS === 26.01 26.01 NOTE A Frame: Iron PCB: NAME PLATE Composite (CEM-3 UL94V-0) single side NOTE A === NOTES === A: M3 tapped holes (4) for customer chassis mounting. (Screws must not protrude into power supply by more than 5mm) NAME PLATE SEE NOTE B&C B: Model name and nominal output voltage and maximum output current are shown here in accordance with the specifications. unit : mm C: Country of manufacturer will be shown here. D: C-UL-US & CE Marking (only 5V, 12V, 15V & 24V) SEE NOTE B&C HK10A/B OUTPUT CONNECTOR FG - ACL NC FG ACL NC NOTE A COMPONENT SIDE NOTE A ACN ACN FG INPUT CONNECTOR 5289-04A (MOLEX) COMPONENT SIDE NOTE A 36 - OUTPUT CONNECTOR INPUT CONNECTOR 5273-04A 5289-04A (MOLEX) (MOLEX) INPUT CONNECTOR 5289-04A (MOLEX) - 681 COMPONENT SIDE 681 (MOLEX) OUTPUT CONNECTOR 5273-04A (MOLEX) 36 5273-04A With connector ACL 36 NC ACN === NOTES === B: Model name and nominal output voltage and maximum output current are shown here in accordance with the specifications. C: Country of manufacturer will be shown here. D: C-UL-US & CE Marking (only 5V, 12V, 15V & 24V) E: ACCESSORIES : HOUSINGS 5199-04 (MOLEX) --- NET 1 5195-04 (MOLEX) --- NET 1 TERMINALS 5194PBT (MOLEX) --- NET 7 All specifications are subject to change without notice. NOTE A NAME PLATE NAME PLATE 221 (Screws must not protrude into power supply by more than 5mm.) NOTE A NOTE A NAME SEE NOTE B&C unit : mm SEE NOTE B&C PLATE 221 A: M3 tapped holes (4) for customer chassis mounting. A-77 HK15A HK15A Specifications ITEMS/UNITS MODEL Voltage Range Frequency Input Efficiency (typ) Current (100VAC)(typ) Inrush Current (100VAC)(typ) Nominal Voltage Maximum Current Maximum Power Maximum Line Regulation Output Maximum Load Regulation Temperature Coefficient (typ) Maximum Ripple & Noise Hold-up Time (typ) Voltage Adjustable Range Over Current Protection Function Over Voltage Protection Series Operation Operating Temperature Storage Temperature Operating Humidity Environment Storage Humidity Vibration Shock Cooling HK-A Isolation Withstand Voltage HK15A-3 (*2) (*2) (*1) (*1) V Hz A A VDC A W (*3) mV (*4) mV (*8) mVp-p (*1) ms HK15A-5 66 0.3 69 3.3 3.0 9.9 5 3 15.0 20 40 HK15A-24 75 77 15 1 15.0 60 120 24 0.7 16.8 96 150 150 20 10% >105% >115% Possible 0 to +50 (100%), 60 (50%) -30 to +85 30 - 90 10 - 95 10-55Hz (sweep 1 min) less than 19.6m/s X, Y, Z 1 h each Less than 196.1m/s Convection Cooled RH RH Input - Chassis , Input - Output : 2kVAC (20mA) Output - Chassis : 500VAC (100mA) for 1min (*9) Isolation Resistance Standards AC85-132 or DC110-175 47-440 74 0.4 30 12 1.3 15.6 48 96 1% at 0 to +50 HK15A-15 120 (*5) (*6) (*7) HK15A-12 More than 100M Ohm at 25 and 70%RH Output-FG 500VDC Approved by UL60950-1, CSA C22.2 No.60950. Built to meet DENAN. (HK15A-3 is built to meet safety standards.) Safety Standards EMI Weight Mechanical Size (W x H x D) Built to meet FCC class B, VCCI - B 170 23.5 x 68 x 80 (Refer to outline drawing) g mm Recommended EMC Filter (*1) At 100VAC and maximum output power, Ta = 25 (*2) For cases where conformance to various safety specs (UL, CSA) are required to be described as 100-120VAC, 50/60Hz on name plate. (*3) From 85 to 132VAC or 110 to 175VDC, constant load. (*4) From no load to full load, constant input voltage. (*5) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. (*6) Over voltage clamping by zener diode. RSEL-2001W Please refer to "TDK-Lambda EMC Filters" catalog. (*7) At standard mounting (vertical). (*8) Constant input voltage & load. (*9) Refer to instruction manual for testing procedure. OUTPUT DERATING Without cover With cover 120 Load (%) Load (%) 90 Mounting C, D 80 60 PCB C, D 70 60 50 (A) (B) (C) (D) (E)Don't use 20 20 A-78 A 80 40 40 0 B 100 Mounting A, B 100 0 10 20 30 40 Ta () 50 60 70 0 10 20 30 40 50 60 70 Ta () Recommended standard mounting method is (A). (B), (C), (D) are also possible, but please use within the range of derating. Please do not use (E), where the PCB will be on the top side and heat will be trapped inside the unit. All specifications are subject to change without notice. HK 15A Outline Drawing HK15A Please see A-89 for HK15A/A and HK15A/C (with cover). With screw terminal 10.7 5-M3 8.2 TERMINAL COVER 68.0 1 COMPONENT SIDE SEE NOTE A 13.5 36.0 0.5 9.5 62.8 61.5 - 2.5 12.6 HK-A 55.0 0.5 9.0 11.3 80.0 1 === MATERIALS === NAME PLATE Frame: Iron Composite (CEM-3 UL94V-0) single side 12.0 PCB: === NOTES === A: M3 tapped holes (4) for customer chassis mounting. 23.5 1 SEE NOTE A SEE NOTE B&C (Screws must not protrude into power supply by more than 5mm.) B: Model name and nominal output voltage and maximum output cur- 1.5 74.0 0.5 rent are shown here in accordance with the specifications. (unit : mm) C: Country of manufacturer will be shown here. D: C-UL-US & CE Marking (only 5V,12V,15V & 24V) HK15A/B 9.4 9.4 - FG SEE NOTE A ACL FG FG NC ACL ACL ACN NC NC SEE NOTE A NOTE A SEE 36 ACNACN 550.5 9 2.5 9 2.5 === NOTES === 681 - COMPONENT SIDE SIDE COMPONENT 9 2.5 550.5 550.5 801 801 A: M3 tapped holes (4) for customer chassis mounting. SEE NOTE A (Screws must not protrude into power supply by more than 5mm.) 801 SEE NOTE B&C B&CNOTE B&C SEE NOTESEE A NOTE A SEE NOTESEE B: Model name and nominal output voltage and maximum output cur- 5195-04 (MOLEX) --- NET 1 NAME PLATE NAME PLATE TERMINALS 5194PBT (MOLEX) --- NET 7 All specifications are subject to change without notice. 1.5 1.5 1.5 740.5 740.5 740.5 12 (MOLEX) --- NET 1 12 5199-04 12 NAME PLATE D: C-UL-US & CE Marking (only 5V,12V,15V & 24V) 23.51 rent are shown here in accordance with the specifications. C: Country of manufacturer will be shown here. E: ACCESSORIES : HOUSINGS 681 - 62.6 62.6 62.6 61.5 61.5 61.5 INPUT CONNECTOR 5289-04A (MOLEX) INPUT CONNECTOR INPUT CONNECTOR 5289-04A 5289-04A (MOLEX) (MOLEX) COMPONENT SIDE 23.51 23.51 OUTPUT CONNECTOR 5273-04A (MOLEX) OUTPUT CONNECTOR OUTPUT CONNECTOR 5273-04A 5273-04A (MOLEX) (MOLEX) 681 9.4 10.7 36 10.7 36 10.7 With connectors unit : mm A-79 HK25A HK25A ITEMS/UNITS HK25A Specifications MODEL Voltage Range Frequency Input Efficiency (typ) Current (100VAC)(typ) Inrush Current (100VAC)(typ) Nominal Voltage Maximum Current Maximum Power Maximum Line Regulation Output Maximum Load Regulation Temperature Coefficient (typ) Maximum Ripple & Noise Hold-up Time (typ) Voltage Adjustable Range Over Current Protection Function Over Voltage Protection Series Operation Operating Temperature Storage Temperature Operating Humidity Environment Storage Humidity Vibration Shock Cooling HK-A Isolation Withstand Voltage HK25A-3 (*2) (*2) (*1) (*1) (*3) V Hz A A VDC A W (*4) mV (*5) mV (*9) mVp-p (*1) ms HK25A-5 70 0.5 72 3.3 5.0 16.5 5 5.0 25.0 20 40 HK25A-24 77 80 15 1.7 25.5 60 120 24 1.1 26.4 96 150 150 20 10% >105% 115% to 135% Possible 0 to +50 (100%), 60 (50%) -30 to +85 30 - 90 10 - 95 10-55Hz (sweep 1 min) less than 19.6m/s X, Y, Z 1 h each Less than 196.1m/s Convection Cooled RH RH Input-Chassis, Input-Output : 2kVAC (20mA) Output-Chassis : 500VAC (100mA) for 1min (*10) Isolation Resistance Standards AC85-132 or DC110-175 47-440 76 0.6 15 12 2.1 25.2 48 96 1% at 0 to +50 HK25A-15 120 (*6) (*7) (*8) HK25A-12 More than 100M at 25 and 70% RH Output-FG 500VDC Approved by UL60950-1, CSA C22.2 No.60950. Built to meet DENAN. (HK25A-3 is built to meet safety standards.) Safety Standards EMI Weight Mechanical Size (W x H x D) Built to meet FCC class B,VCCI-B 230 28 x 68 x 95 (Refer to outline drawing) g mm Recommended EMC Filter (*1) At 100VAC & maximum output power,Ta = 25 . (*2) For cases where conformance to various safety specs (UL, CSA) are required to be described as 100-120VAC, 50/60Hz on name plate. (*3) Typical value on cold start, Ta=25. (*4) From 85 to 132VAC or 110 to 175VDC, constant load. (*5) From no load to full load, constant input voltage. (*6) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. RSEL-2001W Please refer to "TDK-Lambda EMC Filters" catalog. (*7) Inverter shut down, manual reset. (*8) At standard mounting (vertical). (*9) Constant input voltage & load. (*10) Refer to instruction manual for testing procedure. OUTPUT DERATING Without cover With cover 120 Load (%) Load (%) 90 Mounting B 80 Mounting C, D 60 PCB C, D 70 60 50 (A) (B) (C) (D) (E)Don't use 20 20 A-80 A 80 40 40 0 B 100 Mounting A 100 0 10 20 30 40 Ta () 50 60 70 0 10 20 30 40 50 60 70 Ta () Recommended standard mounting method is (A). (B), (C), (D) are also possible, but please use within the range of derating. Please do not use (E), where the PCB will be on the top side and heat will be trapped inside the unit. All specifications are subject to change without notice. HK 25A Outline Drawing HK25A Please see A-90 for HK25A/A and HK25A/C (with cover). With screw terminal 10.7 COMPONENT SIDE 9.5 62.9 36.0 0.5 SEE NOTE A 13.5 61.5 - 68.0 1 TERMINAL COVER 4.5 12.6 70.0 0.5 10.5 95.0 1 11.3 WITH COVER 99.0 1 === MATERIALS === PCB: 88.0 0.5 4.0 Frame: Iron Composite (CEM-3 UL94V-0) single side SEE NOTE C&D SEE NOTE B SEE NOTE B SEE NOTE A === NOTES === 8.0 A: M3 tapped holes (5) for customer chassis mounting. (Screws must not protrude into power supply by more than 5mm.) NAME PLATE B: 3.5 holes (2) for customer chassis mounting. 15.0 (Use M3 mounting screws.) C: Model name and nominal output voltage and maximum output current are shown here in accordance with the specifications. 83.0 0.5 0.5 D: Country of manufacturer will be shown here. HK-A 28.0 1 8.2 5-M3 unit: mm 7.0 0.5 E: C-UL-US & CE Marking (only 5V, 12V, 15V & 24V) With connectors HK25A/B 9.4 FG FG NC SEE NOTE A SEE NOTE A ACL NC ACN ACN 10.5 4.5 10.5 4.5 95 1 88 0.5 SEE NOTE B 8 (Screws must not protrude into power supply by more than 5mm.) B: 3.5 Holes (2) for customer chassis mounting. NAME PLATE (Use M3 mounting screws.) C: Model name and nominal output voltage and maximum output cur- SEE NOTE C&D rent are shown here in accordance with the specifications. D : Country of manufacturer will be shown here. E : ACCESSORIES HOUSING 5199-04 (MOLEX) --- NET 1 5195-04 (MOLEX) --- NET 1 TERMINALS 5194PBT (MOLEX) --- NET 7 F : C-UL-US & CE Marking (only 5V, 12V, 15V & 24V) 0.5 28 1 SEE NOTE B SEE NOTE A 15 A: M3 tapped holes (5) for customer chassis mounting. 70 0.5 95 1 4 === NOTES === 70 0.5 36 ACL COMPONENT SIDE COMPONENT SIDE 68 1 61.5 62.9 INPUT CONNECTOR INPUT CONNECTOR 5289-04A 5289-04A (MOLEX) (MOLEX) 61.5 OUTPUT CONNECTOR OUTPUT CONNECTOR 5273-04A 5273-04A (MOLEX) (MOLEX) 68 1 10.7 36 9.4 62.9 10.7 83 0.5 7 0.5 unit: mm A-81 HK50A HK50A Specifications ITEMS/UNITS MODEL Voltage Range Frequency Input Efficiency (typ) Current (100VAC)(typ) Inrush Current (100VAC)(typ) Nominal Voltage Maximum Current Maximum Power Maximum Line Regulation Output Maximum Load Regulation Temperature Coefficient(typ) Maximum Ripple & Noise Hold-up Time (typ) Voltage Adjustable Range Over Current Protection Function Over Voltage Protection Series Operation Operating Temperature Storage Temperature Operating Humidity Environment Storage Humidity Vibration Shock Cooling HK-A Isolation Withstand Voltage HK50A-3 (*2) (*2) (*1) (*1) (*3) V Hz A A VDC A W (*4) mV (*5) mV (*9) mVp-p (*1) ms HK50A-5 74 0.8 79 3.3 10.0 33 5 10.0 50.0 20 40 HK50A-24 82 84 15 3.4 51.0 60 120 24 2.2 52.8 96 150 150 20 10% >105% 115%~135% Possible 0 to +50 (100%), 60 (50%) -30 to +85 30 - 90 10 - 95 10-55Hz (sweep 1 min) less than 19.6m/s X, Y, Z 1 h each Less than 196.1m/s Convection Cooled RH RH Input - Chassis, Input - Output : 2kVAC (20mA) Output - Chassis : 500VAC (100mA) for 1min (*10) Isolation Resistance Standards AC85-132 or DC110-175 47-440 81 1.2 30 12 4.2 50.4 48 96 1% at 0 to +50 HK50A-15 120 (*6) (*7) (*8) HK50A-12 More than 100M Ohm at 25 and 70%RH Output-FG 500VDC Approved by UL60950-1, CSA C22.2 No.60950. Built to meet DENAN. (HK50A-3 is built to meet safety standards.) Safety Standards EMI Weight Mechanical Size (W x H x D) Built to meet FCC class B, VCCI - B 280 31 x 68 x 119 (Refer to outline drawing) g mm Recommended EMC Filter (*1) At 100VAC & maximum output power,Ta = 25 . (*2) For cases where conformance to various safety specs (UL, CSA) are required to be described as 100-120VAC, 50/60Hz on name plate. (*3) Typical value on cold start, Ta=25. (*4) From 85 to 132VAC or 110 to 175VDC, constant load. (*5) From no load to full load, constant input voltage. (*6) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. RSEL-2002W Please refer to "TDK-Lambda EMC Filters" catalog. (*7) Inverter shut down, manual reset. (*8) At standard mounting (vertical). (*9) Constant input voltage & load. (*10) Refer to instruction manual for testing procedure. OUTPUT DERATING Without cover With cover 120 60 Load (%) Load (%) 90 Mounting B 80 Mounting C, D PCB C, D 70 60 50 (A) (B) (C) (D) (E)Don't use 20 20 A-82 A 80 40 40 0 B 100 Mounting A 100 0 10 20 30 40 Ta () 50 60 70 0 10 20 30 40 50 60 70 Ta () Recommended standard mounting method is (A). (B), (C), (D) are also possible, but please use within the range of derating. Please do not use (E), where the PCB will be on the top side and heat will be trapped inside the unit. All specifications are subject to change without notice. HK 50A Outline Drawing HK50A Please see A-91 for HK50A/A and HK50A/C (with cover). With screw terminal TERMINAL COVER + COMPONENT SIDE - - FG 681 8.2 9.5 SEE NOTE A 34 L 13.5 N 11.3 26 700.5 HK-A 1191 === MATERIALS === 1110.5 Frame: Aluminum Composite (CEM-3 UL94V-0) single side SEE NOTE A SEE NOTE B A: M3 TAPPED HOLES(4) FOR CUSTOMER CHASSIS MOUNTING. SCREWS MUST NOT PROTRUDE INTO NAME PLATE 17 POWER SUPPLY BY MORE THAN 5mm. B: 3.5 HOLES(2) FOR CUSTOMER CHASSIS MOUNTING. 311 === NOTES === 28 PCB: SEE NOTE B (USE M3 MOUNTING SCREWS) 5 C: MODEL NAME, NOMINAL OUTPUT VOLTAGE, MAXIMUM 1000.5 OUTPUT CURRENT ARE SHOWN HERE IN ACCORDANCE (unit : mm) WITH THE SPECIFICATIONS. D: COUNTRY OF MANUFACTURE WILL BE SHOWN HERE. E: C-UL-US & CE MARKING (ONLY 5V,12V,15V & 24V) HK50A/B With connector 9.4 - INPUT CONNECTOR COMPONENT SIDE 63.8 5273-04A (MOLEX) 63.0 OUTPUT CONNECTOR 681 12.2 SEE NOTE A 34 5289-04A (MOLEX) 700.5 26 === NOTES === A: M3 TAPPED HOLES(4) FOR CUSTOMER CHASSIS MOUNTING. MUST NOT PROTRUDE INTO ( SCREWS POWER SUPPLY BY MORE THAN 5mm. ) 1191 SEE NOTE B 110.00.5 SEE NOTE A MOUNTING. (USE M3 MOUNTING SCREWS.) NAME PLATE (*1) SEE NOTE C, D&E 17 MAXIMUM OUTPUT CURRENT ARE SHOWN HERE 28 C: MODEL NAME, NOMINAL OUTPUT VOLTAGE, 311 B: 3.5 HOLES(2) FOR CUSTOMER CHASSIS IN ACCORDANCE WITH THE SPECIFICATIONS. D: COUNTRY OF MANUFACTURE WILL BE SHOWN 100.00.5 HERE. E: C-UL-US & CE MARKING (ONLY 5V, 12V, 15V & 24V) F: ACCESSORIES : HOUSINGS (unit : mm) SEE NOTE B 5199-04 (MOLEX) --- NET 1 5195-04 (MOLEX) --- NET 1 TERMINALS 5194PBT (MOLEX) --- NET 7 All specifications are subject to change without notice. A-83 HK100A HK100A Specifications ITEMS/UNITS MODEL Voltage Range Frequency Input Efficiency (typ) Current (100VAC)(typ) Inrush Current (100VAC)(typ) Nominal Voltage Maximum Current Maximum Power Maximum Line Regulation Output Maximum Load Regulation Temperature Coefficient (typ) Maximum Ripple & Noise Hold-up Time (typ) Voltage Adjustable Range (typ) Over Current Protection Over Voltage Protection Remote Sensing Function Remote ON/OFF Control Parallel Operation Series Operation Operating Temperature Storage Temperature Operating Humidity Environment Storage Humidity Vibration Shock Cooling HK-A Isolation Withstand Voltage HK100A-3 (*2) (*2) (*1) (*1) V Hz A A VDC A W (*3) mV (*4) mV HK100A-5 75 1.5 80 3.3 5 20 66 100.0 20 40 mVp-p (*1) ms AC85-132 or DC110-175 47-440 81 2.2 15 12 8.5 102.0 48 96 1% at -10 to +50 HK100A-24 82 15 7 105.0 60 120 24 4.5 108.0 96 150 150 20 10% >105% 115% - 135% Possible Possible -10 to +50 (100%), 60 (50%) -30 to +85 30 - 90 10 - 95 Less than 19.6m/s Less than 196.1m/s Convection cooled RH RH Input - Chassis, Input - Output : 2kVAC (20mA) Output - Chassis : 500VAC (100mA) for 1min (*7) Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) HK100A-15 120 (*5) (*6) (*8) HK100A-12 More than 100M Ohm at 25 and 70%RH, Output-Chassis 500VDC Approved by UL60950-1, CSA C22.2 No.60950. Built to meet DENAN. Built to meet FCC class B, VCCI - B 540 34.5 x 93 x 150 (Refer to outline drawing) g mm Recommended EMC Filter (*1) At 100VAC & maximum output power, Ta = 25 . (*2) For cases where conformance to various safety specs (UL, CSA, VDE) are required to be described as 100-120VAC, 50/60Hz on name plate. (*3) From 85-132VAC or 110 - 175VDC, constant load. (*4) From no load to full load, constant input voltage. (*5) Current limiting with automatic recovery. (Refer to instruction manual for details.) (*6) Inverter shutdown method, manual reset. RSEN-2006 Please refer to "TDK-Lambda EMC Filters" catalog. (*7) Refer to instruction manual for testing procedure. (*8) Ratings - Refer to derating curve on the right. - Load(%) is percent of maximum output power or maximum output current, whichever is greater. - Refer to instruction manual for further mounting details. OUTPUT DERATING WithoutCover : Open Frame Type 90 Mounting: A Load (%) 80 Mounting: B 70 60 50 40 Mounting: C, D 20 90 A, B 80 70 C, D 60 PCB 50 (A) (Standard) 20 10 A-84 100 40 30 0 -10 With cover Load (%) 100 0 10 20 30 40 50 60 70 Ta () -10 0 10 20 30 40 50 60 70 Ta () (B) (C) (D) (E)Don't use Recommended standard mounting method is (A). (B), (C), (D) are also possible, but please use within the range of derating. Please do not use (E), where the PCB will be on the top side and heat will be trapped inside the unit. All specifications are subject to change without notice. HK 100A Outline Drawing With screw terminal HK100A COVER COVER TERMINAL TERMINAL COVER COVER COVER TERMINAL COVER COMPONENT COMPONENT SIDE COMPONENT SIDE SIDE SEE NOTE A SEE NOTESEE A NOTE A HK-A === NOTES === A: M4 tapped holes for customer chassis mounting. SEE NOTESEE A NOTE A (Screws must not protrude into power supply by more than 6mm.) SEE NOTE A B: 4.5 holes (2) for customer chassis mounting. C: Country of manufacture will be shown here. D: Model name and nominal output voltage and maximum output current are shown here in accordance with the specifications. SEE NOTE B SEE NOTE B NAME PLATE NAME SEE NOTE C, D&E PLATE SEE NOTE C,D&E SEE NOTE C,D&E E: C-UL-US and CE Marking (Only 3.3V, 5V, 12V, 15V and 24V) (unit : mm) ===ACCESSORIES=== * COVER FOR BARRIER TERMINAL STRIP --- 1 (MOUNTED ON TERMINAL STRIP AT TIME OF SHIPMENT. ) === MATERIALS === * METAL PIESES FOR SHORTING PURPOSES --- 2 Frame: Aluminum (MOUNTED ON TERMINAL STRIP AT TIME OF SHIPMENT. ) PCB: Composite (CEM-3 UL94V-0) single side With cover HK100A/A COVER COVER TERMINAL COVER COVER TERMINAL COMPONENT SIDE SIDE COMPONENT SEE NOTE A NOTE A SEE === NOTES === A: M4 tapped holes for customer chassis mounting. SEE NOTE A NOTE A SEE (Screws must not protrude into power supply by more than 6mm) B: 4.5 holes (2) for customer chassis mounting. SEE NOTE B SEE NOTE B C: Country of manufacture will be shown here. D: Model name and nominal output voltage and maximum output current are shown here in NAME PLATE NAME PLATE SEE NOTESEE C, D&E NOTE C, D&E accordance with the specifications. ===ACCESSORIES=== *COVER FOR BARRIER TERMINAL STRIP --- 1 (MOUNTED ON TERMINAL STRIP AT TIME OF SHIPMENT. ) (unit : mm) *METAL PIESES FOR SHORTING PURPOSES --- 2 (MOUNTED ON TERMINAL STRIP AT TIME OF SHIPMENT. ) All specifications are subject to change without notice. A-85 HK150A HK150A Specifications ITEMS/UNITS HK-A MODEL Voltage Range (*2) Frequency (*2) Input Efficiency (typ) (*1) Current (100VAC)(typ) (*1) Inrush Current (100VAC)(typ) Nominal Voltage Maximum Current Maximum Power Maximum Line Regulation (*3) Output Maximum Load Regulation (*4) Temperature Coefficient (%)(typ) Maximum Ripple & Noise Hold-up Time (typ) (*1) Voltage Adjustable Range (typ) Over Current Protection (*5) Over Voltage Protection (*6) Remote Sensing Function Remote ON/OFF Control Parallel Operation Series Operation Operating Temperature (*8) Storage Temperature Operating Humidity Environment Storage Humidity Vibration Shock Cooling Isolation Withstand Voltage HK150A-3 V Hz A A VDC A W mV mV HK150A-5 75 2.2 80 3.3 5 30 99 20 40 mVp-p ms HK150A-15 AC85-132 or DC110-175 47-440 81 3.2 15 12 12.5 150 48 96 1% at -10 to +50 120 HK150A-24 82 15 10 24 6.5 156 96 150 60 120 150 20 10% >105% 115%-135% Possible Possible -10 to +50 (100%), 60 (50%) -30 to +85 30 - 90 10 - 95 Less than 19.6m/s Less than 196.1m/s Convection cooled RH RH Input - Chassis, Input - Output : 2kVAC (20mA) Output - Chassis : 500VAC (100mA) for 1min (*7) Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) HK150A-12 More than 100M Ohm at 25 and 70%RH Output - Chassis 500VDC Approved by UL60950-1, CSA C22.2 No.60950. Built to meet DENAN. Built to meet FCC class B, VCCI - B 650 43 x 93 x 170 (Refer to outline drawing) g mm (*1) At 100VAC & maximum output power, Ta = 25 . Recommended EMC Filter (*2) For cases where conformance to various safety specs (UL, CSA, VDE) are required to be described as 100-120VAC, 50/60Hz on name plate. (*3) From 85-132VAC or 110-175VDC, constant load. (*4) From no load to full load, constant input voltage. (*5) Current limiting with automatic recovery. (Refer to instruction manual for details.) (*6) Inverter shutdown method, manual reset. (*7) Refer to instruction manual for testing procedure. RSEN-2006 Please refer to "TDK-Lambda EMC Filters" catalog. (*8) Ratings - Refer to derating curve on the right. - Load(%) is percent of maximum output power or maximum output current, whichever is greater. - Refer to instruction manual for further mounting details. OUTPUT DERATING Without Cover : Open Frame Type 90 Mounting A 100 90 80 Load (%) With cover 70 Mounting B 60 50 Mounting C, D 40 30 20 Load (%) 100 A 80 70 60 50 C, D 40 (A) (Standard) 20 10 0 -10 A-86 0 10 20 30 40 50 60 70 Ta () -10 0 PCB B 10 20 30 40 50 60 70 Ta () (B) (C) (D) (E)Don't use Recommended standard mounting method is (A). (B), (C), (D) are also possible, but please use within the range of derating. Please do not use (E), where the PCB will be on the top side and heat will be trapped inside the unit. All specifications are subject to change without notice. HK 150A Outline Drawing With screw terminal HK150A COVER COVER TERMINAL COVER TERMINAL COVER COMPONENTCOMPONENT SIDE SIDE SEE NOTE ASEE NOTE A HK-A === NOTE === A: M4 TAPPED HOLES FOR CUSTOMER CHASSIS MOUNTING. SCREWS MUST NOT PROTRUDE INTO SEE NOTE BSEE NOTE B POWER SUPPLY BY MORE THAN 6mm. B: 4.5 HOLES(2) FOR CUSTOMER CHASSIS MOUNTING. NAME PLATENAME PLATE C: COUNTRY OF MANUFACTURE WILL BE SHOWN HERE. D: MODEL NAME, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT ARE SHOWN HERE IN AC- SEE NOTE ASEE NOTE A SEE NOTE C,SEE D &NOTE E C, D & E CORDANCE WITH THE SPECIFICATIONS. E: C-UL-US and CE Marking (Only 3.3V, 5V, 12V, 15V and 24V) (unit: mm) === ACCESSORIES === === MATERIALS === COVER FOR BARRIER TERMINAL STRIP --- 1 Frame: Aluminum (MOUNTED ON TERMINAL STRIP AT TIME OF SHIPMENT) PCB: Composite (CEM-3 UL94V-0) single side METAL PIECES FOR SHORTING PURPOSES --- 2 (++S & --S) (MOUNTED ON TERMINAL STRIP AT TIME OF SHIPMENT) With cover HK150A/A COVER COVER COVER TERMINAL TERMINAL COVER COMPONENT SIDE COMPONENT SIDE NOTE A SEE NOTE SEE A === NOTE === A: M4 TAPPED HOLES FOR CUSTOMER CHASSIS MOUNTING. SCREWS MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN 6mm. B: 4.5 HOLES(2) FOR CUSTOMER CHASSIS MOUNTING. NAME PLATE NAME PLATE NOTE B SEE NOTE SEE B C: COUNTRY OF MANUFACTURE WILL BE SHOWN HERE. D: MODEL NAME, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. NOTE A SEE NOTE SEE A NOTE C,D&E SEE NOTE SEE C,D&E === ACCESSORIES === COVER FOR BARRIER TERMINAL STRIP --- 1 (MOUNTED ON TERMINAL STRIP AT TIME OF SHIPMENT) (unit: mm) METAL PIECES FOR SHORTING PURPOSES --- 2 (++S & --S) (MOUNTED ON TERMINAL STRIP AT TIME OF SHIPMENT) All specifications are subject to change without notice. A-87 HK 10A/A, /C HK10A/A Screw terminals with cover - TERMINAL COVER COVER TERMINAL - - TERMINAL COVER COMPONENT SIDE COMPONENT SIDE COMPONENT SIDE - HK-A 36.0 36.0 NOTENOTE A NOTE A A 72.01 - 72.01 - 72.01 36.0 500.5 500.5 500.5 721 721 721 261 12 NAME PLATE B: Model name and nominal output voltage and maximum output current are NAME NAME PLATEPLATE shown here in accordance with the specifications. C: Country of manufacturer will be shown here. 6 D: C-UL-US & CE Marking (only 5V, 12V, 15V & 24V) 6 260.5 SEE NOTE B&C 12 trude into power supply by more than 5mm) 261 NOTE A NOTE A 12 A: M3 tapped holes (4) for customer chassis mounting. (Screws must not pro- SEE NOTE SEEB&C NOTE B&Cunit: 6260.5 260.5 261 NOTE A === NOTES === mm HK10A/C With connector and cover OUTPUT CONNECTOR OUTPUT CONNECTOR OUTPUT CONNECTOR 5273-04A (MOLEX) 5273-04A (MOLEX) 5273-04A (MOLEX) COMPONENT SIDE COMPONENT SIDE COMPONENT SIDE NOTE A NOTE NOTE A A 721 721 FG FG FG INPUT CONNECTOR INPUT CONNECTOR INPUT CONNECTOR 5289-04A (MOLEX) 721 -- - ACL 36 NC NC NC ACN ACN ACN 36 36 ACL ACL 5289-04A (MOLEX) 5289-04A (MOLEX) 721 721 721 === NOTES === A: M3 tapped holes (4) for customer chassis mounting. (Screws must not protrude into power supply by more than 5mm.) B: Model name and nominal output voltage and maximum output current are shown here in accordance with the specifications. C: Country of manufacturer will be shown here. D: Accessories : Housings 5199-04 (MOLEX) --- NET 1 Terminals 5194PBT (MOLEX) --- NET 7 5195-04 (MOLEX) --- NET 1 E: C-UL-US & CE Marking (only 5V,12V,15V & 24V) NOTE A NOTE NOTE A A NAME PLATE NAME PLATE NAME PLATE SEE NOTE B&C unit: mm NOTE B&C SEESEE NOTE B&C A-88 All specifications are subject to change without notice. HK 15A/A, /C HK15A/A 9.4 Screw terminals with cover 10.7 8.2 - - - 721 721 721 9.5 13.5 COMPONENT SIDE COMPONENT COMPONENT SIDESIDE SEE NOTE A NOTE SEESEE NOTE A A 36 36 36 9.5 9.5 ACL ACL ACL 13.5 13.5 FG FG 62.6 ACN ACN ACN 12.6 12.612.6 2.5 2.5 2.5 99 9 HK-A 550.5 550.5 550.5 841 841 841 11.3 11.311.3 A: M3 tapped holes (4) for customer chassis mounting. NAME PLATE NAME PLATE NAME PLATE (Screws must not protrude into power supply by more than 5mm) B: Model name and nominal output voltage and maximum output current are shown here in accordance with the specifications. C: Country of manufacturer will be shown here. 1.5 1.5 1.5 D: C-UL-US & CE Marking (only 5V,12V,15V & 24V) SEE SEE NOTE NOTENOTE B&C B&C SEE B&C 27.51 27.51 SEE A SEE AA SEENOTE NOTENOTE === NOTES === 12 12 12 27.51 FG TERMINAL COVER TERMINAL COVER TERMINAL COVER - - 61.5 62.6 62.6 - 61.5 61.5 5M3 5M3 5M3 8.2 8.2 10.710.79.4 9.4 740.5 740.5 740.5 unit : mm HK15A/C With connector and cover 10.7 10.7 9.49.4 9.4 10.7 COMPONENT SIDE COMPONENT SIDE COMPONENT SIDE FGFG FG ACL ACL ACL NC NC SEE NOTE A A SEE NOTE SEE NOTE A 36 36 INPUT CONNECTOR INPUT CONNECTOR 5289-04A 5289-04A INPUT CONNECTOR (MOLEX) (MOLEX) 5289-04A (MOLEX) 62.6 62.6 62.6 61.5 61.5 61.5 -- - 721 721 721 OUTPUT CONNECTOR OUTPUT CONNECTOR 5273-04A OUTPUT CONNECTOR 5273-04A (MOLEX) 5273-04A (MOLEX) (MOLEX) 36 NC ACN ACN ACN 550.5 550.5 9 9 550.5 841 841 9 2.5 SEE NOTE A NAME NAME PLATE PLATE NAME PLATE === NOTES === A: M3 tapped holes (4) for customer chassis mounting. (Screws must not protrude into power supply by more than 5mm.) B: Model name and nominal output voltage and maximum output current are shown here in accordance with the specifications. C: Country of manufacturer will be shown here. D: C-UL-US & CE Marking (only 5V, 12V, 15V & 24V) E: ACCESSORIES : HOUSINGS 5199-04 (MOLEX) --- NET 1 5195-04 (MOLEX) --- NET 1 1.51.5 1.5 SEE NOTE B&C SEE NOTE B&C SEE NOTE B&C 12 12 SEE NOTE A A SEE NOTE 27.51 27.51 27.51 841 12 2.52.5 740.5 740.5 740.5 unit : mm TERMINALS 5194PBT (MOLEX) --- NET 7 All specifications are subject to change without notice. A-89 HK 25A/A, /C HK25A/A Screw terminals with cover 9.4 10.7 10.7 10.7 9.4 5M3 9.4 5M3 5M3 8.2 SEE NOTE A 36 36 ACL 13.5 4.5 4.5 10.5 4.5 11.3 11.3 4 10.5 700.5 11.3 4 991 991 991 4 880.5 880.5 880.5 SEE NOTE B SEE NOTE B NOTE B SEE === NOTES === 700.5 700.5 10.5 SEE SEENOTE NOTEBB SEE NOTE B 8 8 (Screws must not protrude into power supply by more than 5mm) B: 3.5 Holes (2) for customer chassis mounting. NAME PLATE NAME PLATE NAME PLATE 15 15 SEE NOTE C&D NOTE C&D SEESEE NOTE C&D (Use M3 mounting screws) C: Model name and nominal output voltage and maximum output cur- 8 SEE NOTE A SEE NOTE A NOTE A SEE A: M3 tapped holes (5) for customer chassis mounting. 15 HK-A 12.6 12.6 321 321 12.6 13.5 ACN ACN 13.5 ACN 721 721 721 9.5 62.9 61.5 SEE NOTE A SEE NOTE A 321 ACL TERMINAL COVER 62.9 FG 62.9 61.5 FG 36 TERMINAL COVER TERMINAL COVER 61.5 ACL COMPONENT SIDE 8.2 8.2 - - FG COMPONENT SIDE COMPONENT SIDE 9.5 - 9.5 rent are shown here in accordance with the specifications. D: Country of manufacturer will be shown here. 0.5 E: C-UL-US & CE Marking (only 5V,12V,15V & 24V) 0.5 0.5 830.5 830.5 70.570.5 830.5 70.5 unit : mm HK25A/C With connector and cover 9.4 10.7 9.4 - - 62.9 62.9 61.5 FG 61.5 61.5 62.9 - INPUT CONNECTOR INPUT CONNECTOR INPUT CONNECTOR 5289-04A 5289-04A 5289-04A (MOLEX) (MOLEX) (MOLEX) FG COMPONENT SIDE COMPONENT SIDE COMPONENT SIDE SEE NOTE A FG ACL NC NC ACN NC ACN ACN 10.5 10.5 4.5 10.5 4.5 SEE NOTE B SEE NOTE A ACL ACL 4 SEE NOTE A 721 721 OUTPUT CONNECTOR OUTPUT CONNECTOR OUTPUT CONNECTOR 5273-04A 5273-04A 5273-04A (MOLEX) (MOLEX) (MOLEX) 3636 10.7 721 9.4 36 10.7 4.5 700.5 700.5 700.5 991 4 SEE NOTE B SEE NOTE B 880.5 880.5 4 991 991 SEE NOTE B 880.5 SEE NOTE B SEE NOTE B C: Model name and nominal output voltage and maximum output current are shown here in accordance with the specifications. D: Country of manufacturer will be shown here. E: ACCESSORIES HOUSING 0.5 5199-04 (MOLEX) --- NET 1 5195-04 (MOLEX) --- NET 1 70.5 0.5 0.5 830.5 70.5 70.5 SEE NOTE C SEE NOTE D SEE NOTE C SEE NOTE D 830.5 830.5 8 8 SEE NOTE C SEE NOTE D (Use M3 mounting screws.) 15 B: 3.5 Holes (2) for customer chassis mounting. NAME PLATE NAME PLATE 15 NAME PLATE (Screws must not protrude into power supply by more than 5mm.) 15 A: M3 tapped holes (5) for customer chassis mounting. 321 8 SEE NOTE A 321 321 SEE NOTE A SEE NOTE A === NOTES === unit : mm TERMINALS 5194PBT (MOLEX) --- NET 7 F : C-UL-US & CE Marking (only 5V, 12V, 15V & 24V) A-90 All specifications are subject to change without notice. 12.2 9.4 5-M3 HK 50A/A, /C TERMINAL COVER HK50A/A TERMINAL COVER TERMINAL COVER 13.5 ACN ACN 721 - - N 9.5 SEE NOTE A SEE NOTE A 11.3 26 700.5 1191 13.5 9.5 ACL ACL 34 13.5 63.8 N 63 L FG SEE NOTE A COMPONENT SIDE COMPONENT SIDE L 8.2 9.5 FG 8.2 FG 63 COMPONENT SIDE - 72 1 72 1 - 5M35M3 FG 14.1 + 9.4 34 34 12.2 9.4 8.2 12.2 63.8 63 + Screw terminals with cover E PLATE (SCALE:2/1) === 14.1 11.3 SEE NOTE C A: M3 TAPPED HOLES(4) FOR CUSTOMER PUT:100-120VAC ~ 1.2 A CHASSIS MOUNTING. 50 / 60Hz UTPUT: 5 V 10 A SCREWS MUST NOT PROTRUDE INTO 26 11.3 70 0.5 70 0.5 119 1 119 1 26 HK-A 111.00.5 ( POWER SUPPLY BY MORE THAN 5mm. ) SEE NOTE B BAR CODE B: 3.5 HOLES(2) FOR CUSTOMER CHASSIS SEE NOTE A NAME PLATE MAXIMUM OUTPUT CURRENT ARE SHOWN SEE NOTE E HERE IN ACCORDANCE WITH THE SPECIFICATIONS. TE === D: COUNTRY OF MANUFACTURE WILL BE D HOLES(4) FOR CUSTOMER CHASSIS MOUNTING. SHOWN HERE. MUST NOT PROTRUDE INTO POWER SUPPLY E: C-UL-US & CE MARKING (ONLY 5V,12V,15V & E THAN 5mm. 24V) S(2) FOR CUSTOMER CHASSIS MOUNTING. SEE NOTE C,D&E 35.01 SEE NOTE B (USE M3 MOUNTING SCREWS) SEE NOTE D MADE IN C: CHINA MODEL NAME, NOMINAL OUTPUT VOLTAGE, 28.0 MOUNTING. 17.0 HK50A - 5 /A 14.1 === NOTE === 100.00.5 ( (unit : mm) 5.0 SEE NOTE B HK50A/C MOUNTING SCREWS) ME, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT With connector and cover OWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. OF MANUFACTURE WILL BE SHOWN HERE. 9.4 OUTPUT CONNECTOR 5273-04A OUTPUT CONNECTOR (MOLEX)5273-04A 63.8 63.8 INPUT CONNECTOR 5289-04A INPUT CONNECTOR (MOLEX) 5289-04A (MOLEX) FG 63.0 63.0 (MOLEX) ACL NC COMPONENT SIDE COMPONENT SIDE SEE NOTE A SEE NOTE A FG ACL 72 1 72 1 9.4 12.2 34 ACN NC 34 12.2 CE MARKING (ONLY 5V,12V,15V & 24V) ACN 70 0.5 26 26 70 0.5 119 1 119 1 111 SEE NOTE B SEE NOTE A A: M3 TAPPED HOLES(4) FOR CUSTOMER CHASSIS MOUNTING. 28 NAME PLATE (SCREWS MUST NOT PROTRUDE INTO POWER SUPPLY BY (USE M3 MOUNTING SCREWS) C: MODEL NAME, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUT- 17 MORE THAN 5mm.) B: 3.5 HOLES(2) FOR CUSTOMER CHASSIS MOUNTING. SEE NOTE C,D&E 100 (unit : mm) PUT CURRENT ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. D: COUNTRY OF MANUFACTURE WILL BE SHOWN HERE. 35 === NOTE === SEE NOTE B E: C-UL-US & CE MARKING (ONLY 5V,12V,15V & 24V) F: ACCESSORIES : HOUSINGS 5199-04 (MOLEX) --- NET 1 5195-04 (MOLEX) --- NET 1 TERMINALS 5194PBT (MOLEX) --- NET 7 All specifications are subject to change without notice. A-91 HK-A SERIES Block Diagram N Switching 85-132VAC 110-175VDC Rectifier & Filter Line Filter Inrush Current Limit Circuit Fuse L Rectifier & Filter HK10A, HK15A, HK25A - *1 Detector Control FG OCP HK-A OVP switching frequency *2 85132VAC 110175VDC N Rectifier & Filter Fuse Switching L Inrush Current Limit Circuit HK50A Rectifier & Filter Fuse rating HK10A, 15A4A HK25A3A *1 : HK10A and HK15A have no internal fuse. *2 : HK10A and HK15A adopt over voltage clamping by zener diode. (Full Load), 145kHz (No Load) (Full Load), 145kHz (No Load) (Full Load), 40kHz (No Load) Line Filter Circuit mode and Flyback topology HK10A500kHz HK15A600kHz HK25A200kHz - OCP Detector Control Switching FG OVP Circuit mode and switching frequency Single-ended forward topology 170kHzFixed Fuse rating 4A Rectifier & Filter N Switching 85-132VAC 110-175VDC Inrush Current Limit Circuit Fuse Line Filter H Rectifier & Filter HK100A, HK150A - S FG A-92 -S OVP Detector Circuit mode and switching frequency Single-ended forward topology 200kHzFixed Control Switching OCP Fuse rating HK100A5A HK150A6.3A All specifications are subject to change without notice. HK-A SERIES HK-A Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Ensure the wiring to input/output terminals is connected correctly according to this instruction manual. Do not turn the output voltage trimmer when not necessary. Output voltage is set to the rated value at shipping. Especially, when the volume in the power supply is set again, original characteristics of the power supply is not obtained. 1. Explanation on Front Panel HK10ASame as HK15A, HK25A, HK50A HK100A Same as HK150A Output Input Output Input +OUTPUT TERMINAL -OUTPUT TERMINAL FRAME GROUND TERMINAL INPUT TERMINAL(H) : Hot line with a fuse inside "H" a power supply. INPUT TERMINAL (N) "N": Neutral line without fuse. OUTPUT VOLTAGE INDICATOR (POWER ON) This indicator turns on when a power supply' s output is normal operating condition. OUTPUT ADJUST TRIMMER The out voltage rises when a trimmer is turned clockwise. REMOTE SENSING TERMINALS (+S, -S) These terminals are for remote sensing function which compensate the line drop (voltage drop by resistance of wire) between power supply terminals and load terminals. HK-A 2. Connection (Wiring) HK100ASame as HK150A Load When the remote sensing is not required, please short circuit the terminals of +S and + then -S and - with the attached sensing wires. Load HK10ASame as HK15A, HK25A, HK50A Ground Ground AC Input or DC Input No porality is designated in the case of DC Input. P lease do not connect 200VAC with input terminals in order to avoid damage of the power supply. Please do not turn V.ADJ trimmer except necessary. AC Input or DC Input No porality is designated in the case of DC Input. In the case of HK100A and/or HK150A, please connect remote sensing terminals to avoid working of OVP. Especially the V.ADJ trimmer inside the power supply is preset at the time of shipment. 3. Descriptions of Various Functions and Cautions 1 SETTING OF OUTPUT VOLTAGE RANGE The output voltage range can be set within the range of +/-10% of rated voltage by V.ADJ trimmer. The output All specifications are subject to change without notice. voltage rises when this trimmer is turned clockwise. However, please note that the over voltage protection may shut down a power supply, if the output voltage becomes excessively high. A-93 HK-A SERIES 2 Overload Protection (OCP) terminals to reduce the impedance. It should be noted that, The HK-A series are provided with built-in constant over during measurement, the ripple voltage cannot be mea- current protective circuit with automatic recovery. Hence, sured accurately. if the ground lead of the oscilloscope' s probe is too long the power supply will automatically recover when the overload condition is cleared. It is not externally adjustable. The short circuit and/or over current conditions continue over 30 seconds, the power supply may be damaged. 3 Over Voltage Protection (OVP) HK-A HK-A series is provided with a built in over voltage protection circuit. Once this over voltage protection circuit shuts down, the output can only be recovered by turning off the input line and reinput the power after the interval time. (HK10A, HK15A: Zener diode clamp method. When output voltage rises 115% < of nominal output voltage, OVP will operate and shut down the output. If this happens, zener diode must be changed.) 6 In-rush Current HK-A series is provided built-in in-rush current limiting circuit. Please select an input switch, fuse etc. carefully, when you use multiple power supplies in your system jointly. IN-RUSH CURRENTWAVE WAVECURVES CURVES IN-RUSH CURRENT IN-RUSH CURRENT WAVE CURVES (Input: 100VAC, Phase Angle: 90 , Full FullLoad, Load,Ambient Ambient 25) (Input: 100VAC, Phase Angle: 90 , ,Full Temperature: 25) (Input: 100VAC, Phase Angle: 90 Load, AmbientTemperature: Temperature: 25) HK10A HK10A HK10A 10A/Div 10A/Div 10A/Div 4 Remote Sensing This function is built only HK100A and HK150A models in. In the case of the line drop (voltage drop) caused by the resistance of wires between output terminals of power supply and the terminals of a load. If remote sensing is not required, please connect +S terminal with +terminal, and also connect -S terminal with -terminal. Remote sensing can compensate the line drop within the range of 10% of rated output voltage. Please use a shielded cable or twisted-pair cable for remote sensing. 5 Output Ripple Voltage The output ripple voltage is measured at the power supply output terminals, irrespective of whether a load is connected or not. If the load cable is long, connect a capacitor (electrolytic, film, etc.) of sufficient capacity to the load HK15A HK15A HK15A 10ms/Div 10ms/Div 10ms/Div HK25A HK25A HK25A 10A/Div 10A/Div 10A/Div 10A/Div 20ms/Div 20ms/Div 20ms/Div HK50A HK50A HK50A 20ms/Div 10A/Div 20ms/Div 10A/Div 20ms/Div 10A/Div HK100A 20ms/Div HK150A 10A/Div 20ms/Div 10A/Div 20ms/Div HK100A HK100A HK150A HK150A 10A/Div 10A/Div 10A/Div 20ms/Div 20ms/Div 20ms/Div 10A/Div 10A/Div 10A/Div 20ms/Div 20ms/Div 20ms/Div 4. Insulation Resistance And Withstand Voltage Test 1 Insulation Resistance Test Please use a DC megger (Max.500V) for measuring the insulation resistance between output terminals and chassis. The resistant figure of HK-A series is 100M ohm at 500VDC. 2 Withstand Voltage Test OUTPUT-CHASSIS Withstand voltage tester Isolation Tester 500VAC 1 minute100mA - Output FG H N A high voltage pulse may be generated when you change the charging DC value suddenly, therefore, please change the value gradually. After the test, please discharge a power supply by shortcircuiting all output terminals with chassis ground. Input 500VDC over 100M ohm This Series is designed to withstand 2.0kVAC, 1 minute between input and output terminals. Please set the LIMIT value of a withstand voltage tester at 20mA. The withstand voltage between output terminals and chassis is 500VAC, 1 minute (LIMIT current: 100mA). Please connect output as shown above. INPUT-FG A-94 All specifications are subject to change without notice. - Output Isolation Tester H 500VAC 1 minute100mA HK-A SERIES Input N 500VDC over 100M ohm Please connect OUTPUT as shown above. Please connect output as shown above. When you conduct the test, please elevate or lower the INPUT-FG applying voltage gradually. If you suddenly apply the high Input N 2.0kVAC 1 minute 20mA INPUT-CHASSIS voltage like 2.0kVA or shudown the applying voltage, many components of a power supply will be damaged and also it - is very dangerous for a test operator. - Output FG H Moreover, please do not use a timer in the test, because the high voltage impulse may be generated and break a power supply unit when a timer shutdown the input power. H Input N 2.0kVAC 1 minute 20mA Output FG N 2.0kVAC 1 minute 20mA Please connect OUTPUT as shown above. Input Please connect OUTPUT as shown above. INPUT-CHASSIS 5. Series & Parallel Operations Both (A) and (B) method is possible. In case of (A), please connect diodes to prevent the reverse voltage. (Refer to the below chart.) No parallel operation is possible. POWER SUPPLIES POWER SUPPLIES Output - POWER SUPPLIES SUPPLIES POWER FG Output Output Terminal Terminal H Output Output Terminal Terminal N 2.0kVAC 1 minute Load Load 20mA Output Output Terminal Terminal Load Load HK-A Input Output Terminal Terminal Output Please connect OUTPUT as shown above. Load Load A A B B 6. Installation Methods We recommend the standard installation method of (A). You can install a power supply like (B), (C) and (D). Please do not use (E), where the PCB will be on the top side and heat will be trapped inside the unit. PCB ASTANDARD B C DERATING TABLE BY INSTALLATION METHODS% HK10A B C D A B C D 30 100% 100% 100% 100% 100% 100% 100% 100% 40 100% 100% 100% 100% 100% 100% 100% 100% 50 100% 100% 50% 50% 100% 100% 50% 50% 60 50% 50% - - 50% 50% - - 70 - - - - - - - - A B C D A B C D 30 100% 100% 100% 100% 100% 100% 100% 100% 40 100% 100% 100% 100% 100% 100% 100% 100% 50 100% 70% 50% 50% 100% 70% 50% 50% 60 50% 40% - - 50% 40% - - 70 - - - - - - - - A B C D A B C D 30 100% 100% 100% 100% 100% 100% 100% 100% 40 100% 100% 100% 100% 100% 100% 100% 100% 50 100% 70% 50% 50% 100% 60% 40% 40% 60 50% 40% - - 50% - - - 70 - - - - - - - - D EDON'T USE Air flow HK15A A HK25A HK50A HK100A Sheet Metal More than 15mm Punch holes are necessary for ventilation. HK150A Notes: 1. Please keep less than 6m/m of screw into the power supply when mounting. Recommended torque is 5.0kg. cm. (Please use M4 screw for HK100A & HK150A, and the recommended torque is 13.0kg.cm.) 2. In the case of manner (3), please insert to U-cut the 1 2-M3 3 2-o3.5 2 2-M3 power supply and fix by screw. h h HK10A,15A,25A,50A ----1.2+0.2,-0mm HK100A,150A--------2.2+0.2,-0mm 4. External Fuse Rating 5. Before concluding that the unit is at fault... Refer to the following fuse rating when selecting the external fuses that are to be used on input line. Do not use fastblow fuse. Before concluding that the unit is at fault, make the following checks. 1Check if the rated input voltage is connected. 2Check if the wiring of input and output are correct. 3Check if output voltage, load regulation, and line regulation are measured with the output terminal. 4Check if the terminal screw is firmly tightened. 5Check if the wire material is not too thin. 6Please consult us when using the unit with a large capacitance (over 10,000F) of capacitors in the load side. Fuse Rating Model Fuse Rating HK10A 4A HK15A 4A HK25A 3A HK50A 4A HK100A 5A HK150A 6.3A All specifications are subject to change without notice. A-95 A-96