PLP-60 60W Single Output LED Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Built-in active PFC function Cooling by free air convection Output current level adjustable 100% full load burn-in test High reliability Suitable for built-in applications of LED lighting 2 years warranty SELV SPECIFICATION MODEL PLP-60-12 DC VOLTAGE 12V CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V OUTPUT PLP-60-48 24V 48V 18 ~ 24V 36 ~ 48V 1.3A RATED CURRENT 5A 2.5A CURRENT RANGE 0 ~ 5A 0 ~ 2.5A 0 ~ 1.3A RATED POWER 60W 60W 62.5W 4.5Vp-p 4.8Vp-p 1.875 ~ 2.5A 0.975 ~ 1.3A RIPPLE & NOISE (max.) Note.2 4.5Vp-p CURRENT ADJ. RANGE 3.75 ~ 5A VOLTAGE TOLERANCE Note.3 10% LINE REGULATION 3.0% 5.0% LOAD REGULATION 1000ms / 230VAC 2000ms / 115VAC at full load SETUP TIME VOLTAGE RANGE INPUT PLP-60-24 Note.4 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC EFFICIENCY(Typ.) 84% AC CURRENT INRUSH CURRENT(max.) 0.8A/115VAC 42A/230VAC LEAKAGE CURRENT <0.75mA / 240VAC OVER CURRENT Note.5 PROTECTION SHORT CIRCUIT OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 88% 89% 0.4A/230VAC 100 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed 15 ~ 18V 28 ~ 35V 57 ~ 63V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to output load derating curve) 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS TUV EN61347-1, EN61347-2-13 approved ; design refer to UL60950-1 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55015 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-3-2 Class C( 75% load); EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,EN61547, light industry level, criteria A 583.3Khrs min. MIL-HDBK-217F (25 ) 101.6*50.8*29.6mm (L*W*H) 0.16Kg; 96pcs/16.4Kg/0.89CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor, direct connecting to LED's is not suggested for models with "RIPPLE & NOISE" > 10% and using additional drivers is highly recommended. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 6. Heat sink HS1,HS2 can not be shorted. 7. Heat sink HS1 must have safety isolation distance with system case. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. File Name:PLP-60-SPEC 2010-09-06 http://store.iiic.cc/ PLP-60 60W Single Output LED Power Supply Mechanical Specification series Unit:mm 101.6 3.175 . 50.8 . 44.45 3.175 95.25 HS1 HS2 FS1 1 2 3 CN1 CN2 SVR1 1 2 4- 29.6 3.2 3max. 1.HS1,HS2 can not be shorted. 2.HS1 must have safety isolation distance with system case. AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/L No Pin AC/N DC Output Connector (CN2) : JST B2P-VH or equivalent Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1 2 Assignment +V -V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Block Diagram fosc : 90KHz(115VAC) 120KHz(230VAC) EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING FG +V -V DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.C.P. O.V.P. Derating Curve Static Characteristics Ta:25 100 100 Others 90 80 80 70 12V 50 LOAD (%) LOAD (%) 60 40 20 -30 -25 -5 0 20 40 50 55 60 70 (HORIZONTAL) 60 50 40 90 AMBIENT TEMPERATURE ( ) 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:PLP-60-SPEC 2010-09-06 http://store.iiic.cc/ PLP-60 60W Single Output LED Power Supply series Power Factor Characteristic Power factor will be higher than 0.9 when output loading is 75% or higher. PF Constant Current Mode 1 0 0 0 0 0 0 0 0 0 0 0 .0 .9 .9 .9 .9 .9 .8 .8 .8 .8 .8 .7 0 8 6 4 2 0 8 6 4 2 0 8 230V 110V 50% 60% 70% 80% 90% 100% LOAD EFFICIENCY vs LOAD (48V Model) EFFICIENCY (%) PLP-60 series possess superior working efficiency that up to 89% can be reached in field applications. 94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 230V 110V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)]. Vo(%) 100 (B) Constant Current area (A) Constant Voltage area 50 (max.) (C) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:PLP-60-SPEC 2010-09-06 http://store.iiic.cc/