DC/DC Converter
A_D-1WR2 series
2015.11.09-A/2 Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
See tolerance envelope graph (Fig. 1)
Input voltage change: ±1%
Short Circuit Protection**
Continuous, self-recovery
Note: * Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application Notes for specific operation;
**Supply voltage must be discontinued at the end of short circuit duration for A24xxD-1WR2 series, and A0524D-1WR2 model.
Input-output, with the test time of 1 minute and the leak
current lower than 1mA
Input-output, isolation voltage 500VDC
Input-output, 100KHz/0.1V
Derating when operating temperature up to 85℃, (see
Fig. 2)
Ta=25℃, nominal input, full load output
Pin Welding Resistance Temperature
Welding spot is 1.5mm away from the casing, 10 seconds
Full load, nominal input voltage
Black flame-retardant heat-proof plastic (UL94-V0)
CISPR22/EN55022 CLASS B (see Fig. 4 for recommended circuit)
CISPR22/EN55022 CLASS B (see Fig. 4 for recommended circuit)
IEC/EN61000-4-2 Contact ±6KV perf. Criteria B