cap04_reli-PRP2 cap04_reli_e-01
■ RELIABILITY DATA
Items Specifications Test Conditions, Remark
1. Operating Temperature range -30℃~+70℃
2. Max. Usable Voltage 2.6V
3. Resistance to Reflow
Soldering Heat
Capacity/Capacitance : Within initial spec.
Appearance : No noticeable abnormality
Conduct reflow soldering twice according to the reflow soldering test condition
mentioned below.
(Conduct the reflow in the condition of the voltage of 0.3V or lower.)
4. Floating Charge Characteristics Capacity/Capacitance : Over 70% of initial spec.
Appearance : No noticeable abnormality
Apply a max.usage voltage to the capacitor for 500 hours at max. operating
temp. and measure the floating charge characteristics after returning to normal
temperature and humidity.
5. Charge/Discharge
Cycle Characteristics
Capacity/Capacitance : Over 50% of initial spec.
Appearance : No noticeable abnormality
Measure the charge/discharge cycle characteristics after the 10000 cycles of
charge/discharge at 25±5℃ with the charge/discharge cycle test condition for
each part.
6. Thermal Durability Capacity/Capacitance : Over 80% of initial spec.
Appearance : No noticeable abnormality
Leave the capacitor in an atmosphere of 85℃±2℃ and -30±2℃ consecutively
for 96 hours each, and return to normal temperature and humidity.
7. Humidity Durability Capacity/Capacitance : Over 80% of initial spec.
Appearance : No noticeable abnormality
Temperature : 40±2℃, Humidity : 90~95%RH Leave the capacitor for under the
condition for 96hours then return to normal temperature and humidity.
8. Vibration Durability No exterior abnormality observed :
initial spec. values retained
Apply a sine wave vibration of 1.5mm amplitude at frequency 10~55Hz, for 2hours
per each direction (X,Y and Z) , for 6 hours in total.
◦Reflow Soldering Test Condition ◦Charge/Discharge Cycle Test Condition
Charging/Discharging
Resistance (Ω)300
Charging Voltage (V) 2.6
Charging Time (min.) 4.5
Discharging Time (min.) 0.5
Reflow profile with lead free condition
Cautions : Do not charge prior to reflow,
Set reflow condition within the range provided in "Specifications", which will
be published separately.
Consult with us about the details.
■ PRECAUTIONS
1. Use under the maximum usable voltage.
If over maximum usable voltage is applied, it might cause abnormal current flow
which shortens lifetime and sometimes damages PAS capacitor.
2. Use under surrounding temperature kept as normal as possible.
Lifetime of PAS capacitor is greatly affected by surrounding temperature. Each 10℃
drop in temperature extends its expected lifetime approximately twice as much.
Therefore, avoid high temperature and use PAS capacitor under lower temperature
than the maximum operating temperature range.
3. Mind voltage drop when back-up.
When the discharge starts, voltage drop occurs by actuating current and internal
resistance in the cell.
Consult us beforehand in case if discharging current of 311 type is over 10μA and
over 20μA for 409/414 type.
4. Consult us when using PAS capacitors in a series connection.
In case of using PAS capacitors in a series connection, the voltage may be differ-
ent in these capacitors, the difference of the voltages could shorten the lifetime of
the capacitors or break them down.
5. Pay sufficient attention to use PAS in circuit with high ripple current.
Since PAS capacitor has higher internal resistance than electric capacitor, ripple
current may heat up capacitor body, which might cause the increase of internal
resistance and deterioration of capacity.
6. Do not expose PAS capacitor into high humidity, alkaline or acid air.
In case PAS capacitor is used in high humidity, alkaline or acid air, lead terminal
and container may be damaged.
Also, it may cause deteriorating of its performance.
7. Do not touch with printed pattern.
If product touches printed pattern, short-circuit occurs.
Additionally, if there is a printed pattern under the product, it may occur short-
circuit caused by a breakage of resist.
8. Mind the polarity of PAS capacitor when soldering on board.
Identify the indication of polarity or terminal shapes when installing. Be sure that
PAS is installed as the indication of polarity or terminal shapes.
It may turn out to be a breakage of product.
9. Caution on soldering
◦ Follow the scope of conditions regulated in specifications.
◦ Do not charge prior to reflowing.
◦ Consult us for details about reflow condition.
10. Consult us about cleaning condition when cleaning circuit-board after soldering.
Cleaning may affect PAS capacitor. Consult us about cleaning conditions beforehand.
11. Avoid excessive vibration.
Excessive vibration may be a cause of breaking soldering part and damaging
terminal.
12. Storage
Keep following cautions for storage :
◦ Use our tray or reel. If you have to move the products from the tray or reel, be
sure not to bend terminals of them.
◦ Store under normal atmosphere. Sudden change of temperature or high humid
condition deteriorates the performance.
◦ Avoid dust and direct sunlight.
13. Other cautions
◦ Do not heat or throw into fire.
◦ Do not short-circuit.
◦ Do not solder directly to cell body.
◦ Do not dismantle.
◦ Do not deform.
◦ Mind the edge of terminals.
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.