Keysight Technologies AC6800 Series Basic AC Power Sources Data Sheet Because You Can't Afford Downtime Engineer reliability into your designs with a new basic AC source alternative from Keysight and test with conidence that your products will perform as designed... Maximize your uptime with the new Keysight Technologies, Inc. AC6800 Series basic AC power sources, and test your devices with conidence your products will perform as designed - even if voltage from the AC power grid is luctuating or you are facing extreme inrush current or transient spikes. Keysight's new AC6800 Series basic AC sources offer the quality and capability you need: - Intuitive user interface - If you've used a Keysight DC power supply, you'll feel right at home with these AC sources. - Flexible I/O - LAN/LXI Core and USB (standard), and GPIB (optional). And you can access and control the source remotely via a standard browser. - Low cost of ownership - backed with global support and the longest standard warranty in the industry Models up to 4000 VA are available to meet your basic AC source requirements. Models and Options Models AC6801A Basic AC power source, 500 VA, 270 V, 2.5 A AC6802A Basic AC power source, 1000 VA, 270 V, 5 A AC6803A Basic AC power source, 2000 VA, 270 V, 10 A AC6804A Basic AC power source, 4000 VA, 270 V, 20 A Options AC68ALGU Upgrade - user-installable analog interface board for AC6800 Series AC sources AC68GPBU Upgrade - user-installable GPIB interface board for AC6800 Series AC sources AC68RAC3 Rack mount lange kit for AC6801A, AC6802A, AC6803A AC68RAC6 Rack mount lange kit for AC6804A 03 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet A New Basic AC Power Source Alternative for Bench and Production-Line Testing Whether you want to manually control your basic AC source on your R&D bench or program it to use in a fully automated test rack, it must provide stable, dependable AC power to your DUT. You can use the AC6800 Series basic AC power sources for: - Simple tasks such as simulating global AC power conditions - Testing varying frequency and voltage combinations to simulate real-world conditions - Power factor correction testing and similar AC + DC applications (for example, test your input circuitry to look at ripple voltage) Choose from models up to 4000 VA, all with 0 to 270 Vrms and 40 to 500 Hz capability. AC6800 Series Basic AC Sources AC6801A AC6802A Phases Maximum output power AC6803A AC6804A Single-phase 500 VA 1000 VA 2000 VA 4000 VA AC output mode Voltage ranges (low/high range) Maximum rms current (low/high range) 135 Vrms/270 Vrms 5 A/2.5 A 10 A/5 A Frequency 20 A/10 A 40 A/20 A 40-500 Hz DC output mode Voltage ranges (low/high range) 190 V/380 V Maximum current (low/high range) 4 A/2 A 8 A/4 A 16 A/8 A 32 A/16 A Power capacity 400 W 800 W 1600 W 3200 W Measurements & I/O Measurements Transients Voltage, current, power, AC, DC and AC+DC Basic transient capability via optional analog card (Option: AC68ALGU) I/O Need higher-performance capabilities? If you need to generate and analyze more-sophisticated waveforms, harmonics or more complex transient signals, the Keysight 6800B Series AC power source/analyzers with built-in arbitrary waveform generator give you the ability to source and analyze more-complex AC applications up to 1750 VA. See www.keysight.com/ind/ACSources for more information. LAN/LXI Core with remote Web interface USB GPIB (Option: AC68GPBU) 04 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Easy Operation with an Intuitive, Time-Tested User Interface The AC6800's simple user interface allows you to easily access and view setup and measurement information directly from the front panel or programmatically. And you won't need to spend a lot of time learning to use the interface. If you've used an Keysight DC power supply, you'll feel right at home with the AC6800 Series basic sources. See basic voltage and current measurement information Set your display to show just the information you want Simply click through the metering options to modify the display to show your measurement priorities and increasing levels of details. The information displayed indicates both the setting levels and the selected output coupling mode or coniguration to allow you to control the AC source programmatically. See voltage, current and power measurement information Measurements may be AC coupled, DC coupled, or AC+DC coupled independent of the output coupling mode. Whether you use the front panel or control your AC source programmatically via SCPI (Standard Commands for Programmable Instruments), you can fully access all features. See full details of all measurement information available Flexible I/O to meet your needs Keysight AC6800 Series basic AC power sources come with LAN/LXI Core and USB interfaces (standard). For your legacy applications, an optional GPIB interface is also available that you can easily install yourself. Set up, monitor and operate your AC6800 sources remotely You can use the built-in Web server to remotely access and control your AC6800 Series AC sources via a standard browser. This control goes above and beyond the LXI Core speciication, giving you the ability to monitor and control the instrument from anywhere. Add more lexibility with an optional analog input board to add basic transient signals If you want to generate non-sinusoidal output waveforms or output transient events, use the optional analog input, which allows you to create analog waveforms using your function generator. See page 12 to learn more about the analog card's characteristics. The analog input option is also useful in situations where you want to control the output voltage level with an external DC control signal. 05 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Low Cost of Ownership - Backed with Global Support and the Industry's Longest Standard Warranty In manufacturing test applications, the upfront cost of your power supplies is just one factor in the total cost of test. Keysight's new AC6800 Series sets a new standard for reliability, so you can expect the lowest overall cost of ownership. You can: - Increase your conidence in your AC source uptime. With the industry's longest standard warranty for an AC power source, you'll see a lower total cost of ownership and fewer budgetary surprises. - Take advantage of Keysight's network of global service and support centers. You can easily move AC6800 Series sources between global locations. If you ever need a repair, Keysight's global support network offers the convenience of nearby support. - Easily document calibration. Each AC6800 Series AC source ships with a printed copy of the commercial calibration certiicate along with all the test data obtained from the calibration cycle. Example applications where AC6800 basic AC sources are ideal - Manufacturing test for power adapters for battery-powered devices For AC adapters for mobile and consumer products (mobile phones, computers, tablets, etc.), you need basic AC sources to vary frequency and voltage during manufacturing test to represent different worldwide power conditions. If you need robust inrush surge current capability for panel testing, the AC6800 basic AC sources are ideal. - Avionics - Testing cabin electronic devices If you need to simulate single-phase 400 Hz power for powering cabin electronics like lighting and stereo systems during development, manufacturing test or repair, the reliable, AC6800 basic AC sources are a great solution. - European and Asian lighting applications If you are manufacturing ballasts for LEDs or luorescent lights that range from 1 kVA to 3 kVA and up to 270 Vrms you can count on the AC6800 basic AC sources for reliable power. Use them to vary the input voltage and measure the output voltage, current and power at different frequencies to make sure the voltage is within your speciied range. 06 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Deinitions Speciications Unless otherwise noted, speciications are warranted over the ambient temperature range of 0 to 40 C after a 30-minute warm-up period. Speciications apply at the output terminals. Accuracy speciications are warranted for three years. Supplemental characteristics/typical values Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by type testing. All supplemental characteristics are typical unless otherwise noted. Speciications Model AC6801A AC6802A AC6803A AC6804A Output ratings for AC mode (135 V/270 V range) Rated voltage range 1 to 135 Vrms/2 to 270 Vrms Voltage setting accuracy 1 0.3% of full scale/0.25% of full scale Output phases Maximum rms current Single 2 5 A/2.5 A 10 A/2.5 A Load power factor capability 20 A/10 A 40 A/20 A 0 to 1 (leading or lagging) Maximum power 500 VA 1 kVA 2 kVA Frequency setting range 4 kVA 40 to 500 Hz Frequency accuracy 0.02% Output ratings for DC mode (135 V/270 V range) Rated voltage range 1.4 to 190 V/2.8 to 380 V Voltage setting accuracy 3 0.3% of full scale/0.25% of full scale Maximum rms current 4 4 A/2 A 8 A/4 A 16 A/8 A 32 A/16 A Maximum power 400 W 800 W 1600 W 3200 W 1. 2. 3. 4. For an output voltage of 13.5 to 135 V/27 to 270 V, an output frequency of 45 Hz to 65 Hz, no load, and 23 5 C For an output voltage of 1 to 100 V/2 to 200 V. Limited by the output power when the output voltage is 100 to 135 V/200 to 270 V For an output voltage of 19 to 190 V/38 to 380 V, no load, and 23 5 C For an output voltage of 1.4 to 100 V/2.8 to 200 V. Limited by the output power when the output voltage is 100 to 190 V/200 to 380 V 270 380 High voltage range High voltage range Low voltage range Low voltage range 200 Voltage (Vrms) 135 Voltage 200 (Vdc) 190 100 100 AC6801A (500 VA): AC6802A (1000 VA): AC6803A (2000 VA): AC6804A (4000 VA): 1.85 3.70 7.40 14.80 2.5 5.0 10.0 20.0 3.7 7.4 14.8 29.6 Current (Arms) AC6800 steady-state AC output characteristic 5 10 20 40 AC6801A (400 W): AC6802A (800 W): AC6803A (1600 W): AC6804A (3200 W): 1.05 2.10 4.20 8.40 2 2.1 4 4.2 8 8.4 16 16.8 Current (Adc) AC6800 steady-state DC output characteristic 4 8 16 32 07 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Speciications continued Model AC6801A AC6802A AC6803A AC6804A Output voltage stability (135 V/270 V range) Load regulation 1 For 40 to 100 Hz: 0.15 V/0.3 V For other frequencies: 0.5 V/1 V Measurements 2,3 (135 V/270 V range) Voltage accuracy 4 RMS, AC, DC Current accuracy 5,6 RMS, AC, DC For 45 to 65 Hz and DC: (0.5% of reading + 0.02 A/0.01 A) Typical: (0.25% of reading + 0.02 A/0.01 A) For all other frequencies: (0.7% of reading + 0.04 A/0.02 A) For 45 to 65 Hz and DC: (0.5% of reading + 0.04 A/0.02 A) Typical: (0.25% of reading + 0.04 A/0.02 A) For all other frequencies: (0.7% of reading + 0.08 A/0.04 A) For 45 to 65 Hz and DC: (0.5% of reading + 0.08 A/0.04 A) Typical: (0.25% of reading + 0.08 A/0.04 A) For all other frequencies: (0.7% of reading + 0.16 A/0.08 A) For 45 to 65 Hz and DC: (0.5% of reading + 0.16 A/0.08 A) Typical: (0.25% of reading + 0.16 A/0.08 A) For all other frequencies: (0.7% of reading + 0.32 A/0.16 A) AC power accuracy (45-65 Hz) 7 WAC (2% of reading + 0.5 W) Typical: (1% of reading + 0.5 W) (2% of reading + 1 W) Typical: (1% of reading + 1 W) (2% of reading + 2 W) Typical: (1% of reading + 2 W) (2% of reading + 4 W) Typical: (1% of reading + 4 W) (2% of reading + 0.5 W + 0.02 W/0.01 W per VDC) Typical: (1% of reading + 0.5 W + 0.01 W/0.005 W per VDC) (2% of reading + 1 W + 0.04 W/0.02 W per VDC) Typical: (1% of reading + 1 W + 0.02 W/0.01 W per VDC) (2% of reading + 2 W + 0.08 W/0.04 W per VDC) Typical: (1% of reading + 2 W + 0.04 W/0.02 W per VDC) (2% of reading + 4 W + 0.16 W/0.08 W per VDC) Typical: (1% of reading + 4 W + 0.08 W/0.04 W per VDC) DC power accuracy 7 WDC For 45 to 65 Hz and DC: (0.5% of reading + 0.3 V/0.6 V) Typical: (0.25% of reading + 0.15 V/0.3 V) For all other frequencies: (0.7% of reading + 0.9 V/1.8 V) 1. For an output voltage of 80 to 135 V/160 to 270 V, a load power factor of 1, a step change in output current from 0 A to maximum rms current (or its reverse) using the output terminal on the rear panel 2. RMS, AC, DC, and power (W) are derived using the following equations: N1 (instantaneous voltage or current) a. RMS = b. DC = c. AC = RMS2 - DC2 d. W TOTAL = e. WDC = V DC x IDC 2 1 (instantaneous voltage or current) N 1 (instantaneous voltage x instantaneous current) N f. WAC = W TOTAL - WDC 3. Further measurement information: a. Sample window: 100ms to 125 ms for AC or AC+DC output coupling (an integer multiple of the output waveform period), 125 ms for DC output b. Update interval: Approximately 3 times/sec, averaging up to 16 intervals when averaging is turned on c. Peak current value returns the maximum of the absolute values of the instantaneous current samples in a single measurement interval (averaging off) d. The meter display is set to "RMS" in AC+DC meter coupling, "AC" in AC meter coupling, and "DC" in DC meter coupling 4. AC mode: For an output voltage of 13.5 to 135 V/27 to 270 V and 23 5 C DC mode: For an output voltage of 19 to 190 V/38 to 380 V and 23 5 C 5. For a waveform of crest factor 3 or less, an output current in the range of 5 to 100% of the maximum rms current, and 23 5 C 6. Peak current measurement accuracy information available in "Supplemental Characteristics" section 7. For an output voltage of 50 V or greater, an output current in the range of 10 to 100% of the maximum rms current, DC or an output frequency of 45 to 65 Hz, a load power factor of 1, and 23 5 C 08 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Supplemental Characteristics Model AC6801A AC6802A AC6803A AC6804A Input rating Nominal input rating 100 to 120 Vrms/200 to 240 Vrms, 50 Hz or 60 Hz, single-phase Input voltage range 90 to 132 Vrms/180 to 264 Vrms (auto detected when the power is turned on) Input frequency range 47 Hz to 63 Hz Apparent power Power factor 800 VA or less 1600 VA or less 3200 VA or less 8 A/4 A or less (@100 V/200 V) 16 A/8 A or less (@100 V/200 V) 32 A/16 A or less (@100 V/200 V) 64 A/32 A or less (@100 V/200 V) 6.7 A/3.5 A or less (@120 V/230 V) 13.4 A/7.0 A or less (@120 V/230 V) 26.8 A/14.0 A or less (@120 V/230 V) 53.6 A/28.0 A or less (@120 V/230 V) 1 6400 VA or less 0.9 (typical) Input current Output ratings for AC mode (135 V/270 V range) Programmable voltage range 0 to 137.5 Vrms/0 to 275 Vrms Voltage setting resolution 0.1 V Frequency setting resolution 0.1 Hz Voltage THD 2 0.5% or less Eficiency 3 70% or greater Maximum repetitive peak current 4 15 A/7.5 A 30 A/15 A 60 A/30 A 120 A/60 A Output ratings for DC mode (135 V/270 V range) Programmable voltage range -194.5 to 194.5 V/-389 to 389 V Voltage setting resolution 0.1 V Maximum repetitive peak current Ripple noise 4 12 A/6 A 5 24 A/12 A 48 A/24 A 96 A/48 A 0.7 Vrms/1.4 Vrms (typical) Output voltage stability Temperature coeficient 6 Output voltage response time 100 ppm/C (typical) 7 150 us (typical) Line regulation 8 0.15% of full scale Measurements (135 V/270 V range) Voltage measurement resolution 0.1 V Current measurement resolution 0.01 A Peak current measurement accuracy 9 Power measurement resolution 1. 2. 3. 4. 5. 6. 7. (2% of reading + 0.1 A/0.05 A) (typical) (2% of reading + 0.2 A/0.1 A) (typical) (2% of reading + 0.4 A/0.2 A) (typical) (2% of reading + 0.8 A/0.4 A) (typical) 0.1 W, 1 W (for 1000 W or more) For an output voltage of 100 V/200 V (135 V/270 V range), maximum rms current, and a load power factor of 1 At an output voltage of 50 to 135 V/100 to 270 V, a load power factor of 1, and in AC mode For AC mode, at an output voltage of 100 V/200 V, maximum rms current, load power factor of 1, and an output frequency of 40 to 500Hz For a periodic, pulsed current waveform with the total rms current under the speciied maximum rms current For 5 Hz to 1 MHz components measured at the output terminals on the rear panel For an output voltage of 100 V/200 V, an output current of 0 A, and within the operating temperature range For DC mode, an output voltage of 100 V/200 V, a load power factor of 1, and settling within a band of 1% about nominal, under a step change in output current from 0A to the maximum rms current (or its reverse) 8. For line voltage and frequency changes within the rated range 9. For a waveform of crest factor 3 or less, an output current in the range of 5 to 100% of the Maximum repetitive peak current, and 23 5 C 09 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Supplemental Characteristics continued Model AC6801A AC6802A AC6803A AC6804A Common Isolation to ground 270 Vrms or 380 VDC Insulation resistance (Between input and chassis, output and chassis, input and output) 500 Vdc, 30 M or more Withstand voltage (Between input and chassis, output and chassis, input and output) 1.5 kV AC for 1 minute 25 A AC, 0.1 or less Earth continuity Electromagnetic compatibility (EMC) Safety 1 Complies with the requirements of the following directive and standards EMC Directive 2004/108/EC EN 61326-1 Under following conditions: The maximum length of all connecting cables and wires to the unit is less than 3 m. Complies with the requirements of the following directive and standards Low Voltage Directive 2006/95/EC EN 61010-1 Class I Pollution Degree 2 Environment Operating environment Indoor use, Overvoltage Category II Operating temperature and humidity range 0 to 40 C (32 to 104 F), 20% to 80% R.H. non-condensing Storage temperature and humidity range -10 to 60 C (14 to 140 F), 90% or less R.H. non-condensing Altitude Up to 2000 m Acoustic noise < 70 dbA Physical Dimensions (Depth includes Barrier Block Safety Cover) 428 x 128 x 370 mm 16.9 x 5.0 x 14.6" 428 x 128 x 370 mm 16.9 x 5.0 x 14.6" 428 x 128 x 581 mm 16.9 x 5.0 x 22.9" 428 x 262 x 611 mm 16.9 x 10.3 x 24" Weight Approx. 8 kg (17.64 lb) Approx. 11 kg (24.25 lb) Approx. 15 kg (33.07 lb) Approx. 31 kg (68.34 lb) Input terminal IEC 320 inlet M4 terminal block M6 terminal block M6 terminal block Output terminal M4 terminal block M4 terminal block M4 terminal block M6 terminal block LAN interface Hardware IEEE 802.3 100Base-TX or 10Base-T Ethernet Complies with LXI Speciication version 1.4 Class C IPv4, RJ-45 connector2 Communication protocol VXI-11, HiSLIP, or SCPI-RAW Program message terminator VXI-11 and HISLIP: LF or END during reception, LF + END during transmission SCPI-RAW: LF during reception, LF during transmission USB interface Hardware Complies with USB 2.0; Data rate: 12 Mbps (full speed) Program message terminator LF or EOM during reception, LF + EOM during transmission Device class Complies with the USBTMC-USB488 device class speciications GPIB interface (Option AC68GPBU) Hardware Complies with IEEE Std 488.1-1978 SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E1 Program message terminator LF or EOI during reception, LF + EOI during transmission Primary address 1 to 30 1. Only on models that have CE marking on the panel. AC68xx models will not be in compliance with EMC limits unless the ferrite core is attached on the load wires 10 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Supplemental Characteristics continued Model AC6801A AC6802A AC6803A AC6804A Common interface speciications Software protocol IEEE Std 488.2-1992 Command language SCPI Speciication 1999.0 Save/recall states Save and recall up to ten instrument states in non-volatile memory Accessories included 1 standard power cord 1 Length: Approx. 2.5 m Power cord Not included Not included Ferrite core 1 Cable tie 1 Not included Analog programming interface (Option AC68ALGU) Input Maximum voltage 15 V Connector BNC Impedance 10 k 5% (unbalanced) Isolation voltage 100 Vmax EXT-AC mode 2 Input voltage range EXT-DC mode 0 V to +10 V (DC) Voltage ampliication ratio (135 V/270 V range) 13.5x/27x (Outputs an AC voltage of 0 V to 135 V/0 V to 270 V with respect to a DC voltage input of 0 V to 10 V) Frequency setting range 40 Hz to 500 Hz Other output rating speciications Same as the speciications of the output rating for AC mode Input voltage range When ATT is OFF 0 V to 1.91 Vpeak (0 V to 1.35 Vrms sine wave) When ATT is ON 0 V to 10 V (DC) Input frequency range When ATT is OFF 3 40 to 500 Hz (sine wave)/40 to 100 Hz (rectangular wave)/DC Frequency response When ATT is OFF -0.3 dB at 500 Hz with respect to 55 Hz (typical) Voltage ampliication ratio (135 V/ 270 V range) When ATT is OFF 100x/200x (Outputs an AC voltage of 0 to 135 V/0 to 270 V with respect to a AC voltage input of 0 to 1.35 V) When ATT is ON 19x/38x (Outputs a DC voltage of 0 to 190 V/0 to 380 V with respect to a DC voltage input of 0 to 10 V) Other output rating speciications Same as the speciications of the output rating for DC mode Output voltage distortion ratio 4 Main speciications + 0.5% or less Output voltage temperature coeficient Main speciications + 200 ppm/C (typical) Insulation resistance Between input (BNC) and chassis, input (BNC) and output 500 V DC, 30 M or more Withstand voltage Between input (BNC) and chassis, input (BNC) and output 500 V AC for 1 minute 1. Based on country of use; power cords for Continental Europe, United States/Canada or China included. For other countries, applicable power cord can be selected 2. Set ATT to `ON' in EXT-AC mode at all times 3. The measurable range of voltage, current, and power is DC and 40 to 500 Hz. To improve measurement stability of an AC output, set the frequency to match the frequency of the external input signal 4. When DC voltage is applied for EXT-AC mode or when a sine wave with distortion ratio of 0.1% or less is applied for EXT-DC mode 11 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Just the Capability You Need AC6801/2/3A Front Panel AC6801/2/3A Front Panel Status LEDs 64x256 Dot matrix display Mains switch Navigation keys Settings keys Numeric entry keys System keys AC6801A Rear Panel USB and LAN/LXI Core standard Output terminal block Slot for optional GPIB (AC68GPBU) or Analog interface card (AC68ALGU) AC6802A Rear Panel AC6802A Rear Panel USB and LAN/LXI Core standard AC power input Based on country of use; power cords for Continental Europe, United States/Canada or China included for AC6801A. For other countries, applicable power cord can be selected. Output terminal block AC power input. Power cord not included for AC6802A Slot for optional GPIB (AC68GPBU) or Analog interface card (AC68ALGU) AC6803A Rear Panel AC6803A Rear Panel USB and LAN/LXI Core standard Output terminal block AC power input. Power cord not included for AC6803A Slot for optional GPIB (AC68GPBU) or Analog interface card (AC68ALGU) 12 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Just the Capability You Need AC6804A Front Panel Status LEDs Mains switch 64x256 Dot matrix display Navigation keys Settings keys System keys Numeric entry keys AC6804A RearRear Panel AC6804A Panel USB and LAN/LXI Core standard Output terminal block AC power input. Power cord not included for AC6804A Slot for optional GPIB (AC68GPBU) or Analog interface card (AC68ALGU) 13 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Supplemental Characteristics continued Model AC6801A Model AC6801A 429 143 128 Air direction 370 346 240 55 Model AC6802A Model AC6802A 429 143 128 Air direction 370 346 240 55 All dimensions in millimeters 14 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet Supplemental Characteristics continued Model AC6803A 429 143 128 Air direction 581 470 340 445 55 Model ModelAC6804A AC6804A 429 282 262 L N G L N 380 Air direction 544 611 515 All dimensions in millimeters 415 55 15 | Keysight | AC6800 Series Basic AC Power Sources - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA(R) Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA(R), AdvancedTCA(R), and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight's commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight's measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/AC6800 For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Paciic Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-14) This information is subject to change without notice. (c) Keysight Technologies, 2014 Published in USA, December 19, 2014 5991-4194EN www.keysight.com