DENSEI-LAMBD
PFE500F
SPECIFICATIONS
C250-01-01
MODEL
ITEMS
1 Nominal Output Voltage (*1) V 12 28 48
2 Maximum Output Current A 42 18 10.5
3 Nominal Output Power W 504 504 504
4 Efficiency (Typ.) (*1) % 81 / 83 84 / 86 84 / 86
5 Input Voltage Range (*2) (*5) - 85 - 265 VAC
6 Input Frequency (*2) Hz 47 - 63
7 Input Current (*1) A 6.8 / 3.4 6.4 / 3.2 6.4 / 3.2
8 Power Factor (*1)(*5) - 0.95 min
9 Output Voltage Accuracy % +/-2
10 Output Voltage Range % -20 / +20
11 Maximum Ripple & Noise (*5) mV 120 280 480
12 Maximum Line Regulation mV 48 56 96
13 Maximum Load Regulation mV 48 56 96
14 Over Current Protection - 105% - 140% (Automatic recovery method)
15 Over Voltage Protection (*8) - 125% - 145% (Inverter shutdown method)
16 In-rush Current (Typ.) (*1)(*5) A 20A / 40A peak
17 Remote Sensing (*6) - Possible
18 Remote ON/OFF Control (*6) - Possible
19 Parallel Operation (*6) - Possible
20 Series Operation (*6) - Possible
21 Operating Temperature (*3)(*7) - -40°C - +85°C(Baseplate) -40°C - +100°C(Baseplate)
22 Operating Humidity - 20 - 95%RH (No Dewdrop)
23 Storage Temperature - -40°C - +100°C
24 Storage Humidity - 10 - 95%RH (No Dewdrop)
25 Cooling (*4) - Conduction Cooled
26 Withstand Voltage - Input-Baseplate : 2.5kVAC, Input-Output : 3.0kVAC for 1min.
Output-Baseplate : 500VDC for 1min.
27 Isolation Resistance - Output-Baseplate 500VDC more than 100MΩ (25°C,70%RH)
28 Vibration - At no operating, 10-55Hz (Sweep for 1min.)
Amplitude 0.825mm constant (Maximum 49.0m/s2) X,Y,Z 1 hour each
29 Shock - 196.1m/s2
30 Weight (Typ.) g 300
31 Size (W x H x D) mm 70 x 12.7 x 122 (Refer to Outline Drawing)
Derating Curve
=NOTES=
*1. At 100VAC/200VAC and maximum output power.
(Baseplate Temperature = +25°C.)
*2. For cases where conformance to various safety specs
(UL, CSA, EN) are required, input voltage range
will be 100 - 240VAC(50/60Hz).
*3. Ratings - refer to Derating Curve on the right.
*4. Heatsink has to be chosen according to Instruction manual.
*5. External components are needed for operation.
(Refer to basic connection and instruction manual.)
*6. Refer to Instruction manual.
*7. Ambient Temperature min=-40°C
*8. OVP reset : Line off or Control off.
(Refer to instruction manual.)
PFE500F-12 PFE500F-28 PFE500F-48
0
20
40
60
80
100
-40 -20 0 20 40 60 80 100
Baseplate Temperature (°C)
Load (%)
PFE500F-12
PFE500F-28, 48
85