Heavy Duty Pressure Transducers PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi 50069942 Datasheet Issue I Datasheet FEATURES * Pressure range: 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi * Pressure reference: Absolute, sealed gage or vented gage * Pressure port types: 7/16-20 UNF 1/4 in 45 Flare Female Schrader (SAE J512), 7/16-20 UNF 45 Flare Male (SAE J513), 7/16-20 UNF 37 Flare Male (SAE J514), G1/4 (ISO 1179-3), G1/8 (ISO 1179-3), M12 x 1.5 (ISO 6149-3), 1/4-18 NPT, 1/8-27 NPT, 9/16-18 UNF, (SAE J1926-3), or 7/16-20 UNF (SAE J1926-3) * Electrical connector types: Metri-Pack 150 (UL 94 HB or V-0 options), Micro M12, DIN, Deutsch, or cable harness DESCRIPTION Honeywell's PX2 Series Heavy Duty Pressure Transducers are a portfolio of configurable pressure sensors that use piezoresistive sensing technology with ASIC (Application Specific Integrated Circuit) signal conditioning in a stainless steel housing. The PX2 Series is fully calibrated and compensated for offset, sensitivity, temperature effects and non-linearity using the on-board ASIC. These transducers measure absolute, sealed gage, or vented gage pressure. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure, sealed gage versions have an internal pressure reference of one atmosphere at sea level, and vented gage versions measure pressure with respect to ambient pressure. They are RoHS compliant and are designed and manufactured according to ISO 9001 standards. VALUE TO CUSTOMERS * Media compatibility: Common HFC (hydrofluorocarbon) (1 m, 2 m, 3 m, or 5 m) * Total Error Band: 2.0 % * Operating and compensated temperature range: -40C to 125C [-40F to 257F] * Response time: <2 ms * Life: Minimum of 10 million cycles to operating pressure * Output transfer function: Ratiometric, regulated or current * Mechanical shock rating: 100 G per MIL-STD-202F, Method 213B, Cond. F * Vibration rating: 20 G sweep, 10 Hz to 2000 Hz * Ingress protection: Up to IP69K * Radiated immunity protection: Up to 100 V/m (ISO 11452-2) * Flame retardant options: UL 94 HB standard on all electrical terminations; UL 94 V-0 available upon request POTENTIAL APPLICATIONS * Industrial: Refrigerant pressure monitoring in HVAC/R systems; air compressor system pressure * Transportation: Air system monitoring; hydraulic oil pressure monitoring refrigerants such as R410A and R134A, next generation low global warming potential (GWP) refrigerants such as R448A The PX2 Series is not recommended for use with media (Solstice(R) N40), R32 and R1234ZE, engine oil, petroleum- involving water, saturated air such as steam and vapor, and based hydraulic fluids, DOT 3 brake fluid, and dry air. For ammonia. ammonia and other corrosive media, see Honeywell's SPT Series. * Enhanced durability: The PX2 Series can operate in the rigorous environments commonly found in HVAC/R and air compressor applications. The sensor can survive at least 10 million pressure cycles and has an ingress protection rating up to IP69K. Sensing and Internet of Things PORTFOLIO Honeywell's PX2 Series joins the PX3 Series, MLH Series, and SPT Series heavy duty pressure transducers. Heavy Duty Pressure Transducers PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi Table 1. Performance Specifications1 Characteristic Parameter Operating temperature range Storage temperature range -40C to 125C [-40F to 257F] 2 -40C to 125C [-40F to 257F] 3 Compensated temperature range 4 Overpressure minimum rating -40C to 125C [-40F to 257F] (See Table 3.) 5 Burst pressure minimum rating6 (See Table 3.) Long term stability 0.5 %FSS (1000 hr at 25C [77F]) 9 Accuracy 0.25 %FSS9 (See Figure 1.) 7 Offset error 1 %FSS9 8 Total Error Band10 2 %FSS9 (-40C to 125C [-40F to 257F]) (See Figure 1.) Response time11 <2 ms Turn on time <7 ms Life 12 minimum of 10 million cycles to operating pressure 13 All specifications apply at 25C and under operating conditions unless otherwise noted. 2 Operating Temperature Range: The temperature range over which the product will produce an output proportional to pressure but may not remain within the specified performance limits. 3 Storage Temperature Range: The temperature range over which the product may safely be exposed without excitation or pressure applied. Under these conditions the product will remain in specification after excursion to any temperatures within this range. Exposure to temperatures outside this range may cause permanent damage to the product. 4 Compensated Temperature Range: The temperature range (or ranges) over which the product will produce an output proportional to pressure within the specified performance limits. 5 Overpressure: The absolute maximum rating for pressure which may be safely applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressure may cause permanent damage to the product. 6 Burst Pressure: The maximum pressure that may be applied to the product without causing escape of the pressure media. The product should not be expected to function after exposure to any pressure beyond the rated burst pressure. This rating is also the case burst rating of the product. 7 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25C. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 8 Offset Error: the maximum deviation in the output signal obtained when the reference pressure is applied at 25C relative to the ideal transfer function. 9 Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range. 10 Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis. 11 Response Time: The response time of the transducer is the maximum amount of time that the transducer will take for the transducer to output a change from 10% to 90% of full scale in response to a 0% to 100% full scale step input pressure range. 12 Turn On Time: Duration from power applied until first valid output. 13 Life may vary depending on the application in which transducer is used. 1 Figure 1. Total Error Band (TEB) for the Total Error Band Series All Possible Errors Offset Full Scale Span Pressure Non-Linearity Pressure Hysteresis Pressure Non-Repeatability Thermal Effect on Offset Thermal Effect on Span Thermal Hysteresis 2 Sensing and Internet of Things Accuracy BFSL Total Error Band Heavy Duty Pressure Transducers PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi Table 2. Electrical Specifications Current Output Ratiometric Output Characteristic Regulated Output Output Transfer Function Order Code1 AA AB AC AD CH BC BD BE BG 4 mA 4 mA 16 mA 8V -- 30 V4 1V 6V 5V 9V -- 30 V 3 0.25 V 10.25 V 10 V 13 V -- 30 V 3 0.5 V 4.5 V 4V 8V -- 30 V 3 1V 5V 4V 8V -- 30 V3 1 Output transfer function : null output value full scale output value full scale span (FSS) operating supply voltage, min.(Vs)2 operating supply voltage, typ. (Vs)2 operating supply voltage, max. (Vs)2 10% of Vs 5% of Vs 10% of Vs 5% of Vs 90% of Vs 95% of Vs 90% of Vs 95% of Vs 80% of Vs 90% of Vs 80% of Vs 90% of Vs 3.135 V 3.135 V 4.5 V 4.75 V 3.3 V 3.3 V 5V 5V 3.465 V 3.465 V 5.5 V 5.25 V Supply current (typ.) Output load (pull up or down): minimum maximum Absolute voltage ratings5: minimum6 maximum6 maximum applied to output pin (short circuit protection)7 EMC rating8: CE compliance: electrostatic discharge radiated immunity fast transient burst immunity to conducted disturbances radiated emissions ISO 11452-2 radiated immunity 1 2 3 4 5 6 7 8 5 mA 4 mA -- 5.5 mA 2 kOhm -- -- (Vs - 8) x 50 Ohm4 2 kOhm -- -16 V 16 V Vs -16 V 30 V -- -16 V 30 V 12 V 4 kV contact, 8 kV air per IEC 61000-4-2 10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3 1 kV per IEC61000-4-4 3 V per IEC61000-4-6 40 dB 30 MHz to 230 MHz; 47 dB 230 MHz to 1000 MHz per CISPR 11 100 V/m 200 MHz to 2 GHz 20 V/m 200 MHz to 2 GHz Output transfer function options are shown in the Nomenclature and Order Guide. (See Figure 4.) Transducer will not produce valid output when supply voltage is outside of operating range. Applies at 25C. See Figure 2 for Regulated Output Supply Voltage. Applies at 25C. See Figure 3 for Current Output Supply Voltage. Absolute maximum ratings are the extreme limits the device can withstand without damage to the product. Voltages above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. Absolute voltage applies to potential across power and ground terminals. Short circuit protection between output pin and ground, and output pin and supply pin. All EMC ratings verified with the Metri-Pack 150 electrical connector type. Figure 2. Regulated Output Supply Voltage Figure 3. Current Output Supply Voltage Sensing and Internet of Things 3 Heavy Duty Pressure Transducers PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi Table 3. Pressure Ratings bar kPa MPa psi Operating OverBurst Operating OverBurst Operating OverBurst Operating OverBurst Pressure pressure Pressure Pressure pressure Pressure Pressure pressure Pressure Pressure pressure Pressure 1 5 8 100 500 800 1 3.1 5.1 15 70 115 1.6 5 8 160 1000 1700 1.6 5.2 8.6 30 150 250 2 10 17 250 1000 1700 2.5 6.9 10.3 50 250 400 2.5 10 17 400 1700 2700 4 6.9 10.3 100 450 750 4 17 27 600 3100 5100 4.6 6.9 10.3 150 450 750 6 31 51 -- -- -- 6 13.8 20.6 200 750 1250 8 31 51 -- -- -- 7 13.8 20.6 250 750 1250 10 31 51 -- -- -- -- -- -- 300 1000 1500 16 52 86 -- -- -- -- -- -- 500 1000 1500 25 69 103 -- -- -- -- -- -- 600 1000 1500 34 69 103 -- -- -- -- -- -- 667 1000 1500 40 69 103 -- -- -- -- -- -- 750 1500 2250 46 69 103 -- -- -- -- -- -- 800 1500 2250 60 138 206 -- -- -- -- -- -- 850 2000 3000 70 138 206 -- -- -- -- -- -- 1000 2000 3000 Table 4. Pressure Reference Types Pressure Reference 1 2 4 Description Absolute Output is proportional to the difference between applied pressure and a built-in fixed reference to vacuum (zero pressure), where the minimum operating pressure is set to absolute zero pressure (perfect vacuum). Sealed gage1 Output is proportional to the difference between applied pressure and a built-in fixed reference to 1 atmA, where the minimum operating pressure is set to 14.7 psiA (1 atmA). Vented gage2 Sensor measures pressure relative to ambient pressure. Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure, where the minimum operating pressure is set to atmospheric pressure. Sealed gage option only available in pressure ranges at or above 100 psi. Vented gage option only available in pressure ranges between 100 psi and 667 psi. Sensing and Internet of Things Heavy Duty Pressure Transducers PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi Table 5. Environmental and Mechanical Characteristics Characteristic Mechanical shock Vibration Enclosure rating Wetted materials: port substrate adhesives electronics Parameter 100 G per MIL-STD-202F, Method 213B, Cond. F (at 25C) 20 G sweep, 10 Hz to 2000 Hz (at 25C) per electrical connector type selection (See Figure 5.) 304 stainless steel alumina ceramic epoxy glass, silicon External materials: housing connector: UL 94 HB (standard) UL 94 V-0 (optional) cable jacket Installation torque 304 stainless steel PBT 30% GF, black PBT 30% GF, natural (beige) TPE per pressure port type (See Figure 6.) CAUTION PRODUCT DAMAGE DUE TO MECHANICAL ISSUES * Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating materials and thread sealants can result in significantly different torque values from one application to the next.) * When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling. Ensure the sealant is rated for the application. * Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers. * Always hand-start transducers into the hole to prevent cross threading and damage. * Ensure that torque is not applied to the electrical connector. * Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals can compromise ingress protection, leading to short circuits. Failure to comply with these instructions may result in product damage. CAUTION PRODUCT DAMAGE DUE TO PARTICULATES * Ensure that a filter is used upstream of the transducer to keep media flow free of larger particulates and increased humidity. All PX2 Series transducers are dead-ended devices; particulate accumulation and condensing moisture may affect sensor output. * It is recommend that the transducer be positioned with the port facing downwards; any particulates in the system are less likely to enter and settle within the pressure transducer if it is in this position. * Ensure that the media does not create a residue when dried. Build-up inside the transducer may affect transducer output; rinsing of a dead-ended transducer is potentially difficult and has limited effectiveness in removing residue. Failure to comply with these instructions may result in product damage. Sensing and Internet of Things 5 6 PX2 Sensing and Internet of Things Pressure Port Type Sensor Body Electrical Connector Type Heavy Duty Pressure Transducer1 Series PX2 Cable harness, 2 meter cable length3 Cable harness, 3 meter cable length3,4 E F G J Metri-Pack 150 (UL 94 V-0)2 Cable harness, 5 meter cable length3,4 (threewire) Cable harness, 1 meter cable length3 H Deutsch (DTM04-3P) DIN (EN 175301-803C) Micro M12 (IEC 61076-2) (For UL 94 V-0 version, see order code J below.) D C B A (twowire) 1 1/4-18 NPT M1 N1 7/16-20 UNF (SAE J1926-3) 9/16-18 UNF (SAE J1926-3) 46 bar 60 bar 046B 060B 70 bar 40 bar 040B 070B 25 bar 16 bar 10 bar 025B 016B 010B 008B 6 bar 006B 8 bar 4 bar 2.5 bar 2.5B 004B 2 bar 1.6 bar 1 bar 002B 1.6B 001B bar 007G 006G 4.6G 004G 2.5G 1.6G 001G 600K 400K 25OK 160K 100K 015P 7 MPa 6 MPa 4.6 MPa 4 MPa 2.5 MPa 1.6 MPa 1 MPa 600 kPa 400 kPa 250 kPa 160 kPa 100 kPa 01KP 750P 667P 600P 500P 300P 250P 200P 150P 100P 050P 030P 1000 psi 750 psi 667 psi 600 psi 500 psi 300 psi 250 psi 200 psi 150 psi 100 psi 50 psi 30 psi 15 psi G S A 5 AA CH BG BE BD BC AD AC AB Current: 4 mA to 20 mA Regulated: 1 Vdc to 5 Vdc Regulated: 0.5 Vdc to 4.5 Vdc Regulated: 0.25 Vdc to 10.25 Vdc Regulated: 1 Vdc to 6 Vdc Ratiometric 3.3 V: 5 %Vs to 95 %Vs Ratiometric 3.3 V: 10 %Vs to 90 %Vs Ratiometric 5.0 V: 5 %Vs to 95 %Vs Ratiometric 5.0 V: 10 %Vs to 90 %Vs Metri-Pack 150 mating connector2 Vented gage6 Sealed gage Absolute Output Transfer Function psi Pressure Range Pa BD A Pressure Reference 150P 2 Not all catalog listing combinations are available. Custom products are available. Please contact Honeywell. Metri-Pack 150 mating connectors with shielded cable and three 22 AWG wire are available from Honeywell. Order part no. 3685301 for 1 m [3.2 ft] cable length and part no. 3685302 for 3 m [9.8 ft] cable length. 3 Three-wire cable is required for ratiometric and regulated outputs; two-wire cable is required for current output. 4 Three meter and five meter cables are only available with Output Transfer Function CH = Current, 4 mA to 20 mA. 5 Sealed gage option only available in pressure ranges at or above 100 psi. 6 Vented gage option only available in pressure ranges between 100 psi and 667 psi (not available on cable harness configurations). 7 Reserved for future use. S2 S1 1/8-27 NPT M12 x 1.5 (ISO 6149-3) G2 N2 G1/8 (ISO 1179-3) G1/4 (ISO 1179-3) G1 F2 7/16-20 UNF 37 Flare Male (SAE J514) 7/16-20 UNF 45 Flare Male (SAE J513) F3 7/16-20 UNF 1/4 in 45 Flare Female Schrader (SAE J512) F1 Pressure Port Type Electrical Connector Type Metri-Pack 150, Standard (UL 94 HB)2 N1 A XX7 X7 For example, PX2AN1XX150PABDX defines a PX2 Series Heavy Duty Pressure Transducer, Metripak 150, standard, electrical connector type, 1/4-18 NPT pressure port type, 150 psi pressure range, absolute pressure reference, regulated: 0.25 Vdc to 10.25 Vdc output transfer function. Heavy Duty Pressure Transducers PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi Figure 4. Nomenclature and Order Guide Heavy Duty Pressure Transducers PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi Figure 5. Electrical Connector Type Dimensions (For reference only: mm/[in].) "H" A Metri-Pack 150, Standard (UL 94 HB) B C Micro M12 (IEC 61076-2) J DIN (EN 175301-803C) Metri-Pack 150 (UL 94 V-0) Connector: IEC 61076-2-101 Connector: DELPHI 12078088 Mating Connector: DELPHI 12110192 Mating Connector: 4 POS TYPE D IP Rating1: IP65/IP67 (absolute, sealed IP Rating1: IP65 (all versions) gage versions) , IP65 (vented gage versions) Connector: EN 175301-803C Mating Connector: EN 175301-803C DIN 43650C 8MM IP Rating1: IP65 (all versions) Pin Voltage Output Current Output Pin Voltage Output Current Output Pin Voltage Output Current Output A GND RTN 1 V+ supply 1 GND RTN B V+ supply 3 GND RTN 2 V+ supply C Vout NC 4 Vout NC 3 Vout NC PE NC NC B 1 C 4 A "H" = 46,0 [1.81] 1 1 PE 3 17,0 [0.67] o17,0 [0.67] 3 2 Hole (vented gage versions only) o11,5 [0.45] "H" = 40,7 [1.60] Hole (vented gage versions only) Hole (vented gage versions only) "H" = 36,2 [1.46] IP rating is determined by the electrical connection chosen. Sensing and Internet of Things 7 Heavy Duty Pressure Transducers PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi Figure 5. Electrical Connector Type Dimensions (continued) "H" E Cable Harness, 1 Meter2 F Cable Harness, 2 Meter2 G Cable Harness, 3 Meter2, 3 H Cable Harness, 5 Meter2, 3 D Deutsch (DTM04-3P) Connector: Deutsch DTM04-3P Mating Connector: DTM06-3S IP Rating1: IP65, IP67, IP69K (absolute, sealed gage versions), IP65 (vented gage versions) Connector: 24 AWG with TPE Jacket Mating Connector: Flying leads IP Rating1: IP65, IP67, IP69K (absolute, sealed gage versions) Pin Voltage Output Current Output Wire Color Voltage Output Wire Color Current Output 1 GND RTN red V+ red supply 2 Vout NC black GND 3 V+ supply white Vout black RTN 2 1 3 A B A C 20,61 [0.81] o16,1 [0.63] o16,1 [0.63] Hole (vented gage versions only) "H" = 51,2 [2.01] "H" = 55,0 [2.16] "H" = 55,0 [2.16] IP rating is determined by the electrical connector type chosen. Three-wire cable is required for ratiometric and regulated outputs; two wire cable is required for current output. 3 Three meter and five meter cables are only available with Output Transfer Function CH = Current, 4 mA to 20 mA. 1 2 8 Sensing and Internet of Things B Heavy Duty Pressure Transducers PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi Figure 6. Pressure Port Type Dimensions (For reference only: mm/[in].)1 22 Hex flat to flat [0.87] "P" F1 7/16-20 UNF 1/4 in 45 Flare Female Schrader (SAE J512) F2 7/16-20 UNF 45 Flare Male (SAE J513) Seal: 45 cone Mating geometry: SAE J513 Installation torque2: 1/4 Turn from finger tight Seal: 45 cone Mating geometry: SAE J512 Installation torque2: 17 N m [12.5 ft-lb] "P" = 17,4 [0.68] "P" = 19,2 [0.75] 12,3 [0.49] F3 G1 7/16-20 UNF 37 Flare Male (SAE J514) G1/4 ( ISO 1179-3) Seal 3,4: O-ring Mating geometry: ISO 1179-1 Installation torque2: 50 N m [38.9 ft-lb] Seal 3,4: 37 cone Mating Geometry: SAE J514 Installation Torque2: 16 N m [11.8 ft-lb] "P" = 20,5 [0.81] "P" = 16,2 [0.64] 11,2 [0.44] 15,5 [0.61] G2 M1 G1/8 (ISO 1179-3) M12 X 1.5 (ISO 6149-3) Seal 2,3: O-ring Mating geometry: ISO 6149-1 Installation torque2: 25 N m [18.4 ft-lb] Seal 3,4: O-ring Mating geometry: ISO 1179-1 Installation torque2: 25 N m [18.4 ft-lb] "P" = 18,5 [0.73] "P" = 12,6 [0.50] 7,6 [0.30] N1 S1 13,5 [0.53] N2 1/4-18 NPT Seal: pipe thread Mating geometry: ANSI B1.20.1 Installation torque2: 2 to 3 turns from finger tight "P" = 20,0 [0.79] 15,0 [0.59] 1/8-27 NPT Seal: pipe thread Mating geometry: ANSI B1.20.1 Installation torque2: 2 to 3 turns from finger tight S2 9/16-18 UNF (SAE J1926-3) 7/16-20 UNF (SAE J1926-3) 3,4 "P" = 18,5 [0.73] 13,5 [0.53] 2 3 4 "P" = 15,0 [0.59] 10,0 [0.39] Seal : O-ring Mating geometry: SAE J1926-1 Installation torque2: 18 N m [12.3 ft-lb] Seal : O-ring Mating geometry: SAE J1926-1 Installation torque2: 30 N m [22.1 ft-lb] 3,4 1 12,3 [0.49] "P" = 17,5 [0.69] 12,5 [0.49] See CAUTION "PRODUCT DAMAGE DUE TO MECHANICAL ISSUES" on page 5. Straight thread maximum torque is validated to 150% of installation torque. Seals for pressure port type order codes S1, S2, M1, G1 and G2 are included and assembled to the sensors. O-ring material is nitrile 70 durometer -30C to 125C [-22F to 257F]. Sensing and Internet of Things 9 ADDITIONAL INFORMATION The following associated literature is available on the Honeywell web site at sensing.honeywell.com: WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. * Product line guide * Product range guide * Product installation instructions * Application notes: - Heavy Duty Pressure Transducers, PX2 Series and PX3 Series - PX2 Series and PX3 Series Heavy Duty Pressure Transducers for Potential Use in Industrial Refrigeration - PX2 Series and PX3 Series Heavy Duty Pressure Transducers for Potential Use in Industrial HVAC/R Applications * Technical notes: - Total Error Band Specification for Honeywell Heavy Duty Pressure Transducers, PX2 Series and PX3 Series - Media Compatibility for Honeywell Heavy Duty Pressure Transducers, PX2 Series and PX3 Series * CAD models Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION * The information presented in this datasheet is for reference only. Do not use this document as a product installation guide. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer's sole responsibility to determine the suitability of the product in the application. Find out more Honeywell serves its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. To learn more about Honeywell's sensing and switching products, call +1.815.235.6847 or 1.800.537.6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywell.com 500599462-I-EN | I | 06/17 (c) 2017 Honeywell International Inc. Solstice(R) N40 is a registered trademark of Honeywell International Inc.