TS-200 200W True Sine Wave DC-AC Power Inverter series Features : True sine wave output (THD<3%) High surge power up to 400W High efficiency up to 88% Fanless design, cooling by free air convention Built-in remote ON-OFF control Front panel indicator for operation status Power ON-OFF switch Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input reverse polarity / Overload Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. 3 years warranty E13 SPECIFICATION MODEL TS-200-112 INPUT TS-200-148 TS-200-212 200W MAXIMUM OUTPUT POWER 230W for 180 sec. / 300W for 10 sec. / surge power 400W for 30 cycles(typ.) AC VOLTAGE OUTPUT TS-200-124 RATED POWER FREQUENCY TS-200-224 TS-200-248 Factory setting set at 110VAC Factory setting set at 230VAC 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W 600.1Hz 500.1Hz 50/60Hz selectable by setting button WAVEFORM Note.1 True sine wave (THD<3%) AC REGULATION Note.1 3.0% at rated input voltage 50/60Hz selectable by setting button FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal BAT. VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC DC CURRENT (Typ.) 20A 21 ~ 30VDC 10A 42 ~ 60VDC 5A 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 20A 10A 5A NO LOAD CURRENT DRAW (Typ.) 1.25A 0.63A 0.32A 1.25A 0.63A 0.62A 88% 86% 87.5% 88% OFF MODE CURRENT DRAW 1mA EFFICIENCY (Typ.) Note.1 86% BATTERY TYPES FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN BAT. POLARITY OVER TEMPERATURE OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) GFCI PROCTECTION 15A*1 454% 30A*2 11.34% 30A*1 22.54% 15A*1 454% 10.54% 214% 424% 10.54% 214% 424% 80 5 80 5 85 5 80 5 80 5 By internal fuse open 85 5 Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY -10 ~ +35 @ 100% load ; +60 @ 50% load 20% ~ 90% RH non-condensing -10 ~ +40 @ 100% load, +60 @ 50% load STORAGE TEMP., HUMIDITY VIBRATION -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH LVD SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF NOTE 30A*1 22.54% None SAFETY STANDARDS OTHERS 30A*2 11.34% Optional (Only type F) Open : Normal work ; Short : Remote off FUNCTION REMOTE CONTROL ENVIRONMENT 87.5% Open & sealed Lead Acid DIMENSION PACKING 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes None Design refer to UL458 None Bat. I/P - AC O/P:3.0KVAC EN60950-1 AC O/P - FG:1.5KVAC Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to FCC class A None Compliance to EN61000-4-2,3,8 106.2K hrs min. MIL-HDBK-217F (25) 205*158*59mm (L*W*H) 1.63Kg; 6pcs/10.8Kg/1.44CUFT 1.Efficiency, AC regulation and THD are tested by 200W, linear load at 13V/26V/52V input voltage. 2.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting. 3.The tolerance of each voltage value by models is:112/2120.5V;124/2241V;148/2482V File Name:TS-200-SPEC 2015-05-27 TS-200 200W True Sine Wave DC-AC Power Inverter TS 200 112 A A :TYPE B :TYPE C :TYPE D :TYPE E :TYPE F :TYPE 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC True sine wave inverter Output: O/P Wattage:200W 1:110VAC 2:230VAC A B C D E F series OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET AC Output Receptacles (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Country E13 Certificate E13 E13 Derating Curve Mechanical Specification Unit:mm R.C Connector : JST B-XH or equivalent Normal work Remote off 100 24.82 10.7 Open Short TS-200-2xx 80 Chassis Ground R.C _ LOAD (%) 59 60 TS-200-1xx 50 40 20 _ _ OFF Reverse Polarity Will Damage The Unit. ON 11 8.9 0 10 20 30 35 40 50 60 12 18 -10 70 (HORIZONTAL) 42.5 ENVIRONMENT TEMPERATURE () 7 9 AC OUTPUT Status 205 120 Setting Type-A Status AC OUTPUT Setting Type-B 147 158 File Name:TS-200-SPEC 2015-05-27 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Mean Well: TS-200-112A TS-200-148A